Loading…
Loading…
Tender Value
₹12.2 Cr
EMD Value
₹24.5 L
Closing Date
7 Oct 2026, 11:00 am
Regional Officer, NHAI Regional Office, Madurai
NHAI Regional Office, Madurai
Implementation of Road Safety Measures and ATMS, Operation and Maintenance of ATMS and Other Safety Improvements on Nagercoil - Kavalkinaru Section of NH-944 in Tamil Nadu on Item Rate Basis
2026_NHAI_291008_1
NHAI/17011/01/158/2026/RO Madurai
Open Tender
Civil Works - Highways
Item Rate
180 days
Nagercoil-Kavalkinaru
Please refer Tender Documents
2 documents required · 2 mandatory
₹50,000
NHAI
₹24.5 L
16 Sept 2026
16 Sept 2026
8 Oct 2026
16 Sept 2026
7 Oct 2026
16 Sept 2026
Type - A, "W" : Metal Beam Crash Barrier Providing and erecting Single sided Single Guard Metal Beam Crash Barrier System (Type A, "W" Single Guard)1.80m high, comprising of 3mm thick wall "W" beams posts and spacer channels shall be made by cold roll forming using HR conform to IS 5986 Fe 410/360 and dip galvanized having Zinc Mass of 550gms/sqm, minimum 700 mm above road/ground level fixed on ISMC series channel vertical post 150x75x5mm spaced 2m center to center 312mm x 83mm flange width x 3mm thick, 4318mm long post directly embedded in the concrete (M15) pit size 350x350x800mm for a depth of 1100mm below ground. All fixing bolts and nuts hot dip galvanized conforming to IS: 1367 clause 4.60 all complete as per Technical Specification of IRC 119 2015 and as directed by the Engineer-in-charge.
Crash barrier for protection of overhead sign post/ hazard
Ch.0.500 RHS, Ch.0.800(M-LHS), Ch.0.800(M-RHS), Ch.1.600(M-LHS), 1.600(M-RHS), Ch.3.100(M-LHS), Ch.3.100(M-RHS), Ch. 3.600(M-LHS), Ch. 3.600(M-RHS), Ch. 4.100 (M-LHS), Ch. 4.100 (M-RHS)
Crash barrier for Gantry Sign & closing median at Ch 1.2
Ch. 15.900(M-LHS & M-RHS) ( Two gantry in 30 m interval)
Crash Barrier for median closure Ch14.9 to Ch14.85 (Both Side of median) With MELT & TT
Crash Barrier with appropriate end terminal requirement- At approach & departure side of parapet wall, high embankment, separation of Main road & service road, etc.
Ch. 4.450 Extend MBCB for 80m to gore an attach to attenuator
Ch. 8.05 LHS extend MBCB by 120 m to gore and Provide MELT terminal
Ch.8.6 RHS extend MBCB by 120 m to gore and Provide MELT terminal
Ch. 4.030 LHS, High Emb, 3+900 to 4.134 LHS
Ch. 4.900 RHS, Extend MBCB to Gore
Provide W Beam Crash barrier (about 33m)on approach side and 17m on departure side on both LHS & RHS with appropriate end terminals. Further, fasten the W Beam to the concrete crash barrier. Refer Figure 9.14 and Figure 9.9 of IRC SP-84:2019 for details of transition from normal W Beam section to rigid barrier and terminal connection details, respectively.
i) Both LHS & RHS (Approach 33m & Departure 17m)
ii) Only LHS or RHS (Approach 33m & Departure 17m)
iii) Only Approach(33m)
iv) Only Departure (17m)
Damaged Barrier Replacement
ch.0+300, Ch. 1.180, Ch. 5.35 (LHS) Ch.7.600, Ch. 12.380, etc.
Close gap in MBCB- Ch 12.5 (LHS & RHS)
Connection of MBCB with Concrete barrier
Reinstallation of W-beam, the panels shall be overlapped in the direction of traffic as per IRC SP 84-2019
CH. 0.24 to Ch. 0.53
CH. 5.35 to Ch.6.05 ( 2 wrong overlap panels)
Ch 7.56 LHS (12 no. of panels)
Ch 7.65 LHS (16 no. of panels)
Ch. 7.8 RHS (5 Nos. of Panels)
Ch. 8.3 (16no. Of panels)
Ch 11.7 (18 no. of wrong overlap)
Ch. 14.65 (25 nos.)
MELT End treatment on Approach Side- Turn down/ untreated end of MBCB to be treated both approach & departure side as per IRC SP 84-2019
Turn down end terminal to be replaced by MELT Type End Terminal -
MELT for MBCB provided for Column/hazard Protection
MELT for MBCB provided for Parapet Protection
TT End treatment on Approach Side- Turn down/ untreated end of MBCB to be treated both approach & departure side as per IRC SP 84-2019
Turned down end terminal to be replaced by TT Type End Terminal-
TT for MBCB provided for Column/ hazard Protection
TT for MBCB provided for Parapet Protection
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
PCC M20 for Kerb (Cast in Situ)
Providing and Fixing of Retro- Reflectorised Hazard Marker Traffic Sign made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC- 67:2012 and ASTM D 4956- 09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mmX25mmX3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear 0.6mm below ground level. The signpost should be painted as per IRC 67- 2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading chargers necessary for satisfactory completion of the work as directed by the engineer in charge. High intensity Retro- Reflector sheet shall consist of minimum coefficient of Retro- reflection as per Table 6.6 of IRC 67- 2012. The retro- reflective sheeting shall be covered under 7-year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2012. (as per MORT&H Specification No.801) 30cm x 90cm rectangular
Hazard marker in front of MBCB provided for column/ hazard protection
Hazard marker in front of MBCB provided for Parapet wall
In front of MELT terminal
Two-way hazard marker -0.4(RHS), 16.05(LHS), 13.2 (channelizing island)
Retro- reflectorised Traffic signs - Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per clause 801 of MoRTH Specifications for Roads & Bridge Works and IRC: 67 (2022) made of class -C Micro Prismatic Grade Sheeting of Type XI retro reflective sheeting. The retro reflective sheeting shall have manufacturer logo, watermark and lot number on the sheet. A QR (Bar) code shall also be placed on the backside of the sign board with an indelible ink. For signs above 600mm size, retro reflective sheet shall be fixed over 2 mm thick aluminium sheeting vide or 4mm thick Aluminium composite material sheet vide clause 801 of MORTH Specifications for Roads & Bridge Works. For signs above 600mm sizes, sign shall be fixed over back support frame of minimum 35 x 35x 3 mm angle Frame. For signs above 600mm size, Signs shall be supported on GI circular pipe 80 NB, 3.2 mm thickness confirming to IS 1239. Retro-Reflective sheet shall be fixed on Substrate with Pressure Sensitive Adhesive. The Substrate shall be firmly riveted on Angle Frame @ 200mm spacing with Aluminium Pop rivets using Pneumatic Guns. The Angle frame shall be firmly fixed with high strength bolts, washers nuts conforming to IS1364 and IS 1367 on Sign Support Pole. Sign Supports shall be firmly fixed to the ground by means of properly designed foundation with M 25 grade cement concrete 45 cm x 45 cm x 60, 60 cm below ground level as per approved drawing. All Components of signs and supports including Angle Frame, Bolts, Nuts, Washers, etc. other than the reflective portion shall be galvanized by hot dip process (Zinc coated, 0.55 kg/sqm; minimum single spot) unless otherwise specified. All galvanizing shall be done after fabrication. Alternate white and yellow bands measuring 50 mm long retro-reflective sheeting shall be pasted around Gl posts which help in ensuring the visibility/Presence of poles during night time even if the sign boards are stolen or totally vandalized. Minimum four bands of such retro-reflective sheeting shall be pasted starting from a height of 0.5 m above the finish road level. The messages (legends, letters, numerals, etc.) and borders as per clause 6.8 of IRC 67 shall be digitally printed. Finished Signs shall have an Ultra Violet (UV) protective clear overlay applied to the entire face of the signs supplied by reflective sheet manufacturer. The agency shall submit 10 years warranty for satisfactory field performance for type XI retro reflective sheeting from the retro-reflective sheet manufacturer confirming to clause 6.7 & 6.9 of IRC 67. Agency shall submit a certified copy of test reports from an Government laboratory/ Institute conforming to clause 6.7 & 6.9 of IRC 67 including 3 years accelerated outdoor weathering for the retro reflective sheeting. The Agency shall submit the sign convertor (manufacturer) name with details of essential equipment available with convertor in his fabrication shop such as digital printer, cutter, plotter, laminator, Galvanizing plant, etc. The Agency shall submit road sign installation drawing in 'Kmz' file for approval before installation and after installation submit geo-tagging of all road signs with its installation photos and date of installation and other details as mentioned in IRC 67 annexure VII, complete in all respects. The sign supports and its foundation details are indicative. These may be increased for areas having higher wind velocities like in coastal areas. This is applicable to all road signs and directions boards.
120 cm circular
Restriction End Sign (km 0.500,3.400,10.500,16.276)
Keep left sign (km 3.420,10.500,12.200,13.200)
Speed limit (mcw km.1.050 lhs,3.780 rhs,4.350 rhs, 5.950 lhs,9.350 rhs,11.350 lhs,
120cm Warning Sign/ Triangular Sign CH 0.75 & Ch 3.2
90cm Warning Sign/ Triangular Sign Ch0(Slip road)., Ch 0.75, Ch. 1.2 (Speed Breaker & Junction warning on Side Road)
90 cm Octagonal Sign
Chevron Sign Board (size of 60cm x 50cm) Km.7+000,15.800
Providing and fixing of retro-reflectorised direction and place identification sign as per {clause 801 of MoRTH Specifications for Roads & Bridge Works (5th Revision) and IRC : 67 made of class -C Micro Prismatic Grade Sheeting of [Type XI retro reflective sheeting. The retro - reflective sheeting shall have manufacturer logo, watermark and lot number on the sheet. A QR (Bar) code shall also be placed on the backside of the sign board with an indelible ink. Retro reflective sheet shall be fixed over 2 mm thick aluminium sheeting or 4mm thick (Aluminium composite material sheet vide clause 801 of MORTH Specifications for Roads & Bridge Works. The sign shall be fixed over back support frame of minimum 40x40x 5mm Angle Frame. Retro-reflective sheet shall be fixed on substrate with Pressure Adhesive. The substrate shall be firmly riveted on angle frame @200mm spacing with aluminium pop rivets using Pneumatic guns. The Angle frame shall be firmly fixed with high strength Bolts, washers & nuts conforming to IS1364 and IS 1367 on Sign Support Pole. Signs shall be supported on two or more Gl circular pipe 80 NB, 3.2 mm thickness confirming to IS 1239. Adequate bracing shall be provided to hold firmly GI support pipes. The sign supports shall be firmly fixed to the ground by means of properly signed foundation with M 25 grade cement concrete 45 cm x 45 cm x 60, 60 cm below ground level as per approved drawing. All components of signs and supports including single frame, bolts, nuts, washers, etc., other than the reflective portion shall be galvanized by hot dip process (Zinc coated, 0.55 kg/sqm; minimum single spot) unless otherwise specified. All galvanizing shall be done after fabrication. Alternate white and yellow bands measuring 50 mm long retro-reflective sheeting shall be pasted around GI posts which help in ensuring the visibility/ Presence of poles during night time even if the sign boards are stolen or totally vandalized. Minimum four bands of such retro-reflective sheeting shall be pasted starting from a height of 0.5 m above the finish road level. The messages (legends, letters, numerals, etc.) and borders shall be digitally printed confirming to clause 6.8 of IRC 67. finished Signs shall have an Ultra Violet (UV) protective clear overlay applied to the entire face of the signs supplied by reflective sheet manufacturer. The agency shall submit 10 years warranty for satisfactory field performance for type XI retro reflective sheeting from the manufacturer conforming to clause 6.7 & 6.9 of IRC 67. Agency shall submit a certified copy of test reports from Government laboratory/ Institute conforming to clause 6.7 & -9 of IRC 67 including 3 years accelerated outdoor weathering for the retro reflective seeting. The Agency shall submit the sign convertor (manufacturer) name with essential equipment in his fabrication shop such as digital printer, cutter, plotter, laminator, Galvanizing plant etc. The Agency shall submit road sign installation drawing in 'Kmz' file for approval before installation and after installation submit geo-tagging of all road signs with its installation photos and date of installation and other details as mentioned in IRC 67 annexure VII, complete in all respects. The sign supports and its foundation details are indicative. These may be increased for areas having higher wind velocities like in coastal areas. This is applicable to all road signs and directions boards.
Providing and fixing of retro-reflectorised stickers as per clause 801 of MoRTH Specifications for Roads & Bridge Works and IRC: 67 (2022) made of class -C Micro Prismatic Grade Sheeting of Type XI retro reflective sheeting. The sticker shall have NHAI Los Logo digitally printed with colour specification confirming to Sl no. 5.2 of NHAI Policy Circular 4.37/2025 dated 11th Nov 2025. Finished Signs shall have an Ultra Violet (UV) protective clear overlay applied to the entire face of the sticker supplied by reflective sheet manufacturer. Retro-Reflective sticker shall be fixed on alternate barrier posts with pressure sensitive adhesive. Sticker fixing shall be done after wiping the surface with a clean cloth soaked in isopropyl alcohol (IPA) or mild detergent, Remove all dust/ oil / grease/rust and moisture and allow surface to dry completely. If required use a heat gun or blower to dry surface if ambient humidity is high. Fix sticker on the prepared surface by removing the sticker liner slowly to avoid curling or contamination, preposition the sticker to ensure correct orientation and alignment, fix the sticker gently, use a felt-edge squeegee hammer or roller to apply uniform pressure from centre to outward, ensure no air bubbles or wrinkles remain, apply pressure across the entire surface to fix sticker firmly. The agency shall submit 10 years warranty for satisfactory field performance for type XI retro reflective sheeting from the retroreflective sheet manufacturer confirming to clause 6.7 & 6.9 of IRC 67. Agency shall submit a certified copy of test reports from a Government laboratory/Institute conforming to clause 6.7 & 6.9 of IRC 67 including 3 years accelerated outdoor weathering for the retro reflective sheeting. The Agency shall submit the sign convertor (manufacturer) name with details of essential equipment available with convertor in his fabrication shop such as digital printer, cutter, plotter, laminator, etc.
Providing and Fixing of Flexible Median Marker that are made of tough, high impact resistant, injection-molded, thermoplastic body with property of flexibility to provide high durability. The dimension of Flexible Median Marker should not exceed 18.4 cm in height (including shank height), 12.5 cm in width, 0.65 cm in thickness and shank depth shall be 3.4 cm. The body structure shall be rounded at all its corners and edges. The plastic used for molding the Flexible Median Marker should survive impact load of 5 kg continuously for 750 times at room temperature. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The Median Marker shall have flame-like shaped body with fluorescent yellow color retro-reflective sheeting of size not less than 90 cm square, with fully reflective micro prismatic cube corners as its retro-reflective elements as per IRC 67 2012 and ASTM D4956-09 type XI specifications reflectivity values. The retro-reflective sheeting shall be one or both sides of the Flexible Median Marker and shall be edge protected with no exposed edges which will prevent edge lifting, vandalism, sheeting damage, etc. The Flexible Median Marker shall be fixed by a combination of epoxy adhesive and grouting as recommended by the manufacturer.
Solar Blinkers: Supplying and erecting red /yellow unbreakable polycarbonate body Solar Blinker 300mm dia. LED lamp confirming to IRC:93 and IS:7537. It shall have Light Emitting Diode (LED) - Hi Bright technology (Compliant to EN12368 or equivalent BIS standard). The Signal Switching shall be Solid State, with Opto-isolation. The Automatic operation mode shall have functional flashing rate available at 50% Duty Cycle 50 ог 60 Flashes/minutes. The Electrical Power Supply shall be solar based 12 VDC operating at Ambient temperature 0° to 55°C. The solar power system shall have in-built charge Controller - Low/High cut out, Solar SPV Module 60 Watts, Maintenance Free Battery (60AH) (having back up for operating blinker for 72 Hrs in absence of Sun or during rainy or foggy days. The Solar System shall be housed in a weatherproof pole mounting cabinet with clamp and mounting accessories. The Solar Blinker shall be supported on Gl circular pipe 80 NB, 3.2 mm thickness confirming to IS 1239, 3m above the Finish Road level. Gl circular pipe shall be firmly fixed to the ground by means of properly designed foundation with M 25 grade cement concrete 45 cm x 45 cm x 60, 60 cm below ground level as per approved drawing. Alternate white and yellow bands (Minimum four bands) of Type XI retro-reflective sheeting shall be pasted @ 0.5m c/c starting from a height of 0.5 m above the finish road level.
Supply and Installation of Creative Display sign Creatives display at the fascia below NH structures As per the guidelines Policy Cricular No.4.35/2025 dated.07.02.2025, by Providing and fixing of high quality Retro-reflective reboundable Sheeting as per IRC 67-2022 . The reflective sheeting to be either applied on Aluminium Composite panel of 3mm thick having aluminum film thickness of not less than 0.25mm or can be directly applied on the structure after surface preparation. The adhesive of the film should be a pressure activated adhesive providing repositionability and has non-visible air release channels to provide a bubble free application. The sheeting should be printed using a sheeting manufacturer authorized printing platform, applied with a suitable overlaminate film for protection and then installed. The MCS warranty should be provided by sheeting manufacturer on the performance of retro-reflectivity and colour fade. Printing on face material must be done with Latex Wide Format Digital Printer with GREENGUARD / GREENGUARD GOLD Certified Inks only. Ink Layer should not peel, crack from base substrate used in the intended print application. The entire print construction must be protected with compatible high-quality UV Resistant Overlaminate film as per manufacturers recommendations. Use of over-laminate is mandatory to protect the print from fading with high conformability to take shape of textured surface of wall. The thickness of the over lamination film should be min 0.05 mm without adhesive. Overlaminate should have good chemical resistance property and should resists mild alkalis, mild acids, and salt. It should show excellent resistance to water (does not include immersion) and should resists occasional fuel spills. Incase of retro-reflective sheeting, a test report passing all the parameters including 36months Outdoor as per IRC 67-2022 clause 6.7 to be submitted. The contractor shall submit A4 size sample of the Type I rebound able sheeting with digital printing as per IRC 67-2022 MCS Warranty conditions. The cost to include all the activities like surface preparation, any cladding / Scaffolding need etc as per site requirements and OEM recommendations with full safety protocol on the Deck Slab/ Crash Barrier at NH66 and NH944.
Putheri Bridge Lighting @79+642 BOW String Major Bridge
Supply Installation Testing and commissiong of top bend neox flex LED, 14-16W/M, RGBW, IP 67, DC24V ,External common power supply with Inbuilt DMX Decoder Neon Flex. The Neon Flex should be pixel controlled with minimum 8 pixels per meter for precise control.- Silicon material-Much more flexible,Efficient heat dissipation,Smooth plane lighting surface,Perfect resealing with silicone glue. Resistant UV, Flame, Salt, Chlorine. with suitable aluminium fixing clips(3nos./M) for mounting. DC 24V, Efficacy>25lm/W. SMD LED. Neon Flex should includes Inbuilt DMX 512 Decoder, DC 24V Electronic Power Supply-metal body(Inventronics/Meanwell) ,which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection. Sample Should be submitted for concerned engineer incharge for approval of light fixture. Approved Make : Lumenpulse/Philips/Erco/Zumtobel
Supply Installation Testing and commissiong of Circular shaped architectural LED flood light with integral driver & housing made of extruded Aluminium with Die-cast aluminium end caps. Product dimension of luminaire: Dia : 135mm and Height: 141mm (with bracket). The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 & IK06 protection. The nominal weight of the luminaire shall not be more than 1.8Kg. The luminaire shall be equipped with high-power Cree, Osram, Lumiled or equivalent. The fixture shall have 10° beam angle (±10%), CCT-RGBWW & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 24W and system lumen output of not less than 1090 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables. Approved Make : Lumenpulse/Philips/Erco/Zumtobel
Supply Installation Testing and commissiong of Circular shaped architectural LED flood light with integral driver & housing made of extruded Aluminium with Die-cast aluminium end caps. Product dimension of luminaire: Dia : 170mm and Height: 164mm (with bracket). The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 & IK06 protection. The nominal weight of the luminaire shall not be more than 3Kg. The luminaire shall be equipped with high-power Cree, Osram, Lumiled or equivalent. The fixture shall have 10° beam angle (±10%), CCT-RGBWW & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 40W and system lumen output of not less than 1580 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables. Approved Make : Lumenpulse/Philips/Erco/Zumtobel
Supply Installation Testing and commissiong of Circular shaped architectural LED flood light with integral driver & housing made of extruded Aluminium with Die-cast aluminium end caps. Product dimension of luminaire: Dia : 170mm and Height: 164mm (with bracket). The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 & IK06 protection. The nominal weight of the luminaire shall not be more than 3Kg. The luminaire shall be equipped with high-power Cree, Osram, Lumiled or equivalent. The fixture shall have 10° beam angle (±10%), CCT-RGBWW & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 50W and system lumen output of not less than 2140 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables. Approved Make : Lumenpulse/Philips/Erco/Zumtobel
Supply Installation Testing and commissiong of outdoor IP66 rated 24V/ 300W driver or SMPS to provide the supply to the above LED linear light. Approved Make: Meanwell/Philips/Inventronics driver
Supply Installation Testing and commissiong of 10 pieces of 5 pole 2mtr factory made female connector cable to connect the DMX enabled light fixture with the controller data line for better connectivity. Approved Make : Lumenpulse/Philips/Erco/Zumtobel
Supply Installation Testing and commissiong of 10 pieces of 5 pole 2mtr factory made female and male connector cable to connect the DMX enabled light fixture with the controller data line for better connectivity. Approved Make : Lumenpulse/Philips/Erco/Zumtobel
Supply Installation Testing and commissiong of 20 pieces of factory made male/ female endcap to terminate the data network. Approved Make : Lumenpulse/Philips/Erco/Zumtobel
Supply Installation Testing and commissiong of compact DMX signal splitter cum amplifier that takes the incoming DMX512/RDM signal and amplify the signal and supporting bi-directional communications for discovery, addressing and DMX control of light fixtures.This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Operating temperature shall be -10° to 35°C. The maximum power consumption shall be less than 4.5W and input voltage shall be 12-24V DC. Approved Make : Lumenpulse/Philips/Erco/Zumtobel
Supply Installation Testing and commissiong of Main controller DMX - Main Controller: Industrial grade controller that can control the sub controllers of up to 6000 DMX universes. Wiring accessories include leader and jumper cables with male and female IP67 connectors and end-caps. Connected in Stand Alone mode, receiving power from an adapter. Compatible with Windows 10 32-bit or 64-bit version or equivalent. Complies with standard DMX control protocol. Amplifier or Repeater is used here for to extend the installation without limits is also called ‘Booster’ or repeater. They work on their own power supplies (drivers) work with 12 or 24V drivers. The controller shall have stable signal transmission and can synchronize with NTP and GPS. The controller shall support power on start-up and scheduled time-start, automatic scenes play-back and scheduling, supports upgrading devices firmware over the network. It shall have two RJ45 network interfaces (100/1000M adaptive). The housing shall be of steel, Aluminium with black finish weighing approx. 11.6kg. It shall work at a temperature range of 0deg C to 40 deg C and input voltage range of 100-240V AC/50-60 Hz, Humidity range 10 to 85% (no condensation). Approved Make : Lumenpulse/Philips/Erco/Zumtobel.
Sub-controller 12V 8 port DMX - Sub - Controller: Fits for medium applications, and it is based on TCP/IP Protocol. The sub-controller structure is based on an industrial grade ARM and ultra-large-scale programmable logic circuits. Wiring accessories include leader and jumper cables with male and female IP67 connectors and endcaps. Connected in Stand Alone mode, receiving power from an adapter. The sub controller shall support online firmware upgrade, Art-net, daisy chain, brightness control for easy white balance adjustment. It shall also support automatic luminaire addressing and supports from Compatible with Windows Ten 32-bit or 64-bit version or equivalent. Complies with standard DMX control protocol. They work on their own power supplies (drivers) work with 12 or 24V drivers. The housing shall be of Aluminium with black finish weighing approx. 11.6kg. It shall work at a temperature range of -30deg C to 50 deg C and Humidity range 10 to 90% (no condensation). Amplifier or Repeater is used here for to extend the installation without limits is also called ‘Booster’ or repeater. Approved Make : Lumenpulse/Philips/Erco/Zumtobel.
Supply Installation Testing and commissiong of address writing and testing tool for DMX512 luminaires, made of Extruded aluminum. The device supports internal test animation for DMX512 addresses verification. The device can automatically write address to a whole group of interconnecting luminaires within minutes. The Addresing kit must be capable of powering from a Micro-B type USB port for on-site programming and testing.The input voltage range is 6-24V DC, IP20 Protected. (ZXP399 ADDRESSING KIT DMX).The addressing kit and controller shall be of same oem make for compatibility. Approved Make : Lumenpulse/Philips/Erco/Zumtobel.
Designing, Addressing, Installation, Testing, Commissioning & Programming (Lighting)
Elimination of Hotspots with 8 mtr Solar High mast lighting with suitable Foundation at NH47B
Supply and installation of Double arm solar street lights- Supply of 2x 80w (+/-5w) stand alone Solar Streetlight system having 2 days backup and suitable for dimming
streetlight luminaire shall have minimum 12,500 Lumens System output, greater than 160 Lumens per watt system efficiency, IP66 & IK10 Protection, luminaire made corrosion proof coated pressure diecast aluminium housing and individual lens for each LED embedded on PC Cover >70,000 burning hours life- 2no.
Solar Panel of 300 - 340 Wp Mono-crystalline 36V with excellent aging resistance and UV endurance to withstand harsh environment environmentally sealed to IP67-2nos
The batteries using in the system shall be of 25.6V 60Ah,1536Whr maintenance free lithium pherro phosphate battery having minimum 2000 cycles life- 2nos
The Charger controller using in the system shall be 400Wp MPPT type Programmable and dimmable via bluetooth app at site-2 nos
Foundation- the tenderer shall design necessary foundation based on required soil bearing capacity. The bidder shall be responsible for the design of foundation and safe erection/installation of high mast. Anchor bolts shall be made of high tensile steel grade EN 8 as per IS 2062:2011, Gr E250 A. Suitable anchor plate shall be provided for holding down the bolts in position.
Supply, Installation, Testing & Commissioning of Advanced Traffic Management System (ATMS), Operation & Maintenance of ATMS as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023 and the Standard ATMS Document, 2023, as amended from time to time.
Traffic Monitoring Camera System Equipment (TMCS) as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
PTZ Surveillance Camera (36x zoom) with 100m IR as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Local Processing Unit as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Incident Detection License for TMCS as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
12 Mtrs Octagonal Pole - Civil work as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Road side Unit as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Solar Power System with 6 Hrs backup as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Interface Card as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Earthing as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Lightning Protection as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Chamber as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Video Incident Detection and Enforcement System (VIDES) as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
VIDES Fixed Over View Camera for each direction as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
ANPR Camera as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
ANPR License as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Traffic Violation Detection Module (Seat Belt, Triple Riding, No Helmet) License as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
ATCC Module as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Local Processing Unit (LPU) -Incl. Internet connectivity as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Speed Detection Radar as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Gantry - Inverted "U" shape - Incl. Civil work as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Flashing light powered by local Solar backup - Incl. Civil work as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Road side Unit for VIDES as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Solar Power System with 6 Hrs backup as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Interface card as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Earthing as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Lightning Protection as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Chamber as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Vehicle Actuated Radar Speed Display (VARSD) - At every 20 Km covering LHS and RHS. as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Display as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Data logging camera as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Radar as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
LPU as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Inverted "U" Shape Gantry - Incl. Civil work as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Road side Unit as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Solar Power System with 6 Hrs backup as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Interface card as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Earthing as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Lightning Protection as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Chamber as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Variable Message Sign Equipment (VMS M-Type) as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Full Fixed VMS (5000m x 1800mm) as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Gantry -Inverted "U" Shaped - Incl. Civil work as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
5 KVA UPS with 6 hrs Backup as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Road side Unit as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Interface card as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Portable VMS (1650mm x 1000mm) including trolley & anchoring mechanism as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Earthing as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Lightning Protection as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Chamber as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
OFC based Communication - As per ATMS specification document clause 1.2.6 as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
OFC 24 Core Single Mode Armored as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
OFC 12 Core Single Mode Armored as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
HDPE PLB Duct (Size 40/33 mm) as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Laying of HDPE duct(trenching where median is available), OFC blowing and splicing as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Joint Enclosure as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
LIU as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
LIU at Control Room as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Patch Cord as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
SFP 20 Km as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Control Room Equipment as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Video Recording Server as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Backup Video Recording (Only Incident) Server (In hot stand-by) as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Windows Server 2022 Standard Edition as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Windows SQL Server 2022 Standard Edition as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Network Switch for Control Room as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
ATMS (Central Command & Control Software) as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
VAMS Software with Analytics (Video Analytics Management System) as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Antivirus as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Optical Fiber Switch as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Project Management as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Project Management - Design Documentation, Installation, and Commissioning of the ATMS Equipment - as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Installation, Cabling, Networking & Commissioning of the ATMS Equipment's - as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Manpower Services During 5 Year of DLP as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Deployment of 1 no. of on-site Resident Engineer who will be available for 8 hours a day/6 day a week for 1st year DLP post CoD - as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Deployment of 1 no. of on-site Resident Engineer who will be available for 8 hours a day/6 day a week for 2nd year DLP - as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Deployment of 1 no. of on-site Resident Engineer who will be available for 8 hours a day/6 day a week for 3rd year DLP - as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Deployment of 1 no. of on-site Resident Engineer who will be available for 8 hours a day/6 day a week for 4th year DLP - as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Deployment of 1 no. of on-site Resident Engineer who will be available for 8 hours a day/6 day a week for 5th year DLP - as per NHAI Policy Circular No. 11.53/2023 dated 10.10.2023
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
RFP.pdf
Tender Documents • 23.32 MB
Price bid - Final.xlsx
Additional Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .