Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-Finance | L1 | Accepted-Finance ELIGIBLE | |
| 2 | L2₹20.5 L+₹70,815 (3.57%)Accepted-Finance 271 CIVIL LINE GURUGRAM GURUGRAM GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | L2 | Accepted-Finance ELIGIBLE | |
| 3 | L3₹20.9 L+₹1.1 L (5.34%)Accepted-Finance | L3 | Accepted-Finance ELIGIBLE | |
| 4 | L4₹22.4 L+₹2.5 L (12.7%)Accepted-Finance 5 49 SUBASH NAGAR BEHIND SBI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Accepted-Finance ELIGIBLE |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
25 May 2023, 4:00 pmClosed
OFFICE OF THE EXECUTIVE ENGINEER
OFFICE OF THE EXECUTIVE ENGINEER
INSTALLATION OF CAPACITOR BANK AND BATTERY BANK
2023_PDD_211774_1
STD/Doda/CVPP/08 of 2023-24
Open Tender
Electrical Works
Turn-key
60 days
KISHTWAR
KINDLY REFER TO SBD
2 documents required · 2 mandatory
₹1,000
Yes
OFFICE OF THE EXECUTIVE ENGINEER STD DODA
₹49,000
13 Jun 2023
12 May 2023
27 May 2023
12 May 2023
25 May 2023
12 May 2023
12 May 2023 - 17 May 2023
A-SUPPLY PART
INSTALLATION OF 2.4 MVAR CAPACITOR BANK AT 33/11KV 1*6.30MVA RECEIVING STATION KEERU AND INSTALLATION OF 30V DC,VRLA TYPE BATTERY BANK AT TAMROUJI,DOOL
12 kV Capacitor Bank (2.4 MVAR) with VCB Panel with complete arrangement for connection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories.
a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply .
Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories
Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories
B-ERECTION PART
12 kV Capacitor Bank (2.4 MVAR) with VCB Panel with complete arrangement for connection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories.
a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply .
Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories
Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories
power control system
JP Infratech
V-RIDGE ENGINEERING WORKS.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .