Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 CrAccepted-AOC | ₹5.6 Cr Quoted ₹5.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.4 CrRejected-Finance AZAD NAGAR GOLDEN TEXTILE SAMOR KHEMANI ROAD ULHASNAGAR 2 | THANE | MAHARASHTRA | 421002 | ₹5.4 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹5.5 CrRejected-Finance 503 4 BHOSALE DYNASTY SHITOLE NAGAR OLD SANGVI PUNE 411027 | PUNE | PUNE | MAHARASHTRA | 411027 | ₹5.5 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹5.6 CrRejected-Finance | ₹5.6 Cr | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
21 Jan 2026, 4:00 pmClosed
CO
KBMC
INTERIOR WORK OF MAHASABHA OF ADMINISTRATIVE BUILDING AT KULGAON BADLAPUR MUNICIPAL COCUNCIL
2026_DMA_1268412_1
KBMC/PWD/2755/2025-26
Open Tender
Civil Works - Others
180 days
KBMC
Please refer Tender documents.
6 documents required · 6 mandatory
₹6,589
₹1.5 L
KBMC
2 Jun 2026
15 Jan 2026
22 Jan 2026
15 Jan 2026
21 Jan 2026
15 Jan 2026
16 Jan 2026
PART A - CIVIL WORK
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
Providing and Fixing Acoustic Ceiling with Composite Polyfiber Board Acoustic Panel (make Anutone, Techno Acoustic, Silence Acoustic or equivalent), Fixed to GI Framing as per Manufacturers Specifications, including 1000/50 Polyester Fiber Wadding (Micron, Anutone, Dupont, Maxon or equivalent) fitted in G.I. Frame with Chicken Mesh (if required) ,GI Framework (Gyp Steel, Ultra or Equivalent) including., Plywood Batten framing for fixing/ pasting board, Hangers, fastners, taping & filling joints of Board etc as per design drawings and Manufacturers Specifications including making Cove, patterns, grooves etc completed at any height / level, as directed by Engineer Incharge / Architect.
Providing and Fixing Wooden Ceiling with 12 mm Fire Retardant Plywood Including 1000/50 Polyester Fiber Wadding (Dupont, Maxon, Micron, Anutone or equivalent) fixed to GI Framing (Ultra, Gyp Steel or Equivalent) as per manufactureres specification, Plywood finished with 1 mm thick Approved Laminate, including grooves, coves, pelmets, adhesive, hardware, scaffolding etc as per design drawings and as directed by Engineer Incharge / Architect. (FR Plywood Make -Merino, Kenwood, Galaxy, Sonear, Associate or equivalent (Laminate Make Sonear, Merino, Greenlam or equivalent)
Providing and Fixing Wooden Paneling with 12 mm Fire Retardant Plywood Including 1000/50 Polyester Fiber Wadding (Dupont, Maxon, Micron, Anutone or equivalent) fixed to GI Framing (Ultra, Gyp Steel or Equivalent) as per manufactureres specification, Plywood finished with 1 mm thick Approved Laminate, including grooves, coves, pelmets, skirting, adhesive, hardware, scaffolding etc as per design drawings and as directed by Engineer Incharge / Architect. (FR Plywood Make -Merino, Kenwood, Galaxy, Sonear, Associate or equivalent (Laminate Make Sonear, Merino, Greenlam or equivalent)
ACOUSTICAL WALL PANELLING – FABRIC WRAPPED OF SIZE: 600 X 600/ 1200 X2 5MM Providing and Fixing of Acoustical Wall Panel with square edges made of fibre glass substrate 25mm thick, wrapped on the front side with an acoustically transparent fabric as per the approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell). The panel shall be classified for Fire Class A, as per ASTM E84. The Acoustical Wall Panel shall be of sizes 600x600mm (Nominal) or 600x1200mm (Nominal) and shall achieve an NRC of 0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) with 50mm airgap as per ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers (supplied by the manufacturer) or by using construction adhesives (as per the instructions laid down by the manufacturer). The fibre glass substrate shall have a recycle content of 85%. Installation:An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer’s recommendation. Install wooden batten grid (provided by others) of section 50x50mm or as approved by the Architect on the solid wall/partition to provide level and plumb surface. The Impalers shall be fixed to the battens using self-tapping screws, 3 nos. in case of 600x600mm and 4 nos. in case of 600x1200mm. Silica based construction adhesive (by others) to be dabbed on to the projecting elements (spikes) of the Impalers. Wall Panels shall be pierced through the spikes of the Impalers ensuring the line and level of the panels are maintained
STAGE- Quarter circle shaped stage having width 3.4 m and arc length is 8.65 m .It is made up of Wooden framing of 50mm x 50mm size teakwood vertical and horizontal supports placing at distance of 1200mm center to center . 50mm X50mm size teakwood bracings in between . Tenon and mortise joint is used Fixing 19 mm thick FR Plywood over the Wooden Frame 50 x 50 mm frame, Voids in the Frame to be filled with dry river sand. Including fixing Solid Wood FLooring 18 to 20 mm thick including Polishing / Finishing etc completed .Height of stage is upto 1000 mm. 18 mm thick teakwood side support running throughout arc length will have laminate finish . There is 100mm wide niche/ Cove below stage for lighting ( refer drawing for detail).Outer edge of niche is laminate finish .
Providing and Fixing Loop Pile Nylon / Polyproplene Carpet, 700 GSM, heavy commercial grade, Fire Retardent, Stain resistant, including 6 mm underlay as per approved design.
A curved shaped free standing unit with arc length as per drawings . Unit includes seats and desk . 400mm width seats are made of foam 40 density with rexin finish whole unit made up of Wood & Commerical Plywood, natural finished veneer with melamine polish. Veneer sheet having size 8'x4' and price upto Rs.3500 per sheet .
Viewing Gallery Chairs
Mahasabha Chief Chairs
waiting area sofa make godrej
Auditorium Chairs
Providing and Fixing Edge Proctection Angle for Auditorium Steps in 100 x 100 x 2 mm Aluminium angle fixed with screws as diected by Engineer Incharge / Architect
Glass partition above bund wall in viewing gallery is double sandwich 18mm thick toughened glass fixed in Aluminium extruders Height of glass partition is 3000mm.This partition is curved shaped.
Providing and Fixing S.S. Hand railing fabricated from 75mm S.S. pipe section . Fixed to the floor with 6mm Thick SS base plate with cover plate fixed with anchor bolt as per requirement at site etc. Height of railing is 500 mm.curved shape railing .
Providing and Fixing Wooden Acoustic Fire Rated Doors 2 hrs Fire Rating Finished with 1 mm thick Laminate , 75 mm thick Non-metallic,Asbestos Free Accoustic cum fire/smoke door of 120 minutes fire rating, confirming to BS:476 part 22 IS:3614 part-II,suitable to achieve approx. 38db, sound reducing properties suitable for fixing in wooden door frame of suitable section 175X75mm made out of Hard wood and the shutter comprising of 2 non-combustible boards sandwiching 41mm thick fire resistant & accoustic insulation filler.The shutter is faced with 6mm thick ply on both faces and hard wooden lipping all around the shutter with heat activated intumescent fire seal strip of size 20*4mm on all sides except bottom(for smoke sealing)both in frame & shutter.The door shall have suitable arrangement only for the provision for Accoustic seals for sound reduction properties. Also includes Concealed Door Closure, Handles, Hinges, Dead lock etc completed
Providing and fixing 3.5 to 4 mm thick Veneer finish wall Panaling made out of 50 x 25 mm (finished size)C.C.T.W. framework or size of 600 x 600 mm center or as per site condition covered by 6 mm thick marine plywood of the generally confiriming to I:S710-1980 finished with 3.5 to 4 mm thick matching Veneer of approved color and insatin wall nut groov matched veneer pattern and design including melamine polishing & design with antitermite treatment etc. to plywood and wood work with ten years guarantee bond etc. including all lead and lifts complete as per Architects Drawing and instructions of Engineer Incharge.
Suppling, Drilling/ Cleaning hole and fixing make heavy duty ETA Approved Chemical Anchor of appropriate size and fixing plates sub sequently. Anchor comprises of HVU- 2 flexible foil capsule that contains styrene free Urethane Methacry lateresin, hardener, quartz, sand/ corundumand HAS-U threaded rod of minimum 5.8 steel grade, galvanized to minimum 5 microns. Anchor should be approved for cracked concrete, seismic & diamond drill holes. Manufacture should submit Anchor Design report based on design loads & other parameters as provided by consultants. Chemical anchors should be designed in accordance with EOTA-TR-029 “guidelines for anchorage of chemical anchors for use in concrete” for approval. Application at site should be done as per manufacturer guidelines. Any report submittal with Installation pictures should be done using CFS- DM Software, which shall be charged extra. Anchor HVU2+HA SUM 30 x 270
Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars Re 500 -8mm dia 160mm depth
Re 500 -10mm dia 200mm depth
. Re 500 -12mm dia 240mm depth
Re 500 -16mm dia 320mm depth
Re 500 -20mm dia 400mm depth
Re 500 -25mm dia 500mm depth
Re 500 -32mm dia 640mm depth
Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Lifting of span and bearing locations by suitable hydraulic jacks connected by high pressure, rubber hoses to pump & removal of old exsting bearing ( Roller side only) As per Quotation
Supplying and erecting PVC slotted box trunking of size 100x100 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX.
Supplying and erecting modular type USB Charger socket of 1 Module with nominal output voltage of 5V DC ±5% and nominal output current of 5 V - 750 mA , duly erected on provided plate and box with wiring connections complete.
Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty.
Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50including driver with 1 year warranty.
Supplying and erecting modular pop up Box 8 module erected with provided AV/ HDMI , RJ 45,6 A electrical sockets and switch on provided table.
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution ofall items for such works.
Double Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 900mmD Providing and fixing Double Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 900mmD - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm. GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on thevlast unit when all units are brought together, central lock when operated gets locked withvvthe floor & does not allow access to the units. DRIVE MECHANISM : DrivingvMechanism will be provided externally supported on special grade anti-friction bearing tovhave smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area ofv1000mm x 200mm x 60mm. DRIVING WHEEL : Fully Powder Coated three prongedvdrive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns).
Floor Directories Providing and fixing acrylic multilingual Braille (raised dots)ADA compliant modular floor directories system on all floors of size1.5' x 2' , showing the floor plan and the list of rooms on that floor, to be installed on each floor near the staircase, designed as per standards and having 4mm thick blue acrylic base plate with Upper Case San Serif words and symbols made of white acrylic non glare cut out letters of height 20mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare imported acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. Each directory to be fixed as per manufacturers specifications on the wall at the approved location at a height of 1200mm from FFL and as per the directions by the engineer in charge.
Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work)
TESTING CHARGES+ROYALTY
ADD 18% G.S.T. (S.G.S.T. 9% + C.G.S.T. 9%)
ADD (1% Insurance)
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.28 MB
TenderNotice.pdf
Tender Documents • 1.26 MB
BOQ_2184747.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid