Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹86.1 LAccepted-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | L-1 | Accepted-Finance Due to L-1 | |
| 2 | L-2₹87.2 L+₹1.1 L (1.32%)Rejected-Finance 90 MYLAPORE CHENNAI TAMIL NADU 600004 | CHENNAI | TAMIL NADU | 600004 | L-2 | Rejected-Finance Due to L-2 | |
| 3 | L-3₹89.1 L+₹3.0 L (3.48%)Rejected-Finance 55 KENCHAPPA ROAD FRAZER TOWN BANGALORE BANGALORE KARNATAKA 560005 | BENGALURU URBAN | KARNATAKA | 560005 | L-3 | Rejected-Finance Due to L-3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not meeting NIT criteria |
Tender Value
₹90.7 L
EMD Value
₹1.8 L
Closing Date
12 Aug 2024, 4:30 pmClosed
SM (E-E)
SM (E-E), AMED-VIII, AAI Chennai Airport
Facility Management of HVAC installations at Terminal buildings at CIA for the year 2024-26. SH- Rate contract for HVAC Installations at Terminal buildings at Chennai International airport
2024_AAI_201972_1
AAI/CHN/E-E/HVAC/ARC/24
Open Tender
Electrical Works
Item Rate
730 days
Chennai
Please refer Tender documents.
18 documents required · 18 mandatory
₹1,180
₹1.8 L
12 Sept 2024
22 Jul 2024
13 Aug 2024
22 Jul 2024
12 Aug 2024
22 Jul 2024
22 Jul 2024 - 29 Jul 2024
Amount
Replacement of existing damaged M S Class 'C' / MS ERW, insulated chilled water pipe lines of following sizes (nominal Dia) along with all necessary accessories such as vibration isolators bends, reducers, tees, supports, flow indicators and fixing clamps of suitable size and thermally insulated with specified insulation materials etc., inside the Terminal building / masonary ducts including dismantling of damaged pipe lines and replacing with new insulated pipe lines, testing and commissioning etc., as per technical specfication complete as required
100 mm dia
65 mm dia
50 mm dia
Replacement of existing damaged M S Class 'C' / MS ERW, condenser water pipe lines of following sizes (nominal Dia) with necessary clamps, vibration isolators bends, reducers, tees, supports, flow indicators etc as per specification including dismantling of damaged pipe lines and replacing with new pipe lines, testing and commissioning etc., as per technical specification complete as required
350 mm dia
150 mm dia
100 mm dia
65 mm dia
Replacement of existing damaged G.S.S square / rectangular ducting of following thickness, to be fabricated at site complete with gaskets, elbows, splitters, vanes, supports including dismantling of damaged duct and replacing with new one, etc as per technical specification complete as required.
18 gauge
20 gauge
22 gauge
24 gauge
Replacement of existing damaged Thermal insulation, aluminium foil faced resin bonded fibre glass insulation of following thickness (on duct) of density 24kg/cu.m after applying two coats of cold setting adhesive (CPRX compound) sealing all joints with self adhesive aluminium tape, covered with G.I. wire mesh netting on the outside, including dismantling of damaged insulation and replacing with new insulation, complete etc. as per techincal specification as required.
25 mm thick
50 mm thick
Replacement of existing damaged XLPE insulation of following thickness (on duct), Class'O' after applying suitable adhesive sealing all joints with self adhesive aluminium tape, including dismantling of damaged insulation, necessary cleaning of duct surface and replacing with new insulation, complete etc. as per technical specification complete as required
13 mm thick
25 mm thick
Replacement of existing damaged Nitrile rubber insulation of following thickness (on duct) , Class'O' after applying suitable adhesive, sealing all joints with self adhesive aluminium tape, including dismantling of damaged insulation, necessary cleaning of duct surface and replacing with new insulation, complete etc. as per technical specification complete as required
13 mm thick
25 mm thick
Replacement of existing blocked / damaged AHU Cooling coils of the following specifications i/c necessary modification of Chilled water pipe connection, insulation, including dismantling of blocked/ damaged cooling coil and replacing with new cooling coil, testing, commissioning etc., as per technical specification complete as reqd. No. of Rows = 6, Size of MS Header = Minimum 2 inch dia, Size of Copper pipe = 1/2 inch dia Thickness of copper pipe = Minimum 0.41mm Thickness of Aluminium fin = 0.15mm No. of Fins = 4.7 Nos/cm
Replacement of following size existing rusted Volume control dampers made of 16 SWG thick GI sheet, box type, low leakage, opposed blades, suitable links, levers and quadrants as required for their proper operation, control or setting devices, position indicating device, including dismantling of rusted Volume Control dampers and replaced with new one, testing and balancing, etc. as per technical specification complete as required
Buffing / Polishing for the column diffusers made of perforated stainless steel having approximate surface area of 11 Square meter, installed in Check-in & Security hold area at Domestic & International terminal buildings using suitable buffing compound as per technical specification complete as required.
Dismantling, Rewinding & Refixing of 3 Ph, 5 Hp capacity motors of Smoke extractor fans installed at roof of terminal buildings i/c replacement of old bearings with new bearings, Painting of motor and as per technical specification complete as required.
Replacement of existing worn out bearings of 3 Phase, 5 HP capacity Motors of Smoke Extractor fans installed at roof of terminal buildings i/c necessary cleaning, lubricating, alignment, including dismatling the worn out bearing and replace with new one, etc. as per technical specification complete as required.
Fabrication, Supply and fixing of MS supports, frames for chilled water pipelines, Condenser water pipelines, Cooling towers and ducts from floor and ceiling with 'L' angle, 'C' section, 'I' section, MS Plates, threaded rod, etc as required including necessary welding, anchor fastener (wherever required), one coat of primer painting & two coat of rustproof marine grade paint of approved color etc, as per specifications.
Painting of Angles, frames of chilled water pipelines, Condenser water pipelines, Cooling towers and ducts from floor and ceiling with 'L' angle, 'C' section, 'I' section, MS Plates, threaded rod, etc with one coat of primer painting and two coat of rustproof marine grade paint of approved colour etc as required .
Installation, testing and commissioning of of existing dismantled Aircurtains of following size at Entry, Exit and Trolley gates of Terminal building including necessary drilling, tapping,suitable fixing arrangements, clamps, bolt nuts, screws, electric power supply cable with plug top etc., required.
3 Feet Aircurtain
6 Feet Aircurtain
Provision of fiberglass re-inforced (FRP) lining on existing/New MS/GI pipe line/supports/platform external surface with two layers of (Each layer 1mm thick) fibre glass chopped standard mat on the surface bonded with isophthalic based polyester resin and finally smooth finishing the surface with 0.5mm FRP sheet and adhesive paint; including cleaning, wrapping, fixing with binding components & pigment compound layer as per technical specification complete etc as required.
Painting of HVAC rectangular grills, square aluminium grills, jet nozzles and any other AC vents/outlets etc. including removing & re-refixing (if required) with one coat of primer painting and two coat of enamel paint of approved colour and make etc as required .
Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class 'O' on existing chilled water pipelines applied by suitable adhesive, as per specifications and as required complete in all respect.
Dismantling of rectangular supply/return air grills from the existing false ceiling including Measuring, Marking & Cutting required size in the false ceiling, Fixing of the same rectangular supply air grill in the false ceiling by providing reapers as per site requirement, fixing the grill to the duct using screws, etc. as complete as required i/c Scaffolding.
GEMINI COOLING SYSTEMS PROJECTS PRIVATE LIMITED
TF AIR SYSTEMS PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .