Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC H O PRABHAT KUMAR SINHA RAGHUNATH TOLA ANISABAD PATNA 800002 | PATNA | PATNA | BIHAR | 800002 | ₹8.1 L | L1 | Accepted-AOC QUOTED RATES ARE REASONABLE AND ACCEPTED |
| 2 | L2₹8.9 L+₹79,987 (9.82%)Rejected-Finance | ₹8.9 L+₹79,987 (9.82%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹10.1 L+₹2.0 L (24.1%)Rejected-Finance B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹10.1 L+₹2.0 L (24.1%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹10.4 L+₹2.2 L (27.4%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹10.4 L+₹2.2 L (27.4%) | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
13 Feb 2024, 6:00 pmClosed
GE AF BIHTA
AIR FORCE STATION BIHTA - 801103
REPAIR/MAINT OF WATER SUPPLY PUMP MOTORS AUTOMATIC DOSING SYSTEMS, CI/GI/DI PIPELINE CLEANING OF OH TANKS AND ALLIED WORKS AT AF STN DARBHANGA UNDER GE (AF) BIHTA
2023_MES_632406_2
8370/BHT/DBG/E8
Open Tender
Pipes and Pipe related activities
Item Rate
150 days
Darbhanga
CLASS E CATEGORY a(ii)
6 documents required · 6 mandatory
₹500
GE (AF) Bihta
₹20,000
Yes
28 Mar 2024
25 Jan 2024
21 Feb 2024
25 Jan 2024
13 Feb 2024
1 Feb 2024
27 Jan 2024 - 29 Jan 2024
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for under ground cable / erection of poles, stays, laying of pipelines etc, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in soil including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick, complete all as specified and as directed by Engr-in-Charge.
Removing of excavated material not exc 50 mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and as directed by Engr-in-Charge.
M & L for cleaning of over head reservoir internally from base to top including scraping the mud silt from base and walls, washing the complete internal surfaces with bleaching powder, antibacterial sodium hypochlorite solution to inner surface with clean water, removing the silt/mud water out side the tank and desilting from connecting pipes and applying internally one coat of lime wash to RCC walls, base of tanks of 5000 gallons upto 30 mtrs staging complete & writing details of cleaning in prescribed format complete all as specified and as directed by Engr-in-Charge. Location : Pump House No 1 &3
S & F in replacement of old unsv panel inbuilt star delta starter/DOL assembly complete suitable upto 25 HP sub mersible pumping set fixed in LT control panel of pump house including replacement of existing unsv panel wirings and accessories complete all as specified and as directed.
S & F in replacement of old unsv agitator motor, 120W, single phase, 220 V AC, 50 Hz, 6 pole, 960 RPM where directed and testing upto the satisfaction of Engr-in-Charge, complete all as specified and as directed.
Water testing per month as per approval lab civil medical authority’s of test chemical and biological report and including all testing kit and other items, water collected in presence of medical staff in the stn and report submitted to every month first week or as required all as specified and as directed. Note:- Test certficate shall be provided from authorised laboratory
M & L for rewinding of burnt submersible pumping set of capacity 25 HP capacity with the existing gauge of copper winding wire with same insulation including replacement of bearings complete all as per standard norms and testing upto the satisfaction of Engr in-charge including taking out and refixing the motor/pump at any depth.
Taking out up/down old unserviceable DI/CI pipe with all fittings from trenches of following sizes all as directed :- Note:- Excavation & earth work will be measured & paid seperately under respective item ). (a)100mm
Supply, laying, jointing and testing DI pipe of 100 mm bore ISI marked, spigot and socketed type, Class K-7 centrifugally cast suitable for rubber tyton joints laid in trenches complete all as specified and as directed by Engineer-in-charge.
Supply, laying, jointing and testing Cast iron pipes 100 mm bore, with spigot and socket ends, vertically cast, class B, in any length and laid in trenches, complete all as specified and as directed.
M & L Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150mm bore for spigot socketed pipes, complete all as specified and directed.
M & L Bends, Tapers, Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged upto 150mm bore for flanged pipes, complete all as specified and directed.
Taking out old unserviceable GI tubing with all fittings from trenches, walls, floors etc of following sizes complete all as specified and as directed by Engr-in-Charge:- Note:- Excavation & earth work will be measured & paid seperately under respective item ). a) 50 mm bore
b) 25 mm bore
M & L for GI pipe medium grade with all fittings, laid in trenches, 50 mm bore, ISI Marked, complete all as specified and as directed by Engineer-in-Charge.
M & L for GI pipe medium grade with all fittings, fixed to walls, floor or ceiling, 50 mm bore, ISI Marked, complete all as specified and as directed by Engineer-in-Charge.
M & L for GI pipe medium grade with all fittings, laid in trenches, 25 mm bore, ISI Marked, complete all as specified and as directed by Engineer-in-Charge.
M & L for GI pipe medium grade with all fittings, fixed to walls, floor or ceiling, 25 mm bore, ISI Marked, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of load line MCCB 100 Amps 4 pole 415 volts with adjustable thermal and fixed magnetic setting of breaking capacity 25 KA, Ics=100% Icu, including taking down the old existing MCCB, complete all as directed by Engr-in-Charge.
S&F in replacement of load line MCCB 63 Amps 4 pole 415 volts with adjustable thermal and fixed magnetic setting of breaking capacity 25 KA, Ics=100% Icu, including taking down the old existing MCCB, complete all as directed by Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead strip of 25x4 mm as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 40 mm bore for protection of GI earth strip from earth electrode to test point /machinery / equipment. supplying and laying charcoal dust comman salt PCC (1:2:4) type B1 using 20 mm graded stone agregrate chamber and RCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1 using 20 mm stone agrigrtae ) reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in electrical plate No-3 of SSR part-1 including testing, complete all as specified and directed Note - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items.
Material & Labour for brick masonry valve pit internal size 900mm x 900mm x 900mm with one brick thick wall using sub class ‘B’ brick in cement mortar 1:6 over 20cm thick PCC platform with 15cm off sets on every side of 1:3:6 type C-1 including plastering of internal surfaces and exposed surfaces with 15mm thick plastering in cement mortar 1:4 and 50mm thick RCC cover (in two equal parts 1:2:4 type B-1 with 10mm dia deformed bars at 10cm interval on both side including necessary form work with 150mm dia hole in the center complete all as specified and as directed by Engineer-in-Charge
Description all as per ser item No 20 here-in-before but of size 600mm x 600mm x 600mm -ditto-, complete all as specified and directed.
Supply and fixing of butterfly valve, lever operated, pressure rating PN-1.6, water type nitrile rubber lining, suitable insertion between flange ends, 80mm nominal bore ISI marked complete with MS tail pieces double side flanged incuding welding work as per site requirement, rubber/fiber board gasket, nut & bolt, washers etc, including taking down old one, complete all as specified and directed by Engr-in-Charge.
S & F in replacement of unsv/damaged gun metal globe or gate valve of following sizes with cast iron wheel head screwed both ends for iron pipe complete all as specified and as diected :- (a) 50mm bore
(b) 40mm bore
(c) 20mm bore
(d) 25mm bore
Material and Labour for repairing pipe line, any type of joint, any size of valve, fitting re-assembling the fitting including earth work /any other work on day to day complaint basis, complete all as specified and directed by Engineer-in-Charge. Note:- Quoted rate shall be deemed of all spare parts required for repair of any type of pipe line.
Supply, install, testing and commission of out door type cubical feeder pillar box outer shell made out of 3.15 mm thick MS sheet inner shell made out of 2.00 mm thick MS sheet and MS angle section 40x40x6 mm on PCC 1:2:4 type B-1 platform 45cm above the ground level and 30 cm below the ground level, frame factory fabricated with front and back openable double door system complete suitable for 3 phase 4 wire 415 Volt, 50 Hz, comprising of the following:- a) TPN, aluminium bus bar 600 Amps insulated with colour coded heat shrinkable sleeve provided with Changer switch of amp same as incoming MCCB. b) Incoming MCCB 4 pole 400 Amps, 36 KA, Ics = 100% of Icu -01 Nos c) Outgoing MCCB 4 pole 160 Amps, 25 KA, Ics = 100% of Icu -04 Nos c) Outgoing MCCB 4 pole 100 Amps, 25 KA, Ics = 100% of Icu -02 Nos c) Indicator lamps RYB –01 Set d) Digital Voltmeter 0-500 volts 96 mm square flush pattern - 01 No e) Digital Amp meter 0-400 Amps 96mm square flush pattern - 01 No
Note:- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, spreaders, provision of extra holes in bus bar, provision of cable gland etc. (ii) All internal wiring shall be done with suitable size (iii) The panel shall be mounted on brick wall not less than the height of 0.6m of three sides and masnory work complete all as directed incl white washing for brick work.
M&L for strip opening of unsv pumping sets, copper winding wires of any gauge, rewinding of motor by using new PVC insulated copper wire of same gauge of submersible electric motor 3 phase 415 volts 5/7/7.5 HP capacity including taking out and refixing the motor/pump at any depth, complete all as specified and directed.
S&F 3 core flat copper conductor, multistranded cable for submersible pump set of 1100 volt grade 10 sqmm size, including disconnecting and taking down old one, complete all as specified and directed.
Supply & Fixing in replacement of old unsv CI Sluice valve with flanged ends of size 100 mm dia, PN 1.6 complete with gun metal or stainless steel spindle and cast iron hand wheel including rubber / fiber board gasket,nuts, washer etc including taking down old/ unservicable Sluice valve, complete all as specified and as directed by Engineer-in Charge.
Supply & Fixing in replacement of old unsv CI Sluice valve with flanged ends of size 150 mm dia, PN 1:6 complete with gun metal or stainless steel spindle and cast iron hand wheel including rubber / fiber board gasket, nuts, washer etc including taking down old/unservicable Sluice valve, complete all as specified and as directed by Engineer-in Charge.
M & L for GI pipe medium grade with all fittings, laid in trenches, 80 mm bore, ISI Marked, complete all as specified and as directed by Engineer-in-Charge.
M & L for GI pipe medium grade with all fittings, fixed to walls, floor or ceiling, 80 mm bore, ISI Marked, complete all as specified and as directed by Engineer-in-Charge.
G S CONSTRUCTION
PAPPU ROY CONSTRUCTION
B.K. ROY & SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .