| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC 12 HAJI MD MOHASIN SQUARE KOL 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | ₹4.7 L | L1 | Accepted-AOC AOC |
| 2 | L2₹4.8 L+₹894 (0.19%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | ₹4.8 L+₹894 (0.19%) | L2 | Rejected-Finance Higher than Lowest quoted amount |
| 3 | L3₹4.8 L+₹949 (0.20%)Rejected-Finance 447 A DHALITITHA BASIRHAT NORTH 24 PARGANAS PIN 743412 WEST BENGAL | BASIRHAT | NORTH 24 PARGANAS | WEST BENGAL | 743412 | ₹4.8 L+₹949 (0.20%) | L3 | Rejected-Finance Higher than Lowest quoted amount |
| 4 | L4₹4.8 L+₹4,023 (0.85%)Rejected-Finance 31 1 6 SEBADAL ROAD UDAYPUR NIMTA KOLKATA 49 | 24 PARAGANAS NORTH | WEST BENGAL | 700049 | ₹4.8 L+₹4,023 (0.85%) | L4 | Rejected-Finance Higher than Lowest quoted amount |
| Sl No | Description | Qty | Unit | SKY DECORATIONS PRIVATE LIMITED L2 | MODERN REFRIGERATION AND ELECTRICAL WORKS L1 | FAME ENGINEERING L4 | BENGAL TRADING CO L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation,Testing & Commissioning of split type AC machines having capacity Cooling Capacity range (6.6-7.0 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -2/3 (EER range 3.5 to 3.99),air-flow range CFM(760-850) both condenser and cooling coils made of copper tube connecting chord with plug top confirming to ISI 1391 (Part-I & Part-II) with all amendments incl. leak testing , brazing if required as per direction of E.I.C (Make-Mitsubishi Electric-MS-GK24VA/ Mitsubishi Heavy -SRK24 CW-S6/O-General -ASGA24BMAA-B) ( K.C room, B.R room and R.K.D room) | 3 | Nos | 78,000 ₹2,34,000 Lowest | 79,500 ₹2,38,500 | 78,000 ₹2,34,000 Lowest | 79,000 ₹2,37,000 |
| 2.00 | SITC of 3.0 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 36000 BTU/hr. with 2Nos. Rotary compressor,2nos. IDU Rated power supply-230V-1ph-50Hz.Air-flow/per IDU:- 650CFM incl. leak testing , brazing if required as per direction of E.I.C.(Make: Hitachi/Daikin/Bluestar) (For lab of 3rd floor) | 1 | Nos | 1,25,000 ₹1,25,000 | 1,25,000 ₹1,25,000 | 1,20,000 ₹1,20,000 Lowest | 1,23,000 ₹1,23,000 |
| 3.00 | Supply ,installation testing and commissioning of copper refrigerant pipe line for liquide line & suction line with supports and brackets (as per direction of EIC)and mending good damages to original finish incl. brazing and nitrile rubber insulation 6/9 mm thick class "O" etc . with wrapping tape complete over the insulation as required.
Make for Cu lpipe- Rajco/Ryoku/Mandev/Nippon
Make for Insulation- Suprime,Accoflex/armacell)
(a) 5/8” dia with 0.6mm thick Suction Line. | 50 | mtr | 450 ₹22,500 | 420 ₹21,000 Lowest | 530 ₹26,500 | 430 ₹21,500 |
| 4.00 | b) 1/4" dia with 0.6 mm thick Liquid Line. | 50 | mtr | 250 ₹12,500 | 220 ₹11,000 Lowest | 290 ₹14,500 | 230 ₹11,500 |
| 5.00 | Wrapping both the copper pipe with kenofoam sulation by 26 SWG aluminum sheet to make it vermin proof. | 50 | mtr | 110 ₹5,500 | 100 ₹5,000 Lowest | 110 ₹5,500 | 105 ₹5,250 |
| 6.00 | Supply & Charging Refrigerant - 410A | 6 | Kg | 900 ₹5,400 | 1 ₹6 Lowest | 980 ₹5,880 | 950 ₹5,700 |
| 7.00 | Supply and fixing fire retardant nonporous double layer flexible connection (Canvas ) for concealed split air-conditioners as per direction of E.I.C | 1 | Nos. | 1,750 ₹1,750 | 1,500 ₹1,500 Lowest | 1,610 ₹1,610 | 1,650 ₹1,650 |
| 8.00 | Supply and drawing 3 core 2.5 Sq.mm PVC insulated shethed cable for connecting the outdoor to indoor supply ( Make: RR Kable/Polycab/Glostar). | 50 | Rmt. | 130 ₹6,500 | 125 ₹6,250 Lowest | 140 ₹7,000 | 132 ₹6,600 |
| 9.00 | Supply and fixing of powder coated extruded aluminium air diffuser without aluminium volume control damper as per specification (make- Systemair/Premire/Caryair/ Airmaster) | 3 | Sq.Mtr. | 8,500 ₹25,500 | 8,500 ₹25,500 | 7,800 ₹23,400 Lowest | 8,300 ₹24,900 |
| 10.00 | Supplying, fitting & fixing in position suspended false ceiling with frame work of aluminium hollow section of size 50mm x 25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm having size of 600mm x 600mm ceiling with aluminium composit panels (ACP) - Interior grade of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent complete in all respect including all incidental charges etc. as per direction of Engineer - in - charge. | 10 | Sq.Mtr. | 2,600 ₹26,000 Lowest | 3,000 ₹30,000 | 2,800 ₹28,000 | 2,700 ₹27,000 |
Tender Value
₹4.8 L
EMD Value
₹9,590
Closing Date
25 Aug 2025, 2:00 pmClosed
the AE_KCESD_II
office of the AE_KCESD_II
Replacement of four nos split type AC machines at 3rd floor of Block C of Chemical Examination Laboratory 46 Christopher Road Kol 700046
2025_PWDE_889722_1
WBPWD/AE/21/Q/KCESD/II of 2025-26(2nd Call)
Open Tender
ELECTRICAL WORKS M/R
Item Rate
15 days
Chemical Examination Laboratory 46 Christopher Roa
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,590
office of the AE_KCESD_II
3 Sept 2026
11 Aug 2025
27 Aug 2025
11 Aug 2025
25 Aug 2025
18 Aug 2025
18 Aug 2025
Amount
Supply, Installation,Testing & Commissioning of split type AC machines having capacity Cooling Capacity range (6.6-7.0 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -2/3 (EER range 3.5 to 3.99),air-flow range CFM(760-850) both condenser and cooling coils made of copper tube connecting chord with plug top confirming to ISI 1391 (Part-I & Part-II) with all amendments incl. leak testing , brazing if required as per direction of E.I.C (Make-Mitsubishi Electric-MS-GK24VA/ Mitsubishi Heavy -SRK24 CW-S6/O-General -ASGA24BMAA-B) ( K.C room, B.R room and R.K.D room)
SITC of 3.0 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 36000 BTU/hr. with 2Nos. Rotary compressor,2nos. IDU Rated power supply-230V-1ph-50Hz.Air-flow/per IDU:- 650CFM incl. leak testing , brazing if required as per direction of E.I.C.(Make: Hitachi/Daikin/Bluestar) (For lab of 3rd floor)
Supply ,installation testing and commissioning of copper refrigerant pipe line for liquide line & suction line with supports and brackets (as per direction of EIC)and mending good damages to original finish incl. brazing and nitrile rubber insulation 6/9 mm thick class "O" etc . with wrapping tape complete over the insulation as required. Make for Cu lpipe- Rajco/Ryoku/Mandev/Nippon Make for Insulation- Suprime,Accoflex/armacell) (a) 5/8” dia with 0.6mm thick Suction Line.
b) 1/4" dia with 0.6 mm thick Liquid Line.
Wrapping both the copper pipe with kenofoam sulation by 26 SWG aluminum sheet to make it vermin proof.
Supply & Charging Refrigerant - 410A
Supply and fixing fire retardant nonporous double layer flexible connection (Canvas ) for concealed split air-conditioners as per direction of E.I.C
Supply and drawing 3 core 2.5 Sq.mm PVC insulated shethed cable for connecting the outdoor to indoor supply ( Make: RR Kable/Polycab/Glostar).
Supply and fixing of powder coated extruded aluminium air diffuser without aluminium volume control damper as per specification (make- Systemair/Premire/Caryair/ Airmaster)
Supplying, fitting & fixing in position suspended false ceiling with frame work of aluminium hollow section of size 50mm x 25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm having size of 600mm x 600mm ceiling with aluminium composit panels (ACP) - Interior grade of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent complete in all respect including all incidental charges etc. as per direction of Engineer - in - charge.
Installation Charges for Trap Door with Aluminium Channel & ACP board (3 mm thick) (Make-Aludecor/Protap Bond) complete with linkage levers fittings supports all acceessories for IDU maintenance as per direction of E.I.C
Supply & Laying Drain Water piping work out of PVC/HDPE hard pipes with Insulation, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors.(Mk. Oriplast / Supreme) (a) 25mm dia
Supply & Fixing of Heavy Duty Anti-Vibration Pad for Isolation of Unwanted Vibration during the ODU in operation.
Charges for taken down the dismantled items of A.C machines i.e IDUs,ODUs, pipe lines etc.from existing places of the building to the dumping area and lifting of new AC machines IDUs and ODUs and others necessary items to the places where they are proposed to be installed with the help of 2 nos. unskilled labour.
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage for AC machines installation, per storey of building per vertical run.
Dismantling of existing Split type Air conditioner machines(IDUs/ODUs/Pipelines) with all necessary arrengements and mending good damages as to GS and handed over to the authority as per direction of EIC.
SKY DECORATIONS PRIVATE LIMITED (BID ID -6865956)
BENGAL TRADING CO (BID ID -6864286)
FAME ENGINEERING (BID ID -6871127)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .