Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 CrAccepted-AOC | ₹17.6 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹18.4 CrRejected-Finance | ₹18.4 Cr | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹18.6 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹18.6 Cr | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹18.9 CrRejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹18.9 Cr | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹18.9 CrRejected-Finance | ₹18.9 Cr | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹16.3 Cr
EMD Value
₹11.4 L
Closing Date
18 Aug 2020, 6:00 pmClosed
CE Jodhpur Zone
HQ CE Jodhpur Zone
Provn of Auditorium cum Cinema Hall at Jaisalmer
2020_MES_345091_1
800448/JSLR/2020-21/E8
Open Tender
Civil Works
1620 days
Jaisalmer
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE Army Project No 01 Jaisalmer
₹11.4 L
Yes
Jodhpur
4 Sept 2020
15 May 2020
20 Aug 2020
15 May 2020
18 Aug 2020
4 Aug 2020
26 May 2020
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl Page No 29 (R) (R).
Lump sum price worked out by the contractor for "SITE CLEARANCE, EXCAVATION & EARTH WORK" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 31(R)
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.32 (R)
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.35 (R)
Lump sum price worked out by the contractor for "ROAD, PATH, CULVERT & HARDSTANDING etc." as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.37 (R)
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 39 (R)
Lump sum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES B/F from Sl page No.41 (R)
Lump sum price worked out by the contractor for "COMPOUND WALL & GATE" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.44(R)(R).
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 45 (R)
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.49 (R)
Lump sum price worked out by the contractor for "LIGHTNING PROTECTION " as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 50(R)
Lump sum price worked out by the contractor for "SUMMER APPLIANCES" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 51(R)
Lump sum price worked out by the contractor for "FIRE FIGHTING AND FIRE DETECTION " as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.54 (R)
Lump sum price worked out by the contractor for " AIR CONDITIONING " as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.55 (B)
Lump sum price worked out by the contractor for " ARBORICULTURE " as listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.55 (C)
Sch 'A' Sec-XVI (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-II (Excavation and earthwork schedule).
INTERNAL WATER SUPPLY
M&L, bib tap, cast copper alloy (ISI marked), with wall flange, screwed down high pressure for iron pipe/fittings or for brass ferrule, ISI marked, of size 15 mm bore of Make JAQUAR, Product range: Opal Prime, Product Code: OPP-CHR-15037PM or of equivalent complete all as specified and directed
M&L, stop cocks, cast copper alloy chromium plated with crutch or butter fly handle, screwed down, high pressure screwed both ends for iron pipe/fittings or for brass ferrule of 15mm dia bore of make JAQUAR, Product range: CONTINENTAL, Product Code: CON-CHR-083FTK or of equivalent, complete all as specified and as directed.
M&L, angular stop cocks, cast copper alloy chromium plated with crutch or butter fly handle, screwed down, high pressure screwed both ends for iron pipe/fittings or for brass ferrule of 15mm dia bore of make JAQUAR, Product range: CONTINENTAL, Product Code: CON-CHR-059KN or of equivalent, complete all as specified and as directed.
S&F 20mm bore brass chromium plated tubular towel rail, 'D' type, 60cm long between flanges, of make JAQUAR, Product Code: CAN-1111SM or of equivalent, complete all as specified.
S&F sensotronic mini concealed type flushing valve for Urinal complete set with installation box as per make JAQUAR, Product Code: SNR-STL-51083 or of equivalent, complete all as specified and directed
INTERNAL ELECTRIFICATION:
Supply & Fixing 15 Amps Pop-up Sockets Flush Mounitng boxes with push & slide Locking system near to stage completes directed .all as specified and directed engr-in-charge
S & F of recessed mounted LED accent light with aluminum die cast housing having 36° beam spread, CCT 4000 K, CRI > 80, initial power input 42 W, PF ≥ 0.9, system efficacy 95 lm/W, IP 20 & IK 02 protection, 2.5 kV surge protection, median useful life L70B50 ≥ 30000 hrs and a replacable flicker free driver having ripple factor < 5% including electrical connection with 3 core 1.0 mm² PVC insulated copper conductor wire from ceiling rose to the fixture complete all as specified and directed. Make Philips as per Cat No. RS271B LED40/840 PSU-E MB WH / crompton cat No CDR-215-40-40-SL-NWH or technocommercial equvivalent of make as approved by GE.
S & F 4' water-proof LED batten with CRCA housing & optical cover diffuser having, power rating 40 W, luminous efficacy ≥ 100 lm/W, CCT 6500 K, CRI ≥ 80, IP 65 & IK 06 protection, PF ≥ 0.90, 2.5 kV surge protection, median useful life L70B50 ≥ 30000 hrs and a replacable flicker free driver having ripple factor < 5% including electrical connection with 3 core 1.0 mm² PVC insulated copper conductor wire from ceiling rose to the fixture complete all as specified and directed.Make Philips as per Cat No. WT201C LED40S-6500 PSU L 120 / Crompton Cat No CIS-300-40-57-SL-DP-NGR or technocommercial equvivalent of make as approved by GE.
S & F 4' LED batten with CRCA housing & optical cover diffuser having, power rating 40 W, luminous efficacy ≥ 120 lm/W, CCT 6500 K, CRI ≥ 80, IP 65 & IK 06 protection, PF ≥ 0.90, 2.5 kV surge protection, median useful life L70B50 ≥ 30000 hrs and a replacable flicker free driver having ripple factor < 5% including electrical connection with 3 core 1.0 mm² PVC insulated copper conductor wire from ceiling rose to the fixture complete all as specified and directed. Make Philips as per Cat No. BN100C LED40S-6500 PSU L 120 GR / Cromption Cat No CIS-300-40-57-SL-DP-NGR or technocommercial equvivalent of make as approved by GE.
S & F recessed mounted 2 ' X 2' LED panel with CRCA housing & optical cover having , power rating 36 W, luminous efficacy ≥ 100 lm/W, CCT 6500 K, CRI ≥ 80, PF > 0.9, 50000 hrs lifetime @L70B50 at 45 °C, IP 20 & IK 03 protection,median useful life L70B50 ≥ 30000 hrs and a replacable flicker free driver having ripple factor < 5% including electrical connection with 3 core 1.0 mm² PVC insulated copper conductor wire from ceiling rose to the fixture complete all as specified and directed. Make Philips as per Cat No. RC380B LED36S-6500 G4 L60 W60 PSD OD / Cromption Cat No LCTLRNE-36-FO-CDL or technocommercial equvivalent of make as approved by GE.
S & F recessed mounted LED downlight with CRCA housing & optical cover having , power rating 22 W, luminous efficacy ≥ 100 lm/W, CCT 6500 K, CRI ≥ 80, PF > 0.9, 50000 hrs lifetime @L70B50 at 45 °C, IP 20 & IK 03 protection,median useful life L70B50 ≥ 30000 hrs and a replacable flicker free driver having ripple factor < 5% including electrical connection with 3 core 1.0 mm² PVC insulated copper conductor wire from ceiling rose to the fixture complete all as specified and directed.Make Philips as per Cat No. DN 395B LED20S-6500 PSU WH / Cromption Cat No CDR-206-20-57-SL-NWH or technocommercial equvivalent of make as approved by GE.
S & F recessed mounted LED downlight with CRCA housing & optical cover having , power rating 10.6 W, luminous efficacy ≥ 100 lm/W, CCT 6500 K, CRI ≥ 80, PF > 0.9, 50000 hrs lifetime @L70B50 at 45 °C, IP 20 & IK 03 protection,median useful life L70B50 ≥ 30000 hrs and a replacable flicker free driver having ripple factor < 5% including electrical connection with 3 core 1.0 mm² PVC insulated copper conductor wire from ceiling rose to the fixture complete all as specified and directed. Make Philips as per Cat No. DN 392B LED10S-6500 PSU WH / Cromption Cat No CDR-205-12-57-SL-NWH or technocommercial equvivalent of make as approved by GE.
S & F recessed mounted LED downlight with CRCA housing & optical cover having , power rating 6.5 W, luminous efficacy ≥ 100 lm/W, CCT 6500 K, CRI ≥ 80, PF > 0.9, 50000 hrs lifetime @L70B50 at 45 °C, IP 20 & IK 03 protection,median useful life L70B50 ≥ 30000 hrs and a replacable flicker free driver having ripple factor < 5% including electrical connection with 3 core 1.0 mm² PVC insulated copper conductor wire from ceiling rose to the fixture complete all as specified and directed.Make Philips as per Cat No. DN 391B LED6S-6500 PSU WH / Cromption Cat No CDR-204-06-57-SL-NWH or technocommercial equvivalent of make as approved by GE.
Supply & fixing of 2.7 W LED foot/ step lighting fixture complete with driver & in all respect including testing & commissioning on completion. Make Philips cat No. BWG150 LED50/NW PSU 220-240V IP67 7043 /Cromption Cat No LSL-6-CDL or technocommercial equvivalent of make as approved by GE.
S & F LED mirror light suitable for wall mounting & 220- 240 V, 50 Hz mains voltage with built-in LED & driver, power rating 7.5 W, including IP 20 protection as well as electrical connection with 3 core 1.0 mm² PVC insulated copper conductor wire to the fixture complete all as specified and directed. Make Philips cat No. 34034/14/86 /Cromption Cat No LDL-10-CDL or technocommercial equvivalent of make as approved by GE.
Supply and fix street light fitting LED lamp type 45 W single phase 240 V with all fittings/fixtures prewired, gear cum reflector made of CRCA sheet steel, canopy made of Die cast aluminum painted with stove enameled white paint inside and grey outside, highly transparent clear ribbed acrylic cover held in aluminum frame and screwed to canopy with rubber gasket with hing arrangement including 25 mm dia galvanised iron pipe light grade bracket bent to shape over all length 1.6 mtr fixed to wall with 2 Nosclamps made of flat iron of size 25 x 6mm and suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 Sqm three core from ceiling rose to fitting all as specified and directed, Make Philips cat No. BRP052 LED 036 CW HP SLA FG S1 PSU GR/Cromption Cat No LSTS-30-CDL-M or technocommercial equvivalent of make as approved by GE.
Supply, installation, testing and commissioning of UL certified signal dimmer controller of polycarbonate DIN rail enclosure (12 unit) construction suitable for 100- 240 V, 50 Hz AC supply voltage, 0.5 A supply current, IEC overvoltage category III, operating temperature 0- 40 °C, < 90% RH (non-condensing), IEC pollution degree II having 1 X RS-485 serial port, Dynet / DMX Rx protocol, 12 control channel outputs, 1 (auxiliary) dry contact input, user input (1 X service switch, 12 X channel override), indicators ( 1 X diagnostic LED, 12 X channel status LED), diagnostic functions (device online/offline status), etc. complete all as specified and directed.Make Philips cat No. dYNALITE DDBC1200 / Crompton CTR Series, Cromption RF (BLE) with system or technocommercial equvivalent of make as approved by GE.
Supply, fixing and testing ceiling fan of 1200 mmsweep, 23 0 Volts, single phase, 50 Hz 3 blades, double ball bearing BLDC FAN , BE rating connection up (Dust Resistance) complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 sqmm from ceiling rose / connector, including extra GI / MS pipe down rode, as per site requirement (approximate length 01 Mtr) complete all as specified and directed Make Crompton Cat No. Energion or techono commercial equvivalent of make as approved by GE.
S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make Crompton cat No. Brisk Air 250 mm or technocommercial equvivalent of make as approved by GE.
S & F engery efficient metalic exhaust fan having blade sweep 450 mm, air delivery not less than 6000 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make Crompton cat No. Turbo force SP or technocommercial equvivalent of make as approved by GE.
S & F vertical triple pole & neutral DB, 6- way (double door), conforming to IEC 61439- 3, suitable for flush mounting with 100 A insulated & shrouded copper busbar for each phase, 2 fully insulated & shrouded neutral bar, 2 earth bar, wire set and cable ties for cable management, IP 43 & IK 09 protection with reversible metal door with provision for FP MCCB as incomer and TP/SP MCBs as outgoing, all complete as specified and directed. Notes : [i] MCBs/MCCBs shall be measured and paid in separate items.
S & F ISI marked MCB for AC applications till 63 A, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed.
6 A, SP MCB, C- curve
16 A, SP MCB, C- curve
20 A, SP MCB, C- curve
32 A, SP MCB, C- curve
40 A, SP MCB, C- curve
32 A, FP MCB, C- curve
16 A, DP MCB, C- curve
32 A, DP MCB, C- curve
32 A, TP MCB, C- curve
S & F 63 A four pole moulded case circuit breaker (MCCB), conforming to IEC 60947-2, having Ics = 100% of Icu = 25 kA, adjustable thermal setting (0.7 - 1 X In) and fixed magnetic setting with compression lug connectors and thermal magnetic trip unit (TMD) all complete as specified and directed.
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, four runs of 6 sqmm main cable and one runs of 6.00 sqmm earthwire conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 25 mm NB PVC medium grade recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, all complete as specified and directed. Note: - Four runs of main cable + one run of earth conductor and one run of PVC conduit shall be measured as one RM.
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, 2 runs of 6.00 sqmm main cable and one runs of 6.00 sqmm earthwire conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 25 mm NB UPVC medium grade recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, all complete as specified and directed. Note: - Two runs of main cable + one runs of earth conductor and one run of UPVC condduit shall be measured as one RM.
ROAD/PATH/CULVERT & HARDSTANDING
M&L for 150 (spread thickness) Grade-I Granular sub base as per MORT&H specifications beneath the Wet mix macadam upto the required density to form true surface, spread, surface binding with, watered consolidated and rolled with 8 to 12 tonne power roller to gradient and camber all as specified and as directed.
M&L for 150 mm thick (compacted thickness) ready mix wet mix macadam (WMM) using materials of 30 CBR, in two layers each of 75 mm thick (each layer to be rolled and consolidated seperately) confirming to the grading given in table 400-13 and physical requirements given in table 400-12 spread with mechanical means as specified, hollows made upto for true surface, spread, surface binding with and including screening and moorum, watered, consolidated and rolled with vibratory roller 8 to 12 tonne as per clause 406.3.5 of MORT&H to required gradient and camber complete all as specified and as directed.
M & L factory made Precast PCC Kerbs stone of design mix M-20 grade of size and shape and thickness as approved by GE, laid set jointed and pointed in CM 1:3 including excavation of earth work, complete all as specified and directed.
S&F speed breakers (ABS) of size 350mm long, 250mm wide and 50mm high in yellow and black colour (alternative) as per product code AP-1004 of make ACME or approved manufactures instruction complete all as specified and directed. MAKE: DARK EYE / SPARK EYE / ALXIS / ACME.
S&F cat eye two way reflective of size 100x100x18.5mm with aluminium body with reflective panels Amber/ Red / White complete all as specified and directed. MAKE: DARK EYE / 3M / TATA /road star/Alfa gold Seimens or equivalent.
S&F road delinator made out of 65mm internal dia MS circular hollow pipe of 750mm long medium weight ends covered with 150mm x 150mm x 3mm thick and top end covered with 100 x 100 x1.00 mm thick mild steel plain sheet, the top portion covered with white and coloured high intensity prismatic grade retro reflective sheeting in 50mm wide strips of each colour (150mm width), reflective band shall be covered with a protective grill of mild steel wire 2mm dia and 15mm to 20mm aperture upto the height of 170mm duly painted including fixing in ground with PCC 1:3:6 type C2 using 40mm graded stone aggregate of size300mm x 300mm x 450mm including necessary excavation and earth work painting to steel surfaces with two coat of synthetic enamel black paint over a coat of red oxide primer complete all as specified and directed. MAKE: DARK EYE / 3M / TATA / BP or equivalent
S&F traffic sign board of triangular shape with 30cm length each side with MS sheet 2mm thick including MS pipe medium grade 60mm dia of height 2.0m above GL and 0.6m below GL and including excavation of post holes, removal & packing with PCC 1:3:6 type C2 of size 45cmx45cmx60cm complete including with & including retro reflective sheet of approved colour paste on MS sheet both sides & necessary letter/arrow/emblame etc. writing with retro reflective tape as directed as for road sign board,, painting, fixing etc complete all as specified & directed.
M&L for marking of centre line, stop line, dahses, arrows, letters, brackets & similar work on road surfaces as per IRC pattern with 2mm thick thermo plastic compound of approved quality using 8% mica of white/yellow colour as approved of temperature 160 degree C with special applicator machine including cleaning of road to remove all loose dirt etc, traffic diversion arrangement complete all as specified & directed. MAKE: ASIAN / SHALIMAR / SN industries-Delhi / Maruti Reflo Mark or equivalent as approved by GE.
SEWAGE DISPOSAL
M & L for brick masonry Septic tank designed to carry sewage and sullage water, excavation in soft/disintegrated rock, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete for 150 users all as per drawing NO. CEJZ/STR/STD/12/2016.
Construction of soakage wells excavation,in soft/disintegrated rock,foundation in PCC 1:3:6,walls of honey combed masonary with top ring of M-25 concrete RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.60 m dia x 3.00 m. deep for 150 users all as per drawing No. CEJZ/TD/29.
EXTERNAL WATER SUPPLY
Supply & laying for centrifugally cast (spun) ductile iron pressure pipe of 150 mm bore with socket & spigot ends including specials having ISI stamping marking with IS 8329/2000, classification K7 in standard length of 5.50/6.0 mtrs, suitable for and including push on joint (gasket 'D' jointing) with cement mortar lining complete all as specified & directed.
Supply & laying for centrifugally cast (spun) ductile iron pressure pipe of 100 mm bore with socket & spigot ends including specials having ISI stamping marking with IS 8329/2000, classification K7 in standard length of 5.50/6.0 mtrs, suitable for and including push on joint (gasket 'D' jointing) with cement mortar lining complete all as specified & directed.
M & L for cutting of CI/DI water mains raising pipe line upto 350 mm in exisiting position for branch connection including M & L for insertion of DI Tee of size 350 mm x 150 mm x 350 mm including lead joints,collars,rubber coupling,nuts,bolts of size suitable including accessories complete all as specified.
Supply, installation, testing and commissioning of manufacturer's factory assembled and tested electric driven Monoblock pump set of capable of delivering 30 LPS at 35 mtr head comprising of horizontal split casing pump single stage CI body with CI impellers coupled through a flexible coupling to a electric driven 3 phase motor 415 V not less than 5 HP complete mounted on common MS base frame and foundation as per manufacture design for the pump sets including PCC foundations, MS bolts with nuts etc. all as specified and directed by Engineer-in-charge.
S&F sluice valve,150 mm size, non-rising type with CI wheel, drilled flanged ends, PN-1.00, ISI marked, heavy duty with stainless steel spindle and gun metal working parts including flanged jointing on both ends, jointing material such as rubber / fibre board gasket, suitable size bolts, nuts and twin washers complete all as specified and directed.
S&F sluice valve,100 mm size, non-rising type with CI wheel, drilled flanged ends, PN-1.00, ISI marked, heavy duty with stainless steel spindle and gun metal working parts including flanged jointing on both ends, jointing material such as rubber / fibre board gasket, suitable size bolts, nuts and twin washers complete all as specified and directed.
S&F sluice valve, 80mm size, non-rising type with CI wheel, drilled flanged ends, PN-1.00, ISI marked, heavy duty with stainless steel spindle and gun metal working parts including flanged jointing on both ends, jointing material such as rubber / fibre board gasket, suitable size bolts, nuts and twin washers complete all as specified and directed.
Supply, installation, commissioning and testing of factory made, LT weather proof, CPRI type tested, indoor, cubical compartmental type, conforming to IEC 61439- 1 & 2, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed on wall/floor with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. [a] Busbar Chamber: [i] Copper bus bar capacity 200 Amp for Phase R-Y-B-3 Nos. & neutral - 1 Nos. [b] Incoming: [i] 63 A, 415 V, Ics = Icu = 25 kA, 50 Hz, FP MCCB with adjustable overload settings (0.36- 1 X In) & tr = 0.5 - 16 s, adjustable short-circuit settings (1.5 - 10 X Ir), adjustable earth- fault settings (0.2- 1 X In), current limiting type double break roto active type, instanteneous protection and microprocessor based trip unit- 01 Nos.
[c] Outgoing: [i] 40 A, 415 V, Ics = Icu = 10 kA, 50 Hz, TPN MCB with adjustable overload settings (0.36- 1 X In) & tr = 0.5 - 16 s, adjustable short-circuit settings (1.5 - 10 X Ir), adjustable earth- fault settings (0.2- 1 X In), current limiting type double break roto active type, instanteneous protection and microprocessor based trip unit- 03 Nos. [d] Starter S & F star delta starter 3 phase 415 V 50 Hz, Suitable for Mono Block Pump of 5 HP complete with under voltage and overload protection. Qtn-2 Nos and single phase preventer
M & L for Construction of fly-ash brick masonary valve chamber of size 900 mm X 900 mm X 900 mm (internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc all as specified and directed.
M & L for Construction of fly-ash brick masonary valve chamber of size 900 mm X 900 mm X 600 mm (internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M & L for Construction of fly-ash brick masonary valve chamber of size 450 mm X 450 mm X 600 mm (internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply, installation, testing and commissioning of Electrical Panel of suitable size factory made, CPRI type tested, outdoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 3.15mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50mmx50mmx6mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process) duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in single red colour suitable for 3 Phase 4 wire system 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc complete all as specified and directed Busbar Chamber (a) Copper busbar of rated capacity 250 A, covered with PVC insulated sleeves including insulator, nuts, bolts etc with complete connection-01 Set (3P + N) Incoming (a) 100A, 415 V, Ics=Icu=Icw=25 kA, 50 Hz, FP MCCB with adjustable overload setting (0.36 - x In) & tr = 0.5 - 16 s, adjustable short circuit setting (1.5 - 10 x Ir) adjustable earth fault settings (0.2 - 1 x In) current limiting type double break roto active type, instantaneous protections and microprocessor based trip unit - 01 No
S & F 45 W LED street light having pressure die-cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection, including necessary electrical connections to the fitting with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket having 40mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two caots of synthetic enamel paint over a coat of redoxide primer all as specified and directed as per Bajaj cat No. 169799 BRTFG 45 W LED / Crompton Cat No LSTV-45-CDL-M or technocmoomercial equvivalent out of make as listed as approved by GE..
S & F weather proof PVC junction box of size 250mm x 200mm x 100mm having IP 65 protection for outdoor installation fixed with 4 way backlite cable terminals including 03 Nos of polymide gland with check nut (M-32-3 Nos) fixed on poles with flat aluminium clamps of size 20mm x 3 mm, nuts, bolts washers etc complete all as specified and directed. make Sintex GS-JB-2817 or technocommercial equvivalent of other make as approved by GE.
S & F 15/16 W LED solar street light system, shall include FRP Aluminium housing 15/16 W hi brightness LED light operating voltage 11.1/12.8 volt IP 65 complaint driver efficiency 85% to 90% CRI > 70 CCT 5000 to 6500 K MPPT/OWM base charge controller with hi efficiency LED driver design without dimming function as per IEC standards hi efficiency Mono/poly crystailline solar panel, of make Philips/ Crompton Cat No CSADSPL15CDL or technocommercial equvivalent of make as approved by GE.
S & F galvanised iron medium grade (GI) pole 3" (80 mm) dia 6 mtr height (excluding planting depth) with base plate of 4 mm thick of size 300 mm x 300 mm, for solar street light including painting with aluminium paint over a coat of red oxide primer foundation of pole with PCC 1:3:6 using 20 mm graded stone aggregate of size 450 mm x 450mm x 1000 mm deep complete inlcuding excavation and earthwork, PCC etc. all as specified and directed.
S & F post top lantern light fitting 1 x 45 watt LED type black ABS plasting spigot spun aluminium canopy with opal diffuser and accessories 1 x 45 w complete all as specified and directed of make 112362 BGCP 45 W LED WW of Bajaj / Crompton Cat No LPTO-45-CDL or technocommercial equvivalent of make as approved by GE.
S & F 1 x 9 Watt LED inverted pyramid tripod type LED bollard with soft 360 degree light garden light of make 11282BGBOL 605 9W of Bajaj / Crompton Cat No LBLA1-10-CDL or technocommercial equvivalent of make as approved by GE.
S&F 15 Mtr High, galvanised high mast made out of heavy duty MS pipe section reucing from bottom to top 15mm thick bottom plate fixing arrangement with 20mm dia foundation bolts grouted in PCC foundation including necessary civil work etc complete with and inlcuding fixing arrangement for 9 lantern LED 80 watt each symmetrically fixed along with their control gear and having two point suspension system with steel wire rope of 6 mm dia & double drum winch (All as per OEM recommendations) comprising of followings:- (a) Fabricate, supply, install, test and commissioning of LT out door total enclosed panel board of size 0.75 x 0.50 x 0.30 metre approx totally enclosed made out of 3mm thick CRCA sheet, dust and vermin proof with front opening 440V,3 Phase, 4 wire having 200 Amps capacity aluminium bus bar insulated with sleeves, incoming MCCB TPN 63 Amps 440 Volts,25 KA 01 No and copper wiring with multistranded cable including timer switch electronic type 01 No with necessary MCBs SP 10 Amps 09 Nos, contractors etc, cable glands, lugs and two coats of synthetic enamel paint over a coat of red oxide primer and making necessary pedestal 300mm height from floor level with PCC work including following complete all as specified & directed.
(a) Fabricate , supply , install , test and commessioning of LT outdoor total enclosed lLt panel board of size 0.75 x 0.50 x 0.30 meter approx tottaly enclosed made out of 3mm thick CRCA sheet , dust and vermin proof with front opening 440v,3 phase, 4 wire having 200 Amps capaciy aluminium bus bar insulated with sleeves , incoming MCCB TPN 63 Amps 440 volt 25KA 01 No and copper wiring with multistaranded cable including timer switch electronic type 01No with nessary MCBs SP20 Amps 09Nos contractors etc, cable glands . lugs and two coats of synthetic enamel paint over a coat of red oxide primer and making necesssary pedastal 300mm height from floor level with PCC work. (b) Provision of wiring from panel to light fitting with single/multi core 4 SQMM coper conductor cable drawn through M rigid/flexible conduit with necessary fitting etc. (c) Provision of single point air termination rod and necessary fitment required for protection against lightening protection. (Earthing shall be measured and paid separately) (d) Provision of motorised 1ith mechanical system for hosting and lowering of lights carriage for repairs. (e) Provn of Aviation Light indicator all as specified and directed by Engr-in-Charge
M & L for pressure Die cast housing with IP 65 protection efficient high output emitter LED for better distribution LED Flood light luminaries 80 Watt of make Crompton Cat No LFL-80-CDL/60-M or technocommercial equvivalent of make as approved by GE.
Supply, installation, testing and commissioning of 630 A, 11 KV 50 Hz, 3 Phase dead front, floor-standing fully compartmentalized metal clad dust, dump and vermin proof indoor HT switchboard conforming to IEC 62271-200, with provision for bolting to the floor, suitable for severe tropical climate conditions and fully complying with climatic aging tests as per IEC 60932 having separately earthed IP5X rates HV and busbar compartments and IP4X r+F618 LV compartment made of CRCA sheet steel, multi panel shunt trip, indoor type, motor operated spring closing vacuum circuit breaker (VCB) conforming to IEC 62271-100, having SCADA compatible facilities and complete with all accessories, overload & earth fault protection for rupturing capacity of 250 MVA as specified and directed. The HT switchboard shall confroming the following technical specifictaions :-
(g) Control supply for closing and tripping shall be 110/220 V DC through an external battery source, 230 V, 50 Hz 1 Ph AC supply shall also be availabel for the operation of spring charging motor and cubicle space heater. Wattage rating of closing and tripping coils shall be within 250 W, Auxiliary supply shall be suitably distributed alongwith switchgear in loop in loop out fashion. (h) All the secondary wiring in the panel shall have high quality PVC insulation and the same shall have conductor size of not less than 1.5 Sqmm of copper. (j) Compact CIO 2S Power Measurement Device (PMD) conforming to IEC 61557-12, with battery backed real time clock, 4th CT for neutral and ground current measurement, dual ethernet ports for daisy chain communication, internal webpage, upto 63rd harmonic (magnitude & direction) two relay outputs for circuit breaker monitoring and control, multi tarrif schedule, peak demand with time stamping D/T for current and power. Notes : (i) The bidder shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADS of the windings with details of insulation of each point and core construction etc for approval of the accepting officer. (ii) The bidder shall intimate the Accepting Officer for the routine tests in accordance with IEC-62271-200 & IEC 62271-100 in the OEM factory in presence of a representative nominated by the Accepting Officer before despatch.
Supply, installation, testing and commissioning of silent DG Set, conforming to IS: 10002- 1981, complete with Diesel Engine of suitable BHP & AC Brushless SPDP alternator, conforming to IS: 13364- 1992, mounted on a common base frame & coupled through a flexible coupling or close coupled and AMF Panel complete with platform, control panel having meters, sound-proof canopy, etc. of capacity 500 kVA complete of make Kirloskar, Crompton Greaves, Cummins, Sudhir or techno-commercial equvivalent make as approved by GE, all as specified as follows and as directed. [a] Engine: 4/6 cylinder, in-line, 4 stroke, radiator cooled engine, well designed air handling system with dry type, heavy duty, replaceable paper element air cleaner with restriction indicator, air to air aftercooling, optimised turbocharger for increased altitude,Inline fuel pump with A1 class mechanical governing, spin on fuel filter, standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature, full flow spin on lube oil filter, electrical starter motor with soft start engagement feature, battery charging alternator with 1 x 12 V DC battery. [b] Alternator: Brushless type, screen protected, revolving field, self-excited alternator, conforming to IS/IEC 60034-1 3-phase reconnectable winding with 12 terminals brought out for connection, dedicated winding specially designed for single operation, impregnation on all wound components for better mechanical strength [c] Control Panel: Manufactured with 14/16 gauge CRCA sheet and powder coated for weather-proof and long lasting finish. The control panel consists of the following parts: [i] Controller: Aluminium bus bars with suitable capacity with incoming/outgoing terminals
[ii] Indicating lamps for ‘Load ON’ and ‘Set Running’ [iii] Instrument fuses duly wired and ferruled [iv] MCCB of suitable rating with overload and short circuit protections [d] Microprocessor based generator set monitoring and control system including an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration and diagnostics, LED backlit LCD display with tactile feel soft-switches & generator set status LED lamps, remote START-STOP [e] Engine Metering: Oil pressure, engine temperature, starting battery voltage, engine running hours [f] AC Alternator Metering: L-L voltage and L-N voltage, current (phase and total), kVA (phase and total) and frequency [g] Engine Protection: Low lube oil pressure, high/low coolant temperature, battery over/under/weak volts, fail to crank/start, sensor failure, cranking lockout, low fuel level [h] AC Alternator Protection: Over/under voltage, over/under frequency, loss of AC sensing.
[i] Data Logging: Engine hours, control hours and upto 5 recent fault codes [j] Configurable glow plug control [k] 12 V DC operation [l] Silencer: Critical grade silencer suitably optimized to meet stringent noise emission standards laid down by MoEF / CPCB [m] Mounting Arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. [n] Base frame with integral fuel tank is provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as specified and directed. (Note:- For the purpose of payment only punned thickness will be measured. )
FIRE FIGHTING, FIRE DETECTION AND ALARM
Supply, installation, testing and commissioning of analogue addressable four loop "Main Fire Alarm Control Panel" expandable upto ten loops with 99 detectors & modules & upto 200 detectors and modules per each loop, LCD display & QWERTY numeric keypad, power supply & 24 hrs battery backup suitable for loop length 1.5 Km per loop complete all as specified and directed
Supply, installation, testing and commissioning of networkable active repeater panel with 40 character LCD display connected peer to peer with "Main Fire Alarm Control Panel" with accept reset functions complete all as specified and directed. Make NCA-2 or technocommercial equvivalent as approved by GE.
Supply, installation, testing and commissioining of addressable type indoor Sounder cum Flasher with addressble control module and box consisting 8 different tone variants complete all as specified and directed.
S & F 5 Amp, 24 DC power supply for sounder cum flasher and beam deector with enclosure complete all as specified and directed
Supply, installation testing and commisioning of control relay module with enclosure/junction box complete for third party integration complete all as specified and directed.
Supply, installation, testing and commissioining of directional sounder with sound frequency 20 kHz bear exit points with required control module complete all as specified and directed. Make Notifier-PF-24V-FCM-1 or technocommercial equvivalent as approved by GE.
M & L for copper conductor, XLPE insulated armoured cables, conforming to IS BS EN 60228, having annealed copper conductor, PVC inner sheath, single armouring of galvanised round steel wire, one layer of PETP tape wrapping, collective screen of PETP/Aluminium tape over tinned copper drain wire, RED in colour, including clamping, termination and ferruling complete all as specified and directed. Male: - RR Kabel, Havells, polycab or technocommercial equvivalanet as approved by GE.
2 Core 1.5 Sqmm
2 Core 2.50 Sq mm
Supply, installation, testing and commissioining of diesel engine driven horizontal end suction & top discharge, backpull out type centrifugal pump, conforming to IS 12469-2011, with CI casing, bronze impeller and stainless steel shaft, mechanical seal etc mounted on heavy duty bearing, couplings, zero access type coupling guard etc capable to deliver 2850 LPM at 70 m head. The pump shall be coupled to a water cooled radiator, diesel engine of suitable BHP & speed, two sets of batteries of adequate rating with suitable for battery leads & stand, battery charger, residential silencer, diesel tank of capacity adequate for 6 hours of operation and fitted with level and exhaust silencer. The complete set shall be mounted on common base frame including foundation as per manufacturer's recommendation complete all as specified and directed.
Supply, installation, testing and commissioining of electric motor driven horizontal end suction & top discharge, backpull out type centrifugal pump, conforming to IS 12469-2011, with CI casing, bronze impeller and stainless steel shaft, mechanical seal etc mounted on heavy duty bearing, couplings, zero access type coupling guard etc capable to deliver 2280 LPM at 70 m head coupled with a spacer coupling to a 2 pole TEFC type squirrel cage induction motor of suitable HP with IP 55 protection of enclosure at 2900 RPM speed, efficiency not less than 55%, suitable for operation on 415 V + 10%, 3 Phase, 50 Hz AC supply, horizontal foot mounted type with class F insulation conforming to IS 12615-2018 with coupling gyard, foundation as per manufacturer's recommendation complete all as specified and directed.
Supply, installation, testing and commissioining of electric motor driven horizontal end suction & top discharge, backpull out type centrifugal pump, conforming to IS 12469-2011, with CI casing, bronze impeller and stainless steel shaft, mechanical seal to deliver 450 LPM at 36 m head coupled with a spacer coupling to a 2 pole ETFC type squirrel cage induction motor of suitable HP with IP 55 protection of enclosure at 2900 RPM speed, efficiency not less than 55%, suitable for operation on 415 V + 10%, 3 Phase, 50 Hz AC supply, horizontal foot mounted type with class F insulation conforming to IS 12615-2018 with coupling gyard, foundation as per manufacturer's recommendation complete all as specified and directed.
Supply, installation, testing and commissioining of electric motor driven horizontal end suction & top discharge, backpull out type centrifugal pump, conforming to IS 12469-2011, with CI casing, bronze impeller and stainless steel shaft, mechanical seal to deliver 180 LPM at 70 m head coupled with a spacer coupling to a 2 pole TEFC type squirrel cage induction motor of suitable HP with IP 55 protection of enclosure at 2900 RPM speed, efficiency not less than 55%, suitable for operation on 415 V + 10%, 3 Phase, 50 Hz AC supply, horizontal foot mounted type with class F insulation conforming to IS 12615-2018 with coupling gyard, foundation as per manufacturer's recommendation complete all as specified and directed
Supply, installation, testing and commissioining of factory made, CPRI type tested indoor, cubical compartmental type "Motor Control Center" (MCC) of suitable size conforming to IEC 61641, having both sides openable with hinged double doors & loocking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process) duly fied in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steels heet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3 Phase 4 wire system, 500 V grade with necessary length & size, incluidng fixing lugs, bolts, screws etc complete all as specified as follows and as directed
S & F for ISI marked MS ERW pipes 100 mm NB conforming to IS 1239 (Part 1 & 2) with all accessories like all fittings including tees, elbows,, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer, including supporting/ fixing the pipe in excavated trenches with painting of one coat primer and 2 or more coats of synthetic enamel paint of and wrapping of 4mm thick protection coating by thermo fusion process complete all as specified and directed Notes:- the rates shall be inclusive of following: - (a) Standard MS fittings with welded joint shall be used (b) All hangers, clamps, brackets etc shall be of galvanised iron of suitable size as directed. (c) Welding of any kind on the galvanised support/ hanger shall not be permitted. (d) Pipes of size more than 50mm NB shall be butt welded with fittings of equal or higher thickness whereas pipes below 50mm NB size shall be socket welded
Supply, installation, testing and commissoining of following PN 1.6 rated CI sluice valve conforming to IS 14846-2000 with SS spindle conforming to IS 1538-1993 and necessary accessories for suction side of fire pumps all complete as specified and directed.
Supply, installation, testing and commissoining of following PN 1.6 rated CI swing check type reflux (non return) valve, conforming to IS 5312 (Part 1)-2004 with flange drilling standard end connection conforming to IS 1538-1993 and necessary accessories all complete as specified and directed.
Supply, installation, testing and commissoining of pressure switch suitable for pressure range 0-14 bar having die cast aluminium construction and SS sensing element with ball valve, fittings viz, unions, collars, reducers etc for fire pump sets complete all as specified and directed
Supply, installation, testing and commissoining of bourdon pressure gauge suitable for 0-21 kg pressure range with 8" dial, die cast aluminium body, including ball valve, nipple, socket etc for delivery lines of fire pumpsets near the flow switches all complete as specified and directed
M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized iron strip earth 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete as detailed below and all as directed.
NOTES :- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
S & F non percolating rubber reinforced lined RRL hose type A 15m long fire hose of 63mm NB size, conforming to IS 636-1988, rated for bursting pressure of 35.7 kg/cm complete with gunmetal male & female coupling conforming to IS 903-1993, bound and rivetted to the hose pipe with copper rivets and 1.5mm copper wire complete as specified and directed
S & F swinging type 36m long First Aid Hose Reel, conforming to IS 884-1969 having 19mm NB thermoplastic reinforced hose reel tubing, conforming to IS 12585-1988, 25mm NB ball valve, stop cock, terminating with gunmetl coupling & nozzle of 6mm NB outlet with shut off valve, conforming to IS 8090-1976 complete with MS socket for tap off, red colour drum, brackets (including painting) for fixing on wall with anchor fastner, bolts, nuts etc complete all as specified and directed
Supply, installation, testing and commissioning of 4 way fire brigade inlet connection, conforming to IS 5290-1993 with four 63mm NB inbuilt gunmetal non return valves, four 63mm NB instanteneous coupling arranged on 150mm NB pipe manifold and connected to fire hydrant ring main and fire hydrant wet riser pipe all complete as specified and directed
Supply, installation, testing and commissioning of 2 way fire brigade draw off connection with two 63mm NB inbuilt gunmetal non return valves instanteneous coupling type arranged on 100mm NB pipe manifold and connected to wet riser main as well as to fire water tank incluidng CI butterfly valve, CI non return valve and MS cabinet with mounting supports etc all complete as specified and directed
S & F fire extinguisher dry chemical powder (ABC) type 6 Kg capacity IS 15683 all complete as specified and directed. Make ceasefire, or technocommercial equvivalent make of Minimax or SAFEX as approved by GE.
S & F fire extinguisher CO2 type 4 Kg capacity squeeze grip operative light weight IS 15683 all complete as specified and directed. Make ceasefire, or technocommercial equvivalent make of Minimax or SAFEX as approved by GE.
M & L for supply and fixing of 3 Watt LED EXIT SIGNATE (GREEN/RED) with inbuilt battery backup for 2 hours and the "EXIT" Word/Text must be large and clearly visible from long distance including making connections complete all as specified and directed as per Make Instapower.
Providing and fixing of ISI marked Auto Glow Vinyl Laminated Exit/In Signs complete all as specified and directed
Supply, installation, testing and commissioning of MS air cushion tank conforming to IS 4736-1968 on top of each riser fabricated from 6mm thick MS plate 250mm x 1000 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MS plate with Air release valve with stop cock, flanged inlet connection and frain arrangement with 25mm NB valve, pressure gauge with gun metal stop cock complete all as specified and directed.
M & L for construction of Fly Ash Brick masonry valve chamber of internal size 1200 mm x 900mm x 1200mm (internal diamensions) with PCC foundation 1:4:8 type D2 using 40mm graded stone aggregate, 150mm thick and 150mm wide offsets around over 100mm thick hardcore, 230mm thick Fly Ash Brick masonry walls built in CM 1:6, 100mm thick PCC 1:2:4 type B1 coping finished even and smooth, rendering 10mm thick in CM 1:6 finished even and smooth without using extra cement internally incluidng top of floor incluidng excavation earth work in any type of strata, 6mm thick MS sheet cover fixed on 25mm x 25mm x 6mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surpluys soil to a distance not exceeding 50mm etc complete all as specified and directed
S & F electric motor siren conforming to IS 1941 suitable for three phase 415 V supply with motor not exceeding 3.75 KW power and able to deliver 143 DB noise level complete all as specified.
SUMMER APPLIANCES: S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilised at 230 V with accuracy of + 2.5% and capacity 2 KVA
STAGE LIGHTING
SITC of 200W LED Focusing Imaging Light Power Supply AC100-240V/ 50-60HZ Light Source 56 (3030) or (3535) 3-5W white LED light source Light Source Power 200W Total Power 240W Color Temperature 3200K or 5600K Color Rendering Index 92% or more Dimming Mode DMX signal dimming or manual button dimming Control Channel 1 channel Focusing Mode manual knob sliding focus Light Angle adjustable from 10-20° Working Environment 0°- 40°C (32°-104°F) Protection Level IP20 - OEM aurtorization must submitted at the time of Bid / supplye Approved Make - Fidelity Lightings (Cat Part FL-LED F0-05 ) or Simlier in Canara Lightings / Stage Craft
SITC of 200W LED Spotlight (Color Temperature Adjustable) Power Supply AC100~240V, 50/ 60Hz Power 220W Light Source Highly indicated COB LED lamp beads Color Rendering Index Ra>94 Light Source Life 100,000 hours Color Temperature 3000K-6000K adjustable Control Panel LCD display+four buttons Beam Angle 15-60 degree Manual zoom Dimming 0-100% linear dimming Heat Dissipation Method copper tube radiator Channel Mode /4CH Control Mode DMX512 control/ manual contro Working Temperature -25°C ~ +45°C Housing Material aluminum alloy OEM aurtorization must submitted at the time of Bid / supplye Approved Make - Fidelity Lightings (Cat Part FL-LED B0-02 ) Canara Lightings / Stage Craft
SITC Of 200W Color Temperature Adjustable LED Flat Soft Light Power Supply AC100~240V, 50/ 60Hz Power 200W Light Source High index LED array Color Rendering Index index: Ra>95 Light Source Life 100000 hours Color Temperature 3000-6000K color temperature is adjustable Control Panel LCD display+four buttons Beam Angle 120 degree Dimming 0-100% linear dimming Cooling Method no fan cooling naturally Channel Mode /4CH Control Mode DMX512 control/ manual control Protection Level -25°C ~ +35°C Housing Material Aluminum alloy OEM aurtorization must submitted at the time of Bid / supplye Approved Make - Fidelity Lightings (Cat Part FL-LED D0-02 ) Canara Lightings / Stage Craft
SITC of L 18*10W LED Wall Washing Light Rated Voltage AC110V~240V, 50~60Hz 200VA Light Source 18×10W LED(4IN1)/Average life 50000H Color Yemperature Correction 3200K~7200K Linear adjustment Lens Sngle 25° Illumination Dngle adjustable angle Strobe Independent electronic strobe 1-25Hz, random strobe, pulse strobe, synchronous and asynchronous strobe, monochrome, mixed color temperature strobe Color Mixing RGBW (red, green, blue, white) linear color mixing, 16.7 million colors (0-100% saturation adjustable), built-in megafunction Electronic Dimming Electronic dimming: 0-100% independent electronic linear dimming, camera video is true without flicker, master-slave auto-synchronization function, console normally controls self-propelled Lamp Connection three-core signal line IN/OUT power line IN/OUT Protection Grade electrical class II, fire protection V-1, protection IP65 OEM aurtorization must submitted at the time of Bid / supplye Approved Make - Fidelity Lightings (Cat Part FL-FGB1-01 ) Canara Lightings / Stage Craft
SITC of 200W PAR Light Light Source Super bright LED 200W two-color US imported chips. The color temperature of a 100W warm white LED lamp bead is 3200K, The color temperature of a 100W white LED lamp bead is 6500K/ Average life: 50000H Color Temperature 3200K~7200K adjustment Illumination Angle 60 angle Control Mode voice control, self-drive, master-slave, DMX Channel 6 channel /3 channel Protection Grade electrical class II, fire protection V-1, protection IP20 Voice Sensitivity 65-130dB Working Environment -20° C ~ 40° C OEM aurtorization must submitted at the time of Bid / supplye Approved Make - Fidelity Lightings (Cat Part FL-FGA0-07 ) or Similer in Canara Lightings / Stage Craft
SITC of 120*3W LED wash Light Color Temperature Correction 3200K~7200KLinear adjustment Lens Angle 25° (15°, 45°Optional))Illumination angle: adjustable angle Illumination Angle adjustable angle Strobe Independent electronic strobe 1-25Hz, random strobe, pulse strobe, synchronous and asynchronous strobe, monochrome, mixed color temperature strobe Electronic Dimming 0-100% independent electronic linear dimming, camera video is true without flicker, master-slave auto-synchronization function, console normally controls self-propelled permanent synchronization OEM aurtorization must submitted at the time of Bid / supplye Approved Make Fidelity (Cat part -FL-LED-W1203) or Similer in Canara / Stage Craft
SITC of Digital Dimmer 12*4kw Power Supply uency 50Hz ±5% Rated Power 12 channels × 4KW; can be applied to any load.Overload and short circuit double protection high breaking air switch. A.B.C three-phase work indicator. Set two-pin and three-pin universal socket for convenient use, terminal input, single 40A bakelite plug output OEM aurtorization must submitted at the time of Bid / supplye Approved Make - Fidelity Lightings (Cat Part FL-DF0-124) Canara Lightings / Stage Craft Fidelity Lightings (Cat Part FL-FGA0-07 ) Canara Lightings / Stage Craft
SITC of high Quality DMX Cable Jacket PVC, ø 8.80 mm, marine blue Shield No. 1 Bare copper wires (0.10 mm), 100% coverage Shield No. 2 Bare copper wires (0.10 mm), 100% coverage Layer Polyester nonwoven thermally bonded, both sides alum. coated Separation Filler material viscose Conductor shield layer Polyester nonwoven thermally bonded, both sides alum. coated Cond. copper shield Bare copper wires (0.10 mm), 100% coverage Isolation Cellular PE, ø 2.00 mm, 4 different colors Conductor Stranded bare LCOF copper wires, 64 x 0.10 mm (4x) (0.50 mm²) - Approved Make Gothem / Fidelity / Klotz
Interconnect for Lighting Complite as on required on site
M & L MS work for fabrication for frame work using MS sections ,MS tubes, Mounting Hardwares C clamps, etc.of any description type and size as per OEM recommondations and standards, including bending, cutting, welding, nuts, bolts, washers of required size including painting two coats of synthetic enamel paint over priming coat of red oxide complete all as sepcified and directed for stage lighting brackets etc.
SITC of Certified to IEC/EN 61643-1 Branch Circuit surge protection and power conditioning For audio / Video / Stage Lightings panel.is built with a professional-grade NEMA magnetic shielding steel enclosure eliminate surge energy up to 6,000 volts without producing harmful side effects such as earth contamination or common-mode disturbances. Nominal line to neutral voltage U0 (V) 240V Max.Cont. Operating Voltage Uc (V) 240V 260VAC Voltage protective level Up (V) 1KV Max. shorted current. (Isc) 3KA Open circuit voltage (Uoc) 6KV TOV characteristic (UT) TOV withstand , tT = 5s, UT=335V; Applicable Power Supply System TN TT IT Number of ports Two Voltage regulation ≤ 1% Operation temperature and humidity -40 - +35°C, 30-90% Approved Make - Surge X / Furmann/ Legrand
AIR CONDITIONING
WATER-COOLED SCROLL TYPE CHILLER UNIT : -Supply, installation, testing and commissioning of factory designed, pre-fabricated and floor-mounted, water vapour compression, scroll type water cooled chiller machine having nominal capacity not less than 85 TR complete with semi-hermatic scroll compressors with independent refrigerant circuits, water-cooled S/T type condenser, S/T. The quoted price shall be inclusive of a unit mounted automatic star/delta starter (to ensure that the starting current does not exceed twice the full load current), variable frequency drive (VFD) configured in accordance with site parameters, victaulic coupling and system integrator capable of giving industry standard (modbus/BACnet) output to BMS for critical parameters.. mapping shall be required for all critical points displayed on the chiller control panel. The chiller shall be BMS compatible and shall have RS485/RS232 serial communication protocol; the motor shall be suitable for 3- Phase, 415 V ± 10%, 50 Hz AC electric supply; electric panel shall have an IP 54 rating. horizontal flooded type evaporator with carbon steel shell and seamless copper tubes with elastomeric insulation, common base frame, interconnected copper refrigerant piping and wiring, vibration isolators, gauge panel, automatic safety controls, flow switch at evaporator and condenser and ozone friendly, CFC-free refrigerant all complete as specified and directed.
Necessary civil work viz. foundation for placement of chillers shall be covered in the scope of work. The chiller shall be as per the approved particular technical specifications and shall meet the following design criteria: [a] Local ambient temperature: 112 °F [b] Chilled water leaving temperature: 44 ⁰F [c] Chilled water entering temperature: 54 ⁰F [d] Evaporator fouling factor: 0.00025 ⁰Fft²hr/Btu [e] IKW/TR: Not exceeding 0.85 [f] Refrigerant (Ozone friendly type): R 304 /R-134 a [g] Minimum COP required 4.7 [h] Flow Rate: chilled water- 2.46 USgpm/TR; condenser water- 4.0 USgpm/TR
CHILLED WATER CIRCULATION PUMP (1W + 1 S) Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type pump suitable for 29 LPS water flow and 14 MWC head along with elastomeric insulation, having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, elastomeric insulation, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete all as specified and directed. Note: -Necessary civil work viz foundation for placement of pump, mounting of star/delta starter panel and pump accesories shall be covered in the scope of work.
FRP INDUCED DRAUGHT COOLING TOWER Supply, installation, testing and commissioning of FRP rectanguler shape, vertical, induced draught counter flow cooling tower suitable for 100 TR capacity having flow rate of 4.0 USgpm/TR with uniform water distribution and optimal heat transfer, having tough fiberglass reinforced plastic (FRP) casing of sufficient structural strength to withstand vibrations and wind velocity upto 60 m/s, FRP basin, rigid honeycomb type PVC fill of suitable thickness, SS sprinklers and non-clogging sprinkler pipes, FRP drift eliminator, energy efficient induced draught axial type fans with factory set and dynamically balanced blades pitch, TEFC squirrel cage high efficiency induction motor with IP 65 protection, inlet, outlet, drain and over-flow nozzle connections, etc. suitable for 3- Phase, 415 ± 10% V, 50 Hz AC electric supply complete all as specified and directed. Necessary civil work viz. foundation, supporting structure, etc. for placement of cooling tower, mounting of star/delta starter panel shall be covered in the scope of work.
CONDENSER WATER PUMP (1W + 1S) : -Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type pump suitable for 43.5 LPS water flow and 10 MWC,1400 RPM head having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete all as specified and directed. Necessary civil work viz. foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be covered in the scope of work.
HVAC ELECTRIC PANEL: - Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical compartmental type "HVAC Panel" of suitable size, conforming to IEC 61439-1 &2, IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified. The HVAC Panel shall comprise of the following:
[iI] 160 A, 415 V, Ics = Icu = 36 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [chiller] [iii] 63 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 04 Nos. [for AHUs & PAN type humidifier] [iii] 32 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 08 Nos. [2 Nos. for chilled water circulation pumps, 2 Nos. for condenser water circulation pumps, 2 Nos. for cooling towers, 2 hot water circulation pumps] [v] 32 A, 230 V, 50 Hz, SPN MCB (C- curve)- 01 Nos. [for AC Plant Room] [iv] LED phase indicators (Red, Yellow, Blue)- 16 Set [v] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 16 Nos. NOTE: [i] The panel shall be completely Ethernet communication ready to communicate with Energy Management System & shall be Web based application in-built. [iii] The Panel shall be with wireless energy sensor on incomer and outgoing feeders for monitoring (V, I, P, PF, Energy), voltage loss alarm, Unbalance in phases. Same shall be communicated through Ethernet communication gateway to centralised Energy Monitoring System.
PAN-TYPE HUMIDIFIER Supply, installation, testing and commissioning of PAN-type humidifier suitable for 20 l/h evaporation rate having SS-304 sheet welded construction with unitized stainless steel reservoir divided into two chambers from inside having 25 mm thick fiberglass insulation cladded with aluminum foil, snap-acting humidistat, support legs for free-standing or wall hanging brackets for wall-mounting, factory mounted & wired humidifier control cabinet, steam outlet nozzle, water make-up, drain, over-flow, quick fill connections, immersion heaters made of copper or stainless steel, terminal blocks suitable for field power and control wiring and safety thermostat complete all as specified and directed.
HOT WATER GENERATOR Supply, installation, testing and commissioning of SS 304 shell type vertical electric hot water generator suitable for 110 kW heat output for hot water output at 105º F (40.55º C), tested for 350 psig pressure, having resin insulation bonded with fiber glasswool along with aluminium cladding, thermostat for individual step, digital thermometer for inlet & outlet pipes, pressure gauge with ball valve for inlet & outlet pipes, SCR based stepless linear controller, float switch, audio/visual alarm for low water level, audio/visual alarm for high temperature, pressure relief valve, door switch, safety thermostat, etc.. complete all as specified and directed.
CENTRIFUGAL MONOBLOCK PUMP FOR HOT WATER GENERATOR Supply, installation, testing and commissioning of centrifugal monoblock pump for pumping hot water from hot water generator to heating coil in AHU with energy efficient motor conforming to IS 12615. The pump shall be suitable for the given duty point. Each pump shall be of 100% capacity. (Out of two pumps, one shall be working and one shall be standby.) The pumps shall be insulated with 25 mm thick closed cell elastomeric insulation useful upto 220 ˚F with wrapped water-proof fabric cloth all as specified and directed. [i] Water Quantity (discharge): 1345 LPM [ii] Static Head: 12 m [iii] RPM of motor: 2900 [iv] Impeller: Bronze [v] Shaft: High Tensile Steel [vi] Seal: Mechanical [vii] Motor: Suitable HP, Squirrel Cage SPDF having Class B Insulation [viii] Starter: Star/Delta or DOL [ix] Base Frame: MS Fabricated [x] Foundation: RCC / PCC foundation as per OEM recommendation
EXPANSION TANK FOR CHILLED WATER MAKE-UP S & F SS- 304 closed expansion tank of 500 litres capacity and pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge, insulated with 50 mm thick elastomeric insulation and cladded with 26 gauge aluminium complete all as specified and directed.
HDPE MAKE-UP WATER TANK FOR COOLING TOWER S & F multilayered HDPE make-up water tank of 20000 liter capacity made up of 100% virgin material, having 100% UV stabilized white outer layer, threaded lid, extra insert lid for protection against algae formation complete with inter-connection piping and non-return valve etc. complete all as specified and directed.
EXPANSION TANK FOR HOT WATER MAKE-UP S & F SS- 304 closed expansion tank of 50 litre capacity and pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge, insulated with 50 mm thick elastomeric insulation and cladded with 26 gauge aluminium complete all as specified and directed.
POT STRAINER: - Supply, installation, testing and commissioning of PN 1.6 rated POT strainer, 150 mm NB tested as per BS 6755 (Part- I), suitable high capacity flow throughout full size inlet/outlet, having CI body & strainer bonnet, stainless steel perforated filter screen, black rubber body/bonnet gasket, SS- 410 ball valve and flange drilling standard end connection, etc. complete all as specified and directed.Make: Sant & Sbm Or Zoloto
Y-STRAINER:- Supply, installation, testing & commissioning of Y-type strainer of 150 mm NB, with CI / MS body, bolted cover, flanged ends, basket of brass / bronze / SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection, etc. complete all as specified and directed.
MANUAL BALANCING VALVE Supply, installation, testing & commissioning of manual balancing valve suitable for PN 1.6 pressure rating, having built-in measuring facility, with CI body, flanged connection, EPDM coated disc with long pitch, etc. conforming to BS 7350 for condenser water circulation complete all as specified.
CHILLED WATER PIPING MS ERW CLASS- C PIPE WITH INSULATION: -Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding complete as specified. NOTE: [i] The pipe size 150 mm NB & below shall be MS 'C' class as per IS 1239 (Part- 1): 2004 & IS 1239 (Part- 2): 2011. [ii] The pipe size above 150 mm NB shall be welded black steel pipe heavy class as per IS 3589: 2001. [iii] Minimum thickness of MS sheet for pipe size above 150 mm NB and up to 350 mm NB shall be 6.35 mm and it shall be 7 mm for pipe size 400 mm NB and above.
Y-STRAINER Supply, installation, testing & commissioning of Y-type strainer with CI / MS body, bolted cover, flanged ends, basket of brass/ bronze / SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding and accessories complete all as specified and directed.
BUTTERFLY VALVE: - Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve designed, manufactured and tested as per IS 13095: 1991, suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding and accessories complete all as specified and directed.
NON-RETURN VALVE (NRV): -Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding and accessories complete all as specified and directed.
MANUAL BALANCING VALVE Supply, installation, testing & commissioning of manual balancing valve suitable for PN 1.6 pressure rating, having built-in measuring facility, with CI body, flanged connection, EPDM coated disc with long pitch, etc. conforming to BS 7350 for condenser water circulation duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding and accessories complete all as specified and directed.
3-WAY TEMPERATURE CONTROL VALVE Supply, installation, testing and commissioning of electronic, self-balancing, pressure independent type dynamic balancing valve of following size with integrated 3-way modualating control valves in a single body duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding and accessories complete all as specified and directed. NOTE: [i] The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. [ii] Maximum close off pressure shall not be less than 6 bar for upto 50 mm valves and not be less than 7 bar for 65 mm & above. [iii] Valves should have pressure rating 25 bar minimum.
S & F of CL 150 # rated 25 mm NB ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories complete all as specified and directed. Make: Sant & SBM Or Zoloto
Supply, installation, testing and commissioning of automatic air-vent valve with 19 mm end connections with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide cap etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 115° C respectively, installed on all high points in the water piping system to automatically remove the trapped air complete all as specified and directed. Make: Sant cat part No. AV or technocommercial equvivalent of Sbm Or Zoloto
TEMPERATURE GAUGE Supply, installation, testing and commissioning of glycerin filled bimetallic thermometer in compliance to EN 13190, having standard range 0 °C to 60 °C up to 400 °C, IP 67 protection, bimetal coil sensing element, accuracy class 1 as per EN 13190, stainless steel casing, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 stem and connection, aluminum dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), toughened glass window, neoprene filling plug and gasket complete with accessories, etc. complete all as specified and directed. Temperature gauge of 150 mm dial size for temperature range 0° C to 100° C
Supply, installation, testing and commissioning of glycerin filled pressure gauge Pressure gauge of 100 mm dial size for pressure range 0 psi to 200 psi in compliance to EN837-1, having standard range 15 to 0 psi and 16 psi to 10000 psi, IP 67 protection, accuracy class ±1.6% of FS, stainless steel casing and TIG argon welded socket to case, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 bourdon, socket, SS dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), polycarbonate glass window, neoprene blow off disc and filling plug, silicon gasket complete with accessories, etc. complete all as specified and directed. Make:Baumer or techno commercial equvivalent
DOUBLE SKIN AIR HANDLING UNIT: -Supply, installation, testing and commissioning of double-skin type horizontal, floor-mounted, top/side discharge air handling units 30000 CFM, 3 " WG static pressure, having corrosion resistant extruded aluminum hollow profile with thermal break, 16 gauge galvanized steel channel base frame, 43 mm thick double skin panel with pressure injected CFC & HCFC free PUF having 'k' value of 0.02 W/°C/m & density 40 kg/m³ pre-coated, pre-plasticized, galvanized outer and inner skin 0.60 mm thick, air-tight casing using gaskets and self-adhesive tapes, AMCA certified energy efficient fans with double inlet, double width forward or backward curved impellers for high static pressure mounted on aluminum extruded siderail base frame, combination of 6 rows deep chilled water coils with anti-corrosion aluminum fins, combination of 2 rows deep hot water coils with anti-corrosion aluminum fins PVC/naylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan, 10 micron pre-filters, inspection windows/doors, mixing box and supply/return/fresh air dampers complete all as specified and directed. The rates shall of AHU shall be including and comprise of the following: -
[a] Suitable DIDW fan with AMCA certified blower having outlet velocity not exceeding 9.2 m/s [b] 4 Pole, TEFC, high efficiency, squirrel cage induction motor having BHP rating 20% higher than the peak capacity, suitable for 415 V ±10%, 50 Hz, 3-Phase AC power supply [c] V-belt drive assembly with pulleys, belt, guard, etc., double canvass connections with zip to discharge duct/plenum, etc. [d] 50 mm thick, washable HDPE, 90% down 10 micron pre-filters, filters, fixing framework, hinge type access doors, etc. [e] 6 row deep chilled water coil section with copper fins and copper tube tested on 21 kg/cm² with SS sandwiched drain tray, etc. [f] 2 row deep heating coil section with copper fins and copper tube tested on 21 kg/cm² with SS sandwiched drain tray, etc. [g] AHU panel made out of 2.00 mm thick mild steel CRCA sheet, duly powder coated, in compartamentalised construction with incomer and outgoing feeders for AHU motor, 3-way valve actuator motor, fire damper actuator motor, etc. complete with required variable frequency drive (VFD), relays, timers, contactors, PT, push buttons, switches, internal wiring, etc. Necessary civil work viz. foundation for placement of AHU, mounting of variable frequency drive (VFD) panel, construction of opening(s) for fresh/exhaust air etc. shall be covered in the scope of work.
24 Gauge (MS angle flanges)
22 Gauge (MS angle flanges)
20 Gauge (MS angle flanges)
18 Gauge (MS angle flanges)
FIRE DAMPER Supply, installation, testing and commissioning of fire damper complete with smoke detector/thermister, fusible link etc. and actuator as required for operation. The fire dampers shall be spring activated on melting of fusible link having melting point 67.13° C. The fire damper shall be located in the SA/RA ducts, at all fire rated crossoevers (shafts, walls, etc.). The control panel shall be located in such a way that the reset can easily be done. These combination smoke and fire dampers shall be interlocked with the building management system for the fire detection or HVAC and shall trip/close in the event of fire/smoke in the respective zone. Fire damper shall be tested as per ULL- 555 and certified by CBRI. The fire-damper shall be of at least 120 minutes fire-rating complete all as specified and directed. The fire dampers shall meet the following criteria: [a] Bare fire dampers with 400 mm sleeve [b] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position. [c] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers [d] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer.
Motorized, spring return type, combination fire and smoke damper
Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
THERMAL INSULATION S & F closed cell elastomeric nitrile rubber insulation with aluminum foil laminated on one side, having thermal conductivity not exceeding 0.037 W/mK at mean temperature of 20° C as per EN 12667, moisture diffusion resistance factor or ‘µ’ value of minimum 7,000 for base insulation material without the foil as per EN 12086, fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame and also fire performance of V0, HB as per UL 94, 1996, density without the foil between 40 to 55 kg/m³. The insulation material shall be FM (Factory Mutual) USA approved and dust & fibre free. The Aluminium foil shall be 60 microns thick and its weight shall be 193 gsm as per EN ISO 2286-2, tensile strength 90 N / 15 mm as per EN ISO 527-3 with elongation > 10% as per EN ISO 527-3 complete all as specified and directed.
13 mm thick nitrile rubber thermal insulation
ACOUSTIC INSULATION S & F open-cell engineered nitrile rubber foam acoustic insulation having good sound absorption, damping and barrier properties, antimicrobial product protection, thermal conductivity not exceeding 0.047 W/mK at 20° C, conforming to EN 12667, density 140-180 kg/m³ and conforming to class 1 rating for surface spread of flame in accordance with BS 476 Part 7 & UL 94 (HB, V-0). The acoustic insulation material shall be free of dust and fibre; it shall pass fungi/mould resistance as per DIN EN ISO 846 method A and bacterial resistance as per DIN EN ISO 846 method C and air erosion resistance test in accordance to ASTM Standard C 1071-05 without any laminate or covering (section 12.7) from an independent accredited testing agency complete all as specified and directed.
10 mm thick nitrile rubber foam acoustic insulation
SA/RA DIFFUSERS/GRILLES/LOUVERS Supply, installation, testing & commissioning of removable supply/return air diffusers/grilles or eye ball jet diffusers of extruded aluminum sections duly powder coated with volume control damper complete all as specified and directed.
EARTHINGS: - M & L for Earthing complete with Copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
NOTES :- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 5 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
NOTES : (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
SOLAR PANELS: - Supply, installation, testing and commissioning of SITC of 10 KW Solar roof top panel off Grid-tied system. The system have following specification and make :- Technical Specification of Inverter. Output : 230 Vac (+ 2.5%) Vac for 18 KW PCU shall be of three phase. Freqency : 50 Hz + 0.5 Hz Voltage regulation : +2% for DC I/p variation & o/p load variation. Wave form : PWM Sine wave Operation voltage range : 190 V to 250 V Harmonic distortin : Less than 3% Power factor : 0.8 Overlaod : 150% for 30 sec Crest factor : 3.1 Audible Noise : less than 45 dB at 1 Meter Operating temperature range : -10 to + 400C Inverter efficiency : 90% to 94% at full load Projection : Output overload & short circuit, output under & over voltage, DC under & over voltage Indications : Mains on, Inverter on Indication & Alarms : DC low, Fault, output overlaod Microprocessor, output & frequency, DC Voltage, Battery and load percentage
1. SPV modules > 250 Wp MNRE approved Nos - 40 2. Module Mounting Structure - 04 Set 3. 10 Kva PCU - 01 No 4. Battery Bank 96 V 800 Ah - 01 No 5. Array junction Box set - 04 6. Sub main junction box set - 02 7. 2x2.5 Sqmm PVC insulated copper cable - 20 RM 8. 2x4 Sqmm PVC insulated copper cable - 40 RM 9. 1x6 Sqmm PVC insulated copper cable - 40 RM 10.2x2.5 Sqmm PVC insulated copper cable - 40 RM 11. DC distribution board - 01 Set 12. AC dustrubtion board - 01 Set 13. Earthing set - 04 14. Lighting arreaster - 04 Set 15. Installation accessories - 01 Set 16. Spares & tools complete set 17. Cat log book/spare part manual
Major Components & technical specificaiton (a) Solar PV Module : Crystalline Silicon PV module with effiency > 15% and IEC 61215 & IEC 61730 Make Kosol/Equivalent (b) Module Mounting Structure : Galvanised MS module mounting structure with minimum thickness of galvanization 70 micron with SS nut & bolts designed to withstand wind speed as per IS875 and seismic factor of the site Make - TATA Steel/JSW (c) Junction box : Dust, vermin & waterproof made out of FRP Make - Fairwood Smart Green or equivalent (d) Inverters : Single phase string inverters ideal for rooftop systems coplying with all requirement for IP 65 equivalent protection thier housing provides reliable protection from dust and water incluidng high pressure washing with fast MPP tracking and a wide input voltage range to ensure the high levels of effieicnecy even at lower radiation to achieve an efficiency of upto 98.2% with integrated data logger. Warranty 05 years and extendable under AMC Make : Delta/OPS/Keco
(e) Distribution boxes, cables & accessories : An ACDB shall be provided in between PCU and load/grid interface with 32A MCB of suitable rating of connection and disconnection of PCU from laod. All the cable shall be supplied conforming to IS 1554/694 Part I of 1988 & shall be of 650 V/1.1 kV grade as per requirement. Make-Delta/OPS/Keco (f) Earthing & lightning protection : Earthing kits in adequate numbers to properly ground the array structures of the PV yard as per IEE regulation. Lighting and overvoltage protection of the SPV plant to be provided. (g) Battery Bank : Battery bank used will be of 96V 800Ah, each cell 2V1500Ah LMLA (Low Maintenance Lead Acid Battery) warranty of the battery bank will of 05 years including battery racks to layout the batteries in two or three layers vertically Make : Exide/Southern
Details of Power Plants : (a) SPV modules shall be designed and manufactured to meet the same recognized standard which must have been used extensively throughtout the world for more than a decade with an excellent track record of performance. SPV modules shall generate a peak power 250 Wp + 0.5 Wp or should be of higher capacity + 0.5 Wp under STC. Each module should have two separate interconnected strings with proper bypass diode(s). Minimum dimension of the SPV module shall be preferred. (b) Module Mounting Structure : Module mounting structure to be manufactured with steel angles and channels should be not dip galvanised or spray galvanised (c) Foundation : The foundation pedestals wherever necesary shall be concrete (d) Junction Box : The junction boxes shall be made up of module cast PVC, dust and vermin proof. The terminals shall be of appropriate size, junction boxes shall have suitable cable entry with suitable glanding arrangement for both input and output cables. Suitable marking on the bars shall have to be provided to
(e) Tool kit : Necessary tool kit is to be provided alongwith each battery bank for any immediate maintenance. (f) Distribution Board : Distribution boards shall be used. All MCBs, indicators, energy meters are to be interconnected through copper bus bar and are to be housed in a suitable sized sheet metal, enclosure. The panel board is to be grounded and for this purpose a suitable ground terminal is to be arranged. The panel board shall be coated with good quality paint. The distribution panel board shall be dust and vermin proof. The distribution panel board shall be wall mounted type and of front door opening type. The distribution panel board shall have suitable cable entry arrangement so that cable can be fastened with proper size gland laods.. The distribution shall be (g) Power Conditioning Unit : The power conditioning unit should convert DC power produced by SPV modules into AC power and adjust the voltage and frequency levels to suit the local grid conditions. Common technical specifications of the inverters Type- IGBT based
S & F AUDITORIUM SEATING CHAIRS of make Methodex Model Audi-3 as per sample kept in GE’s office or of techno commercial equivalent make in Goderj/featherlite/Penworkers as approved by GE. Fixing arrangements for chairs to floor will be as per manufacturer’s instructions, fixed firmly. All fasteners are zinc passivated. All exposed & visible parts shall be powder coated. Fabric-heavy duty 100% polyester dyed yarn with 3mm + 0.5mm foam backing resultant. the chairs shall be provided with following provisions as per manufacturers instructions and as directed by GE. (i) Row numbering-Row numbering for seats along the aisle. 2mm aluminium cutouts with row numbering A,B,C…(as applicable and as directed). (ii) Seat Numbering-Seat numbering on back and tip up portion 2mm aluminium oval strips with seat numbering 1, 2, 3……(as applicable and as directed)
Notes for item No. 162 (a) Aisle Side Lamp-Provision of lights on side for seats along the aisle polypropylene housing with 12 watt lamp. Cost of this element shall be deemed to to be included in lump sum cost of respective building of sch A part-I. (b) SEATING CHAIRS Where ever shown on drawing; seating shall be provided all as shown in respective drawings and as specified. The location of chairs shall be as decided by GE. (c) The chairs shall be procured at the fag end of the completion of work i.e. when all other works are completed to avoid any damage to the chairs. The chairs shall be PROCURED only after written direction from the GE. The work of chairs shall be executed only through the specialist and expert workers of the manufacturer.
ARBORICULTURE: - Supply and planting of below mentioned trees in 0.25- 0.3M poly bags with height 1.5 M to 1.8 Mtr incl digging holes 1.2M dia x 1.2 Mtr deep in ordinary soil and reffiling the same with the excavated earth mixed with manure or sluldge in the ratio 2;1 (02 parts of stacked volume of earth after reduction of 20% with 1 parts of stacked volume of sludge of manure after reduction by 80% flooding with water and removed of surplus soil and rate inclu maintaining the plants for 2 years :-
Shisham
Nimbu
Pomegranate
Gulmohar
M & L for grassing the area with Cyndan Dactylon (Calcutta grass) having rhizomes with sufficient nodes in row of 5 cm apart in either direction & watering, maintenance of lawn till the grass form a thick lawn free from seeds & fit for mowing including spreading of good earth & compst complete all as specified & directed. NOTE:- Grassing shall be carried out to carpetting effect i.e. installation 80% of the ground shall not be visible due to plant cover, if the desired effect is not obtained then additional grass will be planted at specified locations to achive the effect.
NOTE for Sl Item No 163.00 TO 164.00 (i) Height of plant shall be measured from top of follage ( not from the isolated branch/leaf,main stem) to 150mm from top of root. (ii) Water will not be supplied by MES. Contractor has to make his own arrangement for watering to plants. (iii) The rates quoted by the contractor deemed to include watering, maintenance of plants till two years after certified date of completion of work. (iv). During two years after completion if any plant is found dead, or not of satisfactory growth, plants of approved size and shape shall be provided without any extra cost to the state. (v). Supply and application of manure, sweet earth and pesticides, fertilizers, etc up to two years after completion of are deemed to be included in the quoted unit rate. (vi) The plants shall be brought at site Six months before the date of completion of the work or as directed by GE. (vii) Tenderer to note that 20 % cost of quotation against these items shall be retained for two year after completion. In case of failure by the contractor to maintain the plants as above, the same shall be caried out by the department at his risk and cost and the expenditure shall be deducted from the retained amount and performance security deposit.
OPERATION OF CENTRAL AC PLANT
Provision of services for operation of HVAC plants installed at Auditorium including including all equipments such as chillers, condensors, all type of pumps and motors, panels, cooling towers, AHU, DG set 500kva, insulating ducts, fans and all types of valves etc. in for 08 hours on each day, including sundays/holidays, for FIRST YEAR from the certified date of completion of work under the Ph-I by deploying one number technically qualified technical tradesman as approved, specified and directed by the GE. Note: - 1. Tentatively the shifts will be maintianed as under (a) First shift 0600 hrs to 1400 hrs. (b) Second shift 1400 hrs to 2200 hrs. Note: -2. However the working hours and exact time table for the duration of shifts required shall be as decided by the GE fortnight basis in advance as per operational requirement. No claim whatsoever shall be entertained incase of increase/decrese in shifts on any day.
Provision of services for operation of HVAC plants installed at Auditorium including including all equipments such as chillers, condensors, all type of pumps and motors, panels, cooling towers, AHU, DG set 500kva, insulating ducts, fans and all types of valves etc. in for 08 hours on each day, including sundays/holidays, for SECOND YEAR from the certified date of completion of work under the Ph-I by deploying one number technically qualified technical tradesman as approved, specified and directed by the GE. Note: - 1. Tentatively the shifts will be maintianed as under (a) First shift 0600 hrs to 1400 hrs. (b) Second shift 1400 hrs to 2200 hrs. Note: -2.However the working hours and exact time table for the duration of shifts required shall be as decided by the GE fortnight basis in advance as per operational requirement. No claim whatsoever shall be entertained incase of increase/decrese in shifts on any day.
MANGLA AMIT BUILDERS PVT LTD
RAGHUSONS INFRA ENGINEERING PVT. LTD
FRIZO INDIA PVT LTD
GANGA INFRABUILD PVT LTD
Jatan Constructions Private Limited
SOOD ASSOCIATES PVT LTD
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid