Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC 236 NATHORE TEHSIL RANIA SIRSA 125055 | SIRSA | HARYANA | 125055 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.7 L+₹49,315 (4.83%)Rejected-Finance JOGINDER SINGH S O BALVINDER SINGH NAIWALA DISTRICT SIRSA 125075 | NAIWALA | SIRSA | HARYANA | 125075 | L2 | Rejected-Finance L2 |
Tender Value
₹10.1 L
EMD Value
₹20,279
Closing Date
16 Aug 2024, 5:00 pmClosed
PRAMESH Kumar
ED - Hisar
Widening of road by strengthening of road Odhan to Ghukanwali (V2) (road id 5732) in Km 0.90 to 5.40 and IPB in Km 0.00 to 0.90, 5.40 to 5.60 in sirsa distt. (under S/Division DHBVN, Kalanwali) RECALL
2024_HRY_398566_1
2024030C9C7B D255 4594 BC42 E55D3D87C73F666BAR
Open Tender
Electrical Works
Works
240 days
GHUKANWALI
2 documents required · 2 mandatory
₹1,000
₹20,279
Yes
28 Nov 2024
9 Aug 2024
19 Aug 2024
9 Aug 2024
16 Aug 2024
9 Aug 2024
Amount
Supply of PCC pole 11 Mt long complete in all respect as per DHBVN specifications and upto the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of V-Shape (X Arm) 100x50 mm2 (ISMC-100) Wt.13.200 Kg complete in all respect as per DHBVN specifications and upto the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of MS Angle 50x50x6 mm2 2400 mm2 (for Earth wire ) Wt. 10.80 kg complete in all respect as per DHBVN specifications and upto the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of Channel (X Arm)100x50 mm2 2200 mm2 (for H pole) Wt. 21.032 kg complete in all respect as per DHBVN specifications and upto the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply of Channel (T off ) 100x50x6 mm2 3050 mm2 Wt.29.158 kg complete in all respect as per DHBVN specifications and upto the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of Channel (T off ) 75x40x6 mm2 2200 mm2 for Fuse unit Wt.15.70 kg complete in all respect as per DHBVN specifications and upto the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of Angle 50x50x6 mm2 2860 mm2 (Bracing H Pole ) Wt. 12.87 kg complete in all respect as per DHBVN specifications and upto the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of Angle 50x50x6 mm2 2200 mm2 (Belting for H-Pole ) complete in all respect as per DHBVN specifications and upto the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply of ACSR Conductor 50 mm2 (Rabbit) complete in all respect as per DHBVN specifications and upto the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of PG Clamps for 30/50/80/100mm2 complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of Half Clamp Wt. 1.47 Kg complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of Full Clamp Wt. 2.325 Kg complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection Fitting for 11 KV Disc Insulator 45 KN (TandC type) complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of 11 KV Polymeric Pin insulator with Pin complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of GSL 8 SWG complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of Barbed Wire complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply of GI Strip 25 x 6 mm 15 Mtr for earthing Wt. 10.80 Kg complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply of stay wire7/8 SWG complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of GI Nut and Bolt complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply of Stay set complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply of G.I. Pipe 40mm dia 6 mtr long for earthing set B class complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of Danger Plate with clump complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of Number Plate with clump complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of 11 KV Disc for stay complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Erection of 11KV LA complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
S/E of Eye Screw Bolt complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Supply and Laying of Salt,CharCoal and Nosadar for Earthing complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Sandry Job Charges
E/o PCC pole 11 M per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
E/o ACSR Conductor 50mm2 as per DHBVN specifications the entire satisfaction of Engineer-in-Charge. (Excluding GST)
E/o HT Dead end for H pole structure with two stay as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
E/o 100 to 200 KVA T/F pole mounting Substation as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
E/o 25 to 63 KVA T/F pole mounting Substation as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
E/o lightning arrestor set 9 KV 10 KA Heavy duty as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
E/o 11 KV T-off equipment with stay complete with one stay as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
E/o 4 core50mm2 LT Cable as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Loading and unloading and transportation of the PCC 11 M long pole for each pole (Excluding GST)
Transportation Charges of ACSR @ 1 % of cost of material i.e. Rs. 186000/- (Excluding GST)
E/o GSL 8 SWG as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
E/o of number plate with clump and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
E/o of danger plate with clump and to the entire satisfaction of Engineer-in-Charge. (Excluding GST)
D/o PCC pole 9 M long with allied material required (Excluding GST)
D/o ACSR Conductor 30 mm2 from the site (Excluding GST)
D/o HT Dead end for H pole structure with two stay from the site (Excluding GST)
D/o 100 to 200 KVA T/F pole mounting Substation without H-Pole from the site(Excluding GST)
D/o 25 to 63 KVA T/F pole mounting Substation from the site (Excluding GST)
D/o Stay set complete with barbed wire from the site (Excluding GST)
D/o S/C x 4 core 50mm2 LT Cable from the site (Excluding GST)
Supply of LT PVC Un-Armed 4 core Cable S/C x 50mm2 complete in all respect as per DHBVN specifications and the entire satisfaction of Engineer-in-Charge. (Excluding GST)
Bajwa Electrical Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .