Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAdmitted-Finance | ₹2.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.2 Cr+₹4.4 L (2.01%)Admitted-Finance | ₹2.2 Cr+₹4.4 L (2.01%) | L2 | Admitted-Finance |
| 3 | L3₹2.5 Cr+₹31.8 L (14.6%)Admitted-Finance VILL CHANDANPUR KAYASTH DEOBAND SAHARANPUR UP | SAHARANPUR | UTTAR PRADESH | 247001 | ₹2.5 Cr+₹31.8 L (14.6%) | L3 | Admitted-Finance |
| 4 | L4₹2.7 Cr+₹51.1 L (23.5%)Admitted-Finance | ₹2.7 Cr+₹51.1 L (23.5%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically Disqualified |
| Sl No | Description | Qty | Unit | ASHISH ELECTRICALS L4 | Raj Electricals L2 | JAI BHAWANI ELECTRICALS L3 | M/S Pooja Electricals L1 |
|---|---|---|---|---|---|---|---|
| 1.00Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced | |||||||
| 2.00 | LED Street Light fixture 70 Watt | 65 | Each | 2,850 ₹1,85,250 | 3,800 ₹2,47,000 | 5,000 ₹3,25,000 | 1,800 ₹1,17,000 Lowest |
| 3.00P/Laying XLPE/P.V.C. insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS: 1255 including excavation of 30cm×75cm size trench, 25 cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. Make :- Havells, Paramount, Gemscab & Pollycab,KEI | |||||||
| 4.00 | 4 Core 185 Sqmm Armoured | 2,650 | Mtr | 950 ₹25,17,500 | 850 ₹22,52,500 | 750 ₹19,87,500 | 700 ₹18,55,000 Lowest |
| 5.00 | 4 Core 300 Sqmm Armoured | 200 | Mtr | 1,050 ₹2,10,000 | 1,220 ₹2,44,000 | 1,700 ₹3,40,000 | 1,000 ₹2,00,000 Lowest |
Tender Value
₹3.5 Cr
EMD Value
₹7.0 L
Closing Date
1 Nov 2022, 6:00 pmClosed
ACE-I RHB
Additional Chief Engineer-I Rajasthan Housing Board Jyoti Nagar Janpath Jaipur
External Electrification and Street Light work of commercial blocks sector-23 between Pratap Nagar Chaupati and Mahal Road Pratap Nagar Jaipur
2022_RHBCE_300700_3
ACE-I_07/2022-23
Open Tender
Electrical Works
Percentage
270 days
Jaipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
As per NIT
₹7.0 L
Yes
16 Nov 2022
12 Oct 2022
3 Nov 2022
12 Oct 2022
1 Nov 2022
12 Oct 2022
Amount
Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced
LED Street Light fixture 70 Watt
P/Laying XLPE/P.V.C. insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS: 1255 including excavation of 30cm×75cm size trench, 25 cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. Make :- Havells, Paramount, Gemscab & Pollycab,KEI
4 Core 185 Sqmm Armoured
4 Core 300 Sqmm Armoured
Bidder Name
Amount
ASHISH ELECTRICALS(GSTN-08AHXPC7032J1ZZ)
Raj Electricals(GSTN-08AGBPS1419A1ZV)
JAI BHAWANI ELECTRICALS(GSTN-08AAMFJ3298F1ZZ)
M/S Pooja Electricals(GSTN-08AMJPM5477G1ZM)
JAI BHAWANI ELECTRICALS
Raj Electricals
ASHISH ELECTRICALS
M/S Pooja Electricals
JAI BHAWANI ELECTRICALS
ASHISH ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
cagr.pdf
Tender Documents • 2.46 MB
BOQ_533647.xls
BOQ • 0.33 MB
gs.pdf
Tender Documents • 0.29 MB
tbid.pdf
Tender Documents • 11.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .