Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.4 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹97.4 L+₹4.0 L (4.30%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹97.9 L+₹4.5 L (4.84%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹1.0 Cr+₹8.4 L (9.04%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹1.0 Cr+₹10.7 L (11.4%)Rejected-Finance 121004 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹98 L
EMD Value
₹2.0 L
Closing Date
16 Jan 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT OF CENTRAL AC PLANT COMPRESSOR COOLING APPLIANCES COMPREHENSIVE MAINTENANCE OF DIFFERENT TYPE OF ACs AND OTHER ALLIED WORKS AT AFS SULUR
2019_MES_308638_1
GE(AF)/SUL/Token/45 of 2019-2020
Open Tender
Miscellaneous Works
Item Rate
334 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹2.0 L
Yes
21 Feb 2020
21 Dec 2019
17 Jan 2020
21 Dec 2019
16 Jan 2020
10 Jan 2020
23 Dec 2019 - 9 Jan 2020
Amount
SCHEDULE A BOQ
Taking down old unserviceable scroll type compressor of capacity 4.25 TR including supply and replacement of same capacity and model of compressor, Model No. ZR61KCE-TFD-422 of Emerson Climate Technologies make or equivalent make for Opera-I AC Plant
Supply, assembly and erection in replacement of 24 G,GI sheet with rectangular /Square duct made out of ‘L’ shaped hollow profile, duly boxed ,including insulation of duct and all accessories such as fixing bolts, support hanging rods ,support slotted angles, Gasket etc, ducting insulation material will be XLPE with 12mm for supply ducts and 9mm for return ducts ,Material : Closed cell cross cell crosslinked polyolefin foam with alupet foil and self adhesive backing. Foam core 25 Kg/m3 - 75 Sqm
S&F in replacement of grills/diffusers of size 630X630 mm for supply air duct made out of CRCA sheet 1.2mm thick, with perforation duly powder coated etc adjustable type(with flow regulating arrangement all as directed.Make : Microflow ,3C Air Equipments, Deepak cooling.
Supply and fix in replacement of Galvanised steel volume control damper, Opposed/parallel Blade Dampers are used to carry out a rough air system balance with closer control being carried out at the individual grilles or diffusers for supply air. Make : Microflow, 3C Air Equipments, Deepak cooling.
Material for providing insulation on and around suction and discharge copper tube of size 3/8"/ 5/8" with 6mm thick flexible thermocol heat resistance duly warpped with sticking tape and finally covered with flexible PVC conduit of 50mmB2:B20 dia complete all as specified and as directed.
Liquid line drier filter suitable for 4 TR cassette type AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete all as specified and as directed. Note : Supply and charging refrigerent gas will be measured and paid seperately under relavent items. Make of drier filter: LG / Danfoss / Hitech
Taking down and strip opening of old unserviceable sealed unit compressor of any make from cassttee type air conditioner by disconnecting cooling and condensor copper pipe and electric connection carefully and S&F new scroll compressor of capacity 4 ton including charging of refrigerant gas R-22/ R-407C upto required cooling and connecting all the copper pipes, electric connection and testing the AC complete all as specified and as directed. Make : LG/ Danfoss/ Sanyo/ Tecumseh/Kirloskar/ Comipro/Copeland. Note : Supply and charging refrigerent gas will be measured and paid seperately under relavent items
Carrying out pressure leak test of 4 ton cassette type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately
PCB (circuit plate) of in-door unit of 4.0 TR ductable split AC complete all as specified and as directed.
Reverse cycle valve suitable for cassette type AC of capacity 4 Ton complete all as specified and as directed.
Outdoor fan motor suitable for small shaft condensing coil including blade suitable for cassettte AC of 4 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Taking down of defective evaporator unit of 4 TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or equivalent) with blower motor, front grill and connecting the cooper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
S&F in replacement condensing unit of Cassette type AC of capacity 4 TR capacity condensing/ outdoor unit complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerent gas will be measured and paid for separetly.
Thermal relay 15A, 415 Volt, single phase suitable for cassette type AC of 4 TR capacity complete all as specified and as directed. Make : LG / Hitech/Indo Asian/L&T/Tecumseh.
Inspection, checking adjustment and minor repair of unserviceable window type/ split type AC any type any capacity placed at any location includes repair/ replacement of defective parts such as checking of electrical connection, condenser, gas leakage, PCB, condenser fan blade, indoor unit, outdoor unit, compressor, PVC pipe etc., complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
S&F Hermetic sealed/Rotory new compressor for window type AC of capacity 1.5 Ton (in replacement) including disconnecting the electrical and refrigerant connection of defective sealed unit of window type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed Make :- Voltas, LG, Samsung Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Supply and fix old UNSV indoor unit including blower fan , PCB board and all accessaries capacity 1.5/2.0 Ton split type A/C and including taking existing one any type all as specifed and directed by Engineer-in-charge
Blower of indoor unit suitable for 1.5 Ton / 2 Ton split AC and including taking existing one at any location all as specified and directed.
S & F Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of window type AC upto and including 1.5 Ton and replacing the condenser coil unit connecting the same unit with refrigerant connections complete all as specified and directed.
Supply and fixing Remote sensing unit (inreplacement) for upto and including 2.0 TR split type Ac of existing type all as specified and directed. Make : As per existing of AC.
Supply and fixing Blower motor (inreplacement) suitable for window type Air Conditioner of any make up to and including 1.5 TR capacity, all as specified and directed. Make of fan motor: AUE/ GEC/Himsun.
Supply and fixing Blower motor (in replacement) suitable for split type Air Conditioner of any make up to and including 2 TR capacity, all as specified and directed. Make of fan motor: AUE/ GEC/Himsun.
M&L for Refrigerant gas,(R 22) Freon suitable for cooling equipments supplied and filled all as specified and directed.
S & F Copper tube (inreplacement) 15 mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof all as specified and directed
Supply and fixing Over load relay (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5 TR capacity, all as specified and directed.
M & L for pressure testing and rectifying the leakages found in the system of window/split type ACs capacity up to and including 2 Ton capacity including vacumizing,charging and checking the gas pressure to desire level complete for satisfactory functioning all as specified and as directed. Note:Toping up of gas will be measured and paid seperately
M&L for shifting of Air Conditioner, window/Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed by Engineer-in-Charge. Note :- The rate for following works deemed to be included in quoted rate :- (a) Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occuring during shifting of Air Conditioner and topping up of required gas. (j) Fixing of copper tubing of qty of required size.
Supply and fix PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Ton and including taking existing one all as specified and directed.
Supply and fix metal frame stand factory made outdoor type to hold outdoor split unit of Acs all as directed and specified.
Supply and fixing Condenser Fan motor (inreplacement) suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity, all as specified directed. Make of fan motor: AUE/GEC/Himsun.
Supply and fixing Thermostat (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5 TR capacity,all as specified and directed.
Supply and fixing Front grill (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5 TR capacity, all as specified and directed.
Supply and fixing flexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity.
Supply and fix flair nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix flair nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix flair nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix flair nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix flair nut of dia 1/16" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix 3 pin 15 Amps plug top for any type of AC and including taking existing one and all as specified and as directed.
Removing the window/ split type AC upto 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when ordered and installing back at original location, testing and commissioning all as specified and as directed by Engineer-in-Charge. Note :- The rate of following deemed to be included in quoted rate :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary d) Applying one coat of anti corrosive black paint to base plate e) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, materials & labour, tools and plants, and back in on final position complete (f) The work shall be done by a specialized team of Engineer/Technicians of OEM.
S&F Hermetic sealed/Rotory new compressor for split type AC upto and including 1.5 TR capacity (in replacement) including disconnecting the electrical and refrigerant connection of defective sealed unit of window type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed Make :- Voltas, LG, Samsung Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Supply and fixing Remote assembly corded/cordless (inreplacement) for any type and size of split type ACs, upto and including 2.0 TR all as specified and directed.
Supply and fixing Filter (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5 TR capacity all as specified and directed.
S & F PVC insulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size (in replacement) all as specified and directed.
Supply and fix suction valve suitable for 1.5 Ton/2 Ton of split type AC of any make
S & F Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto and including 1.5 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete all as specified and directed.
Supply and fixing Over load relay (inreplacement) suitable for split type Air Conditioner of any make up to and including 2.0 TR capacity, all as specified and directed.
M&L for Refrigerant gas,(R 407C) suitable for cooling equipments supplied and filled all as specified and directed.
S & F Copper tube, 9 mm dia (inreplacement) superior quality suitable for refrigeration and discharge lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof all as specified and directed.
S&F Hermetic sealed/Rotory new compressor for 2 TR split type AC capacity (in replacement) including disconnecting the electrical and refrigerant connection of defective sealed unit of window type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed Make :- Voltas, LG, Samsung Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
supply and fix metal clad socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed .
DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton and including taking existing one capacity and at any locationall as specified and directed.
Supply and fix dummy nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix dummy nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix dummy nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix dully nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC
Supply only overload protector for window/ split AC 1.5/2 Ton TR capacityand including taking existing one all as specified and direced. Make: Indfoss
Supply only condenser fan blade suitable for 1 Ton / 1.5 Ton split/ window AC and including taking existing one and all as specifed and directed.
Supply only pollyurethin form insulation indoor to outdoor unit suilable for 1.5 Ton to 2 Ton split type A/C any type and any location
Multi capacitors 60 µfd for cooling appliances and including taking existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Multi capacitors 36 µfd for cooling appliances and including taking existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Supply and fix discharge valve suitable for 1.5 Ton/2 Ton of split type AC
Supply and fix in replacement of unserviceable MCB 6-32 Amps
S & F Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto and including 2.0 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete all as specified and directed.
Supply and fixing Front grill (in replacement) suitable for split type Air Conditioner of any make up to and including 2 TR capacity, all as specified and directed.
Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto and including 2 TR capacity, all as specified and directed.
Repair and maintenance of inverter type split AC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning all as specified and directed here under :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower. b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower. c) Applying one coat of anti corrosive black paint to base plate (d) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary. (e) The work shall be done by a specialized team of Engineer/Technicians of OEM. (f) Nearly 50 number of inverter type split AC are installed at the distant height. To carryout servicing of these AC's special T&P (Boomer vechice) of height 24 meter will be required. The cost of arrangement of special T&P will be inclusive in quoted rate.
Unserviceable PCB board of inverter type split type AC for 1.5 Ton/2 Ton and including taking existing one at any location all as specified and as directed.
Liquid line drier filter suitable for 8.5 ton ductable AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete all as specified and as directed. Note : Supply and charging refrigerent gas will be measured and paid seperately under relavent items. Make of drier filter: LG / Danfoss / Hitech
Carrying out pressure leak test of 8.5 ton ductable split type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately
Thermal relay 20A, 415 Volt, single phase suitable for ductable split type AC of 8.5 TR capacity complete all as specified and as directed. Make : LG / Tecumseh / Hitech/ Indo Asian/L&T.
PCB (circuit plate) of in-door unit of 8.5 TR ductable split AC complete all as specified and as directed.
Single phase preventor, 230 volt, 50 HZ, AC supply complete all as specified and as directed. Make : L&T / Seimens / Hagger.
Reverse cycle valve suitable for cassette type AC of capacity 8.5 Ton complete all as specified and as directed.
Indoor blower motor for cooling coil including blower suitable for ductable AC 8.5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Wall mount remote kit with wire and complete assembly suitable for ductable AC of 8.5 TR complete all as specified and as directed.
Complete wiring kit for outdoor panel of ductable AC of capacity 8.5 Ton complete all as specified and as directed.
Outdoor fan motor suitable for small shaft condensing coil including blade suitable for ductable AC of 8.5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Disconnecting electric connection from defective blower/ fan motor and taking out from unit capacity 8.5 TR of existing make and transporting to workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burnt winding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding wire as per maunufactrer instructions including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
Taking out of defective wiring of indoor/ outdoor unit of PCB, visual eye damp plates, fixing the new wiring in place of damaged items of capacity of AC 8.5 TR including matching the existing system all as specified and as directed.
Air filter set suitable for 8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech
Low pressure switch for 8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech
AC 4 Pole power contactor three phase of capacity 40 Amp suitable for LG 8.5 TR capacity ductable split type AC complete all as specified and as directed.
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket outside. 3 phase and neutral 400 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/ DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 8-10 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation. Make : Model HTSP 3I7 of safeTrode or equivalent in JEF ECO safe earthing, OBO Betterman/ ENNOV/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre in 02 canes (5 ltrs per cane) for each pit deemed to be included in the quoted rate.
(iii) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( The rate of earthing strip up to 7.5 Mtrs is included in the quoted rate).
(iv) The electrode shall carry manufacturer's name .
(v) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(vi) Testing of earth shall be carried out along with the departmental and user representative and report shall be submitted to Garrison Engineer for his entire satisfaction.
(vii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(x) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xi) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xiii) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(xiv) Resistivity of earth energizer compound and resistance reducing earthing liquid certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
Supply and fixing Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE or equivalent in JEF ECO safe earthing, OBO Betterman/ ENNOV/ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer at the time of sample approval.
Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end
S&F in replacement on distribution board MCCB four pole, 100 Amp ultimate breaking capacity 25 KA, 415V including connecting up using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified. Make : L & T/ Siemens/ ABB
Excavation in trenches exe 1.5m depth and n exc 1.5 mtr in wide in hard/dense soil and getting out.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Fly ash cable protection cover of size 23x11.5 x7.5cm including taking down existing bricks of any size.
XLPE insulated,screened ,PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 70 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
XLPE insulated,screened ,PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 35 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 35 sqmm to 70 sqmm Make : Reychems, Densons
S&F in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA, 415V including connecting up using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified. Make : L & T/ Siemens/ ABB
Supply and Fix Sealed Maintenance Free (SMF) battery of capacity 12 V, 26 AH, suitable for existing 3 phase online UPS as required at location including initial charging complete with inbuilt charger including electrolyte/ distilled water etc including taking down of old battery and shifting to MES store yard for deposit all as directed by engineer in charge complete all as specified. Make of battery : Exide of model No. EP 65 or equivalent in Amar raja (Power Zone)/ Amaron Note :- (i) The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation. (ii) The contractor shall supply SMF battery as per requirement given by Engineer-in-Chare throughout the currency of contract.
Comprehensive repair and annual maintenance of Aqua guards installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters as directed by Engineer-in-charge, for the any models / types, for 11 month period of each aqua guard
Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/200 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
S&F hermetic sealed new compressor (inreplacement) for water cooler 40/80 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
M&L for repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed.
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 40/ 80 litres capacity all as specified and directed.
M&L for preparing the old painted surface of the water coolers of capacity up to 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed.
Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note:Topping up of gas will be measured and paid seperately
Supply and charging of refrigerant gas R-134a to water cooler, refrigerator and deep freezer air conditioner of any type, make and capacity all as specified and directed
Multi capacitors 45 µfd for cooling appliances and including taking existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Multi capacitors 6 µfd for cooling appliances and including taking existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
S&F Condensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed.
PCB Card 12 Volt of DC capacity for Aquaguard incl dismantling old unsv and including taking existing onecomplete all as specified and directed and as directed
Carbon (filter) 12” size incl taking down old unsv all as specified and directed
S&F Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water cooler of any make of 40/80 litres capacity, all as specified and directed. Make of Fan motor: AUE/ GEC/HIMSUN
S&F PVC drain out pipe 30mm dia bore (in replacement) as per existing including providing necessary GI clamps, nut bolt etc.all as specified and directed
S&F Evaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (inreplacement) complete all as specified directed.
Supply and fix in repair PVC connection pipe 450mm long 15 mm dia with brass unions with washers on both the ends all as specified and directed.
S&F Self closing push type Bib tap 15mm dia made out of cast copper alloy chromium plated (inreplacement) suitable for water cooler conforming to ISI mark, including testing and leak proof etc.complete all as specified and directed.
S&F hermetic sealed new compressor (inreplacement) for water cooler 60/120 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
S&F Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water cooler of any make of 60/120 litres capacity, all as specified and directed. Make of Fan motor: AUE/ GEC/HIMSUN
Supply and fix in replacement of gun metal gate valve 15mm dia including GI nipple all as specified and as directed
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note:Topping up of gas will be measured and paid seperately
Candle (filter) 10” size incl taking down old unsv all as specified and directed
S&F ball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity all directed.
Supply and fix in replacement of filter for water cooler of any size any make all as specified and as directed
S&F hermetic sealed new compressor (inreplacement) for water cooler 150/150 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 150 Litres capacity all as specified and directed.
M&L for preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed.
S & F Door gasket (in replacement) suitable for lid of water cooler upto 150 litres capacity, all as specified and directed.
Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note:Topping up of gas will be measured and paid seperately
S&F Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water cooler of any make of 150/150 litres capacity, all as specified and directed. Make of Fan motor: AUE/ GEC/HIMSUN
Comprehensive repair and annual maintenance of Aqua guards installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters as directed by Engineer-in-charge, for Best water doctor model No. HIMA-6 of capacity 50 ltrs Make : KAWIN Water Tech.
Comprehensive repair and annual maintenance of Aqua guards installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters as directed by Engineer-in-charge, for Best water doctor model No.UV PLUS 7 NC of capacity 100 ltrs/Hr .
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 75KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed,Location TRCL plant
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 50KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed , Location T/51 plant
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 75KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed, Location ATC
Comprehensive maintenance of 3 phase oil cooled servo stabilizer with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 75KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location Transmitter plant
Note for Item No 150 to 153 :- (a) In above items, maintenance shall be done through authorised person of OEM. The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. (b) The rate quoted shall be deemed to include for carried out all repairs to servo stabilizer noticed during the period 11 months by providing materials and labour.
Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator 165/ 180/ 175/210/260/280/300/310/320/325 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
Timer and sensor of Refrigerator and including taking existing one complete all as specified and as directed as per Make of Refrigerator
S & F Evaporator coil, suitable for refrigerator of 165 to 255 ltrs any make size and type (inreplacement) all as specified and as directed.
Filter of refrigerator and including taking existing onecomplete all as specified and as directed.
PVC shelf transparent type of tough plastic suitable for refrigerator of capacity 300 ltrs complete and including taking existing one all as specified nd as directed. Make : Godrej/LG/Whirlpool
S&F hermetically sealed new compressor (inreplacement) for 165 to 255 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 255 litres. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
M & L for preparing the old painted surface of refrigerator of capacity 165 litres to 350 litres and spray painting with synthetic enamel paint of approved colour all as specified and directed.
Freezer compartment including door and accessories suitable for refrigeratorr 280,300,310 and 340 ltrs capacity refrigerator and including taking existing one complete all as specified and as directed. Make : Godrej/LG/whirlpool
S & F Chiller tray (inreplacement) suitable for Refrigerator of any make, 165 to 255 litres capacity, all as specified and directed.
S&F inreplacement condensing coil for refrigerator of capacity 165 to 255 Ltr complete all as specified and directed.
S & F Vegetable tray (inreplacement) suitable for Refrigerator of any make, 165 to 255 litres capacity, all as specified and directed.
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 255 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.Note:Topping up of gas will be measured and paid seperately
Multi capacitors 50+5 µfd for cooling appliances and including taking existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Multi capacitors 50+2 µfd for cooling appliances and including taking existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Supply and fix in repair electric bulb 20 watt 230v threaded type for refrigetator of Capacity 200 ltrs to 310 ltrs complete all as specified and directed.
Supply and fix in repair magnetic beading for refrigerator of cap 165 ltrs to 350 ltrs complete all as specified and directed.
S & F inreplacement Gasket, suitable for door of Refrigerator of any make, 165 to 255 litres capacity, fixed in repairs all as specified and directed.
Copper capillary tube suitable for refrigerator and including taking existing one, any description complete all as specified and directed.
Starting relay suitable for refrigerator and including taking existing onecomplete all as specified.and as directed Make : SRIRAM/GODREJ/RANUTROL
Over load protector for refrigerator and including taking existing one, any description complete all as specified and as directed..
S & F Relay, box type, suitable for refrigerator of any make 165 to 350 litres capacity (inreplacement) fixed in repairs, all as specified and directed.
S&F hermetically sealed new compressor (inreplacement) for 260 to 310 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 255 litres. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
S & F Evaporator coil, suitable for refrigerator of 260 to 300 ltrs any make size and type (inreplacement) all as specified and as directed.
S&F hermetically sealed new compressor (inreplacement) for 260 to 310 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 255 litres. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking existing one complete all as specified and as directed. Make : Godrej/LG/whirlpool
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 300 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.Note:Topping up of gas will be measured and paid seperately
S & F Vegetable tray (inreplacement) suitable for Refrigerator of any make, 260 to 310 litres capacity, all as specified and directed.
S & F Chiller tray (inreplacement) suitable for Refrigerator of any make, 260 to 310 litres capacity, all as specified and directed.
S&F inreplacement condensing coil for refrigerator of capacity 260 to 310 Ltr complete all as specified and directed.
Multi capacitors 4 µfd for cooling appliances and including taking existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Multi capacitors 2.5 µfd for cooling appliances and including taking existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
S & F Thermostat, suitable for refrigerator of any make 165 to 350 litres capacity (inreplacement) all as specified and directed.
S & F Evaporator coil, suitable for refrigerator of 308 to 350 ltrs any make size and type (inreplacement) all as specified and as directed.
S&F inreplacement condensing coil for refrigerator of capacity 315 to 360 Ltr complete all as specified and directed.
S&F hermetically sealed new compressor (inreplacement) for 308 to 350 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 308 to 350 litres. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
S&F hermetically sealed new compressor (inreplacement) for 315 to 360 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 315 to 360 litres. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
S & F Chiller tray (inreplacement) suitable for Refrigerator of any make, 315 to 360 litres capacity, all as specified and directed.
S & F Vegetable tray (inreplacement) suitable for Refrigerator of any make, 315 to 360 litres capacity, all as specified and directed.
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 310 to 350 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.Note:Topping up of gas will be measured and paid seperately
S&F ice superior quality plastic/PVC Ice cube tray for refrigerator of cp 200 Ltrs to 310 ltrs complete all as specified and directed.
Multi capacitors 2 µfd for cooling appliances and including taking existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
Supply and fix single phase single pole contactor suitable for 1.5/ 2.0 split type AC all as specified and as directed.
M&L for dismantling the transformer from the voltage stabilizers of following capacity and removing the old / burnt transformer and replaced with new transformer (a) 0.5 KVA
Replacement of following spare parts for 1 KVA to 2 KVA capacity voltage stabilizers (a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
S&F Digital voltmeter 0-250volt (inreplacement) for voltage stabilizers any type as per existing all as specified directed
XLPE insulated,screened ,PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 50 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
XLPE insulated,screened ,PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 16 sqmm & 25 sqmm Make : Reychems, Densons
Supply and lay in road crossing / under floor / on polel etc GI pipe 50 mm bore medium grade for cable protection complete all as specified and as dierced by Engr-in-Charge.
S&F in replacement MCCB four pole, 200 Amp ultimate breaking capacity 36 KA, 415V including connecting up using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified. Make : L & T/ Siemens/ ABB
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket outside. 3 phase and neutral 350 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/ DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25 x 6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, magnesium sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester should be calibrated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
XLPE insulated,screened ,PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. 3 phase and neutral 600 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/ DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 60 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :- (a) MCCB with Thermal magnetic releas, 4 Pole, 400 Amps, 36 KA, 415 Volt, 50 Hz - 01 No (incoming). (Make of switch gear :- L&T, Schnieder, ABB). Make of LT Panel/ FPB shall be as mentioned in list of makes (PS)
Comprehensive maintenance of 3 phase air cooled servo stabilizer with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 15KVA of (Make RDC)including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system as directed by the Engineer -in-charge, Note:-(a) The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. Location RT Cabin
Comprehensive maintenance of 3 phase servo stabilizer with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 10 KVA of Make Adroit including attending day to day complaints , isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge Note:-(a) The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. Location AVRO
Comprehensive Repair & servicing of 2 KVA to 7.5KVA on line UPS of Make BEC with battery with distilled water, attending day to day complaints as directed by the Engineer -in-charge, Note:-(a) The contractor shall make AMC contract with the original manufacturer of UPS and the repairs/maintenance shall be carried out through the original manufacturers only Location - ,28 runwayend,Navy hangar,HRDF hut Note:- For item No 217 to 219 Payment shall be made thrice in a year proportionately, for comprehensive maintenance for the period of 11 months.
Supply and Fix Sealed Maintenance Free (SMF) battery of capacity 12 V, 18 AH, suitable for existing 3 phase online UPS as required at location including initial charging complete with inbuilt charger including electrolyte/ distilled water etc including taking down of old battery and shifting to MES store yard for deposit all as directed by engineer in charge complete all as specified. Make of battery : Exide of model No. EP 65 or equivalent in Amar raja (Power Zone)/ Amaron Note :- (i) The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation. (ii) The contractor shall supply SMF battery as per requirement given by Engineer-in-Chare throughout the currency of contract.
Comprehensive repair and annual maintenance of Aqua guards installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters as directed by Engineer-in-charge, Best water doctor model No. HIMA-6 of capacity 50 ltrs with compressor Make : KAWIN Water Tech.
M&L for pressure testing and rectifying the leakage found in the system of Deep freezer of capacity 320 litres including vacuuming and charging the refrigerantRefrigerant gas R-134 a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.Note:Topping up of gas will be measured and paid seperately
Copper capillary tube of Deep freezer and including taking existing one, any description complete all as specified and as directed.
Starting relay of Deep freezer and including taking existing onecomplete all as specified and as directed. Make- Sriram/Godrej/Ranutrol
Over load protector for Deep freezer and including taking existing one, any description complete all as specified and as directed.
Thermostat for Deep freezer and including taking existing one complete all as specified and as drected. Make : Whirlpool/Renutrol.
S&F hermetic sealed new compressor (inreplacement) 1/6 HP suitable for deep freezer of capacity 320 ltr including disconnecting the electrical and refrigerant connection of defective sealed unit of deep freezer 320 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Filter for Deep freezer and including taking existing onecomplete all as specified and as directed
Condenser fan motor of Deep freezer and including taking existing onecomplete all as specified and as directed.
S & F PVC insulated multi stranded copper conductor 4 core 4 sqmm including connecting up and taking down existing unserviceable cable of any description and size (in replacement) all as specified and directed.
M&L for dismantling the transformer from the stabilizers of 4 KVA and removing the old / burnt transformer and replaced with new transformer
M&L for dismantling the transformer from the stabilizers of 5 KVA and removing the old / burnt transformer and replaced with new transformer
Replacement of following spare parts for 4 KVA to 5 KVA capacity stabilizers (a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
PVC tape roll self adhesive of size 1.90cm x 0.125mm x 25m. Make- Steelgrip, Kinjal, Anchor.
Comprehensive Repair & servicing of 5 KVA single phase on line UPS of Make Aplab with battery ,attending day to day complaints as directed by the Engineer -in-charge, Note:-(a) The contractor shall make AMC contract with the original manufacturer of UPS and the repairs/maintenance shall be carried out through the original manufacturers only Location - New TRCL Bldg(06 Nos),Old TRCL Bldg-04Nos,(i) Any minor items to be replaced is included in the item rate quoted.
Comprehensive Repair & servicing of 10 KVA three phase on line UPS of Make BEC with battery ,attending day to day complaints as directed by the Engineer -in-charge, once in 03 months Note:-(a) The contractor shall make AMC contract with the original manufacturer of UPS and the repairs/maintenance shall be carried out through the original manufacturers only Location - Tarang Lab,(i) Any minor items to be replaced is included in the item rate quoted.
Comprehensive maintenance of 20KVA static frequency converter with input supply of 3 phase 415V,50HZ with output of 115 V,400HZ. of Make Aplab including attending day to day complaints , isolating converter from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. Location CRRW,(i) Any minor items to be replaced is included in the item rate quoted.
Comprehensive maintenance of DC power supply (Rectifier)28 Volts DC Output,15 KW with input supply of 3 phase 415V,50HZ . of Make Aplab including attending day to day complaints , isolating converter from system,Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers only. Location Generator Room,Instrument Rotable section,(i) Any minor items to be replaced is included in the item rate quoted. Note:- For item No 236 to 239 Payment shall be made thrice in a year proportionately, for compehensive mantenance for the period of 11 months.
Supply only Cooling fan suitable for 5 to 25KVA true online UPS and including taking existing one of Make - Aplab all as specified and directed.
Supply only Cooling fan suitable for 40KVA Frequency converter and including taking existing one of as specified and directed Make - Aplab
Supply only Cooling fan suitable for 15 KW/20 KW DC power supply of Make - Aplab
Supply only IGBTsuitable for 40-50KVA true online UPS of Make - Aplab
Supply only IGBTsuitable for 5-25KVA true online UPS and including taking existing one all as specified and directed of Make - Aplab
Supply only Microprocessor board of servostablizer of capacity 50KVA to 250KVA and including taking existing one all as specified and as directed.
Supply only Servo motor suitable for 50 to 75 KVA and including taking existing one of any Make all as specified and directed.
Supply only Buck Boost transformer of servostablizer of capacity 50KVA to 75KVA and including taking existing one of any Make all as specified and directed..
Supply only Bypass switch of servo stabilizer of capacity 50 to75 KVA and including taking existing one of any Make all as specified and directed.
Supply only DC Capacitor suitable for 5 to 50KVA true online UPS and including taking existing one of all as specified and directed. Make - Aplab
Supply only DC Capacitor suitable for 20 to 40KVA Frequency converter and including taking existing one of Make - Aplab all as specified and directed.
Supply only IGBTsuitable for 20-40 KVA Frequency converter and including taking existing one of all as specified and directed Make - Aplab
Supply only IGBTsuitable for 15 KW/20KW DC power supply and including taking existing one of Make - Aplab all as specified and directed.
Taking down old unserviceable scroll type compressor of capacity 6 TR including supply and replacement of same capacity and model of compressor, Model No. ZR48K3E-TFD-422 of Emerson Climate Technologies make or equivalent make for Opera-II AC Plant
M&L for Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance alongwith blower assembly filter and other components including checking electrical connections all as specified and as directed.
M&L for blower motor assembly of Air curtain unit of any type capacity and length, single phase AC, 230 Volts as including electrical connections all as specified and as directed.
Pipe thermister suitable for cassette type AC of capacity 4 Ton complete all as specified and as directed.
Comprehensive maintenance of 25KVA true online UPS system with SMF batteries, with input supply of 3 phase 415V,50HZ . of Make Aplab including attending day to day complaints , isolating UPS from system, Opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of equipment and the repairs/maintenance shall be carriedout through the original manufacturers only. Location CRRW (01 NO), (i) Any minor items to be replaced is included in the item rate quoted.
Comprehensive maintenance of 50KVA true online UPS system with SMF batteries, with input supply of 3 phase 415V,50HZ . of Make Aplab including attending day to day complaints , isolating UPS from system, Opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers only. Location IT section,(i) Any minor items to be replaced is included in the item rate quoted. Note:- For item No 257 & 258 Payment shall be made thrice in a year proportionately, for compehensive mantenance for the period of 11 months.
SUPER COOL
eurekaenterprises
C R R CONSTRUCTIONS
Neptune Engineers and Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .