Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.6 LAccepted-AOC BINA ROAD PARASI P O KAKRI DISTT SONBHADRA UP | SONBHADRA | UP | L-1 | Accepted-AOC Technically acceptable and quoted rate lowest. |
| Sl No | Description | Qty | Unit | CHANDRA MOTOR REWINDING WORKS L1 |
|---|---|---|---|---|
| 2.00 | Part A: Spares required for repairing
HRFR insulated copper cable un-armoured size- 2.5 sqmmx 8 core x 1.1 kV | 45 | meters | 300 ₹13,500 Lowest |
| 3.00 | HRFR insulated copper cable un-armoured size- 6 sqmmx 4 core x 1.1 kV | 45 | meters | 300 ₹13,500 Lowest |
| 4.00 | HRFR insulated copper cable un-armoured size- 2.5 sqmmx Single core x 1.1 kV | 1,200 | meters | 25 ₹30,000 Lowest |
| 5.00 | HRFR insulated copper cable un-armoured size- 6 sqmmx Single core x 1.1 kV | 300 | meters | 70 ₹21,000 Lowest |
| 6.00 | HRFR insulated copper cable un-armoured size- 10 sqmmx Single core x 1.1 kV | 180 | meters | 130 ₹23,400 Lowest |
| 7.00 | HRFR insulated copper cable un-armoured size- 16 sqmmx Single core x 1.1 kV | 180 | meters | 180 ₹32,400 Lowest |
| 8.00 | HRFR insulated copper cable un-armoured size- 25 sqmmx Single core x 1.1 kV | 180 | meters | 300 ₹54,000 Lowest |
| 9.00 | HRFR insulated copper cable un-armoured size- 150 sqmmx Single core x 1.1 kV | 75 | meters | 1,800 ₹1,35,000 Lowest |
| 10.00 | Lug Size- 2.5 sqmm | 800 | Nos | 4 ₹3,200 Lowest |
| 11.00 | Lug Size- 4 sqmm | 200 | Nos | 5.5 ₹1,100 Lowest |
Tender Value
₹5.7 L
EMD Value
₹7,100
Closing Date
9 May 2025, 11:00 amClosed
Staff Officer (Excavation)
Office of the General Manager, Kakri Project, NCL
Repair or rewiring work of electrical panels and circuit of PandH-I (EXC-1282) Electrical Rope Shovel at Kakri Project.
2025_NCL_334548_1
KKR/SO(Excv)/E-03/25-26/40
Open Tender
Excavation Department Work
Item Rate
10 days
NCL Kakri Project
Please refer Tender documents.
4 documents required · 4 mandatory
₹7,100
24 Oct 2025
24 Apr 2025
10 May 2025
24 Apr 2025
9 May 2025
25 Apr 2025
24 Apr 2025 - 28 Apr 2025
Amount
Part A: Spares required for repairing HRFR insulated copper cable un-armoured size- 2.5 sqmmx 8 core x 1.1 kV
HRFR insulated copper cable un-armoured size- 6 sqmmx 4 core x 1.1 kV
HRFR insulated copper cable un-armoured size- 2.5 sqmmx Single core x 1.1 kV
HRFR insulated copper cable un-armoured size- 6 sqmmx Single core x 1.1 kV
HRFR insulated copper cable un-armoured size- 10 sqmmx Single core x 1.1 kV
HRFR insulated copper cable un-armoured size- 16 sqmmx Single core x 1.1 kV
HRFR insulated copper cable un-armoured size- 25 sqmmx Single core x 1.1 kV
HRFR insulated copper cable un-armoured size- 150 sqmmx Single core x 1.1 kV
Lug Size- 2.5 sqmm
Lug Size- 4 sqmm
Lug Size- 6 sqmm
Lug Size- 10 sqmm
Lug Size- 16 sqmm
Lug Size- 25 sqmm
Lug Size- 50 sqmm
Lug Size- 120 sqmm
Lug Size- 150 sqmm
Consumables items like ferul 0-9, A-Z, 2.5 sqmm, 4.6 sqmm, PVC tape, Bal bottom, Nut and Bolts, Screw, plane washer, spring washer, cello tape, likoplast etc
Part B: Labor Charges for wiring work HT cables dismantling laying, lugging and termination charges (Junction box to HT Ring, HT Ring to HT Cabinet, HT Cabinet to HT Motor and capacitor, VCBs, Auto Transfer, Main Transformer and Wiring HT Cabinet)
Cables (armature) dismantling, laying, lugging and termination charges (CP Generator to 12A, 12B, Shunt, rewiring of LV Ring, propel motor and Crowd motor, Swing Generator and left and right swing motors)
DC cables (Fields) dismantling, laying, lugging and termination charges (CP Generator Field, Swing Motor Field, Propel Motor Field, Crowd Motor Field and Magnetorque)
LT Cables dismantling, laying, lugging and termination charges (MG Set Blower Motor, Swing Blower Motor, Propel Blower Motor, Chain case lubrication Motor, Dipper trip Motor, Trip Resistor, Control cabinet blower motor, Boom Junction Box Propel, Junction Box Limit Switches, Lubrication system etc)
Control cables and wires dismantling, laying, lugging, internal circuit reoair of panel and termination charges (Control cabinet cable and wires, Auxillary cabinet cables and wires, Operator cable, wiring of crowd junction box to crowd motor and boom junction Box, Limit Switches)
Control cabinet wires, contactors, relays, timer, terminal block, MCBs, Dismantling, lugging, fitting and complete control cabinet wiring charges
Anod Transformer, Resister, Thyristor Panel and FCM Panel dismantling, fitting, lugging and complete wiring charges
Auxillary cabinet wires, contactors, relays, timer, MCCBs, terminal block dismantling, lugging, fittinmg and complete control cabinet wiring charges
Tools and tackles etc
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_346804.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .