Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.8 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹28.8 L+₹1.9 L (7.25%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹28.8 L+₹2.0 L (7.47%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹31.9 L+₹5.1 L (18.8%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹34.3 L+₹7.5 L (27.9%)Rejected-Finance BOOTH NO 119 SECTOR 9 PANCHKULA 134109 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134109 | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
26 Nov 2022, 6:00 pmClosed
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIR MAINT OF DG SET SECURITY LIGHTS FLOOD LIGHTS TIMER SWITCH SECURITY LIGHTS CABLES AND CONNECTED WORKS AT NEW CANTT UNDER GE(NORTH) PATIALA
2022_MES_551881_2
GE(N)/PAT-48/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹90,000
Yes
23 Dec 2022
5 Nov 2022
28 Nov 2022
5 Nov 2022
26 Nov 2022
12 Nov 2022
Amount
Supply and fixing in replacement of Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 45 watt, complete all as specified and as directed.
Supply and fixing in replacement of Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 60 watt, complete all as specified and as directed.
Supply and fixing in replacement of Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 120 watt, complete all as specified and as directed.
Supply and fixing in replacement of surge protector device (SPD) of size 5-10 KV, suitable for LED street lights of size 45 & 60 watt including dismantling the street light poles and fixing the SPD, 230 volt 50Hz, complete all as specified and as directed.
Supply and fixing in replacement of surge protector device (SPD) of size 5-10 KV, suitable for LED street lights of size 120 watt including dismantling the street light poles and fixing the SPD, 230 volt 50Hz, complete all as specified and as directed.
Supply and fixing in replacement of LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete, all as specified and as directed.
All as per item No. 6 here-in-above but of 70 Watt capacity complete all as specified and as directed.
All as per item No. 6 here-in-above but of 60 Watt capacity complete all as specified and as directed.
Supply and fix in replacement LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with IP 65/66 protection complete all as specified and as directed.
Supply and fixing in replacement of LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, all as specified and directed.
Supply and fixing in replacement of automatic street light control switch panel 65 Amps, aesthetically appealing with locking facility, single phase 6-12 KW, contactor rating 65 Amp TP and MCB rating 63 Amps TPN astronomical time switch, Extended wide band coil, FRLS (Fire retardant low smoke) Internal wiring, In-built short-circuit Protection, Class H Insulationusing. Providing with IP 54 protection, the sensor along with suitable power contactors and incoming out going MCBs should be enclosed pole/wall mounted thermo plastic polycarbonate enclosure complete all as specified and as directed.
Supply and fix in replacement integrated auxiliary contactor 65 Amps, AC 3 phase, 220 to 415 volt, 50/60 Hz, three/four pole, contacts 2NO+2NC conforms to IEC/EN -60947-4-1 suitable for street light timer panels, complete all as specified and directed.
Supply and fix in replacement integrated auxiliary contactor 40 Amps, AC 3 phase, 415 volt, 50/60 Hz, three pole contacts 1NO+1NC conforms to IEC/EN -60947-4-1 suitable for street light timer panels, complete all as specified and directed.
Supply and fix in replacement street light panels analog time switch (without battery back up), 3P Module, 24 hours program, programmable every 15 min, current capacity 16 Amps, suitable for 63/40/32 Amps street light timer, AC 3 phase, 110-240 V AC (1CO) base/ Din 16 pulse digital time switch,complete all as specified and directed.
Supply and fixing PVC insulated copper cable 2.5 sqmm three core multistanded flexible 1100 volts complete all as specified and directed.
S & F as in replacement brackets 1.2 m long made to shape fabricated out of GI pipe Light grade ISI marked 40 mm dia incl provn of socket nipple welded at once end to suit the light fitting and fix to pole including clamps with nuts and bolts of suitable size cutting, drilling and welding its fix to pole and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Supply and fixing street light junction box of size 140 mm x 140 mm x 95 mm, made out of hot press moulded SMC with weather proof hinged door including self locking arrangement, out door type weather and vermin proof complete comprising of insulated / high quality PVC sleeves aluminium bus bar of capacity 63 Amps 04 Nos (three phase RBY and black for neutral) with and including 6 Apms MCB single pole, single phase 230 volts, including 25 x 3 mm flat iron mounted on insulators, having arrangement of connecting incoming and outgoing cables complete and all as specified and directed.
Suppy and fix rigid non-metallic PVC conduit 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete and all as specified and directed.
Supply and filling only distilled water for lead acid battery complete and all as specified and directed.
Supply and filling including topping up engine oil 15W30 Suitable for DG Set, complete all as specified and as directed.
Supply and filling coolant DAFC 30% Suitable for DG Set radiator, complete all as specified and as directed.
Servicing of DG set upto 10 KVA Make- Kirloskar, including replacement of unsv spare parts, alignment of Alternator, Minor reapir and complete checking of fuel Pump after necessary inspection of DG set complete all as specified and directed ( spares shall be measured and paid separately under respective items of schedule here-in-after from serial item no. 22.01 to 22.03):-
Supply only Filter kit comprising of Air,Fuel and oil filters.
Supply only Fan Belt as per sample.
Dismantling Radiator assy complete including cleaning, washing with cleaning equipment and refitting the same complete all as specified and directed.
M&L for Sevicing, repair maintenance including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing deposits and preparation of surface for painting checking of its all parts for serviceability and re-assembling all serviceable parts all as original including replacement of defective parts and minor spares required for functioning of DG set 40 & 50 KVA complete all as specified and directed. Make - Kirloskar, complete engine testing on load to the entire satisfaction of Engr-in-Charge. Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement shall be measured and paid seperately under appropriate items mentioned in Sch 'A' as supply only. 2. Other minor spares/parts required for repair/maintenance shall be deemed to included in quoted rate.
Fuel filter element with existing cat part (primary & secondry) complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Lube oil filter element with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Radiator hose pipe set with clamp complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Fan belt with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Starting ignition switch with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Push Button with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Packing Kit with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Fuel pipe any type length and specification with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Air filter element of existing specification with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Hose pipe (for make up water connect) complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Hose thermostate to radiator complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Dry type air cleaner complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Battery lead multi stranded copper conductor of size 10 sqmm single core with suitable copper lugs of length 1.5 Mtrs complete all as specified and directed.
Anti-Vibration pad made out of super quality butyl rubber ISI marked as per sample complete all as specified and directed.
Servicing of DG set 30 KVA ( Make- Kirloskar) including replacement of following parts alignment of Alternator, minor work and complete checking of fuel pump after necessary inspection of DG set complete all as specified and directed (spares shall be measured and paid separately under respective items of schedule here-in-after from srl item no. 24.01 to 24.13):- Note :- 1. All major defective/unserviceable spare parts/items reqd for replacement shall be measured and paid seperately under appropriate items mentioned in Sch 'A' as supply only. 2. Other minor spares/parts required for repair/maintenance shall be deemed to included in quoted rate.
Fuel filter element with existing cat part (primary & secondry) complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Lube oil filter element with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Radiator hose pipe set with clamp complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Fan belt with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Starting ignition switch with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Push Button with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Packing Kit with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Fuel pipe any type length and specification with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Air filter element of existing specification with existing cat part complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Hose pipe (for make up water connect) complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Hose thermostate to radiator complete all as specified and directed. Make:Kirloskar/Bosch/Mico
Battery lead multi stranded copper conductor of size 10 sqmm single core with suitable copper lugs of length 1.5 Mtrs complete all as specified and directed.
Anti-Vibration pad made out of super quality butyl rubber ISI marked as per sample complete all as specified and directed.
Taking out the self starter 12 Volt of DG Set Cap 10 KVA to 50 KVA and shifting to workshop for rewinding of armature including replacement of unserviceable,bushes & minor parts & reinstalling the same after testing complete all as specified and directed.
Supply and fixing in replacement Steel pinion complete all as specified and directed. Make as per existing.
Supply and fixing in replacement Clutch assy complete all as specified and directed. Make as per existing.
Supply and fixing in replacement Solenoid switch complete all as specified and directed. Make as per existing.
Supply and fixing in replacement Carbon brush complete all as specified and directed. Make as per existing: Lucas.
M&L cleaning of diesel tank of DG Set of any capacity including replacement of worn-out pipe line and measuring scale and fixing in original position and make it leak proof with necessary clamps complete all as specified and directed.
Taking out and calibration of fuel injection pump of DG set for 10 to 50 KVA and replacement of unserviceable parts incl Element, Delivery valve and bearing, refixing after repair from workshop either at location with complete testing, all as specified and directed.
S&F electric contactor suitable for AMF panel of DG Set 50KVA, 3 phase 4 wire, AC 415 Volts, 50Hz as existing make and capacity, complete all as specified and directed.
S&F electric contactor suitable for AMF panel of DG Set 40 KVA, 3 phase 4 wire, AC 415 Volts, 50Hz as existing make and capacity, complete all as specified and directed.
S&F electric contactor suitable for AMF panel of DG Set 30 KVA, 3 phase 4 wire, AC 415 Volts, 50Hz as existing make and capacity, complete all as specified and directed.
Supply and replacement of AMF panel auto start relay / as per existing and with copper wiring of AMF panel with suitable size wire complete all as sample of existing relay, complete all as specified and directed.
Supply and fix in replacement for nozzle assembly complete including testing to DG set, all as specified and directed.
Supply & install in repair Lead Acid Battery 12 V 150 AH complete all as specified and directed.
Supply & install in replacement of Battery Charger complete as per sample for DG set all as specified and directed. Make- Amarraja, Coronet Sukam, Luminous.
Supply & install in replacement of Inverter 1500 VA sine wave technology complete all as specified and directed. Make- APC, Sukam, Luminous.
Taking down and Supply, Fixing, Testing AVR for DG Set 30/40/50 KVA, 3 phase 4 wire, AC 415 Volts, 50Hz to sense the voltage in the main generator winding and control the power fed to the exciter stator and the main rotor to maintain the generator output voltage with in the specified limits, compensating for load, speed, tempreture and power factor complete with existing make & specification all as specified and directed by Engr-in-Charge.
Supply and fixing exhaust blow assembly as per existing type and model complete all as specified and directed.
M&L Dismantling the alternator of DG set of capacity 30/40/50 KVA, 3 phase 4 wire, AC 415 volts, from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connections of the alternator, shifting the alternator to work shop by crane and vehicle, opening into parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the "F" class insulation and existing gauge and type of magnet wire that was on the original motor, varnishing, heating, drying, greasing the bearings including replacement of unserviceable bearings, Re-fixing the complete including connection to the terminal box of the alternator at work shop and shifting the same to the site, Fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with the engine, connecting all electrical connections of the alternator and testing the DG set on "OFF/FULL LOAD", matching to the existing range of RPM of the engine, out put voltage 415 volt and testing all as per the direction of the Engr-in-charge.
Taking down the Dynamo 12/24 Volts from the existing position, shifting to the work shop and back , opening into parts, cleaning to sort out the unserviceable parts, replace by new one, rewinding and varnishing, heating of coil, reassembling and re-fixing to its base including to and fro conveyance charges for work shop to the site for any capacity of DG and all as per the direction of the Engr-in-charge.
Labour only for complete calibration for function and checking of AMF panel with and including minor repairs,tightening of wiring cables complete all as specified and directed at site.
Material and labour for painting by using spray painting method for DG set canopy/complete body/LT panel board (After removing incoming/out going electrical connection and refixing the same) with two coats of superior quality synthetic enamel paint after cleaning of existing surface, removing rust including marking of incoming/outgoing feeder with letters, MES/SM Nos (Maximum area of painting 3 Sq Mtr) and all as per the direction of the Engr-in-charge.
M & L for Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level connected to GI strip 32 x 6mm as earth lead by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover , charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 40mm dia GI pipe light grade for protection of GI strip, wire mesh and connected to earth point including testing on all as specified and shown in electric plate No 3 of SSR Part I.
Day to day complaints of street lights of various type for working height varies from 9m to 15m in the juridiction of AGE E/M, GE (N) Patiala within 15 km radious incl removing carbon from LED light connection by deploying dedicated team having the experience in the same field. Contractor has to provide all required Tool and plants for street light fault rectification. Contractor will make record of all given complaints and rectified complaints updated on daily basis. Street light complaints should be rectified within 24 hrs after intimation via any communication mode. Contractor is to collect serviceable lights from E/M stores and deposit U/S LED lights back to store. If the comaplint is not rectified within stipulated time contractor will bear penality of Rs 40 per day per complaint.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtr in depth for laying of cables errecting of pole including getting out in any kind of soil complete all as specified and directed.
All as per item no. 44 here-in-above but for exceeding more than 1.5 m in depth complete all as specified and directed.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, including spreading and leveling complete all as specified and directed. Note:-(i) Consolidated/punned sand shall be considered for purpose of payment. (ii) Sand shall be same as specified for plastering work
M & L for precast concrete cable covers type 2 flat, size 250mmx150mmx40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 10 sqmm 4.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately.
All as per item No. 50 here-in before but for cable of size 4 core 16 sqmm.
All as per item No. 50 here-in before but for cable of size 4 core 25 sqmm.
All as per item No.50 here-in before but for cable of size 4 core 35 sqmm.
All as per item No. 50 here-in before but for cable of size 3.5 core 50 sqmm.
M &l for PCC 1:4:8 TYPE D-2 using 40 mm graded broken stone aggregate as in mass concrete in foundations etc . complete all as specified and directed.
Cutting hard standing / road for laying of cable / protection pipe complete all as specified and as directed.
M&L for Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 to 80 mm bore GI tubing and cable etc complete all as specified and as directed.
AR CONSTRUCTIONS
m/s s.n. builders
M/s badrinath Traders
SHARMA ELECTRICAL ENGINEERS
FAVOURITE ENGINEERS
Bidder Name
AR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .