Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC 368 MAHESHPUR OPPOSITE GOVT PRIMARY SCHOOL SECTOR 21 PANCHKULA 134112 HR | PANCHKULA | PANCHKULA | HARYANA | 134112 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹46.8 L+₹7.3 L (18.5%)Rejected-Finance 424 A B GANDHI NAGAR JAMMU AND KASHMIR 180004 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹47.3 L+₹7.8 L (19.7%)Rejected-Finance BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | L4₹58.6 L+₹19.1 L (48.3%)Rejected-Finance | L4 | Rejected-Finance Other than L1 Bidder | |
| 5 | Rejected-Technical 104 SECTOR 4 PANCHKULA HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134112 | - | Rejected-Technical Category not as per NIT |
| Sl No | Description | Qty | Unit | FIRE ENVO SAFETY ENGINEERS L1 | L-7 Primewave Communications L3 | M/S SIMRAN WALIA ENTERPRISES L4 | M/S INOVISION ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|
| 1.01 | Supply, installation, testing and commissioning of Military grade Split Air conditioner of capacity 1.5 TR, Operating voltage: 230V ± 10%, single phase AC electric supply, with indoor and outdoor unit run on remote control , with three mode Heat, cool & ventilation complete all as specified described in the Particular Specification and directed and approved for the makes specified in the Particular Specifications
Following Statutory requirements should be met by the Manufacturer and documents in original to be submitted:
1. Flameproof Split Air Conditioner certification permits installation in Zone 1 or 2 gas group IIA & IIB.
2. Flameproof control panel suitable for direct installation in hazardous area.
3. The air conditioner & its enclosure and the cable gland shall be of explosion proof (Type Ex-d) suitable for use in oilfield hazardous area, Zone-I & Zone-2, and Gas group IIA & II B and shall conform to IS/IEC/EN:60079-0:2011 & IS/IEC/EN:60079-1:2007
4. Test reports conforming to the above relevant standards from an Indian Government Laboratory or NABL accredited laboratory or IECEx accredited laboratory or ATEX notified body, which is not a part of manufacturer’s facility shall be submitted before ordering and at the time of sample approval. | 6 | Each Job | 3,65,000 ₹21,90,000 Lowest | 4,48,000 ₹26,88,000 | 5,75,000 ₹34,50,000 | 4,80,000 ₹28,80,000 |
| 2.00 | Supply, installation, testing and commissioning of Military grade Split Air conditioner of capacity 2 TR, Operating voltage: 230V ± 10%, single phase AC electric supply, with indoor and outdoor unit run on remote control , with three mode Heat, cool & ventilation complete all as specified described in the Particular Specification and directed and approved for the makes specified in the Particular Specifications
Following Statutory requirements should be met by the Manufacturer and documents in original to be submitted:
1. Flameproof Split Air Conditioner certification permits installation in Zone 1 or 2 gas group IIA & IIB.
2. Flameproof control panel suitable for direct installation in hazardous area.
3. The air conditioner & its enclosure and the cable gland shall be of explosion proof (Type Ex-d) suitable for use in oilfield hazardous area, Zone-I & Zone-2, and Gas group IIA & II B and shall conform to IS/IEC/EN:60079-0:2011 & IS/IEC/EN:60079-1:2007
4. Test reports conforming to the above relevant standards from an Indian Government Laboratory or NABL accredited laboratory or IECEx accredited laboratory or ATEX notified body, which is not a part of manufacturer’s facility shall be submitted before ordering and at the time of sample approval. | 3 | Each Job | 4,85,000 ₹14,55,000 Lowest | 5,44,000 ₹16,32,000 | 6,95,000 ₹20,85,000 | 5,05,000 ₹15,15,000 |
| 3.00 | Supply and Fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170V to 250 Volt with output voltage stabilized at 230v with accuracy of + 2.5% and of capacity of 7.5 KVA complete all as specifed and as directed by Engineer-in-Charge. Make - V guard /AE/ Godrej/ Vintek Electronics (VOLINA) | 6 | Each Job | 8,000 ₹48,000 Lowest | 15,000 ₹90,000 | 10,500 ₹63,000 | 12,000 ₹72,000 |
| 4.00 | Supply and Fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170V to 250 Volt with output voltage stabilized at 230v with accuracy of + 2.5% and of capacity of 10 KVA complete all as specifed and directed..Make - V guard /AE/ Godrej/ Vintek Electronics (VOLINA) | 3 | Each Job | 9,000 ₹27,000 Lowest | 30,000 ₹90,000 | 20,000 ₹60,000 | 18,000 ₹54,000 |
| 5.00 | Supply and fix time switches 250V single phase of 32 Amp rating with contactor fitted inside steel enclosure complete all as specifed and as directed by Engineer-in-Charge. | 9 | Each | 8,000 ₹72,000 | 10,000 ₹90,000 | 8,000 ₹72,000 | 3,500 ₹31,500 Lowest |
| 6.00 | S&F Sheet Metal Enclouser with socket plug top & MCBs with a two pin and earth plug and socket of 32 Amp complete with double pole MCB complete all as specifed and as directed by Engineer-in-Charge. Make -. .Make LEGRAND/ HAVELLS/ABB/L&T | 6 | Each | 2,000 ₹12,000 Lowest | 2,000 ₹12,000 Lowest | 2,000 ₹12,000 Lowest | 2,500 ₹15,000 |
| 7.00 | M & L for Triple pole , Neutral and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB sheet metal encloser with socket plug & MCB 32 Amp complete all as specifed and as directed by Engineer-in-Charge. | 3 | Each | 2,500 ₹7,500 Lowest | 5,000 ₹15,000 | 5,000 ₹15,000 | 5,000 ₹15,000 |
| 8.00 | Supply & Fix sub main wiring of 2x10.0 sq. mm + 1x10.0sq. mm earth wire sqmm PVC insulated unsheathed FR cable multistranded copper conductor with earth wire of 10 sqmm PVC insulated unsheathed FRLS cable multistranded copper conductor including Stove enamelled steel conduit complete all as specifed and as directed by Engineer-in-Charge. | 60 | RM | 1,200 ₹72,000 | 900 ₹54,000 | 800 ₹48,000 | 700 ₹42,000 Lowest |
| 9.00 | Supply & Fix sub main wiring of 4x6.00 sq. mm + 1x6.00 sq. mm earth wire sqmm PVC insulated unsheathed FR cable multistranded copper conductor with earth wire of 06 sqmm PVC insulated unsheathed FRLS cable multistranded copper conductor including Stove enamelled steel conduit complete all as specifed and as directed by Engineer-in-Charge. | 30 | RM | 600 ₹18,000 Lowest | 700 ₹21,000 | 600 ₹18,000 Lowest | 665 ₹19,950 |
| 10.00 | Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in Hard/Dense soil complete all as specifed and as directed by Engineer-in-Charge. | 5.65 | Cum | 600 ₹3,390 | 500 ₹2,825 Lowest | 500 ₹2,825 Lowest | 900 ₹5,085 |
Tender Value
₹43.8 L
EMD Value
₹87,580
Closing Date
28 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Devdutt Deshpande
GE (AF) Thoise
PROVN OF INDUSTRIAL AC WITH STABILIZER, TIMER AND ASSOCIATED INFRASTRUCTURE AT E-ROOM AND STN AR AT AF STN THOISE UNDER GE (AF) THOISE
2025_MES_707972_2
GEAF/T-22/E8
Open Tender
Civil Works
Item Rate
120 days
THOISE STATION
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Thoise
₹87,580
Yes
30 Nov 2025
12 Jul 2025
30 Jul 2025
12 Jul 2025
28 Jul 2025
14 Jul 2025
Amount
Supply, installation, testing and commissioning of Military grade Split Air conditioner of capacity 1.5 TR, Operating voltage: 230V ± 10%, single phase AC electric supply, with indoor and outdoor unit run on remote control , with three mode Heat, cool & ventilation complete all as specified described in the Particular Specification and directed and approved for the makes specified in the Particular Specifications Following Statutory requirements should be met by the Manufacturer and documents in original to be submitted: 1. Flameproof Split Air Conditioner certification permits installation in Zone 1 or 2 gas group IIA & IIB. 2. Flameproof control panel suitable for direct installation in hazardous area. 3. The air conditioner & its enclosure and the cable gland shall be of explosion proof (Type Ex-d) suitable for use in oilfield hazardous area, Zone-I & Zone-2, and Gas group IIA & II B and shall conform to IS/IEC/EN:60079-0:2011 & IS/IEC/EN:60079-1:2007 4. Test reports conforming to the above relevant standards from an Indian Government Laboratory or NABL accredited laboratory or IECEx accredited laboratory or ATEX notified body, which is not a part of manufacturer’s facility shall be submitted before ordering and at the time of sample approval.
Supply, installation, testing and commissioning of Military grade Split Air conditioner of capacity 2 TR, Operating voltage: 230V ± 10%, single phase AC electric supply, with indoor and outdoor unit run on remote control , with three mode Heat, cool & ventilation complete all as specified described in the Particular Specification and directed and approved for the makes specified in the Particular Specifications Following Statutory requirements should be met by the Manufacturer and documents in original to be submitted: 1. Flameproof Split Air Conditioner certification permits installation in Zone 1 or 2 gas group IIA & IIB. 2. Flameproof control panel suitable for direct installation in hazardous area. 3. The air conditioner & its enclosure and the cable gland shall be of explosion proof (Type Ex-d) suitable for use in oilfield hazardous area, Zone-I & Zone-2, and Gas group IIA & II B and shall conform to IS/IEC/EN:60079-0:2011 & IS/IEC/EN:60079-1:2007 4. Test reports conforming to the above relevant standards from an Indian Government Laboratory or NABL accredited laboratory or IECEx accredited laboratory or ATEX notified body, which is not a part of manufacturer’s facility shall be submitted before ordering and at the time of sample approval.
Supply and Fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170V to 250 Volt with output voltage stabilized at 230v with accuracy of + 2.5% and of capacity of 7.5 KVA complete all as specifed and as directed by Engineer-in-Charge. Make - V guard /AE/ Godrej/ Vintek Electronics (VOLINA)
Supply and Fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170V to 250 Volt with output voltage stabilized at 230v with accuracy of + 2.5% and of capacity of 10 KVA complete all as specifed and directed..Make - V guard /AE/ Godrej/ Vintek Electronics (VOLINA)
Supply and fix time switches 250V single phase of 32 Amp rating with contactor fitted inside steel enclosure complete all as specifed and as directed by Engineer-in-Charge.
S&F Sheet Metal Enclouser with socket plug top & MCBs with a two pin and earth plug and socket of 32 Amp complete with double pole MCB complete all as specifed and as directed by Engineer-in-Charge. Make -. .Make LEGRAND/ HAVELLS/ABB/L&T
M & L for Triple pole , Neutral and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB sheet metal encloser with socket plug & MCB 32 Amp complete all as specifed and as directed by Engineer-in-Charge.
Supply & Fix sub main wiring of 2x10.0 sq. mm + 1x10.0sq. mm earth wire sqmm PVC insulated unsheathed FR cable multistranded copper conductor with earth wire of 10 sqmm PVC insulated unsheathed FRLS cable multistranded copper conductor including Stove enamelled steel conduit complete all as specifed and as directed by Engineer-in-Charge.
Supply & Fix sub main wiring of 4x6.00 sq. mm + 1x6.00 sq. mm earth wire sqmm PVC insulated unsheathed FR cable multistranded copper conductor with earth wire of 06 sqmm PVC insulated unsheathed FRLS cable multistranded copper conductor including Stove enamelled steel conduit complete all as specifed and as directed by Engineer-in-Charge.
Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in Hard/Dense soil complete all as specifed and as directed by Engineer-in-Charge.
Returning filling in including spreading levelling, watering and well ramming in layer each not exc. 25 cm thick in a soft/loose soil complete all as specified and directed by Enginer-in-Charge.
Removing surplus soil to a distance not exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for PCC cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specifed and as directed by Engineer-in-Charge. Note:-Excavation and earth work to be measured and paid for separately
M&L Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cm thick, complete all as specifed and as directed by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strrip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25sqmm 4 Core, laid in trenches or passing through pipes including suitable lugs and accessories for making connections at both endscomplete all as specifed and as directed by Engineer-in-Charge.
M/S INOVISION ENTERPRISES (BID ID -3364902)
L-7 Primewave Communications (BID ID -3367163)
M/S SIMRAN WALIA ENTERPRISES (BID ID -3368061)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .