OFFICE OF THE EXECUTIVE ENGINEER ED Awantipora
OFFICE OF THE EXECUTIVE ENGINEER ED Awantipora
Creation of 2X250 KVA Sub-Station along with 11KV Line at IRP Bn. Hqrs. Pulwama
2023_PDD_223012_1
EDA-29 OF 2023-24
Open Tender
Electrical Works
Turn-key
35 days
Awantipora
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
OFFICE OF THE EXECUTIVE ENGINEER ED Awantipora
₹96,000
OFFICE OF THE EXECUTIVE ENGINEER ED Awantipora
7 Aug 2023
22 Jul 2023
4 Aug 2023
22 Jul 2023
3 Aug 2023
22 Jul 2023
22 Jul 2023 - 3 Aug 2023
27 Jul 2023
Amount
Supply,Installation,testing and commissioning including Loading, Transportation , insurance, Unloading, Carriage and Delivery at Site of 250KVA- 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Copper wound ), and with LV Cable Box having detachable Aluminium Gland plate.Transformer should have arrangement for vertical Take off
Supply, Errection,testing & commissioning including loading, transportation, insurance, unloading, carriage and delivery at site of 9 Mtr long ST Poles SP-33 including excavation of pole pits, refilling the pit with soil, boulders.
Supply, Errection,testing & commissioning including loading, transportation, insurance, unloading, carriage and delivery at site of 8 Mtr long ST Poles SP-15 including excavation of pole pits, refilling the pit with soil, boulders.
Supply, Laying,testing, stringing, tensioning and binding of 50 mm² AB (HT) Cable (3x50 + 1x70 mm²) XLPE(11 kV, 3C + Earth)
Supply, Laying,testing, stringing, tensioning and binding of conductor ACSR 0.1 (Dog) including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site.
Supply, Laying,testing, stringing, tensioning and binding of conductor ACSR 0.05 (Rabibit) including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site.
Supply, Laying,testing,Heat Shrinkable Outdoor Cable Termination Kit.
Supply, Laying,testing,Suspension/Tension Clamp with eye hook.
Providing & fixing of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm.
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) inscribed with permenent marking on each pole viz. name of scheme - 2022-23/xx - xxmeans pole numbers say 01,02....
Providing & and fixing of GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O/DISTRIBUTION BOX/D.O Set including clamps and nuts and bolts. set/Horn Gap.
Providing & and fixing of GI Channe for Transformer Pad/G.I Channel Bedding(300Kg/450kg)
Providing, fixing of channel cross arms, V-Cross arms etc fabricated out of Mild Steel of different sizes (REC Standard) & to be fixed with GI Nuts & Bolts and washers without drilling/punching holes in the poles.
Providing & and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN)
Providing & fixing of 11 kV, G.O AB Switch , 3-phase, 200A (09 insulator post type) with arragement for pad locks & operating rod . The operating rod should be G.I Pipe (B-class) of 25 mm dia of requisite length.
Providing & fixing of 11 kV Horn, Gap Fuse 3-phase 100A
Providing & fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type.
providing and fixing of LT Distribution Box for 250 kVA DTR with MCCB (400A ) for incomer & SFU's for Outgoing Circuits.
Providing & fixing of 11KV link set heavy duty, 400A,line type with 50X6 mm Copper Blade.
Providing & fixing of 300 mm²(2Ckt) Single Phase Cable,1.1K V Grade, XLPE insulated Stranded Conductor FRLS type
Providing, laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole including muffing 20 cm above ground level, plaster and curing of concrete.
Providing, laying of Cement bottoming 1:2:4 mix as per REC standards 0.45cum/pole including muffing 20 cm above ground level, plaster and curing of concrete.
Providing & fixing of bi-metallic clamps for fixing of LT cable with distribution transformers having capacity upto 100 kVA
Providing & fixing of 300 mm sq Aluminum Thimbles for cable terminations
Providing & fixing of 3-Phase 4-Wire Trivector Meter with Suitable CT for 250KVA DT.
Providing and and fixing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing and fixing of shackle insulators (polymer) ( 16 KN) with GI back clamps to be fixed without drilling/punching of poles on ST poles.
M/S HILL STAR ELECTRICALS
M/S HILAL ENTERPRISES
I.O CONSULTANCY & WORKS
FAYAZ AHMAD DAR
UBAID SUPPLIERS AND CONTRACTORS
NUCLEON ELECTRICALS MECHNICAL AND SUPPLIERS
M/S AKASH ELECTRICALS AND MECH
M/s NEW DAR ELECTRICALS
southern
MS BISMILLAH ENTERPRISES
MS WASEEM ENTERPRISES
M/s HAJAHAD CONSTRUCTION COMPANY
AZEEM CONSTRUCTIONS
M/S SOFI SONS
Rayyan Electrical Engineering Works
I.CON ELECTRICALS
M/S FRIENDS ELECTRICAL /MECH/ELECTRONICS
M/s NORTHERN ELECTRICALS
M/S STAR ENGINEERS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .