Loading…
Loading…
Tender Value
₹59.4 L
EMD Value
₹1.2 L
Closing Date
25 Jun 2026, 6:00 pm6d left
Similar tender results from the same govt authority in the past 3 years.
General Manager RSRDC Ltd. Jaipur
Office of the Project Director RSRDC Ltd. Unit-Electrical, Jodhpur. High Court Campus, Near Shatabdi Circle, Jodhpur
Additional Air Conditioning work at CCB Block, Barmer
2026_RSRDC_568422_1
RSRDC NIT 165/2026-27 (Sl-2)
Open Tender
Electrical Works
30 days
Barmer
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Through RTGS/NEFT/IMPS
₹1.2 L
16 Jun 2026
16 Jun 2026
29 Jun 2026
16 Jun 2026
25 Jun 2026
17 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having 100% hermetically sealed inverter type Scroll Compressor(s) with and minimum two compressors along with two Condensing fan, above 14/18 HP modules, microprocessor based Controller, Side / top discharge type condensing unit(s), with R-410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The EER at 100% load with AHRI conditions shall not be less than 3.5 and Including OEM supplied Piping connection Kit etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 87 | per HP | 24,270 | ₹21,11,490 |
| 2 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/
work , refer Annexure "A" attached with this BSR . | 0 | Nos | 0 | ₹0 |
| 3 | Un Armoured | 0 | Nos | 0 | ₹0 |
| 4 | 2 core x 1.5 Sq.mm | 457 | Mtr. | 94 | ₹42,958 |
| 5 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer
Annexure "A" attached with this BSR . | 0 | Nos | 0 | ₹0 |
| 6 | 25 mm | 72 | Mtr. | 229 | ₹16,488 |
| 7 | 32 mm | 50 | Mtr. | 296 | ₹14,800 |
| 8 | SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 652 | Kg | 1,987 | ₹12,95,524 |
| 9 | Supply , Installation, Testing and Comissioning of site fabricated ducting made from GI sheet metal conforming to IS:277 with a zinc coating grade not less than 120 GSM (both side inclusive) & fabricated as per IS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. Test Certificate for Galavanizing with lot no. to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A"
attached with this BSR . | 0 | Nos | 0 | ₹0 |
| 10 | 0.60 mm | 472 | Sq. Mtr. | 970 | ₹4,57,840 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
AgrrementRTPPandetc.pdf
Tender Documents • 2.75 MB
BankDetail00.pdf
Tender Documents • 0.17 MB
BOQ_1011216.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid