Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-Finance ASANSOL DIST PASCHIM BARDHAMAN | ASANSOL | PASCHIM BARDHAMAN | WEST BENGAL | L1 | Accepted-Finance STOOD L1 | |
| 2 | L2₹14.0 L+₹10,253.05 (0.74%)Rejected-Finance 70 GAUTAM BUDDHA MARG C ZONE DURGAPUR PASCHIM BARDHAMAN WEST BENGAL | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | 713205 | L2 | Rejected-Finance STOOD L2 | |
| 3 | L3₹15.5 L+₹1.6 L (11.7%)Rejected-Finance KANKARDANGA | L3 | Rejected-Finance STOOD L3 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
4 Oct 2024, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE.AED.PWD
Office of the Executive Engineer (P.W.D.) Asansol Electrical Division Near Polo Ground Dist Paschim Bardhaman PIN 713304
Renovation of Electrical work in Nursing Hostel of Asansol District Hospital, Paschim Bardhaman under RATTIRER SATHI Project.
2024_WBPWD_759692_1
WBPWD/EE/AED /eNIQ-67/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
ASANSOL
Please refer Tender documents.
4 documents required · 4 mandatory
₹40,000
Office of the Executive Engineer P.W.D. Alsanso
14 Sept 2026
28 Sept 2024
4 Oct 2024
28 Sept 2024
4 Oct 2024
29 Sept 2024
30 Sept 2024
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 8 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish.(On Board)
Average run 3 mtr
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required: 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC.
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC.
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC .
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles(25 mm dia 3 mm thick polythene pipe without earth continuity wire)
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles(19 mm dia 3 mm thick polythene pipe without earth continuity wire) .
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 10sq mm
Supplying and fixing 415V,16-32A per way , double door Horizontal TPN MCB Distribution board (Enclosure (607716)with IP-42/43 protection,with 63A, 4 pole isolator as incomer and SPMCB's ('C' curve,10kA) as outgoing concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand/ABB/Siemens) a) 4 way,,63A FP isolator,12nos. SPMCBs as outgoing
Supplying and fixing double-door SPN MCB Distribution Board(Enclosure-607711) with IP-42/43 protection, with DP isolators as incomer and SPMCB('C' Curve,10A) as outgoing,fixing at flat iron frame on wall &mending good the damages to original finish; inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make: Legrand/ABB) i) (2+8)Way,with S&F 240V 40Amps DPMCB isolator as incomer and 240V 6-32A SPMCB of Breaking capacity 10KA & C characteristics 8 nos as outgoing, 2+8 Way (Legrand/ABB/Siemens)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. supply of 16 A DP MCB ,painting,connection & provision for earthing attachment .
Supply & delivery of XLPE/A Al cable of following size with 2 nos 10 SWG GI wire as ECC.(Make- Havells/Polycab/KEI/Gloster) as per choice of EIC. 4Core 35 Sqmm. (From panel to TPNDB)
2Core 10 Sqmm. (For charging Street Light)
Supplying and fixing 415V, 100ATPN SFU with sheet steel enclosure on flat iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :4 core 35 sqmm
2Core 10 Sqmm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4 core 35 sqmm .
2Core 10 Sqmm.
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
S/Delivery following 250 Volt, 18/20 Watt, 4 Ft. long single/double LED Tube fittings complete with LED polycarbonate tube lamp having at least 100 lumen/watt and cast iron box type fittings.(Make- Havells/Crompton/Philips Master LED)a. Single LED Tube(18/20 Watt) (With Two Years Warrenty)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp whose both side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener.
S/F BC LED lamp (B22) as per direction of E.I.C. (Make- Philips/Crompton/Syska)(12watt)
Supplying and delivery of 250 volts, 50Hz, (12”) sweep 1420 R.P.M. heavy duty exhaust fan complete with all accessories (Make-EPC) as per direction of EIC. Exhaust fan(12”)
Supplying and delivery of 250 volts, 50Hz, (9”) sweep 1420 R.P.M. heavy duty exhaust fan complete with all accessories (Make-EPC) as per direction of EIC. Exhaust fan(9”)
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm (9')
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) : i)For 23 cm (9") Exhaust fan
ii)For 30 cm (12") Exhaust fan
Supply of 48"ceiling fans complete with all accessories like fan blade,canopy,capacitor etc Model / Cat No. ( Make - USHA /Crompton Greaves/Havells ) as per direction of EIC a.1200 mmSweep . (With Two Years Warrenty)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWDSpecification Book – May 1991)
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below) as per GS Upto 9.0 mtr. Size 0.6x0.6x1.70 mts.
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below) as per GS Upto 9.0 mtr. Size 0.6x0.6x1.70 mts.
Supply &Errection of 2Mtr GI Pole (ISI-M)(Dia80mm) to be fixed by muffing above the roof as per direction of EIC
S&F 50 mm. dia 2 mtr. long detachable type Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC
Painting of each Steel Tubular Pole of lengths ( Upto 9 Mtr ) with 2 coats of Aluminium Paint over 1 coat of RO primer as per GS .
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
S&F of 120W LED street light on the pole arm Make :Havells/Crompton/ Philips. Cat no TRP-411-120-57-HL2-GL-NSG. (With Five Years Warrenty)
Earthing the installation by 2" ( 50 mm) dia ISI (M) GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as per G.S. in morrum soil.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as per G S.
Connecting the equipments to earth busbar including S & F No.4 SWG GI (Hot Dip) wire of size on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as per GS
Excavation of soil for installation of Earth Electrode and filling & ramming. For morrum soil.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required i)40 mm
Dismantling the existing distribution boxes,wiring, Concealed switch board, Concealed type JB,Panel related all acessories light fixtures and fittings etc. and mending good the damages to the original finish by neat cement plaster cover with 1.5mm thick wall putty as existing wall matching as required.Dismantled items to be handed over to competent authority including transportation,loading and unloading both side as per direction of EIC.
Add GST @18% On total from item no 1 to 41.
Add LWC @1% On total from item no 1 to 42.
KOUSHIK MONDAL (BID ID -5660834)
SASTIK ENTERPRISE (BID ID -5674074)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
cancelled_1.pdf
pdf • 0.04 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .