Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.8 LAccepted-AOC | 1 | Accepted-AOC Awarded | |
| 2 | 2₹36.2 L+₹7.7 L (27.2%)Rejected-Finance | 2 | Rejected-Finance 2 lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Not qualified | |
| 4 | Rejected-Technical 00 RL QR NO 388 B KALIBARI COLONY ALIPURDUAR JN JALPAIGURI WEST BENGAL 736123 | ALIPURDUAR | WEST BENGAL | 736123 | - | Rejected-Technical Not qualified |
Tender Value
Refer Docs
EMD Value
₹30,500
Closing Date
26 Mar 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EWC,
3-Civil Lines, Bareilly
Increasing capacity of 33/11 KV Sub-Staions in district Budaun - Khitaura (2x5 to 2x10 MVA) and Mudiya (3x5 to 2x10plus5 MVA and Construction of 11 KV link line)
2021_MVVNL_572738_1
38/EWC(B)/2020-21
Open Tender
Electrical Works
Fixed-rate
90 days
Budaun
As per tender form
3 documents required · 3 mandatory
₹3,540
A/c No. 019205006347, IFSC Code ICIC0000192
₹30,500
10 Feb 2022
18 Mar 2021
27 Mar 2021
18 Mar 2021
26 Mar 2021
18 Mar 2021
180 days
Amount
Part (A)
Loading, unloading and safe carriage of the following materials from any Electy. Store Center of Electricity store division of Bareilly zone.
MS Channel 100x50mm @ 9.5 kg./mtr.
M.S.Angle 75x75x8mm @ 8.9 kg./mtr.
11 KV VCB I/C CTR 600/300/5A 250 MVA 630 A
11 KV VCB O/G CTR 200/100/5A 350 MVA
11 KV Cable 3x300 Sq. mm XLPE
11 KV Cables 3x185 Sq. mm XLPE
Earthing of indoor & outdoor equipments of Sub-Station after proper welding of joints and painting of earth strip above soil with proper clamp etc. as per RESPO approved drawing & resistance of earthing should be not more than 2Ω as per as per details given below.
Providing of bore well type pipe earthing 5mtr. below the water level but minimum depth of pipe earthing should be 40 mtr. at T/F neutral, LA. & equipment stuctures by using Ist class GI Pipe (ISI Mark)of size 40 mm dia.(All the required materials will be provided by firm.)
Making of triangular bridge for above pipe earthing by using 32 mm dia round bar & GI strip of size 50x6 mm. (All the required materials will be provided by firm.)
Supply of GI strip of size 50x6mm for earthing of all newly erected structures and equipments in switchyard including cutting, fixing & proper welding with equipments. All LA will be seprately earth also as per RESPO norms. (All the required materials will be provided by firm.)
Making of M.S. Angle Ladder type frame of Angle (75x75x8mm) & M.S. Strip (50x6mm) near power transformer for power cable with concreting of the same in the ground and proper clamping (50x6mm) of the same with transformer cable.
Making of M.S. Angle frame of (75x75x8mm) in L shape to connect T/F Neutral by flexible copper strip including cost of copper strip & will be connected to newly constructed well type earthing for Power T/F Neutral as per RESPO norms.
Laying of 11KV cable of different size from power T/F to control room I/C and control room to outside D/P. 11 KV Cable will be layed in brick trench constructed below 750mm to the ground level over the ganga sand. brick trench will be constructed by Ist class bricks covering three sides of cable, after laying 11 KV Cable brick trench will be filed by Ganga sand & then will be covered by bricks & backfill of soil over cable trench as per RESPO norms.
11 Kv cable hoisting with A class GI pipe of size 6" dia
Erection of 11 KV incoming and outgoing panels (with testing & setting of relays) in substation control room including grouting of Anchor bolts of panel and making of pocket for power cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Termination of 11 KV 3x300sqmm size XLPE cable by filling 11 KV heat shrinkable type cable boxes including proper connection with LV side of transformer, switch gear panels and double poles by providing suitable connectors.All the 11 KV cable boxes of different sizes make Raychem/Denson. (Cable box will be supplied by the contractor).
Termination of 11 KV 3x185sqmm size XLPE cable by filling 11 KV heat shrinkable type cable boxes including proper connection with LV side of transformer, switch gear panels and double poles by providing suitable connectors.All the 11 KV cable boxes of different sizes make Raychem/Denson. (Cable box will be supplied by the contractor).
Safe removal of existing old 5 mva 33/11 kv power transformer from plinth after disconnecting ht, lt, neutral earthing & wiring connections. draining out of transformer oil from transformer radiator and dismentalling of radiators. Proper placing & stacking of exisiting transformer to suitable place with in substation permises as per instruction of site incharge.
Safe carriage & commisioning (if required) of old & used 5 MVA transformer from site to other substation as per requirement :-
Safe loading & unloading of old & used 5 MVA Transformer with all accessories.
Rate for carriage (per km).
Placing the old & used 5 MVA transformer on the plinth, reassambling of transformer radiators, conservator & changing of all Gasket, testing after earthing of T/F neutral, HT/LT & wiring connection of old & used 5 MVA transformer
Centrifuging of transformer oil of old & used 5 MVA Transformer (if required).
Repairing of damage switchyard fencing.
Part (B)
Carriage of following line material for 11KV line from Store Centre to the site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site
STP 11Mtr. long
PCC Pole 8.5 Mtr. long
11 KV Cross Arm Channel V type
11 KV Pin insulator with pin
11 KV Disc insulator T&C type 45 KN. with its fitting
ACSR Raccon conductor
G.I. wire 6SWG/10 SWG
Stay set complete
Earthing complete
M.S angle lron 65x65x6mm
MS Channel 125x65x1300mm Tee off
M.S.Channel 100X50X2240mm @ 10Kg/Mt. for Top channel
Erection of the following supports after making of pits as per RESSPO norms & filling of pits by concrete of ratio 1:4:8 (cement brick balast & sand). Fitting of all accessories as cross arm, top channel, bracing angle, pin insulator, disc insulator, danger board, number plate, barbed wire & clamps etc. Plinthing of support above 300mm ground level by concrete of ratio 1:4:8 (cement brick balast & sand) will be done at the time of erection of pole. Painting of ST Pole structure as per RESSPO norms also (all type of paints, red oxide primer, nut, bolts & grouting material etc. will be provided by contractor).
Single support of S.T pole 11 mtr long.
Single support of PCC pole 8.5 mtr long.
Double pole structure on PCC Pole 8.5mtr long complete with bracing.
Double pole structure on S.T. Pole 11mtr long complete with bracing.
Erection of stay set with stay wire, stay clamp & stay insulator including with grouting of stay set by concrete of ratio 1:4:8 as per RESSPO norms before back fitting of the pits including binding, climbing, clamping, tightening and nozzeling of stay wire in all respect as per RESSPO norms. All clamps, nuts, bolts, stay insulator, cement. brick, ballast, sand etc would be provided by the contractor.
Laying and sagging of 3 phase ACSR Raccon conductor from double pole at 33/11 KV substation to double pole at tapping point of 11 KV feeder line including jumpering, hoisting, fixing of all type of insulators, binding, jointing and its clamping etc in all respect.
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering upto 0.5 mtr, below ground leven and properly fastning with GI wire to each support by lug, nut & bolt as per RESSPO norms. All type nut & bolt would be given by the contractor.
Earthing of each PCC Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support & its accessories by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Guarding of HT/LT/Telephone Line/ Road/River Crossing etc. by providing G.S Earth wire 7/16 SWG/GI wire No. 8/10 and making net with difference of 1.00 Mtr. Completely including fixing of channel/angle etc. with proper locking at each support as per RESSPO norms. All type nut &bolts, would be given by the contractor.
Supply of following line items as per RESSPO drawing & dimensions:-
Danger plate (size 250x200x2mm) with clamp, nut & bolts
Number plate (size 250x200x2mm) with clamp, nut & bolts
Barbed wire
Clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of site incharge.
M/S SUPER ENGINEERING TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .