Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC VILLAGE P O TANGNU TEHSIL CHIRGAON DISTT SHIMLA H P | SHIMLA | HIMACHAL PRADESH | 170009 | ₹1.9 L | L1 | Accepted-AOC Awarded to L1 |
| 2 | L2₹2.0 LRejected-Finance 1301 3 SHASTRI NAGAR MEERUT U P 250004 | MEERUT | UTTAR PRADESH | 250004 | ₹2.0 L | L2 | Rejected-Finance L2 |
| 3 | L3₹22.4 LRejected-Finance 284 VEENA NAGAR CAMP DISTT JAGADHARI YAMUNA NAGAR 135001 HARYANA | YAMUNANAGAR | HARYANA | 135001 | ₹22.4 L | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical BILASPUR | - | - | Rejected-Technical as requested by contractor |
| Sl No | Description | Qty | Unit | RAJU ENGINEERING WORKS L3 | V.L. ELECTRICALS L2 | padam singh L1 |
|---|---|---|---|---|---|---|
| 1.00R/m of 66/22 S/Stn of Andhra | ||||||
| 1.01 | Install and providing luminaries at the periphery of the switchyeard of Andhra Power House on existing structures using three-core branch circuit wiring approximately 7 meters per pole. The installation will cover luminary being 70W with an IP66 weatherproof rating, ensuring complete setup and functionality of floodlights at the Andhra Power House. The luminaries should be of reputed brand s.a. Panasonic/Bajaj/Havells/Syska have a system wattage of 70W, preferrable equivalent to HAVELLS JETA ALBA FLOOD LIGHT 70 Watt 5700K, Built-in potted, electronic LED driver with APFC, lower THD, Open Circuit Protection, Over Voltage Protection, Phase to Phase Protection, Surge Voltage Protection upto 10kV with built In SPD & other safety test as per IS 15885 Part-2/Sec 13, an ingress protection rating of IP66 as per IS:10322 (Part 1):1982 latest and come with a 2-year warranty for free replacement. They operate within an input voltage range of 90 to 300 volts AC at 50 Hz ± 2 Hz, with a rated voltage of 230 V AC at 50 Hz including clamps to be provided if required for fixing at existing poles of switchyard at Andhra Power House. | 22 | Each | 7,490 ₹1.9 L | 6,500 ₹1.7 L | 6,380 ₹1.7 L |
| 1.02 | Installation of driving flood light points involves setting up an LED light starting panel with a suitable MCB Single Phase Circuit starter built AC MCB 10A AC SPD 320V along with Dusk Down Sensor 4 Nos. Install Complete in all respect along with indicator complete box and backup fuse inside panel. This includes wiring from the panel to the light points using a 150-meter for each Site Location, four-core PVC insulated sheathed Cu flexible cable, 1.5 sqmm cable. The installation also covers street points and includes a three-phase starter panel to ensure comprehensive coverage and functionality at Andhra Power House. | 1 | Job | 25,000 ₹29,500 | 25,000 ₹29,500 | 24,000 ₹28,320 |
Tender Value
₹1.7 L
EMD Value
₹1,680
Closing Date
17 Apr 2026, 11:00 amClosed
RE Andhra
Resident Engineer, AndhraPower House Division, HPSEBL, Chirgaon, Distt.ShimlaHP-171208
Installation and Provision of Luminaries and Flood Light of Weatherproof at different location of Andhra Power House at Andhra Power House Division, HPSEBL, Chirgaon
2026_HPSEB_133361_1
APHD/2026-27-02
Open Tender
Electrical Works
30 days
Chirgaon
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Yes
₹1,680
Yes
22 Apr 2026
4 Apr 2026
17 Apr 2026
4 Apr 2026
17 Apr 2026
4 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
R/m of 66/22 S/Stn of Andhra | - | - | - | - | BI01010001010000000000000515BI0100001112 | |
| 1.01 | Install and providing luminaries at the periphery of the switchyeard of Andhra Power House on existing structures using three-core branch circuit wiring approximately 7 meters per pole. The installation will cover luminary being 70W with an IP66 weatherproof rating, ensuring complete setup and functionality of floodlights at the Andhra Power House. The luminaries should be of reputed brand s.a. Panasonic/Bajaj/Havells/Syska have a system wattage of 70W, preferrable equivalent to HAVELLS JETA ALBA FLOOD LIGHT 70 Watt 5700K, Built-in potted, electronic LED driver with APFC, lower THD, Open Circuit Protection, Over Voltage Protection, Phase to Phase Protection, Surge Voltage Protection upto 10kV with built In SPD & other safety test as per IS 15885 Part-2/Sec 13, an ingress protection rating of IP66 as per IS:10322 (Part 1):1982 latest and come with a 2-year warranty for free replacement. They operate within an input voltage range of 90 to 300 volts AC at 50 Hz ± 2 Hz, with a rated voltage of 230 V AC at 50 Hz including clamps to be provided if required for fixing at existing poles of switchyard at Andhra Power House. | 22 | Each | - | - | - |
| 1.02 | Installation of driving flood light points involves setting up an LED light starting panel with a suitable MCB Single Phase Circuit starter built AC MCB 10A AC SPD 320V along with Dusk Down Sensor 4 Nos. Install Complete in all respect along with indicator complete box and backup fuse inside panel. This includes wiring from the panel to the light points using a 150-meter for each Site Location, four-core PVC insulated sheathed Cu flexible cable, 1.5 sqmm cable. The installation also covers street points and includes a three-phase starter panel to ensure comprehensive coverage and functionality at Andhra Power House. | 1 | Job | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.11 MB
vol-I.pdf
Tender Documents • 2.38 MB
Vol-II.pdf
Tender Documents • 1.21 MB
BOQ_197200.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid