EXECUTIVE ENGINEER
Room 602 BSNL Bhavan Adarsh Nagar Hyderabad
Providing repairs to EI Fans, replacement of compound lighting and pumps for staff quarters complex at Asman Mahal, Hyderabad
2024_BSNL_193747_1
02/BEDH-II/2024-25 Dated 19-04-2024
Open Tender
Electrical Works
Item Rate
60 days
HYDERABAD
Please refer Tender documents.
15 documents required · 15 mandatory
₹590
AO CASH MAIN BSNL HYDERABAD
₹6,015
3 May 2024
19 Apr 2024
30 Apr 2024
19 Apr 2024
29 Apr 2024
19 Apr 2024
Amount
Supplying, Installing, Testing and Commissioning of following rating mono submersible type pump, suitable for operation on 3 phase, 415volts, 50Hz AC supply etc., as required (a) 5HP, 3 phase. Make: Kirloskar Model: KOS-538+
Supplying and fixing of the following accessories etc.,as required. (a) 50mm dia CPVC pipe
(b) 50mm dia brass NRV
(c) 50mm dia CPVC MABT
(d) 50mm dia CPVC Bend
(e) 50mm dia CPVC Union
(f) 25mm dia CPVC ball valve
(g) 50/25mm dia CPVC 'T'
(h) 50 mm GI Nipple (6" long)
Supplying and fixing of electronic starter with controls viz., time delay, dry run protection, overload relay, MCB, display of voltage and current etc, suitable for following rating motors etc, as required. (make: GELCO DCP 3.4 DAF / OCLEG / SS) (a) 5HP, 3phase.
Supplying and laying of power supply cable of size 4x 10Sqm aluminum armoured, PVC sheathed and PVC insulated from the main panel to the pump control panel, suitable for the existing sumersible type pump set, including provding interconnections testing etc as required.
Supplying and Laying of 3C 4.0 sq mm Flat submercible Pump copper Conductor cable etc. as required.
Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 6A to 32 A Single pole
(b) 63A 4Pole isolator
Supplying and fixing of following Electrical accessories in the existing Switch board/DB Suitable for 415/240 V,50 HZ AC supply i/c removing of old, interconnections etc., complete as required. (a) 10A 1 way Modular Switch M/s Anchor Roma or SS make
(b) 10A Bell Push switch M/s Anchor Roma or SS make
(c) 10A 5Pin Modular Socket M/s Anchor Roma or SS make
(d) Stepped Fan Modular Regulator M/s Anchor Roma (2 switch width) or SS make
(e) 6A/16A 6 pin Modular Socket M/s Anchor Roma or SS make
(f) 20A 1 way Modular Switch M/s Anchor Roma or SS make
(g) 32A D.P. Modular Main Switch With Key Ring Tag(1main + 1 spare) M/s Anchor Roma or SS make
(h) 2 way Modular Plate along with inner frame M/s Anchor Roma or SS make
(i) 3 way Modular Plate along with inner frame M/s Anchor Roma or SS make
(j) 8 way Modular Plate along with inner frame M/s Anchor Roma or SS make
(k) 12 way Modular Plate along with inner frame M/s Anchor Roma or SS make
(l) 18 way Modular Plate along with inner frame M/s Anchor Roma or SS make
(m) 2 module PVC box
(n) 3 module PVC box
(o) 8 module PVC box
(p) 12 module PVC box
(q) 18 module PVC box
Supplying and fixing FP sheet steel enclosure on surface/ recess along with 32amps 415 volts "C" curve FP MCB complete with connections, testing and commissioning etc. as required.
Chipping of cement concrete road for laying of cable including removing the debris, supplying and laying of 40mm dia B-Class GI pipe, making good the damages done to the road, flooring refilling the trench with cement concrete mixture etc as required.
Suppying and fixing 48" dia sweep ceiling fans including interconnections, testing, removing of faulty etc., as required.
Providing Wheel Self Supporting Extension Industrial Aluminium Ladder heavy duty type 20ft height for repair of compound lights in various quarters.
Providing, installing and testing of the following for compound light items i/c removing the faulty and interconnections etc.,as required. (a) 30W LED street light fitting (Make; CG/ ss make)
Weather proof pole boxes along with 6A connector and 6A SP MCB
Supplying and fixing of 25mm dia GI bracket for mounting the LED type fitting including fixing the bracket on the surface of wall, etc as required
Gate light fittings with B 22 holder type & 26 W LED bulb etc.
Supplying and fixing of 2 core 1.5 sq mm round copper conductor flexible wire from pole box to street light fitting etc., as required.
Supplying and fixing of 63A TP&N disconnector fuse switch unit with suitable SS enclosure and ISI marked HRC fuses etc. as required
Supplying and fixing of 63A TPN FN TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer) as required. (a) 4 way (4 + 12)
Supplying and fixing 63A, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 32A Triple pole
Providing servicing to the existing Cleaning feeder pillar box by checking all the connections, cleaning the rust with emry paper, with enamel paint touch up wherever required etc., as required.
Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit includingdismantling as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 2 x 1.5 sq. mm
(b) 4 x 1.5 sq. mm
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 2 way 5/6 amps switch
Supplying and fixing of bulk head type of fitting suitable for operation on 230volts single phase, 50Hz AC supply including supplying and fixing of 25watts LED type bulb etc as required.
V S ELECTRICAL WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .