Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical PROPERTY NO 228 FIRST FLOOR SECTOR 19 DYCON SYSTEMS PVT LTD AMBERHAI ROAD NO 2 SECTOR 19 DWARKA SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | Rejected-Technical Not Qulaified |
Tender Value
₹3.8 L
EMD Value
₹7,560
Closing Date
24 Nov 2022, 6:00 pmClosed
EXECUTIVE ENGINEER SEWER PROJECT HERITAGE
JAIPUR NAGAR NIGAM HERITAGE, OLD POLICE HEADQUARTER BUILDING, JALEB CHOWK, BADI CHOPAR JAIPUR
Supply, Installation, testing and commissioning of online continuous effluent flow monitoring system (OCEMS) and flow meter at outlet chamber in Brahmpuri 8 MLD STP Jaipur including 2 year O and M after Warranty period
2022_DLB_305451_1
04 EXECUTIVE ENGINEER SEWER PROJECT HERITAGE
Open Tender
Miscellaneous Works
Item Rate
30 days
JAIPUR
As Per Bid Documents
3 documents required · 3 mandatory
₹1,000
ONLINE PAY IN JAIPURMC HERITAGE WEBSITE
₹7,560
Yes
29 Nov 2022
15 Nov 2022
25 Nov 2022
15 Nov 2022
24 Nov 2022
15 Nov 2022
Amount
Supply, Installation Testing Commissioning Operation of date module for online continuous effluent monitoring system (OCEMS) PTZ camera along with technical expert and calibration test of equipment including following activities as per CPCB/RSPCB guidelines. 1. Providing CPCB/ RPCB approved control for Channel output. 2. Including installation of data module for COD, BOD, pH and TSS parameters & flow along with Data transfer of above units. 3. Including internet connectivity, ups, cables, electricity fitting with required backup system plumbing fittings, loading and unloading complete as contained in scope of work in the notice Inviting tender. Flow by signal/multiple analyzer with various sensors (Dual Beam spectral scanning in the UV-VIS range) performing reagent and chemical free analysis with automatic built in cleaning provision of all sensors, signal cables and power cables, local data acquisition and display of data on continuous basis for up linking the data to CPCB, RPCB with intermediate logic/server/web Based application. The system should be maintains since installation
Supply, Installation Testing Commissioning Operation of Ultrasonic open channel flow meter along with effluent flow data transfer to CPCB/RSPCB web site including all necessary arrangements as per site requirements and as per directions of engineer in charge
Description of Work / Item(s)
Amount
Annual Maintenance Contract after warranty 2nd year AMC AMC for Water Quality Monitor (BOD, COD, TSS PH & Flow meter) for outlet 1- Four service visit in year will be schedule 2- Calibration two times in a year 3- Data transfer to CPCB & SPCB 4- Consumable.
3rd Year AMC AMC for Water Quality Monitor (BOD, COD, TSS PH & Flow meter) for outlet 1- Four service visit in year will be schedule 2- Calibration two times in a year 3- Data transfer to CPCB & SPCB 4- Consumable
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .