| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹24.8 L+₹6.7 L (36.7%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹34.0 L+₹15.9 L (87.2%)Rejected-Finance | L3 | Rejected-Finance Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
16 Oct 2023, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
REPAIRS TO KITCHEN CABINET IRON DOOR INTERNAL FINISHEs SUNKEN GI FITTINGS FLOORING AND CERTAIN BR WORKS IN CIVIL ZONE AND MES COLONY OF CAMERO COMPLEX AND REPAIR REPLACEMENT OF STREET LIGHTS FLOOD LIGHTS SECURITY LIGHTS FITTINGS OF CAMER
2023_MES_619697_1
GE/SP/ TOKEN-37/2023-24
Open Tender
Civil Works
Item Rate
120 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹80,000
Yes
19 Mar 2024
20 Sept 2023
23 Oct 2023
20 Sept 2023
16 Oct 2023
4 Oct 2023
Amount
Taking down of old /unserviceable kitchen cabinet / Cupboard incl all fixture and fittings. Note :- For measurement superficial area in elevation will be measured only.
S&F factory made 18mm(+0.7mm) thik celuka PVC Ply of density 600kg/cbm manufactured by an ISO-900-2008 certified company.One side prelam and other side plain 18mm thick Celuka PVC ply for kitchen cabinet and cupboards shutter and also manufacturer's test report and test certificate is mandatory with each and every supply of the materail complete as per directions of Engineer-in-charge,manufecturer's specifications and drawing.
S&F factory made 18mm(+0.7mm) thik celuka PVC Ply of density 600kg/cbm manufactured by an ISO-900-2008 certified company.Plain 18mm thick Celuka PVC Ply for Shelf/Partitions/Drawer and also manufacturer's test report and test certificate is mandatory with each and every supply of the materail complete as per directions of Engineer-in-charge,manufecturer's specifications and drawing.
S&F factory made 5mm thik PVC sheet of density 600kg/cbm manufactured by an ISO-900-2008 certified company.Plain 5mm thick PVC sheet paneling for back side(wall side) and also manufacturer's test report and test certificate is mandatory with each and every supply of the materail complete as per directions of Engineer-in-charge,manufecturer's specifications and drawing.
S&F continous piano hinges,stainless steel, bright finish or electrogalvanised of width of flap 30mm
M &L for 50 mm magnetic catches and fixed complete all as specified and directed by Engr-in- Charge.
S&F 100mm Hasp and staple, safety type, with mild steel hinges pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engr In Charge.
S&F 100 mm size Stainless Steel handle complete all as specified and as directed by Engr -in - Charge.
S & F 25 mm dia anodised aluminium alloy with powder coated curtain rod complete all as specified and directed by Engr In Charge.
S&F for aluminium powder coated fancy type side bracket (Lattoo) for curtain rod complete all as specified and directed.
S&F wall bracket for drapery rod as per sample approved by Engr-in-Charge.
S&F stainless steel knobs complete all as specified and as directed
S & Fin repairs galvanised Stainless steel wire cloth of 0.36mm dia wire and average width of aperture 1.4mm & fixed with tacks of stainless steel wire staples,etc complete all as specified and as directed.
M&L framed work of Fe-410W (Gde E-250) quality B as in doors or gates of angle or other section wwith gusset plate, rails, braces etc, complete drilled for fixing of steel sheeting or other covering, door etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of stee, sheeting or other coverings, running rails and guides) and hanging: also fastening and fixing and making good the disturbed surface with PCC 1:2:4 complete all as specified and as directed by the Engr-in-Charge.
Mild steel, 1.00mm thick plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
Welding in repairs not exceeding 2.5 cm in length thickness of metal to be welded exceeding 6 mm but not exceeding 9 mm.Note Rate including taking down steel window or door chowkhat , ventilator frame and welded with Angel iron /MS Flat as required length and refix the same and making good disturbed area all as specified and directed by Engr-in Charge
Welding in repairs of ventilator window or other opening up to 4 Sqm including taking down steel window or door chowkhat , ventilator frame and welded with Angel iron /MS Flat with wire mesh complete up to 4 story as required length and refix the same and making good disturbed area all as specified and directed by Engr-in Charge
M&L for 18mm to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling of stone slab complete all as specified and directed by Engr-in-charge.Note : Debris removed from site upto 20 Km outside of MOD land
Demolition reinforced cement concrete of roofs, floors (other than ground floors), beams, staircases, landing, chajjas, RCC Jali and similar suspended work (reinforcement cut as required to facilitate demolition) up to forth story Bldgs incl removingfrom site to out of defence land complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced cement concrete nominal mix 1:2:4, type B-1 using (20mm graded aggreate) in slabs supported on walls, beams and column in floors,roofs,landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-In-Charge.
M & L formwork to chullah hoods, chajjas, slab, trough and similar items including edges finished rough surfaces of concrete complete all as specified and directed by Engr-In-Charge.
S& F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire(annealed) not less than 0.9mm dia complete all as specified.
Taking down steel tubing or removing from site of 15mm bore pipe all as specified and directed by Engineer-in-charge.
All as above item No 23 but 20mm bore.
Demolition of brick work built in CM incl all quoins, pillars etc but excl ashlar facings, dressed stone work and precast concrete
M&L brick work with old size sub class B brick straight or curved on plan exc 6 m mean radius in half brick thick wall built in cement mortar in CM 1:4 complete all as specified and directed.
M&L for brick work with subclass B bricks, straight or curved on plan to any radius built in CM 1:6 all as specified
M&L for rendering CM (1:6) 15 mm thick on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
M&L rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth with using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
M&L for 15 mm thick cement plaster in cement mortar 1:6 on Bk surfaces on fair face of brick work and finished even and smooth w/o using extra cement including taking down cement plaster of any description on brick or concrete surfaces of walls or ceiling etc incl. raking out joints ,hacking for key and scrubbing down with water upto 4 storeys building complete all as specified & Directed by Engr-in-Charge.
M&L rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth with using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
M&L for 10 mm thick cement plaster in cement mortar 1:3 on concrete or brick surface and finished even and smooth w/o using extra cement as in ceiling including taking down cement plaster of any description on brick or concrete surfaces of walls or ceiling etc incl. raking out joints ,hacking for key and scrubbing down with water upto 4 storeys building complete all as specified & Directed by Engr-in-Charge.
M&L for preparation of new surface and applying two coat of distemper on wall/ceiling including 3 mm wall care putty complete all as specified and directed.
M&L for preparing surfaces of new plaster on walls and applying exterior two or more coats of APEX/WEATHER over 3mm putty including priming coat of exterior primer applied complete all as specified and directed by Engr-in-Charge.
S&F 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
All as per item No 35 but 20mm bore
S&F in repairs pillar tap, fancy type,cast copper alloy, chromium plated, with capston heads screwed down, high pressure with or without lettered hot or cold with long screwed shames and fly nuts, screwed for 15mm bore pipe
M&L for Non-skid coloured ceramic tiles, 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm, in floors/wall etc, set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over including 15 mm thick screed bead in CM 1:4, including dismantling of tiles complete all as specified and directed by Engr-in-Charge. Note : Debris removed from site upto 20 Km outside of MOD land
M & L for Glazed ceramic coloured tiles of size 350x 250x 7mm/ 450X 350X 7 thick on vertical surface such as in dado/skirting/risers to steps etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles and including 10 mm thick backing coat in CM (1:4) including dismantling of tiles complete all as specified and directed by Engr-in-Charge. Note : Debris removed from site upto 20 Km outside of MOD land
M&L for vitrified coloured ceramic tiles, 9 to 10 mm thick (Square/rectangular) area of each tile n.exceeding 0.36 sqm in floors/wall etc, set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over 15 mm thick screed bead in CM 1:4, and including dismantling of tiles complete all as specified and directed by Engr-in-Charge. Note : Debris removed from site upto 20 Km outside of MOD land
All as per item No 40 above but as in skirting/ dado etc with and including 10mm thick backing coat in cement mortar 1:4 an wall and including dismantling of tiles complete all as specified and as directed.Note : Debris removed from site upto 20 Km outside of MOD land
S&F in repair stainless steel sink with drainage board made out of 1mm thick sheet for kitchen or laboratory with plug, washer, waste pipe etc including cast iron brackets, connecting union over all size 915mm X 460mm with bowl size 410mm X 330mm X 160mm complete..
S&F in repairs vitreous china wash hand basin of size 550mm x 400mm white, flat back including angle iron brackets with two coats of synthetic enamel paints including PVC waste pipe of 32mm dia of suitable length, PVC connection of 15mm dia & 450mm long with PTMT nuts, and 32mm dia brass waste fitting complete all as specified.
S&F in repair vitreous china squatting pan “orrisa” pattern of size 580mmx440mm “white” with integral foot rest (excluding flushing cistern and flush pipe) incl provision of cement concrete bedding, ‘P’ trap 110mm dia connection to trap and flushing pipe, anti-syphonage complete all as specified and directed by Engineer-in-charge.
S&F in repairs viterious china wash down water closet pan (Pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe)incl P or S trap etc all as specified.
S&F in repair PVC flushing cistern of 10 ltr capacity valveless, symphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including flush pipe of 32mm bore PVC and connection to pipes etc and taking down existing flushing cistern complete all as specified and as directed by Engineer-in-Charge.
S&F of plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete
S&F in repair 32mm bore PTMT waste coupling fixed to waste pipe and wash hand basin complete all as specified and as directed by Engineer-in-Charge.
S&F for 15mm bore PVC connection 450mm long with brass nuts on both ends complete all as specified and directed.
S&F in repair chromium plated shower rose 150 mm size with or without swivel joint and fixed for 15mm bore pipe.
S&F steel in repairs Grating doom 125 mm dia with waste hole or without hole complete all as specified and directed
S&F in repair 100mm bore PTMT sink waste coupling fixed to waste pipe and wash hand basin complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement of PVC waste pipe 75mm long, 32/40 mm bore complete all as specified
S & F in repair PTMT long body bib tap 15mm dia pipe with crutch or butter fly handle screwed down, screwed for iron pipe and fixed
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with putty,complete all as specified and directed by Engr-in-Charge.
Material & Labour for prepration of old plastered or unplastered surfaces of walls and applying exterior two or more coats of APEX/WEATHER over 3mm putty including priming coat of exterior primer applied complete all as specified and directed by Engr-in-Charge.
Preparation of old decorated surfaces of ceiling including brooming , scraping down. Smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with putty complete all as specified and directed.
M&L for prepation of old painted wood based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel Paint, complete all as specified and directed by Engr-in-Charge.
Preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
Taking down frame or Chowkhats with shutters (without taking off shutters from the frames) of any description not exc. 1.50 Sqm each incl necessary repair to opening with CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
Taking down frame or Chowkhats with shutters (without taking off shutters from the frames) of any description exc. 1.50 Sqm not exc. 4.0 Sqm each incl necessary repair to opening with CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
Taking down Door shutter of any description exc. 1.0 Sqm but n exc 2.0 Sqm each incl necessary repair to opening with CM 1:4 complete all as specified and directed.
S&F 30 mm thick Flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides, complete as specified and as directed.
S & F for 35 mm thick factory made, 2nd class hard wood glazed and skeleton shutters open rebeated and prepared to received glass, gauzed, with out sash bar edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of member of shutter as per specified in SSR Part-I Section 8, clause 8.24 (a) and for door and fixed with chowkats, chemically pressure treated complete all as specified and as directed.
S&F for size 105x60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, hold fast, lock strike plate, PCC 1:3:6 in side hollow section & hold fast etc., complete as specified,complete all as specified and directed by Engr In Charge.
S&F for size 125 x 60 mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, hold fast, lock strike plate, PCC 1:3:6 in side hollow section & hold fast etc. complete all as specified and directed by Engr In Charge.
M&L Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide/ zinc chromate complete all as specified and directed by Engr In Charge.
Preparation of new wood and wood based surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet reinforced with M.S. Square tube, complete all as specified.
S&F Factory Made Solid PVC Moulded Door Shutter with Particle Board Core, 28 to 30mm thick (stiles), with 2 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, complete all as specified and directed by Engr -in-Charge
S&F 100 mm Butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed.
S&F 150 mm long Aluminum anodized barrel tower bolts of extructed section complete all as specified and directed.
S&F 100 mm long Aluminum anodized barrel tower bolts of extructed section complete all as specified and directed.
S&F aluminum alloy handles fabricated anodised of 150 mm long complete all as specified and directed. .
S&F aluminum alloy handles fabricated anodised of 100 mm long complete all as specified and directed. .
S&F aluminium alloy, anodised, sliding door bolt of length 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed
S & F galvanised Stainless steel wire cloth of 0.36mm dia wire and average width of aperture 1.4mm & fixed with tacks of stainless steel wire staples,etc complete all as specified and as directed.
Supply and fixing windows/ ventilators fabricated from 0.60mm thick roll formed section made of galvanised steel powder coated (Base steel as per IS-513"D" quality) galvanised as per IS-277 with ZINC of 120GM/SQM . Windows /ventilators having frame suitable for dual shutter i.e. inner and outer shutter with grill, glazed shutter with 4.0mm thick glass, mesh shutter with 32 gauge stainless steel mesh, 6mmx12mm flat iron with 10mm square bar M.S. grill and all fitting, fixtures accessories complete as specified and shown in drawing No CEAF/STD-191/2014, sheet 1/2 & 2/2 dated 11.12.14(4000 series), complete all as specified and direted by Engr-in-Charge. Note : (i) Glazed shutter with 4.00mm thick glass, Mesh shutter with 32 gauge stainless mesh and M.S. grill as per Note above mentioned drawing deemed to be inclusive in the rate quoted for unit. (ii) Glass, stainless steel mesh will be fixed to window by authorised rep of manufacture of window only. (iii) Including 2 coats of synthetic enamel paint over a coat of red oxide complete.
Demolition of cement concrete in sunken portion in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge. Note : Debris removed from site upto 20 Km outside of MOD land
Providing and making fillet of cement concrete in 1:2:4 in sunken portion to maintain the slope towards the spout including applying the under mentioned course of sunkan treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply two coats of acrylic polymer modified elastomeric water proofing coating (mixture of liquid plymer component and a cementitous powder) as per manufacturers instruction to bottom and vertical sides up to finished floor level + 100mm height , the thicknes of each layer shall be 1 mm . when the second lyaer is still, sticky, coarse sand spray shall be carrried for the vertical and bottom surface. Plaster the bottom and sides up to bottom of the sunken slab portion with minimum 10mm thick cement mortar 1 : 4 mixed with integral water proofing compound as per manufacturers specifications including rounding of corners and junctions slopping towards spout. Note:- This treatement shall be done by the approved authorized applicators and guarantee of treatement shall be minimum 10 years complete all as specified and directed by Engr In Charge.
Refilling PCC 1:5:10 type E2 using 40mm stone aggregate, 300mm thick in the sunken with the help of proper tools & equipments & plants complete all as specified and as directed by Engineer-in-Charge.
Providing and making cement concrete in 40mm thickness in 1:2:4 type B0 (12.5mm graded aggregate) including mixing of Dr Fixit Pidiproof LW+. Complete in sunken upto the below level of tiling complete all as specified and as directed by Engineer-in-Charge.
Spply and fix 40mm dia GI pipe as spout in sunkan floors, medium grade etc complete all as specified and as directed.
Dismantling existing tanks capacity exc. 250 ltr but n.exc 500 ltr,and removing.
S&F rotational moulded vertical water storage tanks with closed tops ( cylinderical ) fix hoisted and in position 500 ltr capacity incl disconnecting and refixing the existing GI fitting and pipe complete
S&F of ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed suitable for iron pipe 20mm bore having weight not less than 210 gms complete all as specified.
Dismantling to brick tiles or terracing tiles single layers laid on roof including removing the mudfaska or any type upto 4 storeys building treatment including demolished materials removed from out side defence land complete all as specified and directed by Engineer-in-charge. Note : Debris removed from site upto 20 Km outside of MOD land
M&L for Cement Concrete 1:2:4 Type B-0 (using 12.5 mm graded stone aggregate) as in roof kerb or mud stops rounded of chamfered on edge complete upto 4 storeys building all as specified & Directed by Engr-in-Charge.
M&L for 55mm thick PCC 1:2:4, type B-1 using 20 mm graded stone aggregate laid as in roof padding without using extra cement complete upto 4 storeys building all as specified & Directed by Engr-in-Charge.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves up to 150mm ht of parapet wall etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. (e) Including taking down of existing roof treatment in any description i.e mud faska,bricks tiles ,APP etc. (f) including removing of all demolished material from out of MOD land. (g) including applying two coats of water proofing aluminium paint over APP membrane complete all as directed by Engineer-in-Charge. Note:- This treatement shall be done by the approved authorized applicators and guarantee of treatement shall be minimum 10 years complete all as specified and directed by Engr In Charge.
M&L for removing rotational moulded polyethylene water storage tanks any size or shape or capacity hoisted and refixed in same position including necessary fittings with 20 mm dia Ball brass valves, high pressure, with polythene float and flynut including other fittings complete all as specified and directed by Engr In Charge.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engr In Charge.
S&F for 75 mm dia pvc pipe Stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof as percomplete all as complete all as specified and directed by Engr In Charge.
S&F for 110 mm dia pvc pipe Stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof as per complete all as specified and directed by Engr In Charge.
S&F for PVC SWR bends 110 mm complete all as specified and directed by Engr In Charge.
S&F PVC SWR bends 75 mm complete all as specified and directed by Engr In Charge.
S&F for PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc complete all as specified and directed by Engr In Charge.
All as per item no. 97 above but 75 mm dia..
Supply & fix in replacement of flood light 50 watt, high power LED 3000/6000K energy saving, Highly efficient integral type mid power made of pressure die cast aluminium housing with 10 KV SPD, toughned glass, w/o Lens.IP66, suitable for highlighting architectural features orretail spaces complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of LED Security Light 45 watt, LUMOS-SUPER Highly LED street light made of pressure dia cast aluminium housing with high power LEDs, lens & toughened glass, IP66, light distribution Efficacy>110Lm/W. 5700K. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V . Make:- Havells/Halonix/Polycab or equivalet.
Supply & fix in replacement of flood light 50 watt, high power LED 3000/6000K energy saving, Highly efficient integral type mid power made of pressure die cast aluminium housing with 10 KV SPD, toughned glass, w/o Lens.IP66, suitable for highlighting architectural features orretail spaces complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of LED Security Light 45 watt, LUMOS-SUPER Highly LED street light made of pressure dia cast aluminium housing with high power LEDs, lens & toughened glass, IP66, light distribution Efficacy>110Lm/W. 5700K. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V .
S& F in replacement sub main wiring with two single core PVC insulated unsheathed cable 1100 volts FRLS grade with multi strand copper conductor and drawn through and including PVC conduit along with continuous earthing wire but in green colour complete on surface/concealed and connected to common earth dolly of the following size. Note : Three run of PVC cable and one run of PVC conduit shall be measured as one unit length. (a) 4 Sqmm ( 2 single run of 4 Sqmm and one run of 4 Sqmm as earth wire)
All as per item no.103 above but 6 Sq.mm ( 2 single run of 6 Sqmm and one run of 6 Sqmm as earth wire)
Supply & fix in replacement of MCCB four Pole 125 Amps, 415 volt thermal release bearing cap 16 KA comlete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of MCCB four Pole 100 Amps, 415 volt thermal release bearing cap 16 KA comlete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of MCB TP, 100 Amps, 10 KA 440 volt 50 Hz all as specified ans directed by engineer in- charge.
S&F of LED ceiling light 34 watt 2x2 recess LED, 6000 K luminaire having glare free symmetrical illumination Complete all as specified and directed by Engineer-in-Charge.
Maintenance and general servicing 'B' Check of DG sets of following capacities of any make including replacing of Engine Oil, oil filter, fuel filter, air Filter, fuel hose, water separator, By-pass filter, air cleaner and topping up of coolant etc. complete including general cleaning including cleaning of accoustic enclosures of DG set with the help of air blowers complete and if required replacing of O ring,nut, bolt,washers etc complete all as specified and as directed by the Engineer-In- Charge. (a) 400 KVA DG set
160 KVA DG set
140 KVA DG set
125 KVA DG set Note : (i) The work shall be executed only though authorised service provider of OEM of respective DG set. The contractor has to submit MOU with the authorised service provider duly noterised and uploaded at the time of submission of bid documents. (ii) The authorised service provider shall give his complete investigation report of respective DG set seperately on his first visit to each DG set including the complete details of repairs to be carried out with warrantee of 2 years for parts replaced by authorised service provider of OEM. (iii) No repair work other than essential repair work indicated in the investigation report of the service provider for respective DG set will be carried out. (iv) The rate quoted for BOQ item Nos. 109 to 112 include supply and fixing of carbon brush set with holder, solenoid switch assembly with bush, commuter unit, stator starting and running coil.
Disconnecting all electrical cable connections from the dynamo assembly and taking down the dynamo assembly for carrying out repairs and complete overhauling the system including replacing the unserviceable parts like Carbon brushes, Bearings, Armature. Burnt out coils etc. reassembling and re-fixing the dynamo assembly to its original position and reconnect all disconnected cable connections including testing complete for the following capacities of DGs complete all as specified and as directed by the Engineer-In- Charge. 400 KVA DG set
160 KVA DG set
140 KVA DG set
125 KVA DG Note : The work shall be executed only though authorised service provider of OEM of respective DG set. The contractor has to submit MOU with the authorised service provider duly noterised at the time of submission of bid documents.
Supply & Fix 24 Volts 30 Amps battery Charger, panel mounting type including removing the unserviceable battery Charger from the existing position complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in repair lead acid maintenance free batteries 180 AH, 12 V, 25 plates complete all as specified and as directed by the Engineer-In- Charge.
Supply and connect maintenance free lead acid battery 12 Volt, 150 AH complete all as specified and as directed by the Engineer-In- Charge.
Draining out the fuel from the fuel tank of DG Set of various capacity and keeping it in separate container, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, cleaning the fuel tank both internally and externally by removing all the accumulated dust / sediments, leak testing the tank and welding / brazing if required and re-fixing the tank to its original position, replacing the drain plug and PVC pipe protected with steel flexible pipe, calibrating the fuel tank, refilling the drain out fuel back into the tank and provision of locking arrangements complete all as specified and as directed by the Engineer-In- Charge.
Repairs to radiator of copper/aluminium all types taking out by disconnecting from DG set locating the leaking places and trnasposting to workshop for soldering / brazing complete including cleaning with acid and refixing in position complete all as direcetd incl replacement of hoses with new one for DG sets of capacity 125 KVA complete all as specified and as directed by the Engineer-In- Charge.
Repairs to radiator of copper/aluminium all types taking out by disconnecting from DG set locating the leaking places and trnasposting to workshop for soldering / brazing complete including cleaning with acid and refixing in position complete all as direcetd incl replacement of hoses with new one for DG sets of capacity 140/160KVA complete all as specified and as directed by the Engineer-In- Charge.
Repairs to radiator of copper/aluminium all type taking out by disconnecting from DG set locating the leaking places and trnasposting to workshop for soldering / brazing complete including cleaning with acid and refixing in position complete all as direcetd incl replacement of hoses with new one for DG set of capacity 400 KVA complete all as specified and as directed by the Engineer-In- Charge.
Disconnecting and taking down the defective / unserviceable DC wiring and rewiring with same size of cable including supply and replacing of complete wire with flexible pipe, control cable including testing complete for following capacities of DG Set complete all specified and directed by engineer- in- charge :- 400 KVA DG set
160 KVA DG set
140 KVA DG set
125 KVA DG set
M&L for servicing of AMF panel of DG set of capacity 125 KVA cleaning of AMF panel, rectification of defect rewiring replacement of D/S indicator,fuse, timer. and new indicator of complete AMF panel and replacement of unserviceable relays under respective item of this schedule complete all as specified and as directed by the Engineer-In- Charge.
M&L for servicing of AMF panel of DG set of capacity 160/140 KVA cleaning of AMF panel, rectification of defect rewiring replacement of D/S indicator,fuse, timer. and new indicator of complete AMF panel and replacement of unserviceable relays under respective item of this schedule complete all as specified and as directed by the Engineer-In- Charge.
M&L for servicing of AMF panel of DG set of capacity 400 KVA cleaning of AMF panel, rectification of defect rewiring replacement of D/S indicator,fuse, timer. and new indicator of complete AMF panel and replacement of unserviceable relays under respective item of this schedule complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of digital multi function meter to read voltage, current and power factor including set of CT-1 each complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of 3 pole power contactor MNX 185 , 185 Amps complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of 3 pole power contactor MNX MNX 300 , 300 Amps complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of 3 pole power contactor MNX 225, 225 A complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement of solenoid switch suitable including all necessary arrangement complete all as specified and as directed by the Engineer-In- Charge.
Supply and replace engine oil from engine oil sump with suitable grade oil SAE-20W40 complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement self starter for suitable of 125 KVA DG set capcity including all necessary electrical connections complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement self starter for suitable of 140 KVA DG set capcity including all necessary electrical connections complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement self starter for suitable of 160 KVA DG set capcity including all necessary electrical connections complete all as specified and as directed by the Engineer-In- Charge.
Supply & Fix in replacement self starter for suitable of 400 KVA DG set capcity including all necessary electrical connections complete all as specified and as directed by the Engineer-In- Charge.
S&F in repair fan belt with provided new fan belt DG set pf capacity 125- 160 KVA complete all as specified and as directed by the Engineer-In- Charge.
S&F in repair belt for water pump ( set ) in 125/160 KVA DG set for greevs complete all as specified and as directed by the Engineer-In- Charge.
S&F in repair belt for belt water pump ( set ) in 400 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
M&L for locating fault in LT/HT (1.1/11 KV grade) underground cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 400 Sqmm 3.5 core/ 300 sq mm 3 core. The fault locating equipment will be brought to site within 02 hours of instruction received from Engineer-in-Charge complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement aluminium Tube terminal ( thimbles) of size 50 to120 Sqmm XLPE Cable complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement aluminium Tube terminal ( thimbles) of size 150 to 240 Sqmm XLPE Cable complete all as specified and as directed by the Engineer-In- Charge.
M&L for de-scaling / Servicing of radiator unit of DG set capacity 125 to 400 KVA including draining water, filling & circulating chemical and flushing complete including minor spare as inlet and outlet hose pipes of required size, jublee clamps etc as required complete all as specified and as directed by the Engineer-In- Charge.
S & F in repair of PT fuel pump by dismantling, transporting, repairing and calibration, testing and commissioning of PT fuel pump for 125 KVA DG set including the replacement of all service kits, pulsvation damper, tacho drive shaft and seal, gear drive shaft , bearing, weight carriers, etc complete all as specified and as directed by the Engineer-In- Charge.
All as per item No. 148 above but of capacity 140 KVA complete all as specified and as directed by the Engineer-In- Charge.
All as per item No. 148 above but of capacity 160 KVA complete all as specified and as directed by the Engineer-In- Charge.
All as per item No. 148 above but of capacity 400 KVA complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix oil safety switch to engine of 160/140/125 KVA DG set as per existing complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix oil safety switch to engine of 400 KVA DG set as per existing complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement the corrosion resistor as per existing to the Engine of DG set capacity 160 & 125 KVA complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement gear tachometer for DG set of capacity 125. 140 & 160 KVA as per existing complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement exhaust manifold set of three pieces complete with gaskets , stud mountings, nuts etc complete ( centre , rear and front) in 125/140/160 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
M&L for repair including replacement of coils , bush/ bearings and other spares as required to alternator/dynamo unit of DG set of capacity 125/160/200 KVA complete all as specified and as directed by the Engineer-In- Charge.
M&L for carry out the tappet setting after opening the top cover to DG set capacity 125/140/160 KVA including replacement of gasket and minor spares as required complete all as specified and as directed by Engineer-in-charge.
M&L for carry out the cylinder head servicing including servicing of valves intake, valve exhaust, guide valve, insert valve seat, pin guide, collet valve, lapping, replacement of gasket for 125/160 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
M&L for repair the water pump of DG set 125 KVA including replacement of impeller, ball bearing, shaft, spacer, plug and seal complete all as specified and as directed by the Engineer-In- Charge.
M & L for asbestos rope 12 mm dia for wrapping the exhaust pipe of DG set complete all as specified and as directed by the Engineer-In- Charge.
S&F in repair Air filter suitable for 125/160 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
M & L for repair and reconditioning the starting motor of kirloskar / cummins / Greaves make including taking out the defective starter from 125 KVA /160/140 KVA / capacity DG set , complete dismantling and repair and replacing the carbun brushes with holder, solenoid switch assly, bush, commutator unit, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing complete all as specified and as directed by the Engineer-In- Charge. Note : Rate quoted shall be for removing , refixing incl overhauling of starter & spares parts required will be measured and paid separately as supply ony under respective item.
M & L for repair and reconditioning the starting motor of kirloskar / cummins / Greaves make including taking out the defective starter from 400 KVA / capacity DG set , complete dismantling and repair and replacing the carbun brushes with holder, solenoid switch assly, bush, commutator unit, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge Note : Rate quoted shall be for removing , refixing incl overhauling of starter & spares reqd will be measured and paid separately as supply only.
M & L for taking down stator assembly of alternator by disconnecting electrically and mechanically taking to work shop for rewinding incl removing burnt coils, insulating material complete cleaning with CTC and rewinding with same gauge ISI marked winding wire complete with ISI marked insulating paper and Dr Beck varnish baking / heating and bringing back to installatin refixing , connecting elecrtically and mechanically and testing on completion of work complete all as directed for DG set of capacity 140/160 KVA/ 125 KVA complete all as specified and as directed by the Engineer-In- Charge.
M & L for taking down stator assembly of alternator by disconnecting electrically and mechanically taking to work shop for rewinding incl removing burnt coils, insulating material complete cleaning with CTC and rewinding with same gauge ISI marked winding wire complete with ISI marked insulating paper and Dr Beck varnish baking / heating and bringing back to installatin refixing , connecting elecrtically and mechanically and testing on completion of work complete all as directed for DG set of capacity 400 KVA complete all as specified and as directed by the Engineer-In- Charge.
S & fix solid state potentiometer under cummins part no. 3877372 in 125/160/400 KVA and testing complete all as specified and as directed by the Engineer-In- Charge.
Supply only coolant for radiator suitable for DG set 125/140/160/400 all as per manufacturers recommendations and complete all as pecified and as directed by the Engineer-In- Charge.
S & F start and stop relay 12 V/24 V DC suitable for AMF Panel capacity of 125/140/160/400 KVA all as per manufacturers recommendations and complete all as specified and as directed by the Engineer-In- Charge.
S & Fix in repairs Lub oil pressure transducer make Cummins Part no.3392445 in 140/160 KVA DG set and connecting with DG set system all as per manufacturers recommendations complete all as specified and as directed by the Engineer-In- Charge.
S & Fix in repairs Low lub oil pressure safety make Cummins Part no.3408609 in 125/140/160 KVA DG set and connecting with DG set system complete all as specified and as directed by the Engineer-In- Charge.
S & Fix in repairs High water temperature trip safety make Cummins part no.3408624 in 160 KVA DG set and connecting with DG set system complete all as specified and as directed by the Engineer-In- Charge.
S & Fix in repairs harness wiring make Cummins part no. 3056356 in 140/160 DG set and connecting with DG set operating system complete all as specified and as directed by the Engineer-In- Charge.
S & Fix in repair shutdown valve under make Cummins part no. 3239599 in 125/160 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement Lub oil hoses set complete for DG set of capacity 160 complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement Lub oil hoses set complete for DG set of capacity 125/140 KVA complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement DG set control panel into Digital electronic control panel with mounting bracket with vibration isolating pads -3 nos. complete part no. 4083935 of Cummins suitable for DG sert 400 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix in replacement DG set control panel into Digital electronic control panel with mounting bracket with vibration isolating pads -3 nos. complete of Cummins suitable for DG sert 125/140KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
S & Fix in repair Engine wiring harness under Cummins part no. 4053886 in 125/140/160 KVA DG set complete all as specified and as directed by the Engineer-In- Charge.
S&F Actuator unit make: Cummins Part no.3408324 in PT fuel pump of 125/160 KVA DG set at , in the engine and testing on load complete all as specified and as directed by the Engineer-In- Charge.
S&F Housing actuator under Cummins Part no.3166630 in 140/160 KVA DG set by taking out old from fuel pump, fixng the new housing actuator complete all as specified and as directed by the Engineer-In- Charge.
Supply, installation and commissioning of radiator for 200 KVA Cummins DG set under Cummins Part no. 4020300 including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet complete all as specified and as directed by the Engineer-In- Charge.
Supply, installation and commissioning of radiator for 140/160 KVA KVA Cummins DG set under Cummins Part no. 4020300 including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet complete all as specified and as directed by the Engineer-In- Charge.
Supply, installation and commissioning of radiator for 125 KVA Cummins DG set under Cummins Part no. 4020300 including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet complete all as specified and as directed by the Engineer-In- Charge.
Supply, installation and commissioning of radiator for 140 KVA Cummins DG set under Cummins including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet complete all as specified and as directed by the Engineer-In- Charge.
Labour charges for disconnecting the engine from the coupling, dismantling the Cummins engine 400 KVA water cooled engine cylinder heads, cylinder liner, pistons & connecting rod, injectors, intake and exhaust manifolds and its connected accessories, thorough cleaning and inspection of all removed parts for accessing the servicability, carrring out repair in the engine by replacing the defective / worn out parts, reassembling the engine, carryingout engine valve and injector settings, fixing all removed parts, starting, testing and commissioning complete all as specified and as directed by the Engineer-In- Charge.Note : Parts required to be replace shall be measured and paid seperately.
Complete dismantling of cylinder head assembly of Cummins DG set engine 160 KVA, carry out repair and reconditioning by renewing the defective parts / wornout items and reassembling the same, carrying out vaccum testing and calibrating the head, fixing and testing in the engine complete all as specified and as directed by the Engineer-In- Charge.
Complete dismantling of Injector assembly of Cummins DG set engine 400 KVA, carry out repair and servicing by renewing the defective parts / wornout items of barrel and plunger, injector cup, and reassembling the same , calibrating the injector and adjusting the spray pressure timing as per the engine capacity, fixing and testing in the engine complete all as specified and as directed by the Engineer-In- Charge.
Complete dismantling of turbo charger assembly of Cummins DG set engine 400 KVA, carry out repair and servicing by renewing the defective repair kit, checking the wheel ad shaft balancing, reassembling the same, fixing and testing in the engine complete all as specified and as directed by the Engineer-In- Charge.
M/S MG GROUP
Laxmi traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .