Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.1 L+₹3.1 L (14.9%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹22.7 L
EMD Value
₹45,500
Closing Date
9 Oct 2021, 6:00 pmClosed
GE 881 EWS
GE 881 EWS C/o 56 APO
PROVN OF 01 X OVERHEAD SHED FOR GENERATOR SET AT AP AT GULPUR AND SPL REPAIRS TO BLDG NOS P-47, T-05, P-134, P-79, T-88, T-53,T-54, P-1/B P-6 AT GULPUR, MFVH UNDER GE 881 EWS
2021_MES_467961_2
GE/PNH-26/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹45,500
Yes
21 Jun 2022
14 Sept 2021
11 Oct 2021
14 Sept 2021
9 Oct 2021
22 Sept 2021
Amount
Surface excn n.exc avg 15cm in any type of soil complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc 0.50 cum Getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and 1.5 mtr deep and getting out in hard/dense soil complete all as specified and directed.
Removing excavated material (soils) not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Returning and filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in any type of soil, complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate in post holes complete all as specified and directed.
M & L for Cement concrete 1:4:8 type D2 as in foundations,filling and mass concrete in foundations,filling and mass concrete complete all as specified and directed.
M&L for Hardcore of guage exc 63mm but n exc 100mm, deposited spread and levelled in layers n exc 15cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick PCC M-20 using graded aggregate 20mm graded aggregate type B-1 (Nominal mix) as in flooring complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from the Frame) not exc 1.50 Sqm, complete all as specified and directed. .
Taking down shutter of any description exc 1 sqm but not exc 2 sqm and removing from site each complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from chowkat) exc 1.50 Sqm but not exc 4.00 Sqm each complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening, complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame complete all as specified and directed.
S & F pressed steel box type window with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, guazed bar and Guard Bar and devetailed or welded complete all as specified and directed.
S&F 2nd class hardwood plain solid straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F 2nd class hard wood, 35 mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers supply and fixed to chowkats complete all as specified and directed.
S&F Factory made, 2nd class hard wood, 35 mm thick, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I section 8, clause 8.24 (B) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F of size 105x60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
S&F in repair Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&F In Repairs in position suspended false ceiling using E- grid suspended ceiling grid system of grid size 600x600mm with GI frame work of main runner 38 x 24mm sheet thickness 0.4mm, cross Tee 28 x 24mm sheet thickness 0.3mm and wall angle 24 x 24mm x 3mm using 4mm thick high pressure stream cured classic variant E-board, designer pattern (ISI marked, IS No 14862-2000) fibre cement E board to be placed in the grid suspended by 4mm GI wire hangers from the purlins of the roof with butter fly clips complete all as specified and directed. Make:- Everest Industries Ltd or as approved by GE.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching ot drilling out old glazing pins/spring clips and fixing new onces ,complete all as specified and directed.
S&F Sheet glass, ordinary quality, 3 mm thick and glazing with oil putty or wooden beads, in square n exc. 0.5 Sq.m pane, complete all as specified and directed.
S&F Figured glass, 4.0 mm thickness pin head type and glazing with oil putty in squares n exc 0.5 sqm in each panel complete all as specified and directed.
S & F chimney bars (straight or camber) bearing bar ton-gues or water bars for window frames, window guard bars, plain let in and fixed independently in wooden frames, L or T section support for shelves etc., and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F 100 mm long mild steel butt hinges, medium weight, cold rolled complete all as specified and directed.
S&F Butt hinges medium weight cold rolled mild steel 75 mm complete all as specified and directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 150mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 75 mm of aluminium, anodised, barrel tower bolt extruded section complete all as specified and directed.
S&F 100 mm long aluminium handles, cast type, anodised complete all as specified and directed.
S&F 150 mm long aluminium handles, cast type, anodised complete all as specified and directed.
Roughning surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise complete all as specified and directed.
Demolition of cement concrete in ground floors and paving (unreinforced) n exc. 15 cm thick, (below or above ground level), complete all as specified and directed.
Demolition of Cement concrete (unreinforced ) in roof floors (other than ground floor) and similar works complete all as specified and directed.
Dismantling of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) with uniform thickness of 50mm laid in two layers of 25 mm thickness each with wire netting of 0.90mm dia and size of mesh 12mm x 12mm laid between the two layers and binding with MS wire 0.90mm dia (annealed), finished even and smooth without using extra cement on top layer as in roof padding complete all as specified and directed. NOTE : wire mesh shall be measured and paid for separately under respective item.
Supply only Wire netting of galvanised steel wire 0.90 mm dia and size of mesh 12mm x 12mm, including 50mm longitudinal/cross sectional over laps complete all as specified and directed.
M&L for Providing, cement concrete 1:2:4 Type B-1 (using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for Non skid coloured glazed ceramic tiles 7 to 8 mm thick square/rectangular area of each tile exc 0.11 sqm not exc 0.18 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to matchlaid over and including screed bed or bedding layer of 15 mm thick in cement morter (1:4) complete all as specified and directed.
Taking down cement plaster from stone/brick walls including raking out joints for keys and scrubbing down with water etc, complete all as specified and directed.
M&L for Rendering 10 mm thick on other than fair of brick of concrete surface in M 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 5 mm thick on cieling surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 5 mm thick on brick work or concrete concrete surface in CM 1:3, finished even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 15 mm thick on brick work or concrete concrete surface in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 15 mm thick on other than fair of brick of concrete surface in M 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L Glazed ceramic tiles in vertical surface 450x350mm x 7mm thick skarting ,dado,over and incl 10mm th screed in CM 1:4 as backing coat of wall tiling of walls, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
S& F for 75mm pvc bends (any radius)diminishing pieces or tapers(larger bore measured) complete all as specified and directed.
S&F for 100mm pvc branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S& F for 100mm pvc bends (any radius) with duck's foot or heel rest complete all as specified and directed.
S&F 75mm PVC (SWR) floor trap with CP grating including jointing with solvint cement complete all as specified and directed.
S&F 75mm dia bore PVC (SWR) pipes sungle shocketed, in any length with rubber ring joints ,laid in trenches or in floor, complete all as specified and directed.
S&F 110mm dia bore PVC (SWR) pipes sungle shocketed, in any length with rubber ring joints ,laid in trenches or in floor, complete all as specified and directed.
S&F 110mm PVC (SWR) Bends complete all as specified and directed.
Taking up or down steel tubing and connections for 15mm bore, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore, including cleaning for refixing or removal to store complete all as specified and directed.
S&F for 15mm dia steel tubing, " medium grade', galvanised, with all fitting; laid in trenches complete all as specified and directed.
S&F for 20mm dia steel tubing, " medium grade', galvanised, with all fitting; laid in trenches complete all as specified and directed.
S & F Bib tap 15 mm bore,fancy type, chromium plated with long shank and cup (concealed type)screwed down screwed for iron pipe or for brass ferrule and fixed in repair complete all as specified and directed.
S & F Angle/Stop valve (ISI Marked), cast copper alloy fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore and fixed in repair complete all as specified and directed.
S&F in repair Pillar taps, fancy type,cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15mm bore complete all as specified and directed.
S&F PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and directed.
S&F Vitreous china Squatting pan Orissa pattern size 580x440mm white with integral foot rest including connection to trap and to flushing pipe , anti syphonage pipe etc fixed in repair complete all as specified and directed.
S&F PVC vaveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 Ltr capacity fixed in repairs complete all as specified and directed.
S&F vitreous china wash basin, white, Oval type, size 630x450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe fixing only in repairs complete all as specified and directed.
S&F in repair, Vitreous China urinals, Half stall type, white (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating 125mm with hole and Union for discharge pipe. Inclusive of fixing supply pipe to flushing cistern, trap and 32mm waste pipe, 32mm waste coupling and PVC urinal spreader, complete all as specified and directed.
S&F Grating 125 mm size of PTMT (Minimum weight 40gms) complete all as specified and directed.
S&F 32mm bore PVC waste pipe suitable for wash basin & Urinal etc complete all as specified and directed.
Dismantling water tank exc 500 ltr and n. Exc 1000 ltr and removing to store complete all as specified and directed.
S&F PVC water tank of capacity 1000 ltr Rotational moulded polyethylene (cylindrical vertical with closed top) hoisted and fixed in position incl 20mm "Brass" float valve, complete all as specified and directed.
M & L for preparation of new steel surfaces applying two coats of synthetic enamel paint over 10 cms width or girth over a coat of red oxide primer etc. complete all as specified and directed.
M&L for Prepration of old or previously undecorated steel or steel based surface of any description over 10 cm in width or girth not other wise described, and applying one coats of synthetic enamal paint complete all as specified and directed.
M&L for Two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces over 10 cm in width or girth including preparation of new or previously untreated surfaces of wood complete all as specified and directed.
M&L for two coats of white wash on old plastered surfaces including preparation on ceiling complete all as specified and directed.
M&L for three coats of white wash on new plastered surfaces including preparation on Walls complete all as specified and directed.
M&L for three coats of white wash on new plastered surfaces including preparation on ceiling complete all as specified and directed.
M&L for one coats of white wash on old surfaces including preparation on Walls complete all as specified and directed.
M&L newly plastered surface of walls and applying two coat of cement paint over a coat of primer. Complete all as specified and as directed.
M&L for two coats of Distemper oil emulsion over a coat of putty on new plastered surfaces including preparation on Walls complete all as specified and directed.
M&L for two coats of Distemper oil emulsion on old plastered surfaces including complete removal of existing treatment and preparation on Walls complete all as specified and directed.
M&L for 50mm thick PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
Demolition of Brick work or stone/boulder masonary built in CM incl. all quoins, arches, pillars,etc complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:4 complete all as specified and directed.
M&L for random rubble stone masonary in CM 1:6 complete all as specified and directed.
All as per item No. 88 above but except stone complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregates as in anchoring hold fast, parapets, copings, apex plates, bed plates and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F Mild steel TMT bar 6mm to 8mm dia cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (unnealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
S & F steel work in tubular trusses, coloumns incl special shaped washer etc., complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 complete all as specified and directed.
M&L for Providing precast reinforcement cement concrete(1:2:4) type B-1 using 20 mm graded stone aggregate in Cover slabs (for man holes etc.) shelves and similar articles with plain faces including neccesary moulds and setting in cement mortar in 1:4 complete all as specified and directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M&L for Reinforced cement concrete 1:1.5:3 type B1(using 20 mm graded stone aggregate) in chajjas etc. complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section in any position as in unframed work, complete all as specified and directed.
M&L 2nd class soft wood as in scantling clean sawn timber framed and fixed in staircase work complete all as specified and directed.
Demolition and breaking up 150mm dia drain pipes(Salt glazed ware,AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M&L for Salt galzed stone ware drain pipes 150mm dia graded "A" laid in trenches, jointed and tested complete all as specified and directed.
M&L for PCC (1:3:6) type C-2(Using 40 mm graded coarse aggregate) as in bed to 150mm dia drain pipe including packing under, and honching aginst the size of pipe after they are laid and tested complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F 0.63mm thick class-8 galvanised corrugated mild steel sheeting with two corrugation side lap fixed with L-type or J-type or cranked hook bolts IN roof ,covering wall etc with grade of zinc coating and bent to curved of any radius, complete all as specified and directed.
All as per serial item No 104 above but except sheets complete all as specified and directed.
S & F 0.80 mm thick, plain galvanized,mild steel sheeting in ridges, hips, valley gutters, drip and straight flashing (length and girth as fixed) with L type or J type or cranked hook bolts, in roofs, covering wall etc with grade of zinc coating and bent to curved of any radius complete all as per specified and directed.
M & L for preparation of old steel surfaces & applying one coats of synthetic enamel paint over 10 cms width or girth over a coat of red oxide primer etc. complete all as specified & directed.
Preparation of old or previously undecorated wood or wood based surface of any description over 10cm in width or girth not other wise described, any applying one coats of synthetic enamel paint complete all as specified and as directed.
Taking down carefully unserviceable copper/ aluminium point wiring of any description including all fittings (switch , socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes complete all as specified and as directed.
Dismantling and taking down unserviceable main switches, DB etc. any type / size and making good disturbed surfaces to match with the existing finishes complete all as specified and as directed.
M&L for Point wiring with two single core, 1.5 Sqmm (nominal area) size multistranded copper conductor cable and one single core 1.5 sqmm (nominal area) size copper conductor cable, as earth continuity conductor connected to common earth dolly,1100 volts grade , FRLS, PVC insulated unsheathed cable in and including PVC casing capping/ conduit of suitable size with PVC boards of appropriate sizes and all requisite accessories complete with PVC terminals box for mounting switches, sockets, fan regulators etc for the followings:-
One light point controlled by one switch complete all as specified and directed.
One fan point (Ceiling and Exhaust) controlled by one switch complete all as specified and directed.
One 5 pin, 6 A socket outlet on the same board complete all as specified and directed.
One 5 pin, 6 A socket outlet on the independent board complete all as specified and directed.
All as per item No 109 above but with two 2.5 sqmm size cables as phase and neutral and one 1.5 sqmm size cable as earth continuity conductor for one 15 Amps socket outlet independent complete all as specified and directed.
S&F in repair switch flush type single pole one way 5 Amp complete all as specified and directed. Make : Anchor/ Cona/Havells
S&F in repair switch flush type single pole one way 15 Amp ISI Marked complete all as specified and directed. Make : Anchor /Cona/Havells
S&F in repair socket outlet 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed. Make : Anchor /Cona/Havells
S&F in repair socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type ISI Marked complete all as specified and directed. Make : Anchor /Cona/Havells
S&F in repair Ceiling rose, 3 terminal/PVC/ polycarbonate, isolated body ISI marked modular type complete all as specified and directed. Make : Anchor/Cona/Havells
Taking down fan, sealing cable end, dismantling blades and removing fan and blades complete all as specified and directed.
M&L for Hanging of ceiling fan and connecting up including providing of cable from ceiling rose or connector to fan complete all as specified and directed.
S&F ceiling rose, 3 terminal, surface bakelite 65 x 50mm complete all as specified and as directed.
S&F Piano type switch, 1 way,6 Amps, flush type, complete all as specified and as directed.
S&F Switch socket combination 5 pin, 6 Amps, flush type, complete all as specified and as directed.
S&F Switch socket combination 2 in 1, 5 and 15 Amps, flush type, complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin, 5 Amps , flush type, complete all as specified and directed.
S&F in repair angle holder Lamp holder insulated body complete all as specified and directed.
S&F in repair Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings with & including LED lamp 10 watts (B-22 holder), complete all as specified. Make of LED lamp:- Havells cat part No LHlDERUEML8x010 or Equaivalent cat part of make as specified in P.S.
S&F electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed.
S&F bulk head fitting , 9/10 watt LED light driver holder, surface mounting, suitable for outdoor use complete all as specified and directed.
S&F in replacement wall mounted LED Tube light fittings with universal single side connection battern and ultra bright integrated aluminium heat sink 20 watt LED T8 tubelight single side connection complete all as specified and as directed.
S&F in replacement LED Tube light fitting suitable for LED 20W tube rod made out of with polycarbonate housing & integrated electronic driver complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including 20W LED tube rod fixed in repairs, complete all as specified and directed. Make:-Havells Cat Part No:-LHLDEFXD5L8R020 for LED tube rod & Cat Part No:-LUMILINEPLUSBS20WLED865SPCSS or Equaivalent cat part of make as specified in P.S. Note :- The LED batten and LED tube rod shall be of same make.
S&F in repair LED street light fittings 25 Watt made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete with hosing with all accessories pre wired with and including 40mm dia GI pipe bracket of 1.2 mtr made to shape as required fixed on wall or pole with FI clamp of required shap & 40x6mm size, nut, bolts, washers and making connection with 3 core copper flexible cable of suitable size to light fitting fixed in repairs, complete all as specified and directed. Make:-Havells Cat Part NoENDURAPEARLSL25WLED757SASYTOPCMP or Equivalent cat part of make as specified in PS.
S&F Building security light fittings LED 35 watt 230 volts AC ou door type wityh high pressure die cast aluminium housing and heat resistant complete wih driver, lamp breacket with impact and corrosion resistant including thermal management in multipal optic complete with IP 65/66 protection complete all as specified and directed.
S&F Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. Make:- Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make as specified in P.S.
S&F Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 4 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. Make:- Havells cat part No-DHDPSHODPW04 or Equivalent cat part of make specified in PS.
S&F MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F MCBs, SPN, 240 volts, breaking capacity 10 KA, rating 32-40 amps, complete all as specified and as directed. Make: L&T / Legrand /Standard/Havells
S&F MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
Supply & Fix in repairs, laying & testing of cable in trenches/poles XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 4 core 16 sqmm complete all as specified and directed.
S & F, connecting, 1100 Volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular of size of aluminum conductor 16 sq mm stranded conductor including taking down old UNSV cable of any type / size, complete all as specified and directed.
M&L for house sevice bracket (hook type) complete with 3.0 m long GI pipe 40 mm dia Med. Grade, two Nos, 90 degrees, bends M.S. hook and stay or guy including taking down old UNSV bracket complete all as specified and directed.
S & L brick covering with width equal to length of brick as the mechanical protction to cable with well burned sub class 'B' laid in trenches flat complete all as specified and directed.
S & R pipe galvanized iron light grade complete with all fittings laid in road crossing and on pole buildings complete all as specified and directed ISI marked of 40 mm bore complete all as specified and directed.
M & L for earthing complete with galvanized Steel earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 meters below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and incl galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main earth wire on pole or controll board GI pipe light grade 20mm bore for watering funnel with wire mesh PCC chamber pit in PCC 1:3:6 type C-1 40mm yhick Precast RCC -25 cover reincorced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50m complete all as sprecified and shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
S&F LED lamp CDL 10 watt with holder base (B22) type, complete all as specified and directed. Make of LED lamp:- Havells cat part No LHLDEUEEML8R010 or Equivalent cat part of make as specified in Appx 'A' to P.S.
M/S FAIZ AHMED KHAN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .