| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC GP RAM COLONY AMRITSAR JALANDHAR 144103 | AMRITSAR | AMRITSAR | PUNJAB | 144103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.4 L+₹1.7 L (9.24%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹23.0 L+₹4.3 L (23.1%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹23.6 L+₹4.9 L (26.4%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹24.8 L+₹6.1 L (32.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
12 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHISIANA
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (AF) BHISIANA, BATHINDA-151201
Repair and Maint of Split/Window ACs alongwith connected Works at AF Stn Bhisiana
2021_MES_443024_1
GE/BHI-10/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) BHISIANA
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) BHISIANA
₹50,000
Yes
8 Jul 2021
15 May 2021
14 Jun 2021
15 May 2021
12 Jun 2021
29 May 2021
17 May 2021 - 27 May 2021
60 days
Amount
Dismantling/taking down window type AC 1.5/2 Ton from site, opening, cleaning all dust with the help of air blower including cleaning of condenser and evaporator coil with Soap solution, removing the dust with the help of wire brush, repairing & proper fixing of wiring including thimbles and cleaning of Air filter Nylon and reinstalling AC in the same Location and made air tight to opening with thermacol material all around the window type AC complete and testing on full load etc complete all as specified and as directed.
Dismantling/taking down Split type AC 1.5/2 Ton from site, opening, cleaning all dust with the help of air blower including cleaning of condenser and evaporator coil with Soap solution, removing the dust with the help of wire brush, repairing & proper fixing of wiring including thimbles and Cleaning of air filter Nylon and reinstalling AC in the same location both unit outdoor/indoor unit complete and testing on full load etc complete all as specified and as directed.
S&F starting relay assembly including cover and clips for air conditioner window type 1.5/2 Ton capacity fixed in replacement complete all as specified and as directed by Engineer-in-charge.
S&F starting capacitor 100/120 mfd suitable for 1.5/2 Ton capacity of window type AC fixed in replacement complete all as specified and as directed by Engineer-in-charge.
S&F running capacitor 36/45 mfd suitable for 1.5/.2 Ton capacity of window type AC fixed in replacement complete all as specified and as directed by Engineer-in-Charge.
S&F capacitor 6 mfd suitable for blower motor, fixed in replacement complete all as specified and as directed by Engineer-in-Charge.
S&F Remote suitable for split/window AC any make/type all as specified and directed by Engr-in-Charge.
Taking down dismantling of old unserviceable defective sealed compressor of Cap 1.5 TR of window type AC and replacement with manufactures reconditioned Compressor Company Make hermatic sealed compressor of Cap 1.5 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut, bolt and washers as required and charging with Refrigerant R-22 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same.
S&F in replacement fan blade for window/split AC of 1.5/2.0 TR all as specified and directed by Engr-in-Charge.
M&L for re-wiring of complete Window type AC of Capacity 1.5 Ton with copper wire single core PVC cable of size 40/0.0076 with necessary sleeves, clip, thimble auto sweep switch etc.
S&F Cable of 3 core PVC sheathed copper flexible cable of size 70/0.0076 fixed in replacement complete all as specified and directed.
S&F Metal Clad Plug/Socket ‘top’ 15 Amps fixed in replacement complete all as specfied and directed.
S&F Single pole and Neutral enclosure with, two Pin and earth plug and Socket 240 Volts complete with one MCB 20/25 Amps including taking down existing all as specified and directed by Engineer-in-Charge.
S&F Blower Motor Single Phase 230 Volts, 50 Hz, 1/5 HP, 900 RPM suitable for Window type AC of capacity 1.5/ 2.0 TR fixed in replacement complete all as specified and directed.
S&F Filter Pad Nylon type suitable for Window type AC of Capacity 1.5 TR fixed in replacement complete all as specified and directed.
S&F Evaporator Coil assembly complete suitable for Window type AC of capacity 1.5 TR etc complete and recharging the refrigerant R-22 and Testing fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F Condensing coil assembly complete suitable for Window type AC of Capacity 1.5 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed.
S&F Front grill assembly complete suitable for Window type AC of Capacity 1.5 TR fixed in replacement complete all as specified and as directed.
M&L for cleaning the gas system with anti corrosive solution and recharging the refrigerant gas R-22/R-134a/R-410/R-32/R-407 with anti moisture substance and replacement of filter along with rectification of leakage system in the Window type AC of capacity 1.5 TR including installation at site and testing on full load complete all as specified and as directed by Engineer-in-Charge.
M&L for re-winding of Blower Motor of Window type AC 1.5 Ton capacity Single Phase 1/5 HP, 900 RPM with super enameled copper wire of existing gauge including replacement of bush, nut, bolts & washer etc complete all as specified and as directed by Engineer-in-Charge.
S&F Blower and blade assembly complete suitable for Blower Motor of Window type AC of Capacity 1.5 TR Ton fixed in replacement complete all as specified and as directed by Engineer-in-Charge.
M&L for repair to Voltage Stabilizer of Capacity 04/05 KVA Single Phase including replacement of circuit plate, starting relay, voltmeter, fuse terminal box with fuse carrier, rewinding the main Transformer with Copper wire of existing size and repair/replacement time delay relay (1-2 Min) Built-in type designed for low cut off 140/160 Volt, High cut off 260/280 Volt on single Phase, 50 cycle AC supply etc complete all as specified and as directed by Engineer-in-Charge.
Preparation of old painted surface and applying two coats of Ducco Paint by Spray Gun fully matched with its original colour outside of the Window type AC of Capacity 1.5/2 Ton including before painting removal of all dust with the help of air blower, sand paper and rubbing with cleaning compound and polishing on painted surface etc complete all as specified and as directed by Engineer-in-Charge.
Taking down /dismantling of old unserviceable defective sealed Compressor of Cap 2/1.50 TR of Split type AC and replacement in with Manufactures reconditioned Compressor Company Make hermatic sealed Compressor of Cap 2/1.50 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut, bolt and washers as required and charging with Refrigerant R-22/R-134a/R-410 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same.
Taking down /dismantling of old unserviceable defective Rotary Compressor of Cap 2/1.5 TR of Split type AC and replacement in new rotary Compressor of Cap 2/1.5 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut & bolt and Washers as required and charging with Refrigerant R-22/R-134a/R-410 to its rated Capacity and Testing of leakage in the system if any and making good, Testing on full load after reinstalling the same.
M&L for cleaning the gas system with anti corrosive solution and recharging the Refrigerant Gas R-22/R-134a/R-410/R-32/R-407 with anti moisture substance and replacement of Filter along with rectification of leakage system in the split type AC of Capacity 1.5/2 TR) on including installation at site and testing on full load etc complete all as specified and as directed by Engineer-in-Charge.
S&F decorated frame of plywood/teak ply of size 70mm wide and 3mm thick duly varnished of good quality, all around the Window type AC for air tight and fixing with screws on existing wooden frame complete all as specified and as directed by Engineer-in-charge.
S&F Insulation to Refrigerant pipes of Split ACs any Make & type complete with suitable size for suction and discharge refrigerant pipes including necessary clamps etc.
S&F thermostat suitable for Split/Window AC all as specified and directed by Engr-in-Charge.
S&F in replacement Oscilation Motor with swing blade strip for indoor unit of Split AC 1.5/2.0 TR capacity same specification/Make as per existing one complete all as specified and directed.
M&L for dismantling/taking down of existing Split type AC of Cap 2.0/1.5 TR complete with Indoor/Outdoor unit from existing location with all Electric Connection and all Refrigerant Pipes and matching the existing disturbed surface area, Including Refixing/Re-Installation of Split type AC Shifted to new location on suitable wall places complete all as specified and directed by Engr in Charge. (Refrigerant Recharging Gas, Insulation of Copper tubes, copper tubes paid & measured seprate under respective item).
Supply in replacement of Copper Pipe Line of size 1/4" to 1/2" for Split/Window type AC of any capacity complete all as specified and directed by Engr-in-Charge.
Supply in replacement of Copper Pipe Line of size 3/8'' to 5/8" for Split/Window type AC of any capacity complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of Brass flair nuts 1/2'' to1/4'' for Split/Window type AC of any capacity complete all as specified and directed.
Supply only in replacement of Brass flair nuts 3/8'' to 5/8'' for Split/Window type AC of any capacity complete all as specified and directed.
M&L for dismantling /Taking down of Window type AC 2/1.5 Ton Capacity from existing location carefully with all electric connection and connecting the same in new location and including the window opeaning filled with the brick masonary and cement plastering to match the existing disturbed surface area complete all as specified and directed by Engr-in-Charge.
S&F Fan Motor for Outdoor Unit of same specification as per existing one suitable for Split type AC of capacity 1.5 Ton fixed in replacement complete all as specified and directed.
M&L for Opeaning/Cutting holes in Brick wall suitable for window type AC 2/1.5 Ton and making good disturbed surface area complete with cement plaster and masonary work equired at site and made Air tight to opeaning with the Thermocoal Material all round the Window AC etc complete all as specified and directed by Engr-in-Charge.
S&F Evaporator coil assembly complete suitable for Split type AC of Cap 1.5 TR Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F Condensing coil assembly complete suitable for Split type AC of Cap 1.5 TR Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F connection lead 3 core PVC sheathed copper flexible cable of size 40/0.0076 complete with necessary thimbles etc, fixed in replacement, complete all as specified and as directed by Engineer-in-Charge.
M&L for writing/marking of SM No/MES No of size 25mm synthetic enamel paint on the water cooler of various Capacity/Split type AC's /Window type ACs etc complete all as specified and as directed by Engineer-in-Charge.
S&F Blower Motor for Indoor unit, same specification as per existing one suitable for Split type AC of capacity 1.5/2.0 Ton fixed in replacement complete all as specified and directed.
M&L for re-winding of Fan motor of window type AC 1.5 Ton capacity single phase 1/5 HP, 900 RPM with super enameled copper wire of existing gauge including replacement of bush, nut, bolts and washer etc complete all as specified and as directed by Engineer-in-Charge.
M&L for Submain wiring with two single core of 4 Sqmm and one single core of 2.5 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in non metallic rigid (ISI Marked) PVC conduit of size 25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surface.
M&L for Submain wiring with two single core of 6 Sqmm and one single core of 4.0 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in non metallic rigid (ISI Marked) PVC conduit of size 25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surface.
M&L for fixing of duel capacitor suitable for both Window/Split AC all as specified and directed by Engr-in-Charge.
M&L for replacement of complete Indoor Unit of Split AC of 1.5/2TR all as specified and directed by Engr-in-Charge.
M&L for replacement of complete Outdoor Unit of Split AC of 1.5/2TR all as specified and directed by Engr-in-Charge.
S&F in replacement complete PCB with Remote Control for Indoor unit of Split type AC cap. 1.5/ 2.0 TR, microprocessor based with transmission and receiving unit, cordless with features of mode slection, timer, temperature control or as per existing specification and model complete all as specified and directed.
S&F in replacement complete PCB with Remote Control for outdoor unit of Split type AC cap. 1.5/ 2.0 TR, microprocessor based with transmission and receiving unit, cordless with features of mode slection, timer, temperature control or as per existing specification and model complete all as specified and directed.
S&F in replacement of flexible type water drain out pipe suitable for Indoor unit of Split AC as per existing type /model complete all as specified and directed.
Attending day to day complaint of detecting the fault like loose nut and bolts, leakage of tube, checking electrical connections, charging of refrigerant, fan motor, compressor fault etc all as specified and directed. Note : Any defective part which are required to be replaced to Make functional ACs shall me measured and paid seperately.
S&F in replacement Blower assembly complete for Split AC of 1.5/2.0 Ton as per existing all as specified and as directed.
S&F in replacement LCD Digital type AC timer for cyclic operation of 02 any type of Air Conditioner with displaying AC 1/AC 2 on indication & 1 to 24 hours programmable to take load upto 2 Ton Window/Split AC with auto/manual facility at site all as specified & directed.
Aman Enterprises
M/s Luxmi Constructions
M/s Rohit Construction Co.
M/s Vee Kay Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .