Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC VILL BARTAN P O BHIMESWARI BAZAR P S BHAGAWANPUR DIST PURBA MEDINIPUR PIN 721 458 | BHAGAWANPUR | PURBA MEDINIPUR | WEST BENGAL | 721458 | ₹8.0 L | L1 | Accepted-AOC Lowest 1 |
| 2 | L2₹8.2 LRejected-Finance | ₹8.2 L | L2 | Rejected-Finance Not Required |
| 3 | L3₹8.3 LRejected-Finance VILL JAMBURBASAN P O P S NANDAKUMAR DIST PURBA MEDINIPUR PIN 721632 | MEDINIPUR EAST | WEST BENGAL | 721632 | ₹8.3 L | L3 | Rejected-Finance Not Required |
Tender Value
₹8.1 L
EMD Value
₹16,296
Closing Date
30 Jan 2026, 3:00 pmClosed
Secretary of RMC,Salegechia,Tamluk
Office of the RMC, Salegechia,Tamluk
Construction of Setting up a Sufal Bangla outlet at Sonar Tori Market Complex under ward No.-15 within Haldia Municipality under Purba Medinipur District
2026_WBSMB_988237_1
PURBAMZRMC/e-NIT02/2025-26
Open Tender
CIVIL AND ELECTRICAL WORKS
45 days
ward No.-15 within Haldia Municipality under Purba
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,500
₹16,296
Chember of the Secretary of RMC,Salegechia,Tamluk
16 Mar 2026
16 Jan 2026
2 Feb 2026
16 Jan 2026
30 Jan 2026
16 Jan 2026
21 Jan 2026
Civil work
Page No. - 10/2 Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof (a) upto 150 mm. thick
Page No. - 15/8 (b) Brick work with 1st class bricks in cement mortar (1:6) b) In superstructure Ground Floor
P - 26/10 ( Analysis rate ) Ordinary cement concrete ( mix 1:1.5:3) with graded stone chips ( 20 mm. nominal size ) excluding shuttering and reinforcement. if any , in ground floor as per relevant IS codes. a) Pakur Variety Ground Floor
Page No. - 43/40 (ii) ( Analysis rate, 10th Corrigenda dt 24.08.2022 ) Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel II. JSW /JSPL /SHYAM / SRMB / BMASL / ELECTROSTEEL / SSL
Page No. - 42/36 Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fittings, fixing and striking out after completion of works. ( upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height. shall be taken as 4 m and extra for woks beyond the initial 4 m. ht. shall be allowed under 12(e) for every 4 m or part thereof. ) f) 25 mm to 30 mm shuttering without staging in foundation.
Page No. - 189/1 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (b) 20 mm thick plaster
Page No. - 195/7 Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coat ii) Solvent based interior grade Acrylic Primer
Page No. - 201/4 Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) ii) Luxury Quality
Page No. - 106/19 (a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I.Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
Page No. - 250/27 Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) (a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating)
Page No. - 200/1 (a) (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Page No. - 200/2 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Page No. - 233/1 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - InCharge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film k) Movable door shutter. i) Door frame. (Top & sides)
ii) Shutter : Top rail
Bottom rail
Lock rail
Door vertical
Glazing cleap
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- (B) Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge.
Page No. - 242/5 Supplying concealed type heavy duty PVC headed aluminium tower bolt for double leaf doors as per approved make and brand as per direction of Engineer-in-Charge. (a) 200 mm long
Page No. - 243/9 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 4mm thick coloured / tinted / smoke glass.
Page No. - 244/13 (A) Supplying Aluminium casted body hydraulic door closer as per I.S.I
Page No. - 244/13 (B) Supplying 125 mm. Dia acrylic handle for aluminium door as per approved make & brand. (a) Natural Colour
Page No. - 244/ 13 (D) Supplying Aluminium casted body Butt Hinge (KOBRA type). (Natural white)
Page No. - 244/ 13 (F) Supplying Zinc powered coated star lock (Natural White)
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (B) Light Colour
Electric
Sub-Head 1--Distribution Wiring
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish
8mtr [1(iii) / E-20 ]
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC)incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish
On Board [ 3 (a) / E- 20 ]
Sub-Head 2-- Plugs& Sockets
Supplying & Fixing 6 way GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works [1(b)/ E-17 ]
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required [3(a)/ E-17 ]
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[4(a)/ E-17 ]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[9(b)/ E-18 ]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [5(a)/ E-17 ] [For AC](make-Legrand, model-Myrius/modular)
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[17/E-19] [For AC](make-Legrand, model-Myrius/modular)
Sub-Head3--VTPN,TPN & SPN DB
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+12Way[ Legrand ] [ 13 / D- 9 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand )
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ]
Sub-Head 4-- Polythene pipe and wires
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe without earth continuity wire by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 18 SWG mending good damages to original finish by using own tools and tackles [ 7A / E-3 ]
25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Drawing 1.1 KV single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
2x(1.5 sqmm)+1x(1.5 sqmm) (For seperate plug /Outdoor light) [ 1A / E-9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) (For Power plug & Computer Plug) [ 1a / E-9 ]
2x(4 sqmm)+1x (2.5 sqmm) (For AC) [ 1a / E- 9 ]
2x (6 sqmm) + 1x (4 sqmm) (For TPNDB to SPNDB) [ 1a / E- 9 ]
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC(for M/S via C/O to HTPNDB)
2x(16 sqmm)+1x(10 sqmm) (For Meter to Main Switch) [ 1A / E-9 ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
1.5sqmm [NS]
2.5sqmm [9 (i)/F-5]
4 sqmm [9 (ii)/F-5]
6 sqmm [9 (iii)/F-5]
10 sqmm [9 (iii)/F-5]
Sub-Head 5-- Supply & Laying of Cables
Supply of 2/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / RR Cable /Havells / Gloster]
2core 6 Sq. mm [ NS ]
Fixing only recess mounted light fitting in the ceiling as per GS [17/C-2]
Fixing only lamp [11/ C-2 ]
Sub-Head 7 - Supply of Light Fittings
Supply Green perform prime G2 IS a highbay designed to deliver excelent efficiency at 160lm/watt. Make-Philips cat no-BY615 LED 100S 5700 NB PSU GR
Supply and delivery of 230V, Single LED tube light fittings incl. all acc. (Make: Philips cat no.- TMC 501P-1xT-LED22WP3241 incl. 1x 1200mm 18W, 2100lm PC body./ Wipro/ Crompton/ Havells)
Supply 9W LED lamp to the lamp point. [PHILIPS make]
Sub-Head 8 --Fixing of Fan
Fixing only wall fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS
Sub-Head 9-- Supply of Fan
Supply of wall fans complete with all accessories ( Make -Crompton /EPC-Metal body, 16"/400mm )
400 mm Sweep ( High Speed ) [ NS ]
9" ( 230mm ) Speed 1370 RPM [ NS ]
Sub-Head 10 --Main Swirch,Change over Switch , Misceleneous
Supplying&fixingsheetmetal(16SWG)IronCladBusbarchambersonangleironframeonwall, incl. earthingattachment andpaintingas required–(As per Drawing no. 470 of PWD Specification Book – May 1991
Supplying and fixing L&T 63A 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc. [ 2(b)/D-1]
S&F 415V L&T 63 A TPN MSFU, Type: FN 63 TPN, on angle iron frame on wall with nuts & bolts etc. including S&F three nos. DIN type HRC type fuse as per rating. [PWD/GS Page No.: D3 Item No.: 4/a ]
Sub-Head 12-- Earthing
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground evel and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By ISI-Medium GI pipe [2a (G-1)]
Supplying & fixing earth busbar including Connecting the equipments of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2 ]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Solid GI wire No 4 S.W.G wire [5(a) ii /G-2 ]
Excavation of soil for installation of Earth Electrode and filling & ramming. For soft Soil [ 1(a)/G-1 ]
Supplying & fixing earth busbar including Connecting the equipments of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2 ]
Add 9% CGST
Add 9% SGST
Add 1% Labour Cess
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.