Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹28.0 L+₹2.0 L (7.81%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹31.8 L+₹5.9 L (22.6%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹33.3 L+₹7.3 L (28.1%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹33.4 L+₹7.5 L (28.8%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹35.5 L
EMD Value
₹71,000
Closing Date
19 Apr 2022, 6:00 pmClosed
GE I R AND D GIRINAGAR PUNE 411025
GE I R AND D GIRINAGAR PUNE 411025
REPAIR MAINT OF HT LT SYSTEM TRANSFORMERS LT PANELS OH LINES LT UG CABLES STREET LIGHT FITTINGS SECURITY LIGHTS GATE GATE LIGHTES GARDEN LIGHTES AND ALLIED WORKS IN RESIDENTIAL AND TECHNICAL AREA AT DIAT DU AND MILIT GIRINAGAR PUNE 25
2022_MES_515315_1
GE I R AND D GNR TOKEN NO 68 OF 2021 2022
Open Tender
Civil Works
Works
270 days
GE I R AND D GIRINAGAR PUNE 411025
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE I R AND D GIRINAGAR PUNE 411025
₹71,000
Yes
29 Dec 2023
25 Mar 2022
21 Apr 2022
25 Mar 2022
19 Apr 2022
7 Apr 2022
25 Mar 2022 - 4 Apr 2022
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Soft / loose soil including forming bottom surface etc complete all as specified & directed.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete in soil complete all as specified & directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 50 mtr above the starting point complete all as specified & directed.
Material and labour for cutting of bituminous road / floor for laying of pipe / cables 45 CM wide and not exceeding 1.5 meter deep including refilling / with material and watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed.
Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size couplers for jointing of pipe all as per site requirement complete all as specified & directed.
Supply & Laying 75 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size copulers for jointing of pipe all as per site requirement complete all as specified & directed.
M &L for GI pipe light grade in repair for road crossing / on wall / on pole for cable protection complete all as specified & directed of following size:- Make: TATA/JINDAL/ PRAKASH SURYA. a) 50 mm dia
b) 80 mm dia
M & L to find out fault in LT line bring/call fault finding machine equipment and find out fault in any size of LT UG Cable including disconnecting of cable connection from both side panels/poles and necessary excavation in any type of strata to reach upto cable and making space for cable joint complete all as specified & directed. Note:- (i) Cable required at site same size of faulty cable if required for jointing purpose will be paid in relevant item. (ii) Jointing material will be paid in relevant Item.
M & L to find out fault in HT line bring/call fault finding machine equipment and find out fault in any size HT UG Cable including disconnecting of cable connection from both side panels/poles and necessary excavation in any type of strata to reach upto cable and making space for cable joint complete all as specified & directed. Note:- (i) Cable required at site same size of faulty cable if required for jointing purpose will be paid in relevant item. (ii) Jointing material will be paid in relevant Item.
Supply and jointing straight through joint, 22000 volts grade heat shirnkable type suitable for 3 core to 95 Sqmm, HT, XLPE cable and testing after jointing all as specified and directed. Make :3M / M Seal / Denson / Reychem
Supply and fix in repair straight through cable jointing kit 22 KV earthed grade heat shrinkable joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as specified & directed Make :3M / M Seal / Denson / Reychem
Material and labour for dismantling old cable end termination and supply and jointing new Cable end termination heat shrinkable outdoor type suitable for 22KV, 95 Sqmm XLPE, 3 Core power cable with aluminium conductor complete all as specified & directed. Make :3M / M Seal / Denson / Reychem
Material and labour for dismantling old cable end termination and supply and fixing new Cable end termination heat shrinkable outdoor type suitable for 22KV, 120 Sqmm to 185 sqmm, XLPE, 3 Core power cable with aluminium conductor complete all as specified & directed. Make :3M / M Seal / Denson / Reychem
Material and labour for dismantling old cable end termination and supply and fixing new Cable end termination touch proof type outdoor type suitable for 22KV, 95 Sqmm to 185 sqmm, XLPE, 3 Core power cable with aluminium conductor complete all as specified & directed. Make :3M / M Seal / Diwop/Hong shang/GCA
M & L for cable jointing kit for 22 KV earthed graded cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 185 sqmm complete all as specified & directed. Make :3M / M Seal / Denson / Reychem
Taking down the existing defective HT UG cable of following size in trenches / pipes / pole for attending the repair,jointing materials, refixing / relaying back in trenches fixed on poles complete all as specified and directed . (a) 95 sq mm 3 core upto 185 sqmm 3 core. Note-: (i) Excavation and earth work will be measured and paid seperately under relevant item. (ii) Old U/S cable shall be the property of contractor and will be measured in Sch of credit
Supply and laying HT UG Cable of size 185 sqmm 3 core heavy duty 22000 volts grade with aluminium conductor strip armoured PVC insulated and PVC sheathed incl jointing material etc. Laid in trenches / ducts / fixed on wall / pole or drawn through pipes complete all as specified directed.
Taking down the existing defective LT UG cable of following size in trenches / pipes / pole for fault finding /attending the repair and repair the same all as specified and directed . (a) 6 sq mm 2/3/3.5/4 core upto 50 sqmm 3/3.5/4 core.
(b) 95 sq mm x3.5 core upto 300 x3.5 core sqmm. Note-: (i) Excavation and earthwork shall be measured & paid separately under relevant item. (ii) If the existing cable become faulty and can not be useful, then cable/joint kit shall be provided by contractor as supply and fix . Retrived cable shall be handed over to contractor as schedule of credit.
Supply & fix heat srinkable jointing kit for 1.1 KV grade cable for straight through joint/ end joint kit complete with jointing material and accessories suitable for 2/3.5/4 core XLPE / PVC armoured AIuminium Conductor cable of following size . Make: DENSON / MAHINDRA / REYCHEM / 3M . (a) 16 sqmm to 25 sq mm
(b) 50 sqmm to 70 sq mm
(c) 70 sqmm to 95 sq mm
(d) 120 sqmm to 185 sq mm
(e) 240 sqmm to 300 sq mm
Supply and lay LT PVC/XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade of following cross-sectional area including cable lugs, jointing materials etc., laid in trenches fixed on poles or laid through GI pipes including taking down old cable complete all as specified & directed. Note-: (i) Excavation and earth work will be measured and paid seperately under relevant item. (ii) Old U/S cable shall be the property of contractor and will be measured in Sch of credit. (a) 2 core 6 sq. mm
(b) 2 core 10 sq. mm
(b) 2 core 16 sq. mm
(c) 4 core 16 sq. mm
(d) 3.5 Core sec. area 25 sq. mm
(e) 3.5 Core sec. area 35 sq. mm
(f ) 3.5 Core sec. area 50 sq. mm
(h) 3.5 Core sec. area 95 sq. mm
(k) 3.5 Core sec. area 185 sq. mm
(l) 3.5 Core sec. area 240 sq. mm
(m) 3.5 Core sec. area 300 sq. mm
M&L for strengthening and Restringing of HT/LT over head ACSR conductor of any size in overhead lines inlcuding removing and replacement of binding wire from insulators and triming the branches on both / above side of the line before,stringing and rebinding of insulators after stringing complete all as specified and as directed .
Dismantling of old unserviceable stay assembly including stay wire complete all as specified and directed. (Note- Cost of necessary demolition of concrete, excavation and earth work shall deemed to be included in quoted rate)
M & L for fixing L T Pole Stay assemblies comprise of stay clamp, stay wire( 7/ 2.24MM), stay insulator, stay grips, thimble staybow, on existing 20 mm dia stay rod (including excavation ,concrete and stay plate ) complete all as specified and directed.
Dismanlting of old jumper, including supply and fixing new jumper connection at cut point on HT / LT over head line with suitable size of ASCR conductor 6 / 1 x 3.00 mm (ferrel) PG Clamps, lugs, alkathine sleaves complete of required length not exceeding 3 mtr inlcuding testing on completion complete all as specified and as directed.
M&L for ACSR conductor on existing poles including dismantling of unsv ACSR conductor all as directed and as specified.
Servicing the 22 KV GOD by cleaning the contact, disc/pin insulator with CTC & applying the petrolium jelly at the contact point/down rod links for smooth operation including replacing the rusted/corroted bolts & nuts and defective insulator of GOD as required at site complete all as specified and directed. (Note :- Insulator shall be measured and paid separetely under relavant items.
M & L for Male / Moving contact ( set of 3 Nos )
M & L for Female / Fixed contact ( set of 3 Nos )
M & L for Copper tinned strip ( set of 3 Nos )
Material and labour for dismantling old U/S AB switch and Supply, installation. connecting electrically & commissioning switch air break, gang operated, tripple pole mounted on insulators 15 Nos with drop out fuse and steel frame with operating mechanism in working from ground level, including jumper connection with ACSR conductor alongwith PVC pipe covering with colour code between main supply and GOD complete all as specified and directed for current rating upto 200 amps and working voltage 22000 volts all as required at site complete all as specified and directed. Make: Jaipuria/BHEL
All as per item No 28.00 above but of capacity 400 amps
Cutting / trimning of Tree branches which are touching to HT / LT over head lines and clearing the same up to 4 meter radius for span length not exceeding 45 to 55 meter complete all as specified and as directed. (Note: Each span of 45-55 Mtrs will be considered as one length of span for payment purpose)
M & L for painting of steel tubular LT pole up to 9 mtr long with two coats of aluminium paint incl cross arms (for single pole), clamps etc complete including marking of pole No with black paint with all arrangement for ladder etc all as specified and directed.
M & L for fixing of line seprator suitable for LT line four conductor feeder complete all as specified & directed.
M & L for fixing of line seprator suitable for LT line three conductor in horizontal /vertical feeder all as specified & directed.
Isolate/de-energize the supply to the HT/LT Panel Board of capacity ranging from 200 Amps to 2000 Amps, opening the doors/covers of the cubicle enclosure for carrying out the servicing/maintenance/repairs of the Panel Board, switch gear, metering etc and re-fixing the same in place after repairs including testing and commissioning of the panel board comprising of the following:- a) Cleaning the inside switch gear chambers for removing dust, carbon and rusted surfaces including cleaning with blower and apply insulating varnish. b) Check the condition of the DMC/SMC support insulators including cleaning applying Dr beck red for better IR values and replacement of insulators if required. c) Tightening up of all bus bar connections, cable connections, replace bolt, nuts wherever required. Note : Contractor has to inspect the site before quoting. Any modifications/frame work and renewal is deemed to be included in the quoted rates. Spares will be measured and paid under relevant items of schedule
S&F in repair mild steel hinges suitable for LT panel board shutters including welding, riveting complete all as specified and as directed.
Disconnecting and taking out old existing worn out control wiring connections including cable lugs of LT panel board of 4 wire system and supply and connect with new cable PVC insulated, stranded copper conductor 2.5 sqmm including with new copper lugs and nuts, bolts, washers complete all as specified and directed.
Disconnecting and taking out old existing worn out cable lugs, nuts, bolts, washers etc from LT panel board of 4 wire system (incomming and outgoing) and supply and connect with new aluminium lugs all sizes as per site requirement and nuts, bolts, washers etc complete all as specified and directed.
Material and labour for dismantling of old steel tubular pole and supply, errecting in truly vertical position steel tubular swaged pole 11 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative white & black strips of 30 cm width upto 1.5 mtr above ground level all as required at site complete all as specified & directed.
Material and labour for dismantling of old steel tubular pole and supply, errecting in truly vertical position steel tubular swaged pole 9.0 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative white & black strips of 30 cm width upto 1.5 mtr above ground level all as required at site complete all as specified & directed.
M & L for Surface excavation not exceding 30 cm deep in hard dense soil and averaging 15 cm deep and getting out green vegetation, roots, bushes, etc surrounding of 2 / 4 / 6 pole structure / substations / RMU complete all as specified & directed.
M&L for PCC 1:4:8 Type D2 (using 40 mm graded aggregate) in foundation including form work and finishing the exposed surface of concrete even and smooth complete all as specified and directed.
M & L for PCC 1:3:6 type, type C-2 (using 40 mm graded aggregate) in foundation of stay, for making good the disturbed portion of road/floor/platform etc including necessary form work complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded aggregate) for coping of pole including necessary formwork complete all as specified and directed.
S& F in replacement of MCCB 3 Pole 63 Amps 16 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 3 Pole 100 Amps 16 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 3 Pole 160 Amps 25 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 4 Pole 200 Amps 25 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 4 Pole 250 Amps 25 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 4 Pole 400 Amps 36 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 4 Pole 630Amps 36 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 4 Pole 800Amps 50 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S & F in replacement of ACB type manual fixed with microprocessor based LSIG & tempreture rise protection consisting of digital display with battery backup 3 ph ,4 pole , 415 Volts, 630 Ampr 50KA in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly testing of ACB all as specified and directed . Make: Legrand-DMX3-Cat No: 028730 or equivalent in ABB/Siemens
S & F in replacement of ACB type manual fixed with microprocessor based LSIG & temprature rise protection consisting of digital display with battery backup 3 ph ,4 pole , 415 Volts, 800 Ampr 50KA in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly testing of ACB all as specified and directed . Make: Legrand-DMX3-Cat No: 028731 or equivalent in ABB/Siemens
S & F in replacement of power contactor 4 pole , 415 Volts, 630 Ampr AC1 with integrated auxiliary contacts and coil voltage 200-240V AC/DC in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly all as specified and directed . Make: Legrand/ ABB/Siemens/L&T
S & F in replacement of power contactor 4 pole , 415 Volts, 800 Ampr AC1 with integrated auxiliary contacts and coil voltage 100-240V AC/DC in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly all as specified and directed . Make: Legrand/ ABB/Siemens/L&T/Indo asian
S&F in replacment of 3 phase digital multi function meter with suitable accessories and fixing arrangements complete all as specified & directed. Make : L&T, Cat no CORNEL 4380 or its equivalent
S&F in replacment of voltmeter/Ammeter of range 0 to 500 Volts complete all as specified & directed.
S&F in replacament of LED type phase indicator to be fitted on panel ( R,Y, B as per site requirement) complete all as specified & directed.
M&L for dismentling and disconnecting the ACB rating 800/630 amps Make: Crompton greaves/ C&S/ L&T by carrying out repairs/ servicing, checking and renewing the defective shunt trip coil & UV trip 415 volts AC, checking and rectifying the defective CTs and rectifying the mechanism operation including spring charging system, reinstalling the same in the panel and providing necessary line and connections complete all as specified & directed.
Material and labour for dismantling of old danger notice plate and supply and fixing danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts & nuts of approved size of 20 x 15 cm size complete all as specified & directed.
M & L for Scraping of old paint from two pole structure without removing accessories and preparation of surfaces for repainting. painting of 4 pole structure with two coats of aluminium paint incl channels, DO fuse parts, clamps etc complete including marking of pole No with black paint with all arrangement for ladder and painting of bottom portion of the pole upto 1.0 m from top of the copping with one coat of synthetic enamel red paint over a coat of red oxide primer etc complete all as specified & directed.
Supply & fix HT fuse element 22 KV fibre glass type suitable for folloiwng :- (Make EADC/Equivalent/vidhut) (a) 22 KV 50 Amps
(b) 22 KV 60 Amps
Disconnecting all the electrical connections from H.T.and L.T. side of unserviceable transformer of cap above 160 KVA to 500 KVA i.e. Jumpers/cable from the cable end box or bushings & earthing terminal of the transformers, loading and unloading of transformer & transportation by vehicle from substation to the repairing workshop including reinstallation, commissioning and testing complete all as specified & directed.
Opening the transformer cover along with the conservator by removing the nut bolts then after removing the internal HT.& LT connections by taking them out by removing studs, bushings, taking out the core-winding assembly out of the tank removing out burnt HV and LV windings from the core assembly,Draining & decanting of burnt transformer oil and cleaning of sludge deposited in the tank with CTC of transformer having ratio 22/0.433 KV . Rewinding of HV and LV coils with suitable size super enamelled copper wire / strip ( As Existing ) having suitable class insulation material . Heating of core winding assembly in hot chamber for 48 hours and remove all the moisture present in it , removal of leakage of tank if any by welding, refilling transformer oil to tank , after putting the core-winding assembly into the tank, reassembling making the internal H.T. & L.T. connections by fixing the studs, bushings,fitting the top cover by replacing cork sheet gasket along with conservator, testing the transformer in the workshop, all as directed by Engineer-in-charge.for various capacities as under :- a) upto 160KVA
b) All as per item no 65.00 above 160KVA to 500 KVA
Supply only super enamelled copper winding wire / strip of any size for H.T coils of transformers including providing insulation.
Supply only copper winding wire/ strip of any size for L.T. coils of transformers including providing insulation all as required.
Reconditioning of LT coil of copper wound transformer by turning the old paper insulations, straightening the entire LT Strip providing new paper insulations of superior quality and making coil of suitable design as original all as specified and directed.
Supply & fix HT Bushing(as per sample)
Supply & fix LT Bushing(as per sample)
Supply & fix brass stud (for LT433V side)of suitable size complete with one chuck nut, two nuts, washers and rubber seal, all as per sample for outdoor type transformer of the capacity as under:- a) upto 160 KVA
b) All as per item no 71.00 above 160KVA upto 250KVA
c) All as per item no 71.00 above 250KVA upto 500KVA
Supply & fix brass stud (for HT 22KV side) of suitable size complete with one chuck nut, two nuts, washers and rubber seal, all as per sample for outdoor type transformer of the capacity as under:- a) upto 160KVA
b) All as per item no 72.00 above 160KVA upto 250KVA
c)All as per item no 72.00 above 250KVA upto 500KVA
Scrubing of old rusted paint from transformer and preparation of surfaces for fresh painting, by means of spray painting with two coats of synthetic enamel paint of approved colour of transformer up capacity 100 KVA to 500 KVA and writing SM No/MES No of the transformer etc complete all as specified and as directed.
M&L for dehydration of transformer oil with mobile transformer oil filtration plant at site with all accessaries connected to transformer and carrying out filteration of oil for desired dielectric strength i.e. not less than 40 KV at 2.5mm gap complete all as specified & directed. Note :- 1. Test certificates shall be submitted before and after filteration for dielectric strength on the proper format .
M & L for replacement of breather assembly of transparent plastic body with top and bottom portion pressed with metalic cover, filled with silica jel blue in colour and suitable for pipe entry of 15/20/25mm dia as per the site requirement complete all as specified and directed.
Supply and Filling/ topping up new transfermer oil of approved make conforming to IS- 335 / 1983 including testing of IR value of the oil not less than 60 KV, complete all as specifaied and as directed. Make : Power Oil/ HP/ BP
M&L for earth testing, identifying the earthings in system and recording the results on indicator board and producing three copies of test sheet duly signed by Contractor/ JE/ AGE E/M complete all as specified & directed. Note :- (i) Cost of labour and tools required for testing is deemed to be included in quoted rate.
M&L for earthing with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to galvanised strip 32x6mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 40mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering complete all as specified and directed.
M&L for earthing with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to GI Earth wire 4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 20 mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering complete all as specified and directe.
M&L for earthing with copper plate electrode 600x600x3.15mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to copper strip 20x3 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 40mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering complete all as specified and directed.
M&L for hard core of broken stone or boulders of gauge n. exc. 40 mm, deposited, spread and leveled in layers n. exc. 200 cm thick, watered and rammed to a true surface complete all as specified & directed.
S&F in replacement of timer switch 16 Amps, 230 Volts, 24 hrs dial type for operation with by pass operation complete all as specified & directed. Make :- Legrand Cat No 6499 15, MaxiRex 4QT (daily) or equivalent in GIC/L&T/ Indoasian
S&F in replacement of triple pole power contactor suitable for 40 Amps, with coil voltage 230 Volts complete all as specified & directed. Make: L&T/ Siemens.
Supply and fix outdoor type FRP junction box light weight suitable for pole mounting includin flat iron clamp duly painted with two coats of aluminium paint over a coat of red oxide primer and GI nut, bolts, washers and necessary connector for loop in loop out cable connection and suitable size galnds, of size 250x200x105 mm complete all as specified & directed. Make - Syntex/ Anchor
Supply and fix inreplacement of 3 x 1 sq mm PVC Cercular copper cable for connection of street light fitting, Security light fitting, post top lantern and garden light fitting and including all fixing arrengenment with proper fixing complete all as specified & directed.
Dismentling and taking down existing any type ( Street light/Bulk head/ Tube light) fitting fixed on bldgs/poles /wall.
S & Fix LED Street light fitting 90 Watts High performance IP 66 LED street light luminaires with complete acessories all as specified and directed . Make - Wipro Cat part no :- LR02-102-XXX-57-G2 or eqvt in Bajaj/ Havells/Crompton.
S & Fix LED Street light fitting 60 Watts High performance IP 66 LED street light luminaires with complete acessories all as specified and directed Make - Wipro Cat part no :- LR02-671-XXX-57-G2 or eqvt in Bajaj/ Havells/Crompton.
Supply & fix LED 35W decorative post top lantern for 360 degree indirect light, made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection, resistance to impact and corrosion, glare free and better uniformity all as directed and specified. Make- Wipro Cat No - LP07-431-XXX-57-CL or equivalent in Crompton/Philips/Havells/Bajaj
Supply & fix LED 40W decorative post top lantern for 360 degree indirect light, made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection, resistance to impact and corrosion, glare free and better uniformity all as directed and specified. Make- wipro Cat No - LP07-431-XXX-57-CL or equivalent in Crompton/Philips/Havells/Bajaj
M & L for replacement of unserviceable MS clamp with new clamp as per sample/as per site requirement made out of MS flat iron 25 x 5mm including fixing nuts bolts, vashers etc and painting with two coats of syntetic enamel paint over a coat of red oxide primer complete all as specified & directed.
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitalable for street light fitting of size 90 Watt complete all as specified & directed. Note- Quoted rate include replacement of driver and testing and making fitting serviceable to entire satisfication of JE/Engr-in-Charge.
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitalable for street light fitting of size 60 Watt complete all as specified & directed. Note- Quoted rate include replacement of driver and testing and making fitting serviceable to entire satisfication of JE/Engr-in-Charge.
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitalable for street light fitting of size 30/45 Watt complete all as specified & directed. Note- Quoted rate include replacement of driver and testing and making fitting serviceable to entire satisfaction of JE/Engr-in-Charge.
M&L for PCC 1:2:4 type B2 (using 40 mm granded granite stone aggregate) in foundations , filling and mass concrete complete including shifting the transformer using by the crane and complete the transformer platform against shifting the transformer on the platform all as specified and directed.
Dismentling and taking down existing any type unserviceable parts and complete overhauling of High galvanised mast light suitable for 6 to 9 lantern symmetricaliy fitted along with their control gear having two point suspention system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly,aviation obstruction light, lightning arrester spike complete all as specified and directed. NOTE :- Spares shall be measured and paid separately as supply only under relevant item here in below.
Supply only spares for item No 96.00 above. (a) Rope SWR 6mm .
(b) Gear motor
(c) 5 core cable
(d) fitting 180 watt Make Havells
M& L for VCB Cleaning, Greasing mechanism, Old greasing cleaning, Checking Electrical Motor, Checking & tight control connection, Checking Charging Mechanism, Greasing Moving part and mechanism, Checking Electrical Motor, Checking HT Cable Connection, Checking Boots, Earth Switch ON OFF Operation, Checking shunt coil, Checked Functions of relay Schneider Electric Make Relay Testing: Overload Current, Short circuit Ground Fault, CT R Phase, Y Phase CT, B Phase CT, Control Wiring Checking VCB Panel Heater Installation (Per Panel 2 heaters 200Watt) : Control Wiring , MCB serviceable complete to satisfication of JE/Engr-in-Charge.
Supply only spares for item No 98.00 above. (a) HT Tape
(b) HT joint kit suitable for HT VCB panel complete all as specified and directed.
(c) Relay suitable for HT VCB panel complete all as specified and directed. make schneider
(d) Tripping coil
(e) CT suitable for HT VCB panel complete all as specified and directed.
(f) Heater suitable for HT VCB panel complete all as specified and directed.
Supply & Laying synthetic rubber insulated mat 3mm thick for voltage up to 22 KV for electric shock safety of size 2X1m. complete all as specified and as directed.
Material and labour for dismantling of old steel tubular pole and supply, errecting in truly vertical position steel tubular swaged pole 8.5 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative white & black strips of 30 cm width upto 1.5 mtr above ground level all as required at site complete all as specified & directed.
Supply & fix cylinder capacitors for following sizes as per existing capacitor bank panel including all fixing arrengement with proper fixing complete all as specified & directed. Make : Havells & Epocs (a) 15 KVAr
(b) 10 KVAr
(c) 7.5 KVAr
(d) 5 KVAr
(e) 3 KVAr
sagar construction
metro electrical services
SKS Electricals
SONU ENTERPRISES
Goodluck Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .