| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC | ₹10.9 L Quoted ₹11.4 L | L1 | Accepted-AOC Acceptance Letter |
| 2 | L2₹11.9 LRejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | ₹11.9 L | L2 | Rejected-Finance Being other than Lowest |
| 3 | L3₹12.0 LRejected-Finance | ₹12.0 L | L3 | Rejected-Finance Being other than Lowest |
| 4 | L4₹12.3 LRejected-Finance | ₹12.3 L | L4 | Rejected-Finance Being other than Lowest |
| 5 | L5₹12.6 LRejected-Finance | ₹12.6 L | L5 | Rejected-Finance Being other than Lowest |
| Sl No | Description | Qty | Unit | M/S SMA and SONS CONSTRUCTIONS H3 | Top Mind Industries Pvt Limited H2 | M/S FAISAL TRADING CO. H5 | M/S M.A.S ELECTRICALS H1 | VEDA INFRASTRUCTURE H4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L and T&P for filling, checking & testing of refrigerant gas leakage in AC outdoor & indoor unit with ref gas line system of any type/size any model/make and in any position complete for of Spilt/cassette/tower type AC of rating capacity 1.5 Ton to 3.5 Ton 230Volt/415 Volt type including disconnecting of electric wiring/refrigerant gas connections & dismantling of required requisite body parts of AC unit system and also providing of N2 gas filling /putting/filling/charging of nitrogen gas (N2 Gas) by pressure to entire body system of complete AC unit system after checking / detecting and arresting of the refrigerant gas leakage problem in the AC system area and ensure that to carryout repairing/jointing work for all no's of leakage points/area with the help of welding/ brazing/soldering by electrode rod and after make it gas /air leak proof again after providing air vacuum pressure in system for holding gas to stand pressure in AC system upto satisfaction level, complete all as specified and directed.
Note- (i) The cost of on above quoted rate shall be deemed included for charging/filling and also required quantity of nitrogen gas (N2 Gas) for used no's of times by pressure for testing to each AC entire system, no extra cost shall be paid to the contractor for many time testing in each AC system.
(ii) All type of T&P, N2 cylinder and related of items shall deemed to be included in above quoted rates | 10 | EACH JOB | 3,000 ₹30,000 | 1,000 ₹10,000 | 3,400 ₹34,000 | 1,500 ₹15,000 | 500 ₹5,000 Lowest |
| 2.00 | Supply and fixing in replacement of single phase AC voltage operating type new one rotary shape sealed based compressor unit complete all as per existing type of sample and model with brief technical specification, parameters with rated capacity and size etc. of new replacing compressor shall properly match to each other as per the existing old replacement and suitable using it for non inverter model split type AC hot and cold based of rated capacity 1.5 ton unit system and including making/ jointing of electric and refrigerate gas pipe lines attachment connections thereafter completion of complete work . The AC shall run on trail, on load and to ensure that making it functional with smooth run and sound less and also operating properly as per the satisfaction level, complete all as specified and directed . | 15 | EACH | 7,000 ₹1,05,000 Lowest | 9,344 ₹1,40,160 | 7,500 ₹1,12,500 | 9,600 ₹1,44,000 | 10,000 ₹1,50,000 |
| 3.00 | Description all as per serial item No 02 here in before, but suitable using it for split type AC hot & cold based of rated capacity 2.0 Ton unit system, complete all as specified and directed . | 3 | EACH | 7,500 ₹22,500 Lowest | 10,540 ₹31,620 | 8,300 ₹24,900 | 12,300 ₹36,900 | 8,500 ₹25,500 |
| 4.00 | Description all as per serial item No 02 here in before, but suitable using it for window type AC hot & cold based of rated capacity 1.5 Ton to 2.0 Ton unit system, complete all as specified and directed . | 1 | EACH | 7,500 ₹7,500 | 4,500 ₹4,500 Lowest | 8,800 ₹8,800 | 10,900 ₹10,900 | 9,000 ₹9,000 |
| 5.00 | Description all as per serial item No 02 here in before but new one rotary shape sealed based compressor unit complete three phase AC voltage operating type new one rotary shape sealed based compressor unit suitable using it for non invertor model split type AC hot & cold based of rated capacity 2Ton to 3.5 Ton of 3 phase 415 Volt AC supply unit system, complete all as specified and directed . | 1 | EACH | 15,000 ₹15,000 Lowest | 19,380 ₹19,380 | 16,800 ₹16,800 | 25,000 ₹25,000 | 18,000 ₹18,000 |
| 6.00 | Supply & fixing in replacement of single phase DC voltage operating type new one rotary shape sealed based compressor unit complete all as per existing sample & model with brief technical specification, parameters with rated capacity & size/type etc of new replacing items shall properly match to each other as per the existing old replacement item and suitable using it for invertor model split type AC hot & cold based of rated capacity 1.5Ton unit system and including making/jointing of electric & refrigerant gas pipe lines connections thereafter completion of complete work The AC shall put on trail run on load to ensure that making it functional with smooth run and sound less and also operating properly as per the maximum satisfaction level & as well as all as decided, complete all as specified and directed. | 2 | EACH | 16,000 ₹32,000 | 13,505 ₹27,010 Lowest | 16,000 ₹32,000 | 14,000 ₹28,000 | 14,500 ₹29,000 |
| 7.00 | Description all as per serial item No 06 here in before, but suitable using it for split type AC hot & cold based of rated capacity 2.0 Ton unit system, complete all as specified and directed. . | 2 | EACH | 18,000 ₹36,000 | 15,695 ₹31,390 | 16,300 ₹32,600 | 15,000 ₹30,000 Lowest | 17,500 ₹35,000 |
| 8.00 | Supply & fixing in replacement of condensing coil with of tubes & fins unit complete all as per existing type of sample & model with brief rated capacity, size etc of new replacing items shall properly match to each other as per the existing old replacement item and suitable using it for outdoor unit system of split type AC hot & cold based of rated capacity 1.5Ton to 2.0 Ton system and including making/jointing of electric/refrigerant gas pipe lines connections thereafter completion of complete work ensure that making it functional & smooth run and sound less and also operating properly as per the maximum satisfaction level, complete all as specified and directed. | 5 | EACH | 3,500 ₹17,500 | 3,500 ₹17,500 | 7,500 ₹37,500 | 8,500 ₹42,500 | 2,200 ₹11,000 Lowest |
| 9.00 | Supply & fixing in replacement of outdoor unit electric fan motor of single phase AC/DC voltage operating type complete all as per existing type of sample & model with brief technical specification, parameters with rated capacity & size etc of new replacing items shall properly match to each other as per the existing old replacement item and suitable using it for non invertor/invertor model split type AC hot & cold based of rated capacity 1.5Ton to 2.0 Ton system and including making/jointing of electric/refrigerant gas pipe lines connections thereafter completion of complete work the AC shall put on trail run on load to ensure that making it functional & smooth run with sound less and also operating properly as per the maximum satisfaction level & as well as all as decided, complete all as specified and directed. | 6 | EACH | 2,800 ₹16,800 | 4,500 ₹27,000 | 2,600 ₹15,600 | 5,500 ₹33,000 | 1,800 ₹10,800 Lowest |
| 10.00 | Supply & fixing in replacement of outdoor unit fan blade complete all as per existing type of sample & model & size and suitable using it for window/split type of rated capacity 1.5Ton to 2.0 Ton system and to ensure that making it functional & smoothrun with sound less, complete all as specified and directed. | 10 | EACH | 900 ₹9,000 | 500 ₹5,000 Lowest | 1,500 ₹15,000 | 1,200 ₹12,000 | 500 ₹5,000 Lowest |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
1 Jul 2026, 6:00 pmClosed
GE 864 EWS
GE 864 EWS C/O 56 APO
REPAIRREPLACEMENT AND MAINT SERVICING OF AC AND REF APPLIANCES ALONG ITS CONNECTED MISC AND ALLIED WORK UNDER AOR OF GE 864 EWS AT BB CANTT, SRINAGAR
2026_MES_771229_1
864/WS-53(T)/2026-27
Open Tender
Civil Works - Others
Item Rate
180 days
BB cantt
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 864 EWS
₹32,000
Yes
14 Aug 2026
10 Jun 2026
8 Jul 2026
10 Jun 2026
1 Jul 2026
24 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L and T&P for filling, checking & testing of refrigerant gas leakage in AC outdoor & indoor unit with ref gas line system of any type/size any model/make and in any position complete for of Spilt/cassette/tower type AC of rating capacity 1.5 Ton to 3.5 Ton 230Volt/415 Volt type including disconnecting of electric wiring/refrigerant gas connections & dismantling of required requisite body parts of AC unit system and also providing of N2 gas filling /putting/filling/charging of nitrogen gas (N2 Gas) by pressure to entire body system of complete AC unit system after checking / detecting and arresting of the refrigerant gas leakage problem in the AC system area and ensure that to carryout repairing/jointing work for all no's of leakage points/area with the help of welding/ brazing/soldering by electrode rod and after make it gas /air leak proof again after providing air vacuum pressure in system for holding gas to stand pressure in AC system upto satisfaction level, complete all as specified and directed.
Note- (i) The cost of on above quoted rate shall be deemed included for charging/filling and also required quantity of nitrogen gas (N2 Gas) for used no's of times by pressure for testing to each AC entire system, no extra cost shall be paid to the contractor for many time testing in each AC system.
(ii) All type of T&P, N2 cylinder and related of items shall deemed to be included in above quoted rates | 10 | EACH JOB | - | - |
| 2 | Supply and fixing in replacement of single phase AC voltage operating type new one rotary shape sealed based compressor unit complete all as per existing type of sample and model with brief technical specification, parameters with rated capacity and size etc. of new replacing compressor shall properly match to each other as per the existing old replacement and suitable using it for non inverter model split type using it for non inverter model split type AC hot and cold based of rated capacity 1.5 ton unit system and including making/ jointing of electric and refrigerate gas pipe lines attachment connections thereafter completion of complete work . The AC shall run on trail, on load and to ensure that making it functional with smooth run and sound less and also operating properly as per the satisfaction level, complete all as specified and directed . | 15 | EACH | - | - |
| 3 | Description all as per serial item No 02 here in before, but suitable using it for split type AC hot & cold based of rated capacity 2.0 Ton unit system, complete all as specified and directed . | 3 | EACH | - | - |
| 4 | Description all as per serial item No 02 here in before, but suitable using it for window type AC hot & cold based of rated capacity 1.5 Ton to 2.0 Ton unit system, complete all as specified and directed . | 1 | EACH | - | - |
| 5 | Description all as per serial item No 02 here in before but new one rotary shape sealed based compressor unit complete three phase AC voltage operating type new one rotary shape sealed based compressor unit suitable using it for non invertor model split type AC hot & cold based of rated capacity 2Ton to 3.5 Ton of 3 phase 415 Volt AC supply unit system, complete all as specified and directed . | 1 | EACH | - | - |
| 6 | Supply & fixing in replacement of single phase DC voltage operating type new one rotary shape sealed based compressor unit complete all as per existing sample & model with brief technical specification, parameters with rated capacity & size/type etc of new replacing items shall properly match to each other as per the existing old replacement item and suitable using it for invertor model split type AC hot & cold based of rated capacity 1.5Ton unit system and including making/jointing of electric & refrigerant gas pipe lines connections thereafter completion of complete work The AC shall put on trail run on load to ensure that making it functional with smooth run and sound less and also operating properly as per the maximum satisfaction level & as well as all as decided, complete all as specified and directed. | 2 | EACH | - | - |
| 7 | Description all as per serial item No 06 here in before, but suitable using it for split type AC hot & cold based of rated capacity 2.0 Ton unit system, complete all as specified and directed. . | 2 | EACH | - | - |
| 8 | Supply & fixing in replacement of condensing coil with of tubes & fins unit complete all as per existing type of sample & model with brief rated capacity, size etc of new replacing items shall properly match to each other as per the existing old replacement item and suitable using it for outdoor unit system of split type AC hot & cold based of rated capacity 1.5Ton to 2.0 Ton system and including making/jointing of electric/refrigerant gas pipe lines connections thereafter completion of complete work ensure that making it functional & smooth run and sound less and also operating properly as per the maximum satisfaction level, complete all as specified and directed. | 5 | EACH | - | - |
| 9 | Supply & fixing in replacement of outdoor unit electric fan motor of single phase AC/DC voltage operating type complete all as per existing type of sample & model with brief technical specification, parameters with rated capacity & size etc of new replacing items shall properly match to each other as per the existing old replacement item and suitable using it for non invertor/invertor model split type AC hot & cold based of rated capacity 1.5Ton to 2.0 Ton system and including making/jointing of electric/refrigerant gas pipe lines connections thereafter completion of complete work the AC shall put on trail run on load to ensure that making it functional & smooth run with sound less and also operating properly as per the maximum satisfaction level & as well as all as decided, complete all as specified and directed. | 6 | EACH | - | - |
| 10 | Supply & fixing in replacement of outdoor unit fan blade complete all as per existing type of sample & model & size and suitable using it for window/split type of rated capacity 1.5Ton to 2.0 Ton system and to ensure that making it functional & smoothrun with sound less, complete all as specified and directed. | 10 | EACH | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_863660.xls
BOQ • 0.42 MB
Tender53_merged.pdf
Tender Documents • 1.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].