Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 CrAccepted-AOC | ₹11.4 Cr Quoted ₹15.4 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹15.6 CrRejected-AOC | ₹15.6 Cr | L2 | Rejected-AOC L2 |
Tender Value
₹11.4 Cr
EMD Value
₹22.8 L
Closing Date
6 Jan 2023, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Renovation And Modernization of Tai Museum at Sivasagar
2022_PWBNH_28416_1
CE/TB-VI/96/2022/06 Dated Guwahati 20th Dec 2022
Open Tender
Civil Works - Building
545 days
Sivasagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹20,000
₹22.8 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
6 Mar 2023
23 Dec 2022
7 Jan 2023
23 Dec 2022
6 Jan 2023
28 Dec 2022
27 Dec 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1:3:6( 1 Cement:3 Couse sand (n zone -III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form for Arches,domes, vaults exceeding 6 m span
Centering and shuttering including strutting, propping etc. and removal of form for Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards
Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. Granite of any colour and shade
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood 50 x 20 mm
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing bright finished brass handles with screws etc. complete: 125 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
GYPSUM BOARD PARTITIONS 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster boardconforming to IS: 2095: part 3 (Board with BIS certification marks)
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm)
Two track four panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 8.00 sqm upto 10.00 sqm).
Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Dry brick pitching halfbrick thick indrains including supply of bricks and preparing the surface complete.with common brunt clay F.P.S ( non modular) Bricks of class 7.5
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
CEMENT PLASTER (IN COARSE SAND) 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)
CEMENT PLASTER (IN COARSE SAND) External Wall 20 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
White washing with lime to give an even shade: New work (three or more coats)
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : Of sectional area 40 square centimetres and above
Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead :
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Square shape 450 mm internal dimensions
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 450 mm dia piles
Single pile above 50 tonne and upto 100 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powdercoating 50 micron)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Polyester powder coated minimum thickness 50 micron aluminium
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required Single half stall urinal with 5 litre P.V.C automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
Providing and fixing 100 mm sand cast Iron grating for gully trap.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing SS Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work 32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work50 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work 80 mm nominal inner dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15mm nominal bore
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : with common burnt F.P.S. (Non modular) bricks of class designation 7.5
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge
Supplying, fitting and fixing Chrome Plated (C.P.) rain water shower 200X200 mm dia of approved brand as directed and specified. (Pipes will be measured and paid separately)
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.
Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified.
Providing, fitting and fixing CP towel rail complete as directed and specified.
Providing, fitting and fixing robe hook complete as directed and specified.
Providing, fitting and fixing Chrome Plated health faucet complete as directed and specified.
Supplying fiting and fixing glass division plate including fitting and fixing compete as directed and specified.
Providing and fixing under counter wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: white Vitreous China Under Counter Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing CP bib cock of approved qualiity
Providing and fixing CP grating of approved quality and colour
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince)or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 75 mm nominal outer dia Pipes
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince)or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110 mm nominal outer dia Pipes
Supplying, fitting and fixing PVCaccessories of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. 75 mm nominal outer dia Pipes Coupler
Supplying, fitting and fixing PVCaccessories of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. 75 mm nominal outer dia Pipes 87.5 bend
Supplying, fitting and fixing PVCaccessories of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. 75 mm nominal outer dia Pipes 87.5 bend with door
Supplying, fitting and fixing PVCaccessories of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. 75 mm nominal outer dia Pipes Single T
Supplying, fitting and fixing PVCaccessories of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. 75 mm nominal outer dia Pipes .Single T with door
Supplying, fitting and fixing PVCaccessories of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified.75 mm nominal outer dia Pipes Double T
Supplying, fitting and fixing PVCaccessories of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified.75 mm nominal outer dia Pipes 45 Bend
Supplying, fitting and fixing PVCaccessories of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified.75 mm nominal outer dia Pipes Reducing Y 110 x 75
Supplying, fitting and fixing PVCaccessories of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified.75 mm nominal outer dia Pipes Cowel
Supplying, fitting and fixing PVC accessories of 6 Kg/cm2 (Supreme/Prince)or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110 mm nominal outer dia Pipes Coupler
Supplying, fitting and fixing PVC accessories of 6 Kg/cm2 (Supreme/Prince)or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110 mm nominal outer dia Pipes 87.5 bend
Supplying, fitting and fixing PVC accessories of 6 Kg/cm2 (Supreme/Prince)or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110 mm nominal outer dia Pipes 87.5 bend with door
Supplying, fitting and fixing PVC accessories of 6 Kg/cm2 (Supreme/Prince)or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110 mm nominal outer dia Pipes Single T
Supplying, fitting and fixing PVC accessories of 6 Kg/cm2 (Supreme/Prince)or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110 mm nominal outer dia Pipes Single T with door
Supplying, fitting and fixing PVC accessories of 6 Kg/cm2 (Supreme/Prince)or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110 mm nominal outer dia Pipes Double T
Supplying, fitting and fixing PVC accessories of 6 Kg/cm2 (Supreme/Prince)or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110 mm nominal outer dia Pipes 45 Bend
Supplying, fitting and fixing PVC accessories of 6 Kg/cm2 (Supreme/Prince)or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110 mm nominal outer dia Pipes Reducing Y 160 X 110
Supplying, fitting and fixing PVC accessories of 6 Kg/cm2 (Supreme/Prince)or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110 mm nominal outer dia Pipes Cowel
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 ( 1cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size )
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 400 mm dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
Supply, Lowering, installation & testing of KSB make submersible pumping set with 25 HP to 30 HP motor 4/5 stage pump suitable for 45-60 m3 hr. at 60 to 100 mtr. Head respectively. With Three Phase.
Providing & fixing submersible copper cable 10 sq.mm. from submersible pump to panel board.
Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet.
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment).
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Providing and wartering of irrigation water through water tanker of Horticulture features i.e. lawn, tree, shrubs, hedge/edge, ground cover etc. at the site of work. Water tanker having 5000 lit. capacity with one labour for watering i/c cost of water, filling of tanker, wartering at site with all leads and lifts as per direction of officer-in-charge.
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Trees Plant
Hedge Plant /Ground cover
Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge..
Providing and stacking of Iresine herbstii, of height 20-25 cm. full of branches well developed in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v
Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Bottle palm of ht. 210-240 cm bottom girth 30-35 cm well developed in big HDPE bags.
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date as well as APDCL approved brand. All Transportation, handling and necessary liaison with APDCL / CEIA, Assam will have to be made as directed and specified by the Department.11/0.4KV 250KVA DTR Copper wound - BIS Level - 2
Construction of RCC Transformer PAD as per Specification & Design of this department complete as directed by the department.
Load Security to be paid to APDCL
Supplying and fixing of 11 KV 150 A D.O. fuse set assembly complete as required and as directed by the department and brand as approved by APDCL
Supplying and fixing of 11 KV 150A Gang Operated Switch as required and directed by the department and brand as Approved by APDCL
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required and directed by the department
Supplying with fitting and fixing of P.G. clamp for Racoon conductor complete as required and as directed by the department.
Supplying and string up ACSR Racoon conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department and brand as per approved by APDCL
Supplying, fitting and fixing of GI 11KV T Cross Arm with angle size 50x50x6mm
Supplying, fitting and fixing of GI Channel Cross Arm (100x50x6x2200mm)
Supplying with fitting and fixing of H.T. danger plate complete as required and as directed by the department.
Supplying, erection and commissioning of GI Steel Tubular Pole SP-30 (9.00 meter height) for OH HT Line
Supplying, erection and commissioning of GI Steel Tubular Pole SP-30 (12.00 meter height) for Distribution Substation
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.00 metre and upto 10.00 metre
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Supplying of GI Strip 50x6 mm for Distribution transformer neutral earthing
Supplying of 3.5C x 300 sq.mm. sq mm Armoured LT cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm upto 400 sq.Mm
Supplying and installation of 11kv grade (HT) 1 core x 95 sq mm Armoured cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm (70mm)
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. Mm
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required and directed by the department and brand as per approved by APDCL 315 A, 35 KA,TPMCCB
Supplying, fitting and fixing of Metering Cabinet as required and directed by the department
Payment to be made to APDCL authority for supply and installation of Tri-vector Meter & CTPT combined as directed by this department
Supplying including installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f. mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) Standard Control Panel.5) Suitable batteries with lead.,6) First fill of lube oil.,7) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KVA).Cummins Power Generator. 160 KVA , 3 phase, Liquid cool, 1500 rpm DG set alongwith AMF Panel with necessary connections made as directed by the Department
Construction of RCC Diesel Generator PAD as per Specification & Design of this department complete as directed by the department.(Transformer pad for 2.5MVA complete as per specification)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 4 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 32 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2 way 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor,single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required .Upto 450 mm sweep
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 A,36KA,FPMCCB
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and ommissioning etc. as required. Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. without charcoal/ coke and salt as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying, installation, testing and Commission of the following indoor Decorative Recess mounted LED down lighter luminaries of 18W Led Recessed Luminaire Philips complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips/Crompton / LT / Wipro make).18 W Recessed LED Down Light
Supplying including fitting fixing of 230 MM POLYCAB Make AIR EXHAUST FAN in the existing hole on the wall of following sweeps with making necessary connection as required complete
Supplying with fitting fixing of ,250 A “AA” Frame FP MCCB, Legrand or equivalent make.
Supplying including Installation, testing and commissioning of ceiling fan, 1400 mm sweep including necessary connection as required complete and as directed by the department.
Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 4 Core 25 sqmm Al armoured xlpe cable.
Supply,Installation, Testing and Commissioning of Variable Refrigerant Volume type multi unit air-conditioning system complete with indoor and outdoor units with individual controller for cooling & heating type operations.The quoted price should include cost of all material, consumable, all taxes, labour, commissioning etc. (Approved makes : Mitsubishi/Daikin/Toshiba) Supply , installation , testing and commissioning of Variable Refrigerant Volume Outdoor Unit complete with hermitically sealed scroll compressor as per following nominal capacities complete with protective coated fins, mounting frame, casing, microproccessor panel, and other standard accessories : i) Microproccessor panel , ii) First charge of refirigerant R 410A , iii) Protective coated fins iv)Mounting frame with isolation pad , all required accessories, structural support and civil foundation. v) Interconnecting Pipes for Liquit, Discharge and Suction vi) Interconnecting Cables and Earthing from nearest given point . The outdoor unit should be fitted with low noise, aero spiral design fan with minimum External Static Pressure of 75 Pa for easy discharge of Hot air, aero fitting grille, to reduce pressure loss. Capacity: 12 HP (Cooling Only)
Supply,Installation, Testing and Commissioning of Variable Refrigerant Volume type multi unit air-conditioning system complete with indoor and outdoor units with individual controller for cooling & heating type operations.The quoted price should include cost of all material, consumable, all taxes, labour, commissioning etc. (Approved makes : Mitsubishi/Daikin/Toshiba) Supply , installation , testing and commissioning of Variable Refrigerant Volume Outdoor Unit complete with hermitically sealed scroll compressor as per following nominal capacities complete with protective coated fins, mounting frame, casing, microproccessor panel, and other standard accessories : i) Microproccessor panel , ii) First charge of refirigerant R 410A , iii) Protective coated fins iv)Mounting frame with isolation pad , all required accessories, structural support and civil foundation. v) Interconnecting Pipes for Liquit, Discharge and Suction vi) Interconnecting Cables and Earthing from nearest given point . The outdoor unit should be fitted with low noise, aero spiral design fan with minimum External Static Pressure of 75 Pa for easy discharge of Hot air, aero fitting grille, to reduce pressure loss. Capacity: 28 HP (Cooling Only)
Supply,Installation, Testing and Commissioning of Variable Refrigerant Volume type multi unit air-conditioning system complete with indoor and outdoor units with individual controller for cooling & heating type operations.The quoted price should include cost of all material, consumable, all taxes, labour, commissioning etc. (Approved makes : Mitsubishi/Daikin/Toshiba) Supply , installation , testing and commissioning of Variable Refrigerant Volume Outdoor Unit complete with hermitically sealed scroll compressor as per following nominal capacities complete with protective coated fins, mounting frame, casing, microproccessor panel, and other standard accessories : i) Microproccessor panel , ii) First charge of refirigerant R 410A , iii) Protective coated fins iv)Mounting frame with isolation pad , all required accessories, structural support and civil foundation. v) Interconnecting Pipes for Liquit, Discharge and Suction vi) Interconnecting Cables and Earthing from nearest given point . Capacity: 40 HP (Cooling Only)
Supply,Installation, Testing and Commissioning of Variable Refrigerant Volume type multi unit air-conditioning system complete with indoor and outdoor units with individual controller for cooling & heating type operations.The quoted price should include cost of all material, consumable, all taxes, labour, commissioning etc. (Approved makes : Mitsubishi/Daikin/Toshiba) Supply , installation , testing and commissioning of Variable Refrigerant Volume Outdoor Unit complete with hermitically sealed scroll compressor as per following nominal capacities complete with protective coated fins, mounting frame, casing, microproccessor panel, and other standard accessories : i) Microproccessor panel , ii) First charge of refirigerant R 410A , iii) Protective coated fins iv)Mounting frame with isolation pad , all required accessories, structural support and civil foundation. v) Interconnecting Pipes for Liquit, Discharge and Suction vi) Interconnecting Cables and Earthing from nearest given point .The outdoor unit should be fitted with low noise, aero spiral design fan with minimum External Static Pressure of 75 Pa for easy discharge of Hot air, aero fitting grille, to reduce pressure loss. Capacity: 46 HP (Cooling Only)
SITC of VRF Evaporating (Indoor) Units Complete with single phase/ three phase low-noise centrifugal fan, cooling coil, filter, electronic expansion valve & Y Joints with wired remote control inlcuidng connecting the indoor unit with a power cable & plug top to power point provided near the unit (including Canvas Connection) Supply , installation , testing and commissioning of Indoor VRV 4 -Way Cassette Unit as per following nominal capacities complete withi) Expansion and mixing arrangements ii) Power Supply interconnections iii) Controlling interconections iv) Piping interconnections v) Supending accessories vi) Insulated Drain pipe line vii) with wireless remote Capacity: 1.3 HP
Complete with single phase/ three phase low-noise centrifugal fan, cooling coil, filter, electronic expansion valve & Y Joints with wired remote control inlcuidng connecting the indoor unit with a power cable & plug top to power point provided near the unit (including Canvas Connection) Supply , installation , testing and commissioning of Indoor VRV 4 -Way Cassette Unit as per following nominal capacities complete with i) Expansion and mixing arrangements ii) Power Supply interconnections iii) Controlling interconections iv) Piping interconnections v) Supending accessories vi) Insulated Drain pipe line vii) with wireless remote Capacity: 2.5 HP
Complete with single phase/ three phase low-noise centrifugal fan, cooling coil, filter, electronic expansion valve & Y Joints with wired remote control inlcuidng connecting the indoor unit with a power cable & plug top to power point provided near the unit (including Canvas Connection) Supply , installation , testing and commissioning of Indoor VRV 4 -Way Cassette Unit as per following nominal capacities complete with i) Expansion and mixing arrangements ii) Power Supply interconnections iii) Controlling interconections iv) Piping interconnections v) Supending accessories vi) Insulated Drain pipe line vii) with wireless remote Capacity: 3.2 HP
Complete with single phase/ three phase low-noise centrifugal fan, cooling coil, filter, electronic expansion valve & Y Joints with wired remote control inlcuidng connecting the indoor unit with a power cable & plug top to power point provided near the unit (including Canvas Connection) Supply , installation , testing and commissioning of Indoor VRV 4 -Way Cassette Unit as per following nominal capacities complete with i) Expansion and mixing arrangements ii) Power Supply interconnections iii) Controlling interconections iv) Piping interconnections v) Supending accessories vi) Insulated Drain pipe line vii) with wireless remote Capacity: 4.0 HP
Supply , installation , testing and commissioning of Indoor VRV 1 -Way Cassette Unit as per following nominal capacities complete with i) Expansion and mixing arrangements ii) Power Supply interconnections iii) Controlling interconections iv) Piping interconnections v) Supending accessories vi) Insulated Drain pipe line vii) with wireless remote Capacity: 1.3 HP
Supply , installation , testing and commissioning of Indoor VRV 1 -Way Cassette Unit as per following nominal capacities complete with i) Expansion and mixing arrangements ii) Power Supply interconnections iii) Controlling interconections iv) Piping interconnections v) Supending accessories vi) Insulated Drain pipe line vii) with wireless remote Capacity: 2.0 HP
Supply , installation , testing and commissioning of Indoor VRV 1 -Way Cassette Unit as per following nominal capacities complete with i) Expansion and mixing arrangements ii) Power Supply interconnections iii) Controlling interconections iv) Piping interconnections v) Supending accessories vi) Insulated Drain pipe line vii) with wireless remote Capacity: 2.5 HP
SITC of Refrigerant Piping For VRF SystemHard drawn copper piping in brazed construciton, complete with O class nitrile rubber insulation, supports/suspenders, as per enclosed specifications. Minimum wall thickness of copper refrigerant pipes shall be as per Copper pipe-ASTM B88, L-Type standard. Approved Makes: i)Copper Refrigerent Pipe- Rajco / Maxflow / Nissan ii)Nitrile Insulation - Armaflex / K Flex / A- Flex / Superlon
Supply, Installation, Testing & Commissioining of Shielded control cum transmission cabling between ODU & IDU 2 X 2C X 1.0 Sqmm Cu Cable in Riggid PVC Conduit duly supported and saddled as per specification & as directed by the consultant. (note : it is important to lay one spare cable for redundancy)
Providing and fixing condensate drain piping with 25mm u-PVC pipe with 9mm thick nitrile tube insulation of following sizes including making wall chases to completely embedd the pipes inside the wall, making good the wall cut and finally finishing with POP to good finish. One end on the pipe will be connected to the indoor unit of the air conditioner /AHUand the other end will be terminated to the nearest apron drain or suitable termination drain pipe complete with all fittings and support etc complete in all respect as directed by the engineer. (Supreme/Ashirvad/Astral)
Supply and installation of Fabric Covered wood wool panel of size 1200 x 600 x 20mm mounted on supplied G I Frame work consisting of basic profile, main profile & edge profile. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C . The frame work shall wood wool panel will be back lined by using 50MM polyester wool having a density of 1000 GSM and 50mm thick.
Supply and installation of FR grade 150mm wide 12mm thick Laminated plywood (150mm wide slat and 3mm gap between 150mm wide plywood) backed with 50mm thick 1000GSM polyester wool. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C .
Supply and installation of 600X 600 x15mm thk Grid Ceiling Area having density 15 mm (c. 4.5 kg/m2) , NRC upto 0.70, Reaction to fire, : A2-s1, d0 as per EN 13501-1, Sound attenuation: Dn,c,w = 34 dB as per EN 20140-9 (15 mm thickness, according to test certificate). Frame work shall consists of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm) fixed along with perimeter of the gypsum or walls with the help of nylon sleeves and screws at 600mm c/c. Then suspend GI main channels of size 45 mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1200mm c/c by using soffit angle of size 25mm x 10mm x 0.55mm thick fixed to true ceiling by using suitable fasteners. Cross channels of size 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the main channel with the help of connecting clips and in a direction perpendicular to the main channel at 300mm c/c .
Supply and Installation of Carpet Flooring. Carpet Type:- Loop Pile, Pile Content:- 100% Polypropylene (SD), Primary Backing:- Woven PP, Secondary Backing:- Felt Backing, Pile Weight:- 850gsm, Total Weight:- 1850gsm, Pile height:- 5.0mm, Total Height:- 8.0mm, Number of knots:- 65520 tufts/ Sq. Mtr, Width:- 400 cm, Light Fastness:- 5/5 on Grey Scale, Fire Class:- Pass 8/8.
Supplying installation, testing, programming and commissioning of Audio equipment ON TABLE BOUNDARY MICROPHONE for any conferencing system: Frequency response 40 Hz – 20 kHz, Nominal impedance 200 Ω, Sensitivity 10 mV/Pa. Frequency Response :- 40 Hz - 20 kHz, Max. sound pressure level:- 140 dB, Sensitivity :- 10 mV/Pa, Dynamic range :- 111 dB (A) (Make:- Sennheiser/ Audio Technica/ Shure)
Supply, Installation, Testing and Commissioning of DSP core with 16 user-configured card slots, Lua scripting engine, optional software-licensed HearClear AEC. (Make:- Xilica/ Biamp/ Clearone)
Supply, Installation, Testing and Commissioning of Analog Input Card having 2 Mic/ Line Inputs. (Make:- Xilica/ Biamp/ BSS)
Supply, Installation, Testing and Commissioning of Analog Output Card having 2 Mic/ Line Outputs. (Make:- Xilica/ Biamp/ BSS)
Supply, Installation, Testing and Commissioning of USB I/O Card (Make:- Xilica/ Biamp/ BSS)
Supplying installation, testing, programming and commissioning of Popup Box; Easy Access To Connectors, One Female 15pin HD Connector And 3.5mm Mini Stereo Audio Jack, Two CAT RJ45 Network/Data/Phone Connectors, Two Unswitched AC Outputs, One HDMI (Make:- Magnum/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of Audio equipment,8" Open‐Back Ceiling Speaker. 70V/100V taps at 6W, 3W, 1.5W (plus 0.75W at 70V), very high 97 dB sense, 50 Hz to 16 kHz, for non‐plenum applications, 1.4 kg (3.0 l. (Make:- JBL/ Apart Audio/ Bosch)
Supplying installation, testing, programming and commissioning of 8Ch Power Amplifier. Signal to Noise Ratio (below rated power 20Hz to 20kHz, A-Weighted):- 110dB, Total Harmonic Distortion (THD) (full rated power, 20Hz - 20kHz):- <0.05%, ntermodulation Distortion (from 0dB down to -30dB):- <0.05%. (Make:- Crown/ Labgruppen/ Powersoft)
Supply, Installation, Testing and Programming of 11th Gen Intel Core i5 Processor 15.6 inches FHD Laptop, 8GB/512GB SSD/Windows 10/2GB MX350 Graphics. (Make:- HP/ Dell/ Acer)
Supply and Laying of Audio Signal/ Microphone Cable (Make:- Gotham/ Klotz/ Belden)
Supply and Laying of Audio Speaker Cable (Make:- Gotham/ Klotz/ Belden/ Finolex)
Supply and Installation of Audio Connectors like XLR, RCA, Mono Jack etc (Make:- Amphenol/ Neutrik)
Supply and Installation of 17/18U Floor Mounted Equipment Rack with Castor Wheels (Make:- Nettrack/ Valrack/ Linkeu)
Supply and Installatoin of 6KVA Online UPS with SMF Batteries, Battery Rack and Interconnects (Make:- Numeric/ Delta/ APC)
Supplying installation, testing, programming and commissioning of 100" 4K Ultra HD HDR Professional Display. Brightness (cd/m2):- Typical: 600, Peak: 940, Contrast Ratio:- 9000:1, Backlight Type:- Direct LED, HDR Compatibility:- HDR10 / HLG / Dolby Vision. (Make:- LG/ Panasonic/ Sony)
Supplying installation, testing, programming and commissioning of 4K60 4:2:0 HDMI HDCP 2.2 Transmitter with RS–232 & IR over Long–Reach HDBaseT. INPUTS:- 1 HDMI on an HDMI connector, OUTPUTS:- 1 HDBT on an RJ–45 female connector, VIDEO:- Up to 10.2Gbps bandwidth (3.4Gbps per graphic channel), Up to 4K UHD @60Hz (4:2:0) 24bpp resolution (Make:- Kramer/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of 4K60 4:2:0 HDMI HDCP 2.2 Receiver with RS–232 & IR over Long–Reach HDBaseT. INPUTS:- 1 HDBT on an RJ–45 female connector, OUTPUTS:- 1 HDMI on an HDMI connector, VIDEO:- Up to 10.2Gbps bandwidth (3.4Gbps per graphic channel), Up to 4K UHD @60Hz (4:2:0) 24bpp resolution, HDCP 2.2 signal compliance (Make:- Kramer/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of 4K HDR HDMI Audio De–embedder. AUDIO: Frequency Response: 20Hz to 20kHz @ +/–0.1dB S/N Ratio: >90dB, THD+N: 0.004%, VIDEO: Bandwidth: Up to 18Gbps (6Gbps per graphic channel), Max. Resolution: Up to 4K@60 (4:4:4), HDMI Support: 4K@60Hz and ARC as specified in HDMI 2.0, Content Protection: Supports HDCP 2.2 (Make:- Kramer/ Extron/ Atlona)
Supply and Installation of HDMI to HDMI Cable Length 10M (Make:- Kramer/ Extron/ Atlona)
Supply and installation of Acoustic Panels 12mm: Performance: Sound Absorption coefficients 0.03- 0.8 (frequency 125 hz to 4000 hz), Material: Polyester Panel. Formaldehyde free, No odour, 100 % recyclable. The Acoustic panels to be fixed on 6MM Plywood which will be fixed on to surface of the Wall.
Supply and installation of FR grade 150mm wide 12mm thick Laminated plywood (150mm wide slat and 3mm gap between 150mm wide plywood) backed with 50mm thick 1000GSM polyester wool. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C .
Supply and installation of 600X 600 x15mm thk Grid Ceiling Area having density 15 mm (c. 4.5 kg/m2) , NRC upto 0.70, Reaction to fire, : A2-s1, d0 as per EN 13501-1, Sound attenuation: Dn,c,w = 34 dB as per EN 20140-9 (15 mm thickness, according to test certificate). Frame work shall consists of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm) fixed along with perimeter of the gypsum or walls with the help of nylon sleeves and screws at 600mm c/c. Then suspend GI main channels of size 45 mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1200mm c/c by using soffit angle of size 25mm x 10mm x 0.55mm thick fixed to true ceiling by using suitable fasteners. Cross channels of size 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the main channel with the help of connecting clips and in a direction perpendicular to the main channel at 300mm c/c .
Supply and Installation of Carpet Flooring. Carpet Type:- Loop Pile, Pile Content:- 100% Polypropylene (SD), Primary Backing:- Woven PP, Secondary Backing:- Felt Backing, Pile Weight:- 850gsm, Total Weight:- 1850gsm, Pile height:- 5.0mm, Total Height:- 8.0mm, Number of knots:- 65520 tufts/ Sq. Mtr, Width:- 400 cm, Light Fastness:- 5/5 on Grey Scale, Fire Class:- Pass 8/8.
Supply and installation of Fabric Covered wood wool panel of size 1200 x 600 x 20mm mounted on supplied G I Frame work consisting of basic profile, main profile & edge profile. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C . The frame work shall wood wool panel will be back lined by using 50MM polyester wool having a density of 1000 GSM and 50mm thick.
Supply and installation of FR grade 150mm wide 12mm thick Laminated plywood (150mm wide slat and 3mm gap between 150mm wide plywood) backed with 50mm thick 1000GSM polyester wool. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C .
Supply and installation of 600X 600 x15mm thk Grid Ceiling Area having density 15 mm (c. 4.5 kg/m2) , NRC upto 0.70, Reaction to fire, : A2-s1, d0 as per EN 13501-1, Sound attenuation: Dn,c,w = 34 dB as per EN 20140-9 (15 mm thickness, according to test certificate). Frame work shall consists of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm) fixed along with perimeter of the gypsum or walls with the help of nylon sleeves and screws at 600mm c/c. Then suspend GI main channels of size 45 mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1200mm c/c by using soffit angle of size 25mm x 10mm x 0.55mm thick fixed to true ceiling by using suitable fasteners. Cross channels of size 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the main channel with the help of connecting clips and in a direction perpendicular to the main channel at 300mm c/c .
Supply and Installation of Carpet Flooring. Carpet Type:- Loop Pile, Pile Content:- 100% Polypropylene (SD), Primary Backing:- Woven PP, Secondary Backing:- Felt Backing, Pile Weight:- 850gsm, Total Weight:- 1850gsm, Pile height:- 5.0mm, Total Height:- 8.0mm, Number of knots:- 65520 tufts/ Sq. Mtr, Width:- 400 cm, Light Fastness:- 5/5 on Grey Scale, Fire Class:- Pass 8/8.
Supplying installation, testing, programming and commissioning of Audio equipment ON TABLE BOUNDARY MICROPHONE for any conferencing system: Frequency response 40 Hz – 20 kHz, Nominal impedance 200 Ω, Sensitivity 10 mV/Pa. Frequency Response :- 40 Hz - 20 kHz, Max. sound pressure level:- 140 dB, Sensitivity :- 10 mV/Pa, Dynamic range :- 111 dB (A) (Make:- Sennheiser/ Audio Technica/ Shure)
Supply, Installation, Testing and Commissioning of DSP core with 16 user-configured card slots, Lua scripting engine, optional software-licensed HearClear AEC. (Make:- Xilica/ Biamp/ Clearone)
Supply, Installation, Testing and Commissioning of Analog Input Card having 2 Mic/ Line Inputs. (Make:- Xilica/ Biamp/ BSS)
Supply, Installation, Testing and Commissioning of Analog Output Card having 2 Mic/ Line Outputs. (Make:- Xilica/ Biamp/ BSS)
Supply, Installation, Testing and Commissioning of USB I/O Card (Make:- Xilica/ Biamp/ BSS)
Supplying installation, testing, programming and commissioning of Popup Box; Easy Access To Connectors, One Female 15pin HD Connector And 3.5mm Mini Stereo Audio Jack, Two CAT RJ45 Network/Data/Phone Connectors, Two Unswitched AC Outputs, One HDMI (Make:- Magnum/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of Audio equipment,8" Open‐Back Ceiling Speaker. 70V/100V taps at 6W, 3W, 1.5W (plus 0.75W at 70V), very high 97 dB sense, 50 Hz to 16 kHz, for non‐plenum applications, 1.4 kg (3.0 l. (Make:- JBL/ Apart Audio/ Bosch)
Supplying installation, testing, programming and commissioning of 8Ch Power Amplifier. Signal to Noise Ratio (below rated power 20Hz to 20kHz, A-Weighted):- 110dB, Total Harmonic Distortion (THD) (full rated power, 20Hz - 20kHz):- <0.05%, ntermodulation Distortion (from 0dB down to -30dB):- <0.05%. (Make:- Crown/ Labgruppen/ Powersoft)
Supply, Installation, Testing and Programming of 11th Gen Intel Core i5 Processor 15.6 inches FHD Laptop, 8GB/512GB SSD/Windows 10/2GB MX350 Graphics. (Make:- HP/ Dell/ Acer)
Supply and Laying of Audio Signal/ Microphone Cable (Make:- Gotham/ Klotz/ Belden)
Supply and Laying of Audio Speaker Cable (Make:- Gotham/ Klotz/ Belden/ Finolex)
Supply and Installation of Audio Connectors like XLR, RCA, Mono Jack etc (Make:- Amphenol/ Neutrik)
Supply and Installation of 17/18U Floor Mounted Equipment Rack with Castor Wheels (Make:- Nettrack/ Valrack/ Linkeu)
Supply and Installatoin of 6KVA Online UPS with SMF Batteries, Battery Rack and Interconnects (Make:- Numeric/ Delta/ APC)
Supplying installation, testing, programming and commissioning of 100" 4K Ultra HD HDR Professional Display. Brightness (cd/m2):- Typical: 600, Peak: 940, Contrast Ratio:- 9000:1, Backlight Type:- Direct LED, HDR Compatibility:- HDR10 / HLG / Dolby Vision. (Make:- LG/ Panasonic/ Sony)
Supplying installation, testing, programming and commissioning of 4K60 4:2:0 HDMI HDCP 2.2 Transmitter with RS–232 & IR over Long–Reach HDBaseT. INPUTS:- 1 HDMI on an HDMI connector, OUTPUTS:- 1 HDBT on an RJ–45 female connector, VIDEO:- Up to 10.2Gbps bandwidth (3.4Gbps per graphic channel), Up to 4K UHD @60Hz (4:2:0) 24bpp resolution (Make:- Kramer/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of 4K60 4:2:0 HDMI HDCP 2.2 Receiver with RS–232 & IR over Long–Reach HDBaseT. INPUTS:- 1 HDBT on an RJ–45 female connector, OUTPUTS:- 1 HDMI on an HDMI connector, VIDEO:- Up to 10.2Gbps bandwidth (3.4Gbps per graphic channel), Up to 4K UHD @60Hz (4:2:0) 24bpp resolution, HDCP 2.2 signal compliance (Make:- Kramer/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of 4K HDR HDMI Audio De–embedder. AUDIO: Frequency Response: 20Hz to 20kHz @ +/–0.1dB S/N Ratio: >90dB, THD+N: 0.004%, VIDEO: Bandwidth: Up to 18Gbps (6Gbps per graphic channel), Max. Resolution: Up to 4K@60 (4:4:4), HDMI Support: 4K@60Hz and ARC as specified in HDMI 2.0, Content Protection: Supports HDCP 2.2 (Make:- Kramer/ Extron/ Atlona)
Supply and Installation of HDMI to HDMI Cable Length 10M (Make:- Kramer/ Extron/ Atlona)
Supply and installation of Acoustic Panels 12mm: Performance: Sound Absorption coefficients 0.03- 0.8 (frequency 125 hz to 4000 hz), Material: Polyester Panel. Formaldehyde free, No odour, 100 % recyclable. The Acoustic panels to be fixed on 6MM Plywood which will be fixed on to surface of the Wall.
Supply and installation of FR grade 150mm wide 12mm thick Laminated plywood (150mm wide slat and 3mm gap between 150mm wide plywood) backed with 50mm thick 1000GSM polyester wool. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C .
Supply and installation of 600X 600 x15mm thk Grid Ceiling Area having density 15 mm (c. 4.5 kg/m2) , NRC upto 0.70, Reaction to fire, : A2-s1, d0 as per EN 13501-1, Sound attenuation: Dn,c,w = 34 dB as per EN 20140-9 (15 mm thickness, according to test certificate). Frame work shall consists of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm) fixed along with perimeter of the gypsum or walls with the help of nylon sleeves and screws at 600mm c/c. Then suspend GI main channels of size 45 mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1200mm c/c by using soffit angle of size 25mm x 10mm x 0.55mm thick fixed to true ceiling by using suitable fasteners. Cross channels of size 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the main channel with the help of connecting clips and in a direction perpendicular to the main channel at 300mm c/c .
Supply and installation of Fabric Covered wood wool panel of size 1200 x 600 x 20mm mounted on supplied G I Frame work consisting of basic profile, main profile & edge profile. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C . The frame work shall wood wool panel will be back lined by using 50MM polyester wool having a density of 1000 GSM and 50mm thick.
Supply and installation of FR grade 150mm wide 12mm thick Laminated plywood (150mm wide slat and 3mm gap between 150mm wide plywood) backed with 50mm thick 1000GSM polyester wool. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C .
Supply and installation of 600X 600 x15mm thk Grid Ceiling Area having density 15 mm (c. 4.5 kg/m2) , NRC upto 0.70, Reaction to fire, : A2-s1, d0 as per EN 13501-1, Sound attenuation: Dn,c,w = 34 dB as per EN 20140-9 (15 mm thickness, according to test certificate). Frame work shall consists of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm) fixed along with perimeter of the gypsum or walls with the help of nylon sleeves and screws at 600mm c/c. Then suspend GI main channels of size 45 mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1200mm c/c by using soffit angle of size 25mm x 10mm x 0.55mm thick fixed to true ceiling by using suitable fasteners. Cross channels of size 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the main channel with the help of connecting clips and in a direction perpendicular to the main channel at 300mm c/c .
Supply and Installation of Carpet Flooring. Carpet Type:- Loop Pile, Pile Content:- 100% Polypropylene (SD), Primary Backing:- Woven PP, Secondary Backing:- Felt Backing, Pile Weight:- 850gsm, Total Weight:- 1850gsm, Pile height:- 5.0mm, Total Height:- 8.0mm, Number of knots:- 65520 tufts/ Sq. Mtr, Width:- 400 cm, Light Fastness:- 5/5 on Grey Scale, Fire Class:- Pass 8/8.
Supplying installation, testing, programming and commissioning of Passive Column Array Loudspeaker with 7 Mid Range Drivers and FAST Dispersion Control for Installation Applications (EN 54 Certified),7 x 3.5" full range drivers with 150 W RMS Power @ 8 Ohms,IP65 (Make:- Tannoy/ Turbosound/ Apart Audio)
Supplying installation, testing, programming and commissioning of 2-Channel 1200 W power amplifier with Integrated DSP delivering500 W @ 2 Ohms,600 W @ 4 Ohms,300 W @ 8 Ohms,Networkedcontrol via IntelliDrive Controller™ touch-based GUI (Make:- Labgruppen/ Powersoft/ Crown)
Supplying installation, testing, programming and commissioning of Professional 8-Channel 3-Bus Mic/Line Zone Mixer with Remote Control and Link Ports (Make:- Behringer/ JBL/ Yamaha)
Supplying installation, testing, programming and commissioning of Gooseneck Microphone with Microphone Capsule and Base with on/Off Switch (Make:- AKG/ Sennheiser/ Audio Technica)
Supplying installation, testing, programming and commissioning of Wireless Vocal Microphone (Make:- AKG/ Sennheiser/ Audio Technica)
Supply and Laying of Audio Signal/ Microphone Cable (Make:- Gotham/ Klotz/ Belden)
Supply and Laying of Audio Speaker Cable (Make:- Gotham/ Klotz/ Belden/ Finolex)
Supply and Installation of Audio Connectors like XLR, RCA, Mono Jack etc (Make:- Amphenol/ Neutrik)
Supply and Installation of 17/18U Floor Mounted Equipment Rack with Castor Wheels (Make:- Nettrack/ Valrack/ Linkeu)
Supply and Installatoin of 6KVA Online UPS with SMF Batteries, Battery Rack and Interconnects (Make:- Numeric/ Delta/ APC)
Supplying installation, testing, programming and commissioning of 85" 4K Ultra HD HDR Professional Display. Backlight Type:- Direct (Full Array LED), Brightness (cd/m2) (*1):- 620 (Peak Brightness: 850 *1), Contrast Ratio (*1):- 4000:1, Viewing angle:- 178 X 178, Aspect Ratio:- 16:9, OS:- Android 9.0 Pie (Make:- Sony/ LG/ Panasonic)
Supplying installation, testing, programming and commissioning of 4K60 4:2:0 HDMI HDCP 2.2 Transmitter with RS–232 & IR over Long–Reach HDBaseT. INPUTS:- 1 HDMI on an HDMI connector, OUTPUTS:- 1 HDBT on an RJ–45 female connector, VIDEO:- Up to 10.2Gbps bandwidth (3.4Gbps per graphic channel), Up to 4K UHD @60Hz (4:2:0) 24bpp resolution Make:- Kramer/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of 4K60 4:2:0 HDMI HDCP 2.2 Receiver with RS–232 & IR over Long–Reach HDBaseT. INPUTS:- 1 HDBT on an RJ–45 female connector, OUTPUTS:- 1 HDMI on an HDMI connector, VIDEO:- Up to 10.2Gbps bandwidth (3.4Gbps per graphic channel), Up to 4K UHD @60Hz (4:2:0) 24bpp resolution, HDCP 2.2 signal compliance (Make:- Kramer/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of 4K HDR HDMI Audio De–embedder. AUDIO: Frequency Response: 20Hz to 20kHz @ +/–0.1dB S/N Ratio: >90dB, THD+N: 0.004%, VIDEO: Bandwidth: Up to 18Gbps (6Gbps per graphic channel), Max. Resolution: Up to 4K@60 (4:4:4), HDMI Support: 4K@60Hz and ARC as specified in HDMI 2.0, Content Protection: Supports HDCP 2.2 (Make:- Kramer/ Extron/ Atlona)
Supply and Installation of HDMI to HDMI Cable Length 10M (Make:- Kramer/ Extron/ Atlona)
Supply and Installation of HDMI to HDMI Cable Length 1M (Make:- Kramer/ Extron/ Atlona)
Supply and installation of Acoustic Panels 12mm: Performance: Sound Absorption coefficients 0.03- 0.8 (frequency 125 hz to 4000 hz), Material: Polyester Panel. Formaldehyde free, No odour, 100 % recyclable. The Acoustic panels to be fixed on 6MM Plywood which will be fixed on to surface of the Wall.
Supply and installation of FR grade 150mm wide 12mm thick Laminated plywood (150mm wide slat and 3mm gap between 150mm wide plywood) backed with 50mm thick 1000GSM polyester wool. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C .
Supply and installation of 600X 600 x15mm thk Grid Ceiling Area having density 15 mm (c. 4.5 kg/m2) , NRC upto 0.70, Reaction to fire, : A2-s1, d0 as per EN 13501-1, Sound attenuation: Dn,c,w = 34 dB as per EN 20140-9 (15 mm thickness, according to test certificate). Frame work shall consists of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm) fixed along with perimeter of the gypsum or walls with the help of nylon sleeves and screws at 600mm c/c. Then suspend GI main channels of size 45 mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1200mm c/c by using soffit angle of size 25mm x 10mm x 0.55mm thick fixed to true ceiling by using suitable fasteners. Cross channels of size 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the main channel with the help of connecting clips and in a direction perpendicular to the main channel at 300mm c/c .
Supply and installation of Acoustic Panels 12mm: Performance: Sound Absorption coefficients 0.03- 0.8 (frequency 125 hz to 4000 hz), Material: Polyester Panel. Formaldehyde free, No odour, 100 % recyclable. The Acoustic panels to be fixed on 6MM Plywood which will be fixed on to surface of the Wall.
Supply and installation of FR grade 150mm wide 12mm thick Laminated plywood (150mm wide slat and 3mm gap between 150mm wide plywood) backed with 50mm thick 1000GSM polyester wool. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C .
Supply and installation of 600X 600 x15mm thk Grid Ceiling Area having density 15 mm (c. 4.5 kg/m2) , NRC upto 0.70, Reaction to fire, : A2-s1, d0 as per EN 13501-1, Sound attenuation: Dn,c,w = 34 dB as per EN 20140-9 (15 mm thickness, according to test certificate). Frame work shall consists of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm) fixed along with perimeter of the gypsum or walls with the help of nylon sleeves and screws at 600mm c/c. Then suspend GI main channels of size 45 mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1200mm c/c by using soffit angle of size 25mm x 10mm x 0.55mm thick fixed to true ceiling by using suitable fasteners. Cross channels of size 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the main channel with the help of connecting clips and in a direction perpendicular to the main channel at 300mm c/c .
Supply and installation of Acoustic Panels 12mm: Performance: Sound Absorption coefficients 0.03- 0.8 (frequency 125 hz to 4000 hz), Material: Polyester Panel. Formaldehyde free, No odour, 100 % recyclable. The Acoustic panels to be fixed on 6MM Plywood which will be fixed on to surface of the Wall.
Supply and installation of FR grade 150mm wide 12mm thick Laminated plywood (150mm wide slat and 3mm gap between 150mm wide plywood) backed with 50mm thick 1000GSM polyester wool. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C .
Supply and installation of 600X 600 x15mm thk Grid Ceiling Area having density 15 mm (c. 4.5 kg/m2) , NRC upto 0.70, Reaction to fire, : A2-s1, d0 as per EN 13501-1, Sound attenuation: Dn,c,w = 34 dB as per EN 20140-9 (15 mm thickness, according to test certificate). Frame work shall consists of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm) fixed along with perimeter of the gypsum or walls with the help of nylon sleeves and screws at 600mm c/c. Then suspend GI main channels of size 45 mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1200mm c/c by using soffit angle of size 25mm x 10mm x 0.55mm thick fixed to true ceiling by using suitable fasteners. Cross channels of size 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the main channel with the help of connecting clips and in a direction perpendicular to the main channel at 300mm c/c .
Supply and installation of ceasefi re Portable Fire Extinguishers as per IS 15683 (2018)High Pressure Extinguisher (Service Pressure >19 bar) CarbonDioxide Based (as per IS 15222) Class -B ceasefi re (CF-000069)
Supply and installation ofFIRE SQUAD Portable Fire Extinguishers as per IS 15683 (2018)Low Pressure Extinguisher (Service Pressure ≤19 bar) PowderBased (as per IS 4308 ) Class -A FIRE SQUAD (FSP-GC-ABC9)
Supply and installation of SEAARA Portable Fire Extinguishers as per IS 15683 (2018) LowPressure Extinguisher (Service Pressure ≤19 bar) CarbonDioxide Based (as per IS 15222) Class -B SEAARA (RELIANCE)
Supply and installation PALEX Portable Fire Extinguishers as per IS 15683 (2018) LowPressure Extinguisher (Service Pressure ≤19 bar) PowderBased (as per IS 4308 ) Class -A PALEX (PSS-ABCFE-6)
M/S KENGE CONSTRUCTION CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid