Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-Finance | ₹20.8 L | L1 | Accepted-Finance Ist Lowest bidder |
| 2 | L2₹21.0 L+₹14,527.02 (0.70%)Accepted-Finance | ₹21.0 L+₹14,527.02 (0.70%) | L2 | Accepted-Finance IInd Lowest bidder |
| 3 | L3₹23.0 L+₹2.2 L (10.5%)Accepted-Finance | ₹23.0 L+₹2.2 L (10.5%) | L3 | Accepted-Finance IIIrd Lowest bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical online paper not submit as per NIT |
| 5 | Rejected-Technical | - | - | Rejected-Technical online paper not submit as per NIT |
| Sl No | Description | Qty | Unit | M/s Ayushi Enterprises L3 | RAJ ENTERPRISES L1 | M/S MOHAMMAD ABBAS L2 |
|---|---|---|---|---|---|---|
| 1.00Detail of Work | ||||||
| 1.01 | Safely cartage of other complete line material, ABC, PVC Cable (Except PCC Poles) from ESC, SRE/ JE store to site of work at various sites including loading, unloading at both ends.( Dist.App. 0 to 50 Km.) | 3.5 | Ton. | 3,500 ₹12,250 | 2,500 ₹8,750 Lowest | 10,507.72 ₹36,777.02 |
| 1.02 | Safe cartage of 250 KVA T/F from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 50 km.) | 12 | No. | 5,500 ₹66,000 | 4,500 ₹54,000 Lowest | 6,000 ₹72,000 |
| 1.03 | Safe cartage of 11 KV Fuse Set from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 50 km.) | 12 | No. | 1,500 ₹18,000 | 500 ₹6,000 Lowest | 500 ₹6,000 Lowest |
| 1.04 | Safe cartage of 11 KV TPMO from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 50 km.) | 12 | No | 1,500 ₹18,000 | 500 ₹6,000 Lowest | 500 ₹6,000 Lowest |
| 1.05 | Safely Installation of Fuse set and connection properly. | 12 | No. | 1,000 ₹12,000 | 500 ₹6,000 Lowest | 1,500 ₹18,000 |
| 1.06 | Safely Installation of 11 KV TPMO and connection properly. | 12 | No | 1,000 ₹12,000 | 500 ₹6,000 Lowest | 1,000 ₹12,000 |
| 1.07 | Constriction of plinth for installation of 250 kv T/F of size 2x2x1.5 mtr made of 9”inch thick wall in all four sides with 6”inch thick RCC top duly filled with sand and plastered 12mm thick in ratio 1:4 with cement and sand on outer surface of brick wall. | 12 | No | 22,000 ₹2,64,000 | 20,000 ₹2,40,000 Lowest | 30,000 ₹3,60,000 |
| 1.08 | Safe installation of 250 KVA T/F on the Plinth with complete fittings including making connections and commissioning. | 12 | No | 5,500 ₹66,000 | 4,500 ₹54,000 | 4,000 ₹48,000 Lowest |
| 1.09 | Wire mesh fencing of 250 KVA T/F size 2.5x2.5x2.5 mt. grouting making frame of MS angle 45x45x6 mm and fixing four no. MS strip size 25x6 mm at equal distance in between the frame and fixing square mesh 50 mm square in each frame the fencing should cover all side of T/F with providing 1 No. door size 6'x3' with sitakni & Dandala with painting of Fencing. | 12 | No | 20,000 ₹2,40,000 | 18,000 ₹2,16,000 Lowest | 25,000 ₹3,00,000 |
Tender Value
₹24.2 L
EMD Value
₹24,500
Closing Date
11 Jun 2026, 12:00 pmClosed
Superintending Engineer
EDC I Saharanpur
Electrification work of Business plan 2026-27
2026_PVVNL_1152922_2
11/W/EDC-I/SRE/2026-27
Open Tender
Electrical Works
Lump-sum
45 days
saharanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Yes
SE EDC I SRE
₹24,500
Yes
22 Jun 2026
27 May 2026
11 Jun 2026
27 May 2026
11 Jun 2026
27 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Detail of Work | |||||
| 1.01 | Safely cartage of other complete line material, ABC, PVC Cable (Except PCC Poles) from ESC, SRE/ JE store to site of work at various sites including loading, unloading at both ends.( Dist.App. 0 to 50 Km.) | 3.5 | Ton. | - | - |
| 1.02 | Safe cartage of 250 KVA T/F from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 50 km.) | 12 | No. | - | - |
| 1.03 | Safe cartage of 11 KV Fuse Set from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 50 km.) | 12 | No. | - | - |
| 1.04 | Safe cartage of 11 KV TPMO from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 50 km.) | 12 | No | - | - |
| 1.05 | Safely Installation of Fuse set and connection properly. | 12 | No. | - | - |
| 1.06 | Safely Installation of 11 KV TPMO and connection properly. | 12 | No | - | - |
| 1.07 | Constriction of plinth for installation of 250 kv T/F of size 2x2x1.5 mtr made of 9”inch thick wall in all four sides with 6”inch thick RCC top duly filled with sand and plastered 12mm thick in ratio 1:4 with cement and sand on outer surface of brick wall. | 12 | No | - | - |
| 1.08 | Safe installation of 250 KVA T/F on the Plinth with complete fittings including making connections and commissioning. | 12 | No | - | - |
| 1.09 | Wire mesh fencing of 250 KVA T/F size 2.5x2.5x2.5 mt. grouting making frame of MS angle 45x45x6 mm and fixing four no. MS strip size 25x6 mm at equal distance in between the frame and fixing square mesh 50 mm square in each frame the fencing should cover all side of T/F with providing 1 No. door size 6'x3' with sitakni & Dandala with painting of Fencing. | 12 | No | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
11w26-27N.pdf
Tender Documents • 0.86 MB
BOQ_2162714.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .