| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.6 L+₹1.4 L (11.5%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
5 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
COMPREHENCIVE REPAIR TO CLEAR WATER COMPLEX POWER HOUSE AND ALLIED WORK AT MILITARY STATION SRI GANGANAGAR
2020_MES_384594_1
GE SGNR/ TOK-40 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Sri Ganganagar
E Class a (i) and for un-enlisted, refer NIT para 8
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹30,000
Yes
15 Dec 2020
8 Oct 2020
7 Nov 2020
8 Oct 2020
5 Nov 2020
15 Oct 2020
60 days
Amount
Dismantling brick tiles or terracing tiles, single layer on roof complete all as specified and directed by Engineer - in - Charge.
M&L for 40mm thick brick tiles laid on lime concrete & joint grouted flush in CM (1:3) mixed with 5% of crude oil by weight of cement on lime concrete complete all as specified and directed by Engineer-in-Charge.
Fixing only 40mm thick brick tiles laid on lime concrete & joint grouted flush in CM (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed by Engineer-in-Charge.Note;- Serviceable tiles obtained Srl item No 01 shall be re-used
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and directed by Engineer - in - Charge.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground Concrete, brick work, masonry, etc.complete all as specified and directed by Engineer - in - Charge
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-charge.
M&L for RCC 1:2:4 , Type B-0 (20 mm graded aggregate) ( Nominal mix) as in chajjas complete all as specified and directed by Engineer - in - Charge.
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (Nominal mix) (20mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge
M&L for formwork to to sides of pillars, posts, struts, piers, columns and stanchions including for edges for rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge
S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer - in - Charge.
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-4100 Gde-E-310 complete all as specified and directed by Engineer - in - Charge.
M&L for pre-cast RCC jallies 25 mm thick(measured soild) 1:2:4 , Type B-0 (12.50 mm graded stone aggregate) and set in cement mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
M&L for 75 mm thick PCC (1:4:8) type D-2, (40 mm graded stone aggregate) as in flooring finishing the surface even and smooth complete all as specified and directed by Engineer - in - Charge
M&L for 100 mm thick PCC (1:4:8) type D-2, (40 mm graded stone aggregate) as in flooring finishing the surface even and smooth complete all as specified and directed by Engineer - in - Charge
M&L for 25mm thick cement concrete (1:2:4) type B-0, (12.5 mm graded stone aggregate) as in flooring finishing the surface even and smooth complete all as specified and directed by Engineer - in - Charge
M&L for PCC (1:4:8) type D-2, (40 mm graded stone aggregate) as in foundations complete all as specified and directed by Engineer - in - Charge
M&L for Providing precast cement concrete 1:2:4 Type B–1 (20mm graded stone aggregate) for kerb stone and similar works with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in CM 1:4 with joints to match complete all as specified and directed by Engineer - in - Charge.
M&L for Providing precast cement concrete 1:3:6 Type C-2 (40mm graded stone aggregate) as in foundation of posts and struts complete all as specified and directed by Engineer - in - Charge.
M & L for 50mm thick cement concrete type C-1, 1:3:6 (20mm graged stone aggregate) as in plinth protection complete all as specified and directed by Engineer-in-charge
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer - in - Charge.
Demolition of cement concrete in ground floor and paving n. exc. 15cm thickness (below or above ground level) of any description complete all as specified and directed by Engineer-in-Charge.
M&L for precast coloured rubber moulded concrete machine pressed concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60 mm thickness, M 35 grade wirh grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
Demoliton of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed by Engineer - in - Charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 except bricks complete all as specified and directed by Engineer - in - Charge.
Taking down cement plaster on brick or concreate wall surfaces including racking out joints, hacking for key, scrubbing down with water etc. complete complete all as specified and directed by Engineer-in-Charge.
M&L 15 mm thick rendering in CM 1:6 on brick / concrete wall surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L 15 mm thick rendering in CM 1:4 on brick / concrete wall surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L 5 mm thick rendering in CM 1:3 on ceiling surfces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint, over a coat of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plaster surfaces of ceiling and applying three coat of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plaster surfaces of walls and applying two coat of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated plastered or un-plastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of cement base paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old decorated plastered surfaces of ceiling by brooming down or steel wire brushing,scrapping down smoke soot, moulds,moss and efflorescent salts and trading oil and greasy spots and applying one coats of white wash complete all as specified and directed by Engineer - in - Charge.
M & L for preparation of old decorated plastered surfaces of walls by brooming down or steel wire brushing,scrapping down smoke soot,moulds,moss and efflorescent salts and trading oil and greasy spots and applying one coats of white wash complete all as specified and directed by Engineer - in - Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises,complete all as specified and directed by Engineer-in-charge.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exc. 0.11 sqm but not exc 0.18 sqm in floor etc, laid over and including 15 mm thick screed bed in CM 1:4 and set and jointed in cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M&L for glazed ceramic coloured tiles interior grade, of size 300x600x7mm thick as on vertical surfaces laid over and including 10mm thick rendering in CM 1:4 and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M & L for 20-25 mm thick machine cut kota stone slab flooring laid over and including 20 mm thick screed bed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer - in - Charge.
M&L for TMT bars 8 to 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia using TMT bars complete all as specified and directed by Engineer - in - Charge.
M & L for mild steel TMT bars 5mm dia and over upto and including 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and directed by Engineer - in - Charge.
M&L for mild steel work as in posts and struts of fencing including cutting tops to shape, drilling holes, notching for wire etc conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engineer - in - Charge.
S&F 10 mm dia MS round bar for fixing of chain link fencing with post complete all as specifies and directedby Engineer - in - Charge.
Supply only chain link fencing galvanised mild steel hot dipped(IS -2721) of 4 mm dia of mesh size 100x100 mm complete all as specified and directed by Engineer - in - Charge. Note:- The weight of chain link fencing shall be ascertained by BOO as directed by GE and payment shall be paid accordingly BOO duly countersigned by GE shall be encloused with final bill.
Fixing only of chain link fencing including line wires, any mesh size and type to any type of satanderds, rails, straining bolts etc including binding wire complete all as specifed and directed by engineer-in-charge.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and dia of neck 11 to 15 mm complete all as specified and directed by Engineer - in - Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc. 1.5 sqm but n. exc.4 sqm each complete all as specified and directed by Engineer - in - Charge.
Taking down carefully hood of steel rolling shutters, exc 25 sqm for replacement of unservicable/ defective parts and refixing in the same location, including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, complete, gear operated type with bevel gear box and crank handle size of shutter complete all as specified and directed by Engineer - in - Charge
S&F ball bearing for rolling shutters complete all as specified and directed by Engineer-in-charge.
M&L for pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer - in - Charge.
M&L for pressed steel frame for doors of size 105 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer - in - Charge.
Cutting holes in brick wall built in cement mortar for inserting holdfasts, depth of embedded portion n exc half brick (measured from the face of jamb into the wall) and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified & directed by Engineer-in- charge..
S & F 35mm thick,Second class hard wood factory made wire glazed and skeleton door, window shutters open rebated and prepared to receive glass, gauze, etc divided into squares with plain, chamfered or rounded mitred and rebated sash bars any number & fitted with cut and mitred beads for securing gauze/wire cloth, etc sizes of members of shutters as specified in SSR Part-I, section 8 clause 8.24 (a) complete all as specified and directed by Engineer - in - Charge.
S & F 35mm thick,Second class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer - in - Charge.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer - in - Charge.
Supply only butt hinges, medium weight, cold rolled mild steel, and fixed of size 100mm fixing properly with screws etc complete all as specified and directed by Engineer - in - Charge.
Supply only butt hinges, medium weight, cold rolled mild steel, and fixed of size 50mm fixing properly with screws etc complete all as specified and directed by Engineer - in - Charge.
S&F 300mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed. complete all as specified and directed by Engineer - in - Charge.
S&F 150 mm mild steel barrel tower bolts, stove enamelled black with bright bolt & fixed complete all as specified and directed by Engineer - in - Charge
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including fittings complete all as specified and directed by Engineer-in-charge.
S&F 110 mm PVC (SWR) bends any raduis complete all as specified and directed by Engr-in-charge.
S&F 110 mm PVC (SWR) pipes single socked in any length with rubber ring joints, fixed to walls all as specified and directed by Engr-in-charge.
M&L for preparation of old wood and wood based surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint (ordinary tint) over a coat of Pink primer complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer complete all as specified and directed by Engineer - in - Charge.
Dismantling and taking down water tank of capacity exc. 250 Litre but n. exc. 500 litre capacity complete all as specified and directed by Engineer - in - Charge.
S&F rotational moulded polyethylene water storage tank 500 litre capacity (Cylindrical vertical with closed top) hoisted and fixed in position with necessary fittings complete all as specified and directed by Engineer - in - Charge. (Note : PVC tanks shall be ISI marked, having three layres)
S&F 20mm bore Ball brass valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed by Engineer - in - Charge.Note:- Minimum weight 455gms
Excavation over areas n.exc. 1.5 m wide & n. exc. 1.5m in depth for foundation etc. n. exc 10 sqm on plan and n. exc. 1.5 m in depth in hard/loose soil and getting out complete all as specified and directed by Engineer - in - Charge
Removing excavated material n. exc. 50 m & depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer - in - Charge.
Dismantling and shifting of existing steel gate n exc 20 meters distance and n exc 500 kg in weight complete all as specified and directed by Engineer - in - Charge.
Taking down copper/aluminium point wiring (light,fan,socket or power)complete including fixture and fittings such as switches& sockets and removing materials for taking credit complete all as specified and directed by Engineer-in-charge.
M&L for concealed conduit point wiring complete for light /fan with cable 1.5 sqmm(Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC conduit pipe medium grade 20mm bore,pipe hooks,elbows,junction covers and junction boxes, after cutting in wall chasing for conduits and sinking's for sunken cast iron /pressed steel terminal boxes of suitable length and thickness for mounting switches, sockets, fan regulator with 3mm thick plastic laminated seat cover fixed with brass screws and cup washers, duly grouting and painted with red oxide metal primer and making good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth contuity conductor along with point wiring of 1.5 sqmm copper FRLS PVC insulated cable for one light/fan point controlled by one way switch and connected to common earth dolly, complete all as specified and directed by Engr-in-charge.
All as described in Srl item No -73 here in before but for one switch socket combination 5/6 Amps on independent board complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No -73 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No. 73 here in before but for one switch socket combination 6 pin 5/15 Amps on independent board with 2.5 Sqmm (Nominal Area) FRLS PVC insulated multistranded unsheathed copper conductor and continuous earth contuity conductor along with point wiring of 2.5 sqmm copper FRLS PVC insulated copper cable complete all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type 5/6 Amp single pole one way complete all as specified and directed by Engineer - in - Charge
S & F switch socket combination 5 pin, 5/6 Amps flush type complete all as specified and directed by Engineer - in - Charge
S&F Switch socket combination 2 in 1, 6 pin , 15/16 Amp flush universal type all as spd and directed by Engr in charge.
S & F Socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F ceiling rose, surface bakelite 65x50 mm three terminals complete all as specified and directed by Engineer - in - Charge.
S & F stepped type,single socket fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge
S & F in replacement extruded aluminium LED batten channel 20 watt having input voltage AC90-300V, 50Hz, 6500K, with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge.
S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.
S&F in replacement security light fitting LED TYPE 25 watt with all necessary accessories, Clear transparent acrylic cover, prewired suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge.
S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 4 ways, 240 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacement sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn in existing PVC conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
S & F sub-main wiring with two single core cables PVC insulated and un-sheathed 4 sqmm (Nominal Area) FRLS stranded copper conductor drawn in existing PVC conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 4 mm dia GI earth wire, by means of bolts, nuts check nuts and washers of galvanised iron and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point including taking our unserviceable earthing with all acessories all as specified or indicated including testing on completionall as specified and directed by Engineer - in - Charge.
Cutting/ trimming of tree branches not exc 10cm girth touching/ approaching the LT/HT overhead lines with hack saw/axe to clear the LT/HT line upto 3 metre on each side (Horizontal and / or vertical) including disposal of trimmed branches 2 KM away inside the Military station area & clearing site complete all as specified and directed by Engineer-in-Charge. Note :- 3 metre width on each side of LT/HT line shall be cleared and each span having not less than 3/5 conductors and min30-40 m pole to pole distance shall be measured as each span
Supplying, laying , testing and connecting to LED back lit single side signage boards with IP-65 CRCA housing, vinyl print on acrylic sheet which is back lit with high grade, high brightness LED modules, in built SPMS driver complete all as specified and directed by engineer in charge.
S&F in replacement, slip ring assy comprising of min four rings for 3 phase with nutal supply suitable for three nos 2 HP three phase induction motors including carbon brush, brush holder and accessories complete suitable for clariflocculator 80 thousand imp gallons per hours capacity at filteration plant complete all as specified and directed by engineer in charge.
S & F in replacement suspended type linear LED module, 36 watts, including driver, aluminium housing, IP 40 protected complete with mounting accessories, including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge.
Note : Notes : (i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
J and P CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .