Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.8 L+₹44,670 (1.57%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹29.4 L+₹99,736 (3.51%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹33.2 L+₹4.9 L (17.1%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹34.6 L+₹6.2 L (21.8%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹45.0 L
EMD Value
₹89,960
Closing Date
9 Nov 2024, 6:00 pmClosed
GE (SB) KARWAR
GE (SB) KARWAR
REPR/MAINT OF STP-II,STP-MAP AT LITTLE BINAGA INCLUDING SLPH-01 ND SLPH-02 AT AMDALLI ND REPR/MAINT OF INTERNAL ELECTRIFICATION, FITTINGS, FIXTURES AT WM-22 AND WM-23 BUILDING INCLUDING ROUTINE MAINTENANCE OF WM-24,WM-25,WM-26,WM-27,WM-28 BLD KWR
2024_MES_678523_1
8238/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (SB) KARWAR
₹89,960
Yes
10 Jan 2025
8 Oct 2024
11 Nov 2024
8 Oct 2024
9 Nov 2024
24 Oct 2024
8 Oct 2024 - 22 Oct 2024
Amount
M&L for Cleaning of Bar screen chamber tank at STP Map by pumping out raw sewage, removing the sludge settled at the bottom, cleaning thoroughly with wire brush, finally cleaning with dilute solution of sodium hypochlorite & fresh water including writing letters on the tank with synthetic enamel paint as "TANK CLEANED ON ------(DATE) AND DUE ON ---DATE with 10 cm high stencil cut English letter all as specified and directed.
All as per item No 1.00 herein before, but for Oil and Grease removal tank at STP Map.
All as per item No 1.00 herein before, but for Collection equilisation tank at STP Map.
All as per item No 1.00 herein before, but for Biological decomposition (MBBR) tank at STP Map.
All as per item No 1.00 herein before, but for Settling tank at STP Map.
All as per item No 1.00 herein before, but for Chlorination tank at STP Map.
All as per item No 1.00 herein before, but for filter feed tank at STP Map.
All as per item No 1.00 herein before, but for Equilization tank at STP-2.
All as per item No 1.00 herein before, but for SLPH-I at Amdalli.
All as per item No 1.00 herein before, but for SLPH-II at Amdalli.
M&L for cleaning including preparation of old steel surface exceeding 10 cm width or girth and painting with one coat of synthetic enamel paint on machineries / equipments / filters /motors /pumps /compressors/ ladders/ walkovers/ pipelines/ cable trays/switch boards, panels and any other parts connected to STP-MAP with paint of approved colour using spray gun complete all as specified and directed.
All as per item No 11.00 herein before, but for STP-2.
All as per item No 11.00 herein before, but for SLPH-1 & SLPH-2 at Amdalli.
M&L for cleaning of Rotating biological contactor unit and Lamella separator unit of cpacity- 170 cum/day make of Plastique metal technology by removing the sludge/raw materials on the rotating disc and settled at the bottom, cleaning thoroughly with wire brush, finally cleaning with dilute solution of sodium hypochlorite & fresh water on once in yearly including preparation of surface and painting with one coat of synthetic enamel paint as per existing colour complete all at STP-II as specified and directed.
M&L for, Opening / checking and servicing the LT Panel board cubical type for pumpset located in STP-MAP, STP-II & SLPH 1 & 2 at Amdalli, cleaning the bus duct chamber, inspect the complete panel, tighten the nuts & bolts of incoming, outgoing MCCBs/SFU of different capacity and cleaning/removal of moisture with CRC electrical parts cleaner, applying thick coating of Z931 strippex B and Z 955 strippex (SL) high temperature tape for preventing from flash over & fire hazard including replacement of 3mm thick gasket, Burnt copper wire as per existing, connectors ,MCBs, Relays, closing of all holes and changing of the same complete all as specified and as directed. Note : The quoted rate deemed to be included the nut & bolts, washer and similar items required for proper functioning of the LT Panel board.
M & L for dismantling, transportation, servicing , refixing and testing of air compressor of capacity 220 m3/hr, RPM 760, pressure rating 0.6 kg/cm2 (Twin Lobe type Air Blower ) at STP MAP, Make : Everest through qualified service engineer/OEM including removal of old oil & filling of new oil upto required level in sump, replacement of gasket, bearings etc incl replacement of the old unsv filter assembly with the new filter assembly, minimising the vibration of the blower, rectifying the air leakages if any persists in the system by rectifying the defects, making the allignment of the blower assembly with the motor alongwith V belt for allignement between bower and motor pulleys all as specified and directed. Note: a) The oil for blower is to be measured as and paid seperately. b) All the minor parts required for the reapir to blower assebly, filter assy, pulleys and allignment between the blower and motor is incl in the above quoted rate.
M&L for Lifting up submersible raw sewage pump set of capacity 3 HP to 7.5 HP cast iron body of any make from sewage sump / equalization tank at STP-2 and SLPH 1 & 2 at Amdalli, including disconnected pipe connection/delivery lines, nuts, bolts, washer etc for repair/replacement of unserviceable spare parts including transportation to the workshop and re-installing including welding work the same after repair & testing all as specified and as directed.
M&L for General overhauling/inspection of impeller, shaft all bearings and sleaves, of the submersible raw sewage Lift pump 5 HP to 7.5 HP, Make: Kirloskar, of SLPH-01 & 2 at Amdalli and re-installation of Pump after replacing all sleaves, bearings,seals and with SS nut bolts, metalising the shafts and re threading bottom plate by lathe work including body repairs, welding works and complete testing all as specified and as directed.
Discription all as per item No 18.00 above herein before, but Pumps having capacity of 1 HP to 3 HP.at STP 2 complete all as specified and directed.
Discription all as per item No 18.00 above herein before, but Raw sewage self prime centrifugal /monoblock pumps having capacity of 12.5 m3/hr at STP-Map complete all as specified and directed.
Discription all as per item No 18.00 above herein before, but Filter feed centrifugal/monoblocke pumps having capacity of 13.64 m3/hr at STP Map complete all as specified and directed.
Discription all as per item No 18.00 above herein before, but sludge feed centrifugal/monoblocke pumps having capacity of 1 m3/hr, 30 m head at STP-Map complete all as specified and directed.
M&L for decoupling electric motor (SCIM) of capacity upto 3 HP from monoblock/centrifugal pumps/Air compressor / RBC of any make, opening the motor, cutting/removing the existing burnt winding and rewinding using super enamelled copper wire of suitable gauge to match with the existing winding including replacing sleeves, cotton taps etc, varnishing the winding by keeping in hot oven for drying to attain required insulation resistance & replacing ball bearing, re-assembling the motor and refixing the same in original position, testing etc complete all as specified and as directed.
All discription as per item No-23.00 here in before, but having capacity of 5 HP complete all as specified and directed.
All discription as per item No-23.00 here in before, but having capacity of 7.5 HP complete all as specified and directed.
All discription as per item No-23.00 here in before, but having capacity of 12.5 HP complete all as specified and directed.
M & L for opening of Dual media filter (DMF) at STP Map having size of 1.1 meter dia and 1.6 meter height after closing all inlet and outlet valves and removing old dirty sand media with old nut & bolt/gasket/washer from filter chamber and cleaning complete chamber, drying, preparation of surface and applying two coats of synthetic enamel paint using spray gun and filling of new sand media as per standard procedure, fixing new old nut & bolt/gasket/washer etc complete all as specified and as directed. Note :Filter media required shall be measured and paid separately.
All discription as per item No-27.00 here in before, but Activated carbon filter (ACF) media having dia of 1.2 mtr and 1.8 mtr height complete all as specified and directed.
S & F in repairs HRC fuse links cylindrical type 2-32 amps size 14 x 51 suitable for type FN 32 / FNX 32 / S-D-F & for HCO 32 fuse base all as specified and as directed. Make : L&T Cat No: SF90142 or equivalent make in Siemen / Schnieder /ABB/Legrand
S & F in repairs HRC fuse links cylindrical type 63 amps size 14 x 51 suitable for type FN 63 / FNX 63 S-D-F & for HC 63 fuse base all as specified and as directed. Make : L&T Cat No: SF90159 or equivalent make in Siemen / Schnieder /ABB/Legrand
S&F in repairs HRC fuse links DIN type 125 amps size suitable for type FA-C 100 & for HB 160 Fuse base all as specified and as directed. Make : L&T Cat No: SF94030 or equivalent make in Siemen / Schnieder /ABB/Legrand
S & F in repair single phase preventer relay having system supply voltage -415 V AC Three phase +/- 10% , complete all as specified and directed. Make : L&T / Schnieder /ABB/Legrand
Supply and fix in repairs V belt B-47 for 12.5 HP air blower all as specified and directed. Make- Fenner/Dunlop
Supply and laying, PVC insulated flexible industrial, Unarmoured copper cable 4 core, 6 sqmm for voltage grade up to 1100V, including taking down of old existing one all as per site requirement as per IS 694:1990 complete all as specified.
All discription as per item No 34.00 here in before, but cable having size of 4 core, 10 sqmm complete all as specified and directed.
Taking down old existing DI pipes and Supply , laying new DI pipes Class “K-9” heavy grade with all fittings and joints laid in floors or fixed to walls and ceilings etc.in sewage treatment sump of size 150 mm complete all as specified and as directed.
All discription as per item No 36.00 here in before, but DI Pipe having dia of 100mm complete all as specified and directed.
Taking down old unserviceable pressure gauges from sewage line and supply and fix pressure guages size up to 6'' suitable for pressure rating PN 16 complete with syphons and components & fittings made out of SS suitable for sewage line including testing all as specified and as directed.
Taking down old unserviceable and Supply and fixing of love joy coupling of existing model pump motor unit capacity up to 5.5 KW by changing of motor position, including gas cutting welding, refitting and aligning of the same complete all as specified and as directed.
M&L for Repairs and overhauling of existing gate valve of 200/100 mm including replacement of brass lock nuts, repairs to spindle and wheel, washers, rings SS nuts and bolts, gaskets including removing and refitting metalising on sewage lines including one coat of primer and two coats of epoxy paint complete all as specified and as directed.
Supply and changing of Granular fine pebbles of size 40mm to 3mm match to existing size and shape suitable for filter media of rapid sand water filters free from all types of salts, alkaline materials, minerals, silts, impurities etc complete all as specified and as directed.
Supply and changing of quartz/silica sand all as per existing suitable for dual filter complete all as specified and as directed
Supply and fix in repairs Three Phase Fully-Automatic Star-Delta Starter in Sheet-Steel Enclosure suitable for capacity 12 HP, 415V AC 3-Ph Motors (Motor Rating AC-3 duty) conforming to IS13947 (Part 4) & IEC 60947-4 for submersible sewage pump of SLPH and STP-2 of Make : L&T model No.MN 45F or equivalent make of Crompton/BHEL/Schneider including taking down old unserviceable starter panel of any description and in any position complete all as specified and as directed.
M & L for cleaning of four Nos dry bed tank at STP-II by out raw materials, removing the dry sludge settled at the bottom, cleaning thoroughly with wire brush, finally cleaning with dilute solution of sodium hypochlorite & fresh water on once in yearly, applying one coat of bituminous paint including writing letters on the outer surface of the tank with synthetic enamel paint as "TANK CLEANED ON ------(DATE) AND DUE ON ---(DATE) with 10 cm high stencil cut english letter all as specified and directed.
Taking out old unsv bearing and Supply and fix new bearing suitable for rotating shaft of rotating biological contactor of 170 cum/day capacity at STP-II, as exisiting size complete all as specified and directed.
Taking out old damage shaft and Supply and fix new rotating horizontal shaft of 9'' dia, 7.5 feet length, made of solid stainless steel suitable for stacks of rotating disks of rotating biological contactor of 144 cum/day capacity as exisiting dia/size and length including all require accessories complete all as specifies and directed.
Taking out old damage coupler and supply and fix CI Shaft Coupler of 26'' dia made of stainless steel suitable for rotating biological contactor at STP-II, as per existing place complete with accessories all as specified and directed.
Taking out old damage/unsv and supply and fix star type flexible rubber coupling suitable for CI Shaft Coupler of 26'' dia made of stainless steel suitable for rotating biological contactor at STP-II, as per existing place complete with accessories all as specified and directed.
Taking out existing unsv and supply, fixing and testing in replacement new electromagnetic flow meter as per model 151 MFM WR4200NO1502D1161428P having sensor size 150 MM (Qty-01 No) and as per model 151 MFM WR4200NO1002D1161428P having sensor size 100 MM (Qty-01 No) accuracy class & display + 0.5% of measured flow with rated pressure 10 Kg/Sqcm, sensor factor 0.84, electrode made out of SS 316 materials, including the nuts, bolts, indicater convertor : remote, field mounted, stabilizer, cable, sensor, sensor lining etc and refixing the same in original position for STPs, complete all as specified and as directed.
Supply and fix in repair heavy duty flexible hose pipe 50 to 63 mm dia, 6 bar maximum working pressure green type with swivel cuff at STPs, all as specified and directed.
Supply & fixing in repair of Casing assembly of pumps up to 5HP capacity installed at STPs complete accessories all as specified and directed by Engr-in-charge.
Supply & fixing in repair of Casing assembly of pumps 7.5HP capacity installed at STPs complete accessories all as specified and directed by Engr-in-charge.
Taking out old unsv pipe and Supply, Installation, Testing and Commissioning High density polyethylene Pipes 160 mm dia, in replacement for STPs, with plain socket suitable for solvent cement jointing & fittings, Cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. complete all as specified and directed. Make: Supreme /Astral /Finolex
Taking out old unsv pipe and Supply, Installation, Testing and Commissioning uPVC pressure Pipes 63 mm to 100 mm dia, Class 5, in replacement for STPs, with plain socket suitable for solvent cement jointing & fittings, Cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. complete all as specified and directed. Make: Supreme /Astral /Finolex
All discription as per item no 54.00, here-in before, but pipe having size of 160 mm dia complete all as specified and directed.
Supply and fix in repairs 3 phase starter suitable up to 5 HP motor with soft on/off push botton, selzers switch, relay rating 13-22 Amp, digital voltmeter, indication lamp, wall mounted including connected accessories for STPs, all as specified and direted.
Supply and fix in repairs 3 phase starter suitable of 7.5 HP /5.5 KW motor with soft on/off push botton, selzers switch, relay rating 13-22 Amp, digital voltmeter, indication lamp, wall mounted including connected accessories for STPs all as specified and direted.
M&L for complete overhauling of elctro magnetic chemical metering pump, capcity- 2 LPH model -A10 ,Max pressure- 10.0 kg/cm2, at STPs, for general inspection fuse, manual speed control switch, foot valve, ring seal, ball, tubing connection and antisyphon valve including minor repair and re-installation of Pump and complete testing all as specified and as directed.
Supply in repair rectangular type syntenx loft water tank of 500 lts capacity mounted on floor with 200 mm dia manhole cover all as specified and directed.
Taking out unsv and supply and fix in repair PVC ball valve of 63 mm dia with complete fitting for STP all as specified and directed.
Taking out unsv and supply and fix in repair PP flanged ball valve of 63 mm dia with complete fitting for STP all as specified and directed.
Dismantling and taking down old unsv and supply and fix pvc flexible 3 core, 2.5 sqmm copper cable heavy duty through or on pole connecting to cable looping box of street light fitting complete all as specified and directed by Engr-in-charge.
All discription as per item No 62.00 here-in-before, but having size of 4 core, 2.5 sqmm complete all as specified and directed.
Supply and fixing in repairs Multistranded Flat Three Core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694 HSN CODE: 8544 of following sizes for STP-
(i) 2.5 Sq mm 3 core
(ii) 2.5 Sq mm 4 core
Supply and use calcium hypochlorite (stable bleaching powder/high strength bleaching powder) appearance should be dry, free flowing and free from lumps, should not include substances beyond acceptable limit as given in IS 105000(2012) in treated and disinfected water, available chlorine should be 65% stability loss of chloride on basis of available chloride max 1/15 particle size (passing throung 1.70 mm IS sleeve min 99.5% water insoluble matter 6%, calcium hydroxide maz 4%, sodium chloride max 15% in 20-45 Kg plastic drum packing for STPs, complete all as specifiied and directed by Engr in charge. Note:- The contractor shall submit alongwith supply of material purchase vouchers test certificate for chemical composition and its expiry date etc and other relevant documents supply of chemical shall not be accepted without production of these documents and no payment released.
Supply and use of Alum sulphate confirming to IS complete all as specified and directed by Engr-in-charge.
Supply and topping Gear oil of high quality having grade HP-90 all as specified and directed.
Supply and topping lubricating oil suitable for lubrication of the beraing housing assembly of air blower/non clog centifugal pumps of different capacities installed at STPs having grade of 20/40W all as specified and directed.
Supply and fix in repairs bearing No 6208 2Z/6308 2Z/6204 2RS/6306 2Z/6205 2Z/6310 2Z suitable for pumpset at STP complete all as specified and as directed.
M&L for repair to Gear assembly and general overhauling/inspection of the slow speed mixer (100 RPM), dosing pump capacity of 3 phase, 0.37 KW make of aqua system including replacement of the minor parts if required, i.e. Chain assembly, gears of different sizes, dismantling of motor and shaft, reconditioning of socket, replacement of bearings, coupling joints repair to the shaft of the gear motor assembly, making the allignment of the motor shaft and gear, refixing the motor with the gear assembly at STP complete all as specified and directed.
Taking down carefully existing old unserviceable street/roadway/flood light fitting of any type/size from poles/bldgs of any type at STPs deposit the same to MES store/Sub Station where directed for repair/reuse/credit complete all as specified & directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant for STPs including thermal management in multiple optics complete with IP 65/66 protection including making necessary connection complete all as specified and directed. Make :- Havells /Crompton /Bajaj or as approved by GE.
Taking out old unsv valve and supply and fix cast iron sluice valve of 100 mm dia, PN 1.6, flanged end complete fitting at STPs, as per existing including gasket, nut/bolts, washer all as specified and directed.
All discription as per item no 73.00 herein before, but having size of 80 mm dia complete all as specified and directed.
All discription as per item no 73.00 herein before, but having size of 50 mm dia complete all as specified and directed.
Taking out old unsv valve and supply and fix in repair new NRV cast iron sluice valve of 50 mm dia, PN 1.0 flanged end at STPs, as per existing including gasket, nut/bolts, washer complete all as specified and directed.
All discription as per item no 76.00 above herein, but having size of 100 mm dia.
Taking down old unserviceable CI butter fly valve of any make and size and supply and fixing CI Butter fly valve slim seal design with nitrile rubber lined seat with clutch lever (P10) of size 100 mm flanged end conforming to IS complete all as specified and as directed.
All as per item No- 78.00 here in before, but valve having size of 150 mm complete all as specified and directed.
All as per item No- 78.00 here in before, but valve having size of 50 mm complete all as specified and directed.
Taking down old unserviceable steel structures and M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint for existing beam for SLPH 1&2 & STP-2, STP Map, in any shape or size complete all as specified and as directed.
M&L for cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in support of, foundation and hard standing, finishing surfaces even and fair without using extra cement all as specified and as directed.
M&L cement concrete 1:3:6, type B-1 (using 20 mm graded crushed stone aggregate) as in support of, foundation and hard standing, finishing surfaces even and fair without using extra cement all as specified and as directed.
Taking down/out old unsv GI Tube of any size including all connected accessories complete all as specified and as directed.
Supply and fix in replacement, GI Tubing 100 mm dia, medium grade as per existing including all fittings like gasket, nut/bolt, bends, joint, reducer, coupler for STP complete all as specified and directed.
All as per item No- 85.00 here in before, but tube having size of 80 mm complete all as specified and directed.
All as per item No- 85.00 here in before, but tube having size of 50 mm complete all as specified and directed.
All as per item No- 85.00 here in before, but tube having size of 40 mm complete all as specified and directed.
Taking out old unsv cable and supply and fix in repair , XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm x 3.5 core laying in trenches/wall/floor etc. complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil all as specified and directed.
Returning, filling in soil including spreading leveling, watering and well ramming in layers not exceeding 25cm thick all as specified and directed.
Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Supply and spread dry river sand in trenches for cable cushioning all as specified in clause 19.75 of SSR Part-I. Note:- Punned thickness of sand only will be measured & paid
Supply and laying un-reinforced pre-cast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
S& F in repair LT Feeder pillar made out of 2 mm thick CRCA sheet and mounted on angle iron frame of size 65x65x6mm and 450mm high (indoor type) weather/dust proof, factory made, IP-54 with openable shutters on both sides front and rear having locking arrangements, totally enclosed weather proof, powder coated over a coat of primer suitable for 440V, 3 Phase, 4 wire 50 C/s, aluminium bus bar of of suitable size and capacity, AC supply, electrically connected as per norms and fitted including connecting up all out going MCCB/MCB with suitable size of Aluminium bus bar or with stranded copper cable and fixing on suitable 'U' shaped PCC platform comprising of the following accessories complete all as specified and directed by Engr in charge : Note: The panel should be procured through CPRI approved manufacturer and CPRI type test certificate should be produced during execution of work. (i) Aluminium bus bar with proper colour code -04 Nos, 600 Amp Cap duly fixed on suitable size insulator, nuts bolts etc complete as per OEM recommendations. Incomer Breaker (ii) MCCB 4 Pole 400 Amps.- 01 No Outgoing breakers (iii) MCCB 4 Pole 250 Amps -01 No
M&L in replacement earthing complete with galvanized cast iron earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of earth plate not less than 1.5 m below normal ground level connected to galvanized strip 32x6 mm size as earth lead by means of bolts, nuts washers and check nuts of steel/ GI duly protected with 15 mm bore light grade pipe upto main board, 20 mm bore watering pipe light grade with CI/ MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 m, charcoal dust and common salt in adequate qty all as shown in electrical plate No 3 of SSR Part-I 2009 having pit and cover in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40 x 40 x 6 mm grouted in PCC pit for PCC cover, funnel with wire mesh at STP-II & STP-IV, complete all as specified and directed by Engr-in-Charge. NOTE: The unit rate quoted shall be deemed to include for necessary excavation and earth work, PCC 1:3:6 type C-1 chamber, funnel with GI medium grade watering pipe 15 mm bore, RCC cover slabs 50 mm thick with 8 mm dia CTD bars @ 140 mm C/C both way etc.
All discription as per item No 96.00 above herein, but earth galvanized wire of 4 mm dia complete all as specified and directed.
Rectifying the defects in domestic fluroscent tube/CFL light fittings any type and at any height, ceiling rose, electric bell by tightening loose connections and rectifying defects, testing complete all as specified and directed.
Opening switch mounting plate at normal height upto 1.5 meter, rectifying the defects in fittings and fixtures such as switches, bell push, fan regulator, sockets etc by tightening loose connections, refixing switch plate and testing complete all as directed. Note for Item No 98 & 99 :- The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the fitting and fixtures functional. If replacement of parts/items is required to make the fittings functional, the cost for labour and material for the same will be measured and paid for as "S&F in repairs" under relevant items of this schedule hereinafter and in such cases the above items will not be measured and paid for.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for surface point wiring 1100 Volts grade 1.5 Sqmm PVC insulated FRLS sheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & caping medium grade with all accessories in wall/ceiling/floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS sheathed 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for the following:-
(a) One light/fan point controlled by one switch
(c) One 3 pin socket outlet 5 Amp on independent board.
All as per item No.101 here in before but with cables 2.5 Sqmm for one 3 pin socket outlet 15 Amps on independent board complete all as specified and directed.
Taking down submain wiring cable of any size/type alongwith earth wire with or without concealed/surface conduit/casing caping complete all as specified and directed.
M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, sheated, multi-stranded, copper conductor, cable of two runs, 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire, drawn through and including PVC casing and caping with all fittings like tee, bends, junction box/terminal box fixed on wall/ground/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note :- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length).
M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, unsheated, multi-stranded, copper conductor, cable of two runs, 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire, drawn through existing conduit and junction box fixed in wall/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note:- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length).
S&F in repairs MCB SPN 40 to 63 Amps, ''C'' series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and directed. Make : Havells/Indo Asian/Legrand or equivalent.
S&F in repairs MCB SP, 5 to 32 Amps, ''C'' series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and directed. Make : Havells/Indo Asian/Legrand or equivalent.
S&F in repairs bell electric (ding dong bell) 230 volts AC, single phase complete all as specified and directed. Make : Havells/Anchor/Cona or equivalent.
S&F in repairs lamp holder, PVC/polycarbonate type with back plate complete all as specified and directed.
S&F in repair ceiling rose surface bakelite 65 x 50 mm three terminal on and including PVC junction box of suitable size complete all as specified and directed. Make : Havells/Anchor/Cona or equivalent.
S&F in repairs decorative modular switch 6 Amps single pole one way flush type complete all as specified and directed. Make : Havells /Anchor (Roma) / Cona / Legrand/Crabtree/Philips or equivalent.
S&F in repairs decorative modular switch 6 Amps single pole two way flush type complete all as specified and directed. Make : Havells /Anchor (Roma) /Cona /Legrand /Crabtree/Philips or equivalent.
S&F in repairs decorative modular socket 6 Amps, 3 pin, flush type, multipurpose complete all as specified and directed. Make : Havells / Anchor (Roma) /Cona /Legrand/Crabtree/Philips or equivalent.
S&F in repairs decorative modular switch 16 Amps single pole one way flush type complete all as specified and directed. Make : Havells /Anchor (Roma)/ Cona/Legrand/Crabtree/Philips or equivalent.
S&F in repairs decorative modular twin socket 16 Amps, 3 pin, flush type, multipurpose type complete all as specified and directed. Make : Havells/ Anchor (Roma) /Cona/ Legrand /Crabtree/Philips or equivalent.
S&F in repair decorative modular ceiling fan regulator electronic five step type 230 Volts single phase complete all as specified and directed. Make : Havells/Anchor (Roma) /Cona /Legrand /Crabtree /Philips or equivalent.
S&F in repairs bell push 5 Amps modular type complete all as specified and directed. Make : Havells / Anchor (Roma) /Cona / Legrand /Crabtree /Philips or equivalent.
S&F in repairs of following sizes front plate with base frame for fixing decorative modular switches/ sockets/ regulators etc and matching with existing complete all as specified and directed :- Make : Anchor (Roma) or equivalent in Legrand /Crabtree /Havells/Philips
(a) 2 module
(b) 3 module
(c) 4 module
(d) 6 module
(e) 8 module
S&F in repairs 5 watt LED light fittings 1 feet including making necessary connection complete all as specified and directed. Make : Havells/Philips/C&S/Bajaj.
Supply and fixing in repair round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer in charge.
S&F in repair decorative wall mounting, brushed nickel finished fixture with opal glass diffuser suitable with 9W LED lamp B22 base with back plate including 9W LED bulb complete all as specified and directed by Engr-in-Charge. Make- Havells, Floretine wl 1ls b22 ss or equivalent in Bajaj/Philips/Wipro/C&S.
S&F in repair round profile LED tubelight batten 20 W, 4 feet length, 2000 lm,6500 k complete with all as specified and as directed. MAKE: Bajaj /Havells /philps/CG
S&F in repair 10 watt LED tubelight fittings 2 feet including making necessary connection complete all as specified and directed. Make : Havells /Philips /C&S /Bajaj
S&F in repairs decorative modular 25 Amps one way switch flush type with indicator complete all as specified and directed. Make : Havells/Anchor (Roma) /Cona/Legrand/Philips/Indo Asian
S&F in repairs decorative modular 25 Amps 2 module socket with safety shutter type complete all as specified and directed. Make : Havells/Anchor (Roma) /Cona/Legrand/Philips/Indo Asian
Taking down ceiling fan/exhaust fan of any sweep, dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding etc and hanging up/fixing back in the original position, connecting up and testing complete all as directed. Note : (a) The unit rate quoted shall deemed to be included for minor items viz nuts, bolts split pin and rubber wheel etc. (b) Capacitor & bearing shall be measured and sperately under ser item Nos 127 & 128 here-in-after. (c) Rewinding of fan will be measured and paid for separately under under ser item Nos 129 & 130 here-in-after.
S&F in repairs capacitor of 2.5 mfd for ceiling fan/exhaust fan complete all as specified and directed.
S&F in repairs bearing No 6201/6202/6203 suitable for ceiling fan/exhaust fan complete all as specified and directed. Make : SKF /NBC /TATA /FAG or equivalent.
M&L for removing of burnt out copper winding wire from ceiling fan of any make and size of 1200 mm to 1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.
Description all as per item No 129 here-in-before but exhaust fan of 150 mm sweep complete all as specified and directed..
Repair only energy meter 230/415 volt, 10-25 Amp including making incoming and outgoing electric connection and testing including taking down old defective energy meter and depositing the same to MES store yard complete all as specified and directed.
S&F in repairs heating element 2 KW of storage type water heaters (geyser) embedded type nickel plated duly mineral filled, ISI Marked complete all as specified and directed. Make : CG/ Bajaj/ Racold/ Havells
S&F in repairs brass chrominum plated connection 15 mm dia 460 mm long (heavy duty) with 2 Nos brass chrominum plated nuts and washer for hot water complete all as specified and directed.
S&F in repairs thermostat adjustable between 30 degree C to 85 degree C for geyser complete all as specified and directed.
ANKIT SHIP REPAIRERS AND SUPPLIERS (BID ID -3152521)
SRI RATNA AND CO (BID ID -3161496)
HARSHITA MARINE SERVICES (BID ID -3153633)
Shree Ayyappa Engineering (BID ID -3154470)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .