Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Provincial Division, Jhajjar
Providing Estate Water Supply in Govt. College Birohar, Tehsil and District Jhajjar. (Reinvited)
2022_HRY_206357_2
PWD/JJR/Estate Water Supply
Open Tender
Civil Works
Works
180 days
Jhajjar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
₹36,000
Yes
8 Jun 2022
18 Feb 2022
11 Mar 2022
18 Feb 2022
10 Mar 2022
18 Feb 2022
120 days
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (HSR 4.14.1)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m All kinds of soil Pipes, cables etc. exceeding 80 mm metre dia. but not exceeding 300 mm dia (HSR 4.16.1.2) 4" Dia D.I. Pipe
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) : 6 graded stone aggregate 20 mm nominal size) (HSR 6.1.4)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level 1 :4: 8 (1 Cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 40 mm nominal size) (HSR 6.1.6)
Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size) (HSR 6.8.2) 40mm thick
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge All works up to plinth level Extra for providing richer mixes up to plinth and at all floor levels Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) (HSR 6.25.1 + 6.26.1)
Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc(HSR 6.29.2)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies (HSR 6.30.3)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 6.33.6) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.21.2)
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: (HSR 9.11.1) With common burnt clay non-modular brick tile of class designation 10
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18)
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (HSR 9.57.2) 110 mm diameter
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 O mm gap for thermal expansion (HSR 9.58.5.2) Bend 87.5° 110 mm bend
Providing and laying cement plaster skirting up to 30 cm height, with cement mortar 1: 3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. (HSR 10.13.1) 18 mm thick
Providing a floating coat of 1.50 mm thick neat cement laid in one operation to the topping, Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling & Providing and laying of conglomerate floor 50mm thick cement concrete topping 1 :2:4 (HSR 10.14+10.1+10.7)
12 mm cement plaster of mix 1 :6 (1 cement: 6 fine sand) (HSR 11.5.4)
15 mm cement plaster on the rough side of single or half brick wall of mix 1 :6 (1 cement: 6 fine sand) (HSR 11.6.2)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade (HSR 11.64.1) New work (two or more coats) over and including water thinnable priming coat with cement primer
Applying priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works (HSR 11.68.3)
Painting the wooden I metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade (HSR 11.82.1) Two or more coats on new work
Finishing walls with water proofing cement paint of required shade (HSR 11.93.1) New work (Two or more coats applied@ 3.84 kg/10 sqm)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately (HSR 12.7.2.2) Kiln seasoned and chemically treated Hollock wood 30 mm thick shutters
Supply & fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm & Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets & screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1 :2:4 for fixing lugs complete in all respects as per drawing, design, specification & entire satisfaction of Engineer-in-charge. (HSR 13.21.1) Door Frame of size 80mm x 50mm with 37mm wide single rebate metre for 35mm door shutter
Extra for fixing sluice valves/flap valves socketed or flanged including cartage from stores or nearest Railway Station to site of works (HSR 20.10.2) 100 mm i/d
Providing and fixing Cast Iron Detachable Joints class-15 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with 15:5382 & IS:10292 and appropriate number of nut and bolts marked with 15:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) (HSR 20.58.2) 100mm i/d CID Joint
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per 15:8329- 2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. (HSR 20.63.1) 100 mm i/d
Cutting DI pipe and chipping or filling the surface to a uniform finish (HSR 20.66.1) 100 mm i/d
Joining DI socketed pipes, valves and special with rubber tyton joints fitted complete including cost of labour and tools etc. and tested complete (HSR 20.67.1) 100 mm i/d
Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths Ductile Iron (DI) standard specials plain /flanged/ socketed confirming to IS9523-2000 with rubber ring (EPDM/SBR) joints such as tees, bends, tapers, caps etc. with in trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. (HSR 20.68.1) Up to 300mm dia
Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths cast iron (Cl) standard specials plain /flanged/ socketed confirming to IS13382 with rubber ring, nut bolts and rubber sheet such as tees, bends, tapers, caps etc. complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer (HSR 20.69.1) Up to 300mm dia
Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of O to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in fal respect. Make:- L&T, SIEMENS, BCH, SCHNEIDER (HSR 20.114.1)
Supplying, erection, testing and commissioning of Horizontal motor pumping set for clear water having head 40. 00 m as per the indicated requirements of discharge in LPM and power capacity in BHP Make: KSB, CRI, Kirtosker, Crompton Greeve, Lubi) (HSR 20.121.1) 400 LPM 40 Mtr. Head 5 BHP
Providing & fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS : 1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1 :2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge (HSR 21.28)
Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1 :3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge (HSR 21.93.1) Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .