| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹15.8 L+₹1.0 L (7.05%)Rejected-AOC VILLAGE POST JAGANOO TEHSIL UDHAMPUR JAGANOO UDHAMPUR1 UDHAMPUR JAMMU KASHMIR 182124 UDYAM JK 22 0011509 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹16.2 L+₹1.5 L (10.2%)Rejected-AOC 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹28,700
Closing Date
11 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U(N) 58 2021 22 REPAIR TO CERAIN MISC B R AND EM WORKS AT RR UNDER GE NORTH UDHAMPUR
2021_MES_478513_3
GE/U(N)-58/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NORTH UDHAMPUR
₹28,700
Yes
11 Feb 2022
19 Nov 2021
13 Dec 2021
19 Nov 2021
11 Dec 2021
26 Nov 2021
60 days
Amount
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed by Engineer in Charge
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with galvanised 8mm dia 'J' hook/self tapping screws all as specified and directed'
S & F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with galvanised 8mm dia 'J' hook/self tapping screws complete all as specified and as directed by Engineer in Charge
Dismantling wrought iron or mild steel work of any description not otherwise provided fo complete all as specified and as directed by Engineer in Charge
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe 410 -W (Gde- E- 250) quality- complete all as specified and as directed by Engineer in Charge
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed by Engineer in Charge
S&f false ceiling with fiber cement designer tile lvory/white painted (high pressure steam cured)of 4mm thickness (as per IS-14862 )of size 595X595mm and any one of the design (occeanic,lake & hill cascade or electra) in true horizontal level,suspended on interlocking power coated certa black pattern metal grid of hot dipped galvanised steel section(galvanised @12gms both side inclusive ) consisting of main T runner with suitably spaced joint to get required length and 15X32 mm made of 0.30mm sheet spaced between main T@600mm C/C from a ridge of 600X600mm and wall angle of size 15X20mm made of 0.30mm thick sheet and laying false ceiling tile in the grid including required cuttig /making opening for service like diffuser grils light suspended from ciling using GI soffit cleats fixed to existing rafters purlin etc with dash fastener GI adjustable rod of 3mm dia with galvanised butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T-sections shall be centre black prepainted with poiyester paint and having a load bearing capacity of 12kg/sqm and refixed all existing electric wiring and fixture complete all as specified and as directed by Engineer in Charge
M&L for 10mm thick cement screed in cement mortar 1:3, including finishing even and smooth with out using extra cement to receive roof treatment, mixed with water proofing compound (ratio of WPC and cement - 2%) over and including a neat cement slurry @ 3 Kg/Sqm over cleaned roof surface, as in grading to RCC roof surface, including taking down existing water proofing treatment includes (PCC padding, cement plaster, APP etc) from top of roof, scrubbing down with water etc. any description, complete all as specified. Note - Water proofing compound shall be measured and paid separately.
Supply only integral water proofing compound complete all as specified and as directed by Engineer in Charge
M&L for water proofing roof treatment, consists of a Atactic polypropylene modified polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with LPG torch forced application over roof surface, with a side & end overlaps of minimum 100 mm, with and including priming @ 0.40 lit/Sqm the surface with a coat of hot blown bitumen of grade 85/25 @ 1.2 kg/Sqm each at top and bottom of the membrane as bonding material, and a coat of bituminous aluminium paint @ 100 gm/Sqm on top, including sealing all joints by thermo fusion, complete all as per manufacturer's instructions and as specified and as directed by Engineer in Charge
Taking down cement or cement lime plaster skirting dado of any description from brick or stone walls/ceilings etc including raking out joints hacking for key, scrubbing down with water complete all as specified
M&L for (10+5) mm thick rendering in CM 1:4 on fair faces of brick work or concrete surface including finished even and fair all as specified. Including 10mm wide grooves at junction of wall/ cols/ beams etc all as specified and as directed.
Material and labour for preparation of new plastered surfaces of walls and applying two coats of cement based paint white or tinted over a coat of chalk whitening primer complete all as specified and as directed by Engr-in-charge.
M&L 10 mm thick rendering on other than fair faces of brick work or concrete surface in CM 1:6 including finishing even and smooth without extra cement complete all as specified and as directed by Engineer in Charge
M&L for rendering 10mm thick on ceiling surfaces in CM 1:3, complete all as specified and as directed by Engineer in Charge
M&L for prepration of newely plaster surfaces and aplying 3 coat of white wash on wall surfaces complete all as specified and as directed by Engineer in Charge
M&L for prepration of newely plaster surfaces and aplying 3 coat of white wash on ceiling surfaces complete all as specified and as directed by Engineer in Charge
M & L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide prime complete all as specified and as directed by Engineer in Charge
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre lineover fittings and accessories)complete all as specified & directed.
S&F 110 mm dia PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls with Clamps complete all as specified and directed
S&F 110 mm bore PVC (SWR) bend any radius complete all as specified and as directed by Engineer in Charge
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal from site of 15mm bore of pipe complete all as specified & directed
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal from site of 20mm bore of pipe complete all as specified & directed
S&F Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 20mm bore complete all as specified & directed by Engineer-in-Charge.
S&F Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 15mm bore complete all as specified & directed by Engineer-in-Charge.
S&F for 5mm thick PVC insulated wall lining honey combed as per sample kept in GE Office consisting of PVC insulated panels with approved colour and design printed PVC sheet used colour PVC sheet duly fitted into the wall including PVC sheet in strips feathered at the edges including removing and refixing electric switch boards and plate and covered with PVC strips or beading after after fixing wall panelling as per specifaction complete all as specified.
M&L for demolition of brick work/stone masonry built in cement mortar and removal of rubbish from site complete all as specified and directed.
M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified & directed by Engineer-in-Charge.
M&L for Disconnecting existing tanks exc 500 n exc 1000 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified & directed by Engineer-in-Charge.
S&F Rotational moulded polyethylene water storage tanks three layered white in colour (cylindrical vertical with closed top) hoisted and fixed in position of 1000 ltr capacity including provision of inlet, outlet overflow and wash out connections and taking down the unserviceable tank complete all as specified & directed by Engineer-in-Charge.
S&F Ball valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (min. weight 20mm-210 gms) complete all as specified & directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in any description and in any position not other wise provided for and removing the debris to a distance not exc 100m from site complete all as specified & directed by Engineer-in-Charge.
M&L for Plain cement concrete Type B-1 1:2:4 (20mm graded aggregate) , cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engr-in-Charge.
S&F non skid ceramic coloured tiles of 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but n,exc 0.38sqm in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 10mm thick screed bed in CM 1:4 complete all as specified & directed. .
S&F glazed ceramic tiles in vertical surface 450X 300X 7mm thickset and jointed in neat cement slurry and pointed in white including 10mm thick rendering screed bed in CM 1:3 complete all as specified & directed.
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed by Engineer-in-Charge.
M&L for plain cement concrete 25mm thick levelling course type B-1, 1:2:4 (20mm graded aggregate) as in floor complete all as specified & directed by Engineer-in-Charge.
Taking down chowkats or frames not exceeding 1.5 Sqm each but with shutters (without taking off shutters from the frames) incl making good all respects as specified and directed by Engineer-in-Charge
Taking down chowkats or frames of any description with shutters (without taking off shutters from the frames) area exceeding 1.5 Sqm but n exc 4 sqm each all as specified and as directed .
S&F Stainless steel wire cloth, 0.36mm dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass ordinary quality 4.8 mm thick, frosted & glazing with oil putty in squares n exc 0.5 sq.m in each pane complete all as specified & directed by Engineer-in-Charge.
M&L for providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge NOTE Weight of all sections members shall be measured by convening a board of officers before execution of above work
M&L for providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators(sliding / openable etc) including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge NOTE Weight of all sections members shall be measured by convening a board of officers before execution of above work .
Dismantling loose/ disintegrated portion of RCC chajjas, bends, shelves ,beam,balconies and similar work at any position or any height and dubbing out with PCC 1:1.5:3 15mm to 50mm thick using 6-12mm gradded aggregate to make up and finished required shape including necessary form work and including 10mm thick plaster in CM 1:3 finished fair and even complete all as specified & directed by Engineer-in-Charge.
M&L for Framed work such as grills, gratings, hold fasts etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, ladders framed balusters, and similar work conforming to Fe-290-0 or Fe-310-0, incl portions framed and hung as gates, pintle hinges,stops,hand-made sliding bolts etc complete all as specified & directed by Engineer-in-Charge.
S&F in repairs Bib taps of 15mm dia chromium plated cast copper alloy of fancy type screwed down for iron pipe complete all as specified & directed by Engineer-in-Charge.
S&F brass chromium plated Angle stop/stop valve 15mm high pressure screwed for iron pipe and fixed, complete all as specified & directed by Engineer-in-Charge.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
S&F in repair water closet white vitreous china ware Orissa pattern of size 580x440mm with integral foot rest ‘P’ or ‘S’ trap 100mm dia front or back inlet incl provision of PCC bedding type B1, 1:2:4 ( 20 mm graded aggregate) and connection pipes ( excluding flushing cistern but including flushing pipe 32 mm dia MS chromium plated) (rate also include for taking off unhygienic of WC).
S&F in repair PVC high/low level flushing cistern of 10 ltr capacity fixed including syphonic action type,ball valve, float and handle including brackets and suitable pvc bends fixed to WC etc complete all as specified and directed.
S&F in repairs Brass chromium plated shower rose of size 125 mm with swivel joint fixing to GI pipe of 15mm dia complete all as specified and directed.
S&F Plastic water closet seat, back cover, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified & directed by Engineer-in-Charge.
Taking down carefully the existing Copper/Aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface of walls, floors etc., complete all as specified and directed by Engr -in- charge. Note : (i) Old dismanteled wiring and accessories (other than reuse) will be contractors property and credit will be charged against schedule of credit.
Taking down carefully by unscrewing from boards / outlet boxes fittings and fixture such as, LED bulk head fitting, LED tube light fitting etc. for re use at site or carrying to the store (serviceable fitting shall be reuse) all as specified and as directed by Engineer in Charge.
Taking down Old Serviceable/unserviceable MCB DB any type/size etc after disconnecting (serviceable DBs /MCBs shall be reuse), complete all as specified and directed by Engineer in Charge.
M&L for Point wiring for One light/fan/exhaust fan point controlled by one one way switch 5 Amp with 1.5 Sqmm single core multi standed copper conductor FRLSH insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated drawn into and including concealed PVC rigid conduit of not less than 20mm dia ISI marked terminated into annealed steel terminal boxes including 3.00 mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and directed by the Engr-in-charge.
All as per item Srl No. 56 above but for bell / buzzer on independent board controlled by one push button bell switch.
All as per item Srl No. 56 above but for one 5 Amps socket outlet on independent board.
All as per item Srl No. 56 herein before but for 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engr -in-charge.
All as per item Srl No. 56 bove but wire size 2x4 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLSH 1100 volts grade un sheathed single core stranded copper conductor cable of size 4 Sqmm.
S&F Switch Piano flush type single pole 5 Amps One way, all as specified and directed by Engineer- in - Charge.
S&F Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type complete all as specified and directed by Engineer- in - Charge.
S&F Socket outlet Two in one, 3/5 Pin piano type 10 Amp and 20 Amp flush type complete all as specified and directed by Engineer- in - Charge.
S&F Switch Piano type single pole 16/20 Amps One way, complete all as specified and directed by Engineer- in - Charge.
S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as specified and directed by Engineer - in - Charge.
S&F Electric bell (Ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and as directed by Engineer in charge
S&F switch piano flush type for bell Push 5 Amps, complete all as specified and directed by Engineer- in - Charge.
S&F Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked complete all as specified and directed by Engineer- in - Charge.
Fixing only serviceable light fittings any type as obtained against item No 54 all as specified and directed by engineer in charge
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by Engineer in Charge.
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item no 70 Engineer in charge.
M&L for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth all as specified and directed by Engineer in Charge.
Sub main wiring with two run single core 6 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia PVC concealed conduit medium grade ISI marked with all accessories such as Tees, elbows, junctgion boxes etc, as required fixed on wall alongwith one run of 6 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continious earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable submain of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 6 sqmm and one run 6 sqmm cable and one run of PVC conduit shall be measured as one RM
All as per item No. 73 herein before but with 4 sqmm pvc copper conductor cable through pvc conduit ISI marked with 4 sqmm copper conductor cable as earth contiunity conductor.
S&F Switch Piano flush type single pole 5 Amps one way fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F switch piano flush type for bell Push 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Socket outlet Two in one, 3/5 Pin piano type 5 Amp and 15 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Switch Piano type single pole 16/20 Amps One way, fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Switch socket combination piano type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Switch socket combination piano type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body fixed in replacement, complete all as specified and directed by Engineer - in - Charge.
S&F Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Electric bell(Ding dong) AC 230/250 volts grade single pole ISI marked fixed in replacement, complete all as specified and as directed byEngineer in Charge.
S&F Switch socket combination Box type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Switch socket combination Box type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 8 Way all as specified and directed by Engineer in Charge.
All as per srl item No 87 above but 4 way, complete all as specified and directed by the Engr-in-Charge.
All as per srl item No 87 above but 12 way, complete all as specified and directed by the Engr-in-Charge.
Supply and fixing in repair sheet metal enclosure VTPN 4 way 415 volt 250 Amp rated bus bar double door type,mechanical impact strength IK09 with suitable for mounting MCCB for incomer and MCBs for outing without MCCB and MCB, IP-54 protection grade fixed flush to wall complete including cable connections should be provide with necessary reducer lugs complete all as directed by Engr-in-Charge.
All as per srl item No 90 above but 6 way, complete all as specified and directed by the Engr-in-Charge.
S&F MCCB 4 pole, 415 volt, Adjustable type 160 Amp with breaking capacity 16 KA all as specified and directed by Engineer in Charge.
S&F MCCB 4 pole, 415 volt, Adjustable type 200 Amp with breaking capacity 25 KA all as specified and directed by Engineer in Charge.
S&F in replacement ultra modern designed arechitectural 2x2 LED, 6500K, 36/40 watt luminaire which provides soft light and glare free symmetrical illumination (VENUS NEO), complete all as per the direction of Engr-in-Charge. Make -Make of LED -Wipro as per ordering code D414065 or equivalent model in Havells or CG or as per the sample as approved by Accepting Officer
S&F connection and testing 'C' series SPN MCB 40 to 63 Amp 240V, 50Hz, 10kA for lighting and other domesitc loads incl necessary copper lugs etc all as specified and as directed by Engineer in charge.
Supply and fixing, connection and testing 'C' series MCB SP6-32 Amps all as specified and as directed by Engineer in charge.
Supply and fixing connection and testing 'C' series MCB SP 40 Amps. all as specified and as directed by Engineer in charge.
S&F Isolator 4 Pole 100 Amp, 415 Volts- all as specified and as directed by Engineer in charge.
S&F in repair rigid non- metalic PVC casing and caping of 25/12 mm inclusive of all elbow, tees, etc complete all as directed by Engr- in- Charge.
S&F in repair LED 4 pin PLL Lamps (Retro fit) 18 Watt all as specified and as directed by Engineer in Charge.
S&F angle lamp holder Pvc /Polycorbonate type with back plate suitable for batten fitting all as specified and as directed by Engineer in charge.
M & L for replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 240 volt capacity complete all as directed.
S&F MCB TPN 63 Amps four pole 415V including all termnials, fitting etc all as specified and as directed by Engineer in charge.
S&F Slim linear LED lighting fixture 4/5W watt LED batten, with full base of extruded poly carbonate isolated driver, complete making all connection from ceiling rose to fittings including testing complete all as per the direction of Engr-in-Charge. Make of LED -Syska Cat No:SSK-SQ0401/Wipro Cat No : D530565/C&S Cat No: LTTBIF5WLED/W/ Havells: Cat No: LHEXBXPNIN1W005 or as per the sample as approved by Accepting Officer
S&F decorative ultra slim linear polycarbonate Extruded LED lighting fixture 10/12 Watt LED of input voltage AC 220V-240V, 50 Hz with colour tempetrature 6500K more than 1080 lumens of IP 20 complete making all connection using 1.5 sqmm copper conductor multistranded PVC insulated twin core flexible cable from ceilingrose to fitting complete all as directed by Engr-in-charge. Make Syska Cat No: SSK-SQ1201 Wipro Cat No : D531065/Havells: Cat No: LUMILINEPLUSBS10WLED865SPCSS/ Philips Cat No : BN 021 LED10S- 6500 PSU GR S1 or as per the sample as approved by Accepting Officer
S&F Slim linear LED lighting fixture 20 Watt LED batten, P.F greater than 0.9, input voltage range from 90 Volts to 280Volts with full base of polycarbonate extruded section acting as a heat sink with closed back isolated driver complete making all connection using 1.5sqmm copper conductor multistranded PVC insulated 2 core flexible cable with from ceiling rose to fitting complete all as specified and as directed byEngineer in Charge.Make Make : Syska Cat No: SSK-SQ2001/Havells Cat No: LHEXBXPNIN1W020/ or equivallent to Wipro or as per the sample as approved by Accepting Officer
Supply and fixing LED Bulk head (6500K) fitting of 09/10 Watt surface mounting type extruded aluminium body with diffuser complete with testing all as specified and directed byEngineer in Charge. Make Syska Cat No: SSK-BH-9W /Wipro Cat No : DA11265/Crompton :Cat No: LBHE-10-DL /Havells: Cat No: RUGBYNEONFT10WLED860SSYMTOPC or as per the sample as approved by Accepting Officer
M&L Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of MES Part-1 fixed in replacement including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC Pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of Earthing. Note : (a) On testing after completion of earthing, if the desired earth resistnace is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction ot the engineer incharge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing
S&F in repair PVC conduit medium grade 20mm dia ISI marked with all accessories such as tees , elbows, junction boxes etc complete all as per the direction of Engr-in-Charge
All as per srl item No 109 above but 25mm, complete all as specified and directed by the Engr-in-Charge.
NARESH KUMAR KHAJURIA
SHIVAE CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .