Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAccepted-AOC AT MAIN ROAD KATHARA PO KATHARA BOKARO JHARKHAND 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | ₹3.6 L | L1 | Accepted-AOC ACCEPTED AS PER NIT |
| 2 | Rejected-Technical AT JHIRKEY PO KATHARA DIST BOKARO JHARKHAND | KATHARA | BOKARO | JHARKHAND | 829116 | - | - | Rejected-Technical Technically Rejected, as per NIT |
| 3 | Rejected-Technical AT WASHERY ROAD KATHARA BOKARO JHARKHAND 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | - | - | Rejected-Technical Technically Rejected, as per NIT |
| Sl No | Description | Qty | Unit | M/S ATRACON ELECTRICALS L1 |
|---|---|---|---|---|
| 1.01 | Cost of 11KV Primary busing insulator with stud | 3 | No | 9,300 ₹27,900 |
| 1.02 | Cost of 550V secondary busing insulator with stud | 3 | No | 6,900 ₹20,700 |
| 1.03 | Cost of copper Patti for connection (8mm x 2" x 10") of required hole size | 5 | No | 2,000 ₹10,000 |
| 1.04 | Cost of copper Lugs of size 185sqmm | 8 | No | 600 ₹4,800 |
| 1.05 | Cost of Aluminum PG clamp of required size(heavy duty), three bolt | 3 | No | 1,450 ₹4,350 |
| 1.06 | Cost of Bimetallic clamp | 5 | No | 2,930 ₹14,650 |
| 1.07 | Cost of Cork Sheet of size 8mm | 1 | No | 11,000 ₹11,000 |
| 1.08 | Supply of Winding Temperature meter for 3MVA,11KV/3.3KV Transformer | 1 | No | 26,000 ₹26,000 |
| 1.09 | Supply of Oil Temperature meter for |3MVA,11KV/3.3KV Transformer | 1 | No | 26,000 ₹26,000 |
| 1.10 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 4 | No | 13,000 ₹52,000 |
Tender Value
₹3.4 L
EMD Value
₹4,300
Closing Date
18 Mar 2026, 4:00 pmClosed
Colliery Manager (M),Manager(F),Project Engineer(E
Colliery Manager (M),Manager(F),Project Engineer(E
Changing of bushing and installation of WTI-OTI meter on 1 MVA, 11KV/550V Transformer installed at intake riverside along with installation of 11KV VCB under Kathara colliery.
2026_CCL_355925_1
KTC/PE/EnM/25-26/112 Date- 09.03.2026
Open Tender
Electrical and Maintenance Works
15 days
Office of the Projec officer, Kathara Colliery
Changing of bushing and installation of WTI-OTI meter on 1 MVA, 11KV/550V Transformer installed at intake riverside along with installation of 11KV VCB under Kathara colliery.
5 documents required · 5 mandatory
₹4,300
28 Mar 2026
9 Mar 2026
19 Mar 2026
9 Mar 2026
18 Mar 2026
9 Mar 2026
9 Mar 2026 - 14 Mar 2026
Cost of 11KV Primary busing insulator with stud
Cost of 550V secondary busing insulator with stud
Cost of copper Patti for connection (8mm x 2" x 10") of required hole size
Cost of copper Lugs of size 185sqmm
Cost of Aluminum PG clamp of required size(heavy duty), three bolt
Cost of Bimetallic clamp
Cost of Cork Sheet of size 8mm
Supply of Winding Temperature meter for 3MVA,11KV/3.3KV Transformer
Supply of Oil Temperature meter for |3MVA,11KV/3.3KV Transformer
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Repairing of fins by brazing etc.
Supply of single core Aluminium cable of size 185sqmm
Labour charges
Earthwork by mechinical/manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods,watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks,marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift: All kind of soil 1) For VCB - 0.65 mtr x (2 + 2 mtr = 4 mtr) x (1 mtr+1 mtr=2 mtr) = 5.2 CuM
Brick work with common burnt clay F.P.S (non modular) breaks of class designation 7.5 in foundation andplinth in cement mortar 1:4 (1 cement:4 coarse sand) (1) for VCB-(1Nosx(0.25mtrx2mtrx2 mtr)= 1CuM +1Nosx(0.25 mtrx2mtrx1mtr)=0.5 Cum)=1.5+0.5 Cum (for stairs)= 2 Cum
Providing and laying in position grade of reinforced specified cement exchuding concrete, the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: stone aggregate 4 graded 20 mm nominal size derived from natural sources) 1) For VCB - 1 Nos. x (0.102 mtr x 2 mtr x 1mtr) =0.204 CuM
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement: sand), finished 3 coarse with a floating coat of neat cement.18 mm thick1)1mtr For = VCB 6 Mtr- 1 No. x (2 mtr x 2 mtr +2 x + (2 mtr x 1 mtr) = 8 Sq.M
Supplying under and filling in plinth with sand floors, including watering, consolidating ramming, and dressing complete =1.125 For VCB- (1.5 mtr x 1.5 mtr 0.50 mtr) =1.125 CuM
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.99 MB
BOQ_368775.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid