Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.14Accepted-AOC | ₹16.14 Quoted ₹16.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹16.6 LRejected-Finance | ₹16.6 L | L2 | Rejected-Finance L2 |
| 3 | L3₹17.3 LRejected-Finance MEHEM ROAD NEAR TVS BIKE AGENCY GOHANA SONIPAT HARYANA 131301 ON MEHAM ROAD NEAR TVS BIKE AGENCY GOHANA 131301 | SONIPAT | HARYANA | 131301 | ₹17.3 L | L3 | Rejected-Finance L3 |
| 4 | L4₹18.4 LRejected-Finance | ₹18.4 L | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | KKM Engineering Solutions Pvt. Ltd. L4 | P M Infrastructure and Develepors L2 | PS ELECTRIC L3 | M/s. PK Construction Company L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 48" (1200mm) | 105 | Each | 2,200 ₹2.3 L | 2,054 ₹2.2 L | 2,100 ₹2.2 L | 2,000 ₹2.1 L |
| 2.00 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe.Group C | 467 | Each | 750 ₹3.5 L | 710 ₹3.3 L | 750 ₹3.5 L | 705 ₹3.3 L |
| 3.00 | Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C | 119 | Each | 1,000 ₹1.2 L | 935 ₹1.1 L | 950 ₹1.1 L | 925 ₹1.1 L |
| 4.00 | Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C | 107 | Each | 1,400 ₹1.5 L | 1,292 ₹1.4 L | 1,300 ₹1.4 L | 1,200 ₹1.3 L |
| 5.00 | Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) | 1,150 | P.Mtr | 60 ₹69,000 | 53 ₹60,950 | 60 ₹69,000 | 50 ₹57,500 |
| 6.00 | 1 run of Size 2.50 Sqmm(1.1.80mm) | 2,100 | P.Mtr | 90 ₹1.9 L | 78 ₹1.6 L | 90 ₹1.9 L | 75 ₹1.6 L |
| 7.00 | 1 run of Size 4 Sqmm(1/2.24mm) | 1,170 | P.Mtr | 120 ₹1.4 L | 109 ₹1.3 L | 115 ₹1.3 L | 105 ₹1.2 L |
| 8.00 | Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire s PVC pipe of 25 mm dia.atisfaction of Engineer-in-Charge of work. | 1,250 | P.Mtr | 40 ₹50,000 | 32 ₹40,000 | 38 ₹47,500 | 30 ₹37,500 |
| 9.00 | Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.Bell Push | 45 | Each | 85 ₹3,825 | 77 ₹3,465 | 80 ₹3,600 | 75 ₹3,375 |
| 10.00 | Step type Fan Regulator 2 modules 300 watt | 105 | Each | 290 ₹30,450 | 257 ₹26,985 | 300 ₹31,500 | 245 ₹25,725 |
Tender Value
₹16.6 L
EMD Value
₹33,200
Closing Date
25 Dec 2025, 5:00 pmClosed
NAVIN KUMAR
ED - Gurgaon
Setting up of 15 no. courts at Gurugram (Pdg EI Only)
2025_HRY_491751_1
202531E4BC2E 7840 4058 AED4 F796B11FC145664BAR
Open Tender
Civil Works
30 days
Gurugram
2 documents required · 2 mandatory
₹1,000
₹33,200
Yes
11 Feb 2026
19 Dec 2025
26 Dec 2025
19 Dec 2025
25 Dec 2025
19 Dec 2025
19 Dec 2025 - 20 Dec 2025
Amount
Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 48" (1200mm)
COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe.Group C
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)
1 run of Size 2.50 Sqmm(1.1.80mm)
1 run of Size 4 Sqmm(1/2.24mm)
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire s PVC pipe of 25 mm dia.atisfaction of Engineer-in-Charge of work.
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.Bell Push
Step type Fan Regulator 2 modules 300 watt
Erection of exhaust fan in existing opening, complete with necessary earthling of fan including carriage from PWD store to the site of work.
Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless stell wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required
Providing and fixing outdoor duty Ply of 8 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required
Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp, 25 KA
4 pole MCCB 125 to 160 amp, 25 KA
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work.TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)
TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
40 amp to 63 amp. MCB's Four Pole
Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia
Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 25x12 mm
Earthing with G.I. earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
Extra for using salt and char coal/coke for pipe earth electrode as required
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm
Providing & erection/ laying of PVC/ XLPE insulated underground aluminium conductor underground cable loose in existing pipe or trenches complete in all respect with necessary connection upto the entire satisfaction of engineer in charge of the work. 16 Sq mm 4 core (Arm.)
25 Sq mm 3.5 core (Arm.)
150 Sq mm 3.5 core (Arm.)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver asper the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineerin Charge as per requirement.LED junction temperature shall not rise above 90°C).70 Watt
P M Infrastructure and Develepors (BID ID -1394054)
PS ELECTRIC (BID ID -1394103)
KKM Engineering Solutions Pvt. Ltd. (BID ID -1393713)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
BOQ_570074.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid