Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 CrAccepted-AOC 15 281 CHHILI INT ROAD GHATIYA AZAM KHAN AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | ₹8.4 Cr Quoted ₹8.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹9.9 Cr+₹1.4 Cr (16.8%)Rejected-Finance | ₹9.9 Cr+₹1.4 Cr (16.8%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹10.8 Cr+₹2.3 Cr (26.8%)Rejected-Finance | ₹10.8 Cr+₹2.3 Cr (26.8%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹11.2 Cr+₹2.7 Cr (32.0%)Rejected-Finance NOT SPECIFIED | ₹11.2 Cr+₹2.7 Cr (32.0%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹12.2 Cr+₹3.7 Cr (44.1%)Rejected-Finance | ₹12.2 Cr+₹3.7 Cr (44.1%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹9.5 Cr
EMD Value
₹8 L
Closing Date
11 Oct 2022, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune PIN- 411001
COMPLETION OF INCOMPLETE WORK FOR PROVISION OF AUDITORIUM CUM CINEMA HALL AT PUNE
2022_MES_540929_1
CA NO - CEPZ/PNA/TOKEN-07 OF 2022-23
Open Tender
Civil Works
Lump-sum
280 days
Pune
Class S
Category a(i)
Also refer NIT
8 documents required · 8 mandatory
₹3,000
GE (Central) Pune
₹8 L
Yes
24 Nov 2022
26 Jul 2022
13 Oct 2022
26 Jul 2022
11 Oct 2022
27 Sept 2022
27 Jul 2022 - 10 Aug 2022
Amount
PHASE-I
NOTE: Schedule ‘A’ Part I to Part-XIII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-13 only.
Total amount of Sch 'A' Part-I (Building works)
Total amount of Sch 'A' Part-II (Internal Electrification)
Total amount of Sch 'A' Part-III (Internal Water Supply)
Total amount of Sch 'A' Part-IV (Lightening Protection)
Total amount of Sch 'A' Part-V (Fire Fighting)
Total amount of Sch 'A' Part-VI (External Electrification)
Total amount of Sch 'A' Part-VII (External Water Supply)
Total amount of Sch 'A' Part-VIII (Road, Path & Culvert)
Total amount of Sch 'A' Part-IX (Area Drainage)
Total amount of Sch 'A' Part-X (Sewage Disposal)
Total amount of Sch 'A' Part-XI (Compound Wall and Gate)
Total amount of Sch 'A' Part-XII (Excavation, Earthwork & Site Clearance)
SCH 'A PART XIV (Miscellaneous B/R and E/M works)
Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only.
Supply and fix modular metal flush box 4 module of size 5" x 3" for modular type wiring complete all as specified and directed by the Engineer-in-charge.
Supply and fix modular metal flush box 6 module of size 8" x 3" for modular type wiring complete all as specified and directed by the Engineer-in-charge.
Supply and fix modular metal flush box 8 module of size 5" x 5" for modular type wiring complete all as specified and directed by the Engineer-in-charge.
Supply and fix modular metal flush box 12 module of size 8" x 6" for modular type wiring complete all as specified and directed by the Engineer-in-charge.
Supply and fix modular cover plate 4 module of size 5" x 3" for modular type wiring complete all as specified and directed by the Engineer-in-charge.
Supply and fix modular cover plate 6 module of size 8" x 3" for modular type wiring complete all as specified and directed by the Engineer-in-charge.
Supply and fix modular cover plate 8 module of size 5" x 5" for modular type wiring complete all as specified and directed by the Engineer-in-charge.
Supply and fix modular cover plate 12 module of size 8" x 6" for modular type wiring complete all as specified and directed by the Engineer-in-charge.
Supply and fix Blanking plate for covering gap in plates complete all as specified and directed by the Engineer-in-charge.
Supply and fix LED recess mounted, 18 W LED 6000K (suitable for 200mm x 200mm size POP/Gypsum board false ceiling), with extruded aluminium heat sink, control gear, Poly Carbonate extruded diffuser & integrated electronic driver 230 V etc. with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and length from ceiling rose to connector of fitting complete all as specified and directed.
S&F WALL MOUNTED MIRROR LIGHT WITH LED 15W Decorative wall mounted die-cast Aluminium LED fixture with ivory powder coating for updown accent lighting 6W LED 3000K including connecting up with twin core twisted flexible copper conductor cable with suitable size and length from ceiling rose to connector of fitting complete all as specified and directed.
S&F CEILING MOUNTED PORCH LIGHT WITH 1X 9W LED Surface decorative wall/ceiling mounted LED fixture with electronic driver suitable for Porch. 5W LED 6000K including connecting up with twin core twisted flexible copper conductor cable with suitable size and length from ceiling rose to connector of fitting complete all as specified and directed.
S&F recess mounted 1x7 Watt LED square downlighter with aluminium extrusion square ring and MS powder coated white housing and separate replaceable electonic driver etc all acessories prewired including connecting up with twin core twisted flexible copper conductor cable with suitable size and length from ceiling rose to connector of fitting complete all as specified and directed.
S&F Supply and fix LED tube light fitting 1x22 watt, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic drivers including LED tube rod of 22 watt with colour temprature 6000K etc including three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block complete with prewired all as specified and directed.
S & F ceiling fan 5 star rating BEE mark with the fan hook/box, 1200 mm (48") sweep and connecting up complete with & including electronic regulator and including three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of reqd length from ceiling rose to connector block of the fan, complete all as specified and directed. Make :- Havells Cat Part No ES-50 or equivalent model in Crompton/Bajaj.
Supply and fix wall mounted fan 400 mm sweep, 1330 RPM, oscilation type with built in regulator complete all as specified and directed. Make :- Havells Model Sameera or equivalent model in Crompton/Bajaj.
S & F exhaust fan, single phase, heavy duty, metallic body, 300mm sweep, 1400 RPM including louvers & fixing of mounting frame in the round hole cutting in the wall, by means of rugged bolts, nuts and washers etc, including three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of the exhaust fan complete all as specified and directed. Make :- Havells model Turbo Force SP or equivalent model in Crompton/Bajaj.
S & F exhaust fan, single phase, heavy duty, metallic body, 380mm sweep, 1400 RPM including louvers & fixing of mounting frame in the round hole cutting in the wall, by means of rugged bolts, nuts and washers etc, including three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of the exhaust fan complete all as specified and directed. Make :- Havells model Turbo Force SP or equivalent model in Crompton/Bajaj.
Supply & fix LED security light luminaire 15 W Energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07 and connecting up with cable, including 1.5 m long GI bracket, bent to shape, clamp and nut bolts of suitable size complete all as specified and as directed. Make:- Havells cat part No LHEWEBP7PL6S015 or equivalent model in Phillips/Bajaj/CG as approved by GE.
Supply, installation, testing and commissioning Indoor type CPRI Approved LT panel board factory fabrication totally enclosed, double door, made out of 2.0 mm thick CRCA sheet metal of suitable size with MS angle iron frame made out of 50x50x6 mm, hinged panel board opening handles, locking arrangements, fully compartments used cut to size rivetted, welded, bent to shape and cubical fabricated truly to box type, dust proof and vermin proof, provide sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provide PVC rubber bushes to spare holes, chromium incoming and outgoing provide aluminium bus bar using aluminium strips of adequate size extendable at both ends for current carrying capacity as in given below with back up kit kat fuse protection rating giving below for phases and ball capacity for neutral entire cubical treated with primer and duly epoxy powder coated internally as well as externally, 3phase, 4 wire, 415 volts, 50 cycles system, including grouting panel legs in PCC 1:2:4 type B-1, complete with danger notice board with and including the following controls and accesories:-
(a) Aluminium bus bar TPN 415 V, 400 A capacity - 1 set
INCOMER
(b) MCCB 4 pole adjustable, 250 Amp, 415 Volts 16 KA - 1 No
OUTGOING
(c) MCB TPN upto 32 Amps, 415 Volts 16 KA - 20 Nos
(d) Cable glands of suitable size for cable as per incomming and outgoing
(e) Indicating lamps (Set of 3 Nos) - 1 set (R, Y & B)
(h) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with terminal lugs.
(j) Interconnection of bus bar and switch fuse/contactor with suitable size copper cable / strip of suitable size and fixing material and colour code PVC sleeves etc.
S&F MCB TPN 415 Volts 6-32 Amp 10 KA 'C' series complete all as specified and directed.
S&F MCB SP & N 240 Volts 6-32A Amp 10 KA 'C' series complete all as specified and directed.
S&F MCB SP 240 Volts 6-32 Amp 10 KA 'C' series complete all as specified and directed.
M & L for Earthing with 600x600x6.00 mm Galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5 m below ground level, connected to and including Galvanised steel Strip of size 32x6 mm by means of bolts, nuts and check nuts and washers of galvanised steel with and including 40 mm dia GI medium grade pipe for protection of GI strip to the extent of 7.5 metres as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical Plate No. 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover with provision of locking arrangement and 20 mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed. Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
M & L for Earthing with 600x600x3.15 mm Copper earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5 m below ground level, connected to and including Copper Strip of size 25x3 mm by means of bolts, nuts and check nuts and washers of copper with and including 40 mm dia GI medium grade pipe for protection of GI strip to the extent of 7.5 metres as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical Plate No. 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover with provision of locking arrangement and 20 mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed. Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
Supply and fix flame proof switch rotary type FLP-WP, made out of cast aluminium alloy with spin loaded cover, inter locking arrangement, cable emties and 4 way open strip type terminal including wiring upto terminals and connecting complete all as specified nad directed. Make :- Cat No : RI/OA/1010 in Sudheer or equivalent model in Bajaj/Baliga as approved by GE.
External Water Supply
Supply, laying, jointing & testing DI-K7 class with spigot and socket, suitable for Push on rubber joint, with internal cement mortor lining, and external zinc and black bitumen coated pipes in any lengths conforming to IS:8329-2000 including Rubber Gasket & joints as per IS:9523-2000 laid in trenches/ Road/ Ducts/ Footpath/ on wall/ on floor locations for 100 mm dia pipe complete all as specified and directed.
NOTE for DI pipes :- DI fittings required shall be measured and paid separately under respective items of this tender.
S & F PP-R Gate valve (Brass insert) of grade PN-25, SDR-7.4, 3 layered (outer green coloured UV stabalized, middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property) fusion welded PP-R (Polypropyelene random copolymer) gate valve brass, light weight ISI marked as per pre requirement of the site with handle screwed both ends for PP-R Pipes of outer dia 90 mm or for unions complete all as specified and as directed.
M & L for Drilling of bore well 150 mm dia in any type of soil or hard rock by rotary fastening method or any other approved method by GE for depth not exc 60 m for each bore well at the location approved by Garrison Engineer based on the soil investigation report from Central water deptt and disposal of water & material complete all as specified and directed by the Engineer-in-charge.
M & L for Drilling of bore well 150 mm dia in any type of soil or hard rock by rotary fastening method or any other approved method by GE for depth exc 60 m but n exc 150 m for each bore well at the location approved by Garrison Engineer based on the soil investigation report from Central water deptt and disposal of water & material complete all as specified and directed by the Engineer-in-charge.
Notes for Bore well items :- The unit rate quoted for drilling of bore well shall deemed to be included for the following :- 1. Conducting survey for exact location of well shall be carried out by any recognized university or central ground water survey department or any institution approved by the Govt. 2. Collection of sample from tube well for every 5 m depth and submission of bore well strate chart. 3. Collection of water samples from bore well and getting then tested for chemical and bacteriological analysis from recognized institution approved by Govt. 4. Conducting yield test of successful bore well for 8 hours/day continuously for three days. 5. Grouting and sealing of bore well for disinfection by using chlorine solution.
S & F MS galvanised casing cap for pipe 4 mm thick of size 150 mm dia complete all as specified and as directed.
Supply, lowering and fixing PVC casing pipe suitable for 150 mm dia bore, ISI marked, to with stand the pressure 6 Kg/Cm2 complete all as specified and as directed.
Supply, Installing, testing & commissioning of submersible pump set for 3 phase 50 cycles 415 volts of 7.5 HP capacity designed to the yeild and head obtained in the bore complete all as specified and as directed.
Supply and lay submersible copper conductor cable 3 core x 6 Sqmm 1100 volts multistranderd PVC insulated PVC sheathed heavy duty flexible cable lowering along with submersible pump set in the bore well with necessary binding with wire to GI pipe complete all as specified and as directed.
Supply and lowering galvanised steel water tubing 50 mm dia Heavy grade cut into 3.0 m length including providing of threading on both sides including 6" long GI socket & fittings for connection and lowering submersible pump set into the bore well complete all as specified and as directed.
Supply & fix reflux valve (non return type) 50 mm dia Gun metal drilled and both ends flanged pattern complete all as specified and directed.
Supply, installation, testing and commissioning Outdoor type CPRI Approved LT panel board factory fabrication totally enclosed, double door, made out of 3.15 mm thick CRCA sheet metal of suitable size with MS angle iron frame made out of 50x50x6 mm, hinged panel board opening handles, locking arrangements, fully compartments used cut to size rivetted, welded, bent to shape and cubical fabricated truly to box type, dust proof and vermin proof, provide sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provide PVC rubber bushes to spare holes, chromium incoming and outgoing provide aluminium bus bar using aluminium strips of adequate size extendable at both ends for current carrying capacity as in given below with back up kit kat fuse protection rating giving below for phases and ball capacity for neutral entire cubical treated with primer and duly epoxy powder coated internally as well as externally, 3phase, 4 wire, 500 volts, 50 cycles system, including grouting panel legs in PCC 1:2:4 type B-1, complete with danger notice board with and including the following controls and accesories:-
Supply and fix MS clamps made out of 50 x 12 mm fiat iron of 0.5 inch dia fixed with 3 inches long bolts and nuts including 02 Nos of washers for each bolts suitable for fixing GI delivery pipe 50 mm dia of submersible pump complete all as specified and as directed.
M& L for construction of valve pit of size 90x90x90 cm internal dimensions with 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded broken stone aggregate) sub base of floor, 50 mm PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in floor finished even and fair without using extra cement, one brick thick brick work in CM 1:4 , 15 mm thick plaster in CM 1:4 including 3 mm thick MS sheet pit cover fixing with angle iron frame 40x40x6 mm thick complete with locking arrangement having provision of lifting handle including 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surface and excavation in soft/loose soil, returning filling and removal of surplus soil up to 50 mtr distance complete and all as specified and directed.
M& L for construction of valve pit of size 60x60x60 cm internal dimensions with 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded broken stone aggregate) sub base of floor, 50 mm PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in floor finished even and fair without using extra cement, one brick thick brick work in CM 1:4 , 15 mm thick plaster in CM 1:4 including 3 mm thick MS sheet pit cover fixing with angle iron frame 40x40x6 mm thick complete with locking arrangement having provision of lifting handle including 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surface and excavation in soft/loose soil, returning filling and removal of surplus soil up to 50 mtr distance complete and all as specified and directed.
S & F DI Connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth, bends, tapers, tees, single, pieces (Single or double branch) any type and angle/radius and straight connecting pieces upto 100 mm bore complete and all as specified and directed.
External Electrification
Supply,laying, testing and commissionnig of UG HT cables, 11000 volts grade, 3 core 120 sqmm (Earthed), XLPE insulated and PVC shealhed, steel wire armoured, with multi stranded aluminum conductor, heavy duty conforming to latest relevant IS, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed.
Supply,laying, testing and commissionnig of UG HT cables, 11000 volts grade, 3 core 95 sqmm (Earthed), XLPE insulated and PVC shealhed, steel wire armoured, with multi stranded aluminum conductor, heavy duty conforming to latest relevant IS, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed.
Supply and fix straight through jointing kit for 11 KV (Earthed) grade cable, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed.
Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for outdoor termination (cold shrink type) joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of of size 120 sqmm complete all as specified and directed.
Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for outdoor termination (cold shrink type) joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of of size 95 sqmm complete all as specified and directed.
Supply, install, testing & commissioning of Vacuum Circuit Breaker HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear having rupturing capacity 350 MVA consits of PTs, CTs, Voltmeter, Ampere meter, indication lamps, frequency meter, PF indication with Over Current, Surge Current & earth fault protection relay and 4 ways annunciator window- 02 Nos, heaters and of rating 630 Amp back with DC supply (including Battery bank of suitable capacity and rating as per manufacturer recommendations). The VCB shall be complete with all standard fittings and accessories, gauges etc., and conforming to relavent IS complete all as specified and directed. Note :- Rate quoted shall deemed to be included for foundation of VCB as per manufacturer instructions.
Supply, install, test and commission step down transformer, outdoor type, and conforming to IS 1180:2014, plinth mounted, HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/star connected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating of capacity 630 KVA including bushing on HT end cable box on LT side. The Transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil IS 335 ISI marked filtered & dehydrated oil etc, complete all as specified and directed and comprising of the following accessories :- Note :- Transfomer shall be mounted on platform/plinth.
(a) One cable box on primary HV side having cable glands suitable for OH conductor(consisting of 3 Nos porcelain HT bushings with brass/gun metal bushing rods complete with nuts and washers).
(b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing LT armoured cables of suitable size.
(c) Oil conservator tank with filter type, drain valve and oil level gauge.
(d) Dehydrating breather with first fill of dehydrating agent.
(e) Thermometer pocket on tank cover.
(f) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device.
(g) Rating plate with terminal markings.
(h) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6m GI eath strip.
(j) Oil Level gauge.
(k) Oil drain and filter valves.
(l) Oil filler hole with cap/plug with connections complete.
(m) Lifting lugs.
(n) Air relief valve plug.
(o) Four plan solid cast steel detachable rollers.
(p) First fill of fresh oil conforming to relvant IS and tested upto 50 KV dielectric strength upto top of core.
(q) Extra bushing for neutal outside the LT cable box for providing independent earthing for neutral.
(r) Provision of 2 Nos danger boards 250x200mm size made out of 1.6mm thick MS plate, vitreous enameled white, with letters, figures of vltage and conventional skull and bones in signal red colour, one at HT side and other on LT side.
(s) Any other fittings/accessories so as to confirm the whole transformer to IS-1180 Part-I:2014.
(t) Construction of Plinth of size 2.0mx 2.0mx1.5m for transformer, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete, flyash brick masonry in CM 1:6, the top of the plinth shall consist of 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface with and including 25 cm thick stone aggregates of size 12.5 mm all around upto and including 1.5 m from the edge of the plinth including the RCC Gate and fencing with angle iron post in lieu of RCC post complete all as specified, directed by the Engineer-in-charge and as shown on TD drawing No CEPZ/98/TD/6, Sheet No 2/2.
Supply,laying, testing and commissionnig of UG LT cables 1100 volts grade, XLPE insulated and PVC shealhed, armoured, with multi stranded aluminum conductor, heavy duty conforming to latest relevant IS, including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material of required size, cables laid in trenches/ducts/under plinth floors passing through pipes, fixed on wall etc,complete of following sizes :-
(a) 3.5 Core, 400 Sqmm
(b) 3.5 Core, 300 Sqmm
(c) 3.5 Core, 185 Sqmm
(d) 3.5 Core, 150 Sqmm
(e) 3.5 Core, 120 Sqmm
(f) 4 Core, 16 Sqmm
(g) 4 Core, 10 Sqmm
(h) 4 Core, 6 Sqmm
(j) 2 Core, 10 Sqmm
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire of capacity 45 watts including high power LEDs of capacity 45 watts as light source and electronic driver with pre wired and necessary mounting arrangements and provision of 6 sqmm twin core copper conductor cable multi stranded from fitting to junction box and including necessary GI pipe medium braket of required dia 1.5 mtr long bend to required shape with suitable MS clamps, bolt, nuts complete all as directed by Engineer- in-charge.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire of capacity 60 watts including high power LEDs of capacity 60 watts as light source and electronic driver with pre wired and necessary mounting arrangements and provision of 6 sqmm twin core copper conductor cable multi stranded from fitting to junction box and including necessary GI pipe medium braket of required dia 1.5 mtr long bend to required shape with suitable MS clamps, bolt, nuts complete all as directed by Engineer- in-charge.
Supply, fix for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 65 protection including LED of capacity 40 watt complete with all accessories fixed on GI pipe 50 mm dia complete all as specified and directed.
S & F Junction Box for Street Lights of size 300 x 250 x 150 mm made out of CRCA sheet 2 mm thick totally enclosed, dust and vermin proof, rain, protected slanted roof top, door pasted with rubber gasket, water tight IP 42 protection single leaf shutter in front having proper locking arrangements epoxy powder coated and suitable size of "connect well" stud teriminal (provision for socket bolting) - 05 Nos suitable for 415 volts, 50 Hz, 3 phase-4 wire internal wiring system including MCB SP 06 amps - 01 No and mounted on security light pole with suitable bracket nuts, bolts complete all as specified and directed.
S & F Mushroom shape Integral decorative LED bollard 9 watt with IP 65 protection including 9 watts LED bulb with necessary elecrical connections with adequate size of Nuts and Bolts including taking down existing unserviceable fitting complete as all specified and as directed.
Supply, installation, testing and commissioning Outdoor type CPRI Approved LT panel board factory fabrication totally enclosed, double door, made out of 3.15 mm thick CRCA sheet metal of suitable size with MS angle iron frame made out of 50x50x6 mm, hinged panel board opening handles, locking arrangements, fully compartments used cut to size rivetted, welded, bent to shape and cubical fabricated truly to box type, dust proof and vermin proof, provide sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provide PVC rubber bushes to spare holes, chromium incoming and outgoing provide aluminium bus bar using aluminium strips of adequate size extendable at both ends for current carrying capacity as in given below with back up kit kat fuse protection rating giving below for phases and ball capacity for neutral entire cubical treated with primer and duly epoxy powder coated internally as well as externally, 3phase, 4 wire, 500 volts, 50 cycles system, including grouting panel legs in PCC 1:2:4 type B-1, complete with danger notice board with and including the following controls and accesories:-
BUSBAR:- 1600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance.
INCOMING
(i) ACB 4 Pole 1000 Amps, Draw- out type circuit breaker with Microprocessor based ET6L Trip Unit with thermal memory, Fully rated neutral with in built protection, ET6L provides Over load, Shortcircuit, Instantaneous & Earth-fault protections, Short circuit breaking capacity 50kA @440 volts AC, Conforms to IS/ IEC60947-2&3 - 01 No.
(iv) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, B phase - 01 SET.
(v) Digital frequency meter 40-60 Hz - 01 No.
(vi) Copper wound with CTR 1000/5 - 03 Nos.
OUT GOING
(i) ACB 4 Pole 630 Amps, Draw- out type circuit breaker with Microprocessor based ET6L Trip Unit with thermal memory, Fully rated neutral with in built protection, ET6L provides Over load, Shortcircuit, Instantaneous & Earth-fault protections, Short circuit breaking capacity 50kA @440 volts AC, Conforms to IS/ IEC60947-2&3 - 01 No.
(ii) MCCB 4 Pole 200 Amps, Rotary Handle, adjustable Thermal Magnetic relay with breaking capacity 25 KA at 415 volts Ics=100% Icu - 02 Nos.
(iii)MCCB 4 Pole 100 Amps, Rotary Handle, adjustable Thermal Magnetic relay with breaking capacity 25 KA at 415 volts Ics=100% Icu - 01 No.
(iv)MCCB 4 Pole 63 Amps, Rotary Handle, adjustable Thermal Magnetic relay with breaking capacity 25 KA at 415 volts Ics=100% Icu - 02 Nos.
(v) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 06 SET.
Supply, installation, testing and commissioning Outdoor type CPRI Approved LT panel board factory fabrication totally enclosed, double door, made out of 3.15 mm thick CRCA sheet metal of suitable size with MS angle iron frame made out of 50x50x6 mm, hinged panel board opening handles, locking arrangements, fully compartments used cut to size rivetted, welded, bent to shape and cubical fabricated truly to box type, dust proof and vermin proof, provide sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provide PVC rubber bushes to spare holes, chromium incoming and outgoing provide aluminium bus bar using aluminium strips of adequate size extendable at both ends for current carrying capacity as in given below with back up kit kat fuse protection rating giving below for phases and ball capacity for neutral entire cubical treated with primer and duly epoxy powder coated internally as well as externally, 3phase, 4 wire, 500 volts, 50 cycles system, including grouting panel legs in PCC 1:2:4 type B-1, complete with danger notice board with and including the following controls and accesories:-
BUSBAR:- (i) 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance.
INCOMING
(i) MCCB 4 Pole 250 Amps, 50 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 1 Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir, Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No.
(iv) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, B phase - 01 SET.
(v) Digital frequency meter 40-60 Hz - 01 No.
(vi) Copper wound with CTR 250/5 - 03 Nos.
OUT GOING
(i) MCCB 4 Pole 100 Amps, Rotary Handle, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts ics=100% Icu - 01 No.
(ii) MCCB 4 Po!e. 63 Amps;Rotary Handle, Adjustable Thermal Magnetic relay with breaking capacity 16 KA. at 415 volts ics=100% Icu - 04 Nos.
(iii) Auto control time switch, timer control for different 24 hours adjustable type including power contractor of capacity 63 amps complete - 01 No.
(iv) MCB 4 Pole 32 Amps with breaking capacity 10 KA at 415 volts - 04 Nos.
(v) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 04 set.
Supply and install automatic power factor correction (APFC) panel factory made of 200 KVAR capacity ready to use design confiring to relevant IS rated for short circuit rating of 50.KA, front openable and lockable by keys having lowers and air vent, gasket and totally vermin proof and suitable for 415/ 440 Volts, 3 phase 50 Hz, AC and housed in elegant, enclosure fabricated from minimum 3.15 mm thick CRCA sheet and min 1.6 mm thick for partitions anti corrosive coating to achieve power factor from 0.9 to 0.99 and epoxy powder coated in texture seimens gray RAL 7032 including suitable size and length of copper conductor cable from main panel to APFC panel for connections complete all as specified, as approved and directed by the Engineer-in-charge.
M & L for Cutting of existing main road/hard standing up to a size not exceeding 25 cms in width and not exceeding 01 m in depth for laying of HT/LT UG cable/protection pipe line making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type C1 incliuding neccesary permission from concered authority i.e PMC or cantonment board complete all as specified and as directed.
S & F Solar street light fitting IP 65 aluminium pressure die cast stand alone LED type fitting with and including LED of capacity 21 Watts induding MS pole 6 mtr long duly painted with two coats of aluminium paint over and including a coat of primer, battery box made out of 2 mm thick precoated GI sheet of suitable size for installing the battery of capadty 12 volts 100 Ah low maintenance lead add tubular battery with 36 hours back up duly approved by MNRE with charger controller 12 V 8.0 A with efficiency 92 % made out of IP 65 protection enclosure, control circuit for dusk to down operation, solar panel of capacity 100 Wp, solar cells made out of Polycrystalline silicon cells with min 14 Wo efficiency of IP 65 fully powder coated frame structure, flexible to tilt to any angle at site, 6 mtr galvanised tubular pole and duty circle including necessary electrical connection and LED lumainaire 12 V, 21 Watts with driver efficiency 92 % complete all as specified and as directed. Make : - Philips Model No BRP - 402 or any other equivalent model in Bajaj/Wipro/Havells as approved by GE.
Supply install testing and commissioning Silent type Diesel Engine Generating set 415 volts 350 KVA 3 -phase 0.8 power factor 50 Hz, 1500 RPM self exicited self regulated brs+B234hless AC generator installed including accoustic enclosure suitable for ambient condition at Pune and confirming to condition under IS 4722, 10001/10002, 13364, BS 5514/2613/5000 with following :-
(A). Alternator :- Standard design alternator rated at 350 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000, IS: 13364 and shall be in position to generate supply with frequecy regulation with in + 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722.
i) Insualation class - 'H'
ii) Temparature rise Class - 'H'
iii) Excitation : Self Excited
iv) Regulation performance: The voltage is kept constant with + 1%, manual voltage adjustment within + 5% .
v) Frequency regulation + 1%
(B) Diesel Engine: - Adquate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details water cooled to drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexiable coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS -10001/10002/ 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:-
i) Fly wheel with housing
ii) Cooling system :- Moulded radiator with fan & belts.
iii) Cooling Water pump :
iv) Exhaust System :- Exhaust System complete with exhaust piping upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclousre.
Exhaust gas turbo charger type
Exhaust manifold
Silencer : Residual type
Bellows
iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated/ (as recommended by OEM) for 1% speed /frequecy regulation.
Fuel fileters
Fuel hoses
v) Lub oil System :-
Lubricating oil filter
Lubricating oil pump
vi) Air Intake System :-
Air intake Manifold
Air cleanler dry type
vii) Governer electronic / (as recommended by OEM)
viii) Starting System :- Electric Self starter with and including battary charging alternator.
ix) Battaries :- Battaries of maintenece free of capacity as recommended by the manufacturer complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified and :
Starter gear ring
Start and stop push button
Ignition key / Switch
Handling and operation : Salient features of accessories shall be as under:
Radiator with blower fan
Corrosion inhibitor coolant
Paper element filters for fuel, lub oil and by pass.
Governer electronic (as recommended by OEM) controlled direct fuel injection system
Fly wheel housing and fly wheel.
x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display.
xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine.
xii) Coupling arrngement : - Flexiable coupling, fly wheel to suit flexiable coupling.
xiii) Accessories :- AVM Pads built or separtely mounted to manufactrer base frames as per (as recommended by OEM)
xiv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes.
xv) Fuel Tank :- Daily service fuel tank (as recommended by OEM) with caliberated level indicating arrangement, stop cock, drain plug, complete on a common base in side the accoustic enclosure.
C) Rubber Matting of LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control panel shall be provided.
D) Accoustic Enclosure:- Manufactured by OEM suitable for 350 KVA DG Set.
(i) NAL approved as per CPCB
(ii) It shall be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.
(iii) The generating set battaries and control panel shall be inside the enclosure.
(iv) Fuel tank shall be in side the enclosure.
(v) Construction Details/specification are as follows : -
a) Outer body :- CRCA Sheet of 1.6mm thick.
b) Doors :- CRCA sheet of 1.6 mm thick
c) Sound Insulation :- 100 mm thick rock wool (64kg/Cum)
vi) The accoustic shall be composite in construction and fully assembled integral unit.
vii) The battaries shall be placed inside the enclosure beside the DG Set on a suitable inlsulated plat form.
viii) The DG Set shall be provided with external Emergency stop push button.
ix) The enclosure shall be suitably illuminated by CFL/FTL Lamp fittings.
x) The noise level shall be 75 Db at 1m under free field conditions.
xi) The accoustic enclosure parts shall be of powder coated after pre treat ment process. The powder coating shade shall be Genset Green. The base frame shall be painted with epoxy based black shade.
(E) AMF Control Panel : Factory fabricated, Cubical type, free standing, floor mounted, AMF Control Panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0 mm thick CRCA Sheet including two coats of powder coated paint over a coat of red oxide primer etc.and comprising of following:
(i) AMF with relay based control circuit, four pole MCCB 100 Amp 415 V 25 KA. for main supply and DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating Engine start, stop three attempt starting facility and failure to start etc.
(iii) Digital frequency meter
(iv) Digital KWH meter
(v) Digital Power Factor meter (-1.0 to +1.0)
(vi) Current Transformers of suitable CT ratio.
(vii) Indicating lamps for supply 'ON' and load 'ON'
(viii) Instrument fuses ( HRC type)
(ix) Push button 01 No each for start, stop, and re-set
(x) Copper bus bar of capacity 200 Amp for phases and neutral
(xi) Bottom gland plate including glands for incoming and outgoing LT cables
(xii) Circuit diagram plate
(xiii) KWH meter Digital type
(xiv) Instrument fuses HRC type
Notes :- (i) The capacity of Generator set shall be net after all due derating factors as per relevant ISI design. (ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the Panel all as specified and directed. (iii) The quoted rate shall be deemed to be inclusive of first fill of oil and FOL for final successful acceptance test. (iv) The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (v) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of half an hour on 10% overhead in presence of representative detailed by accepting Officer, all arrangements are to be made by the contractor for tests. (vi) All civil works including PCC platform and foundations work required for panel and equipments including making good during installation and commissioning of genset. The depth of the foundation and PCC shall be provided as per recommendations of the manufacturer.
Supply install testing and commissioning Silent type Diesel Engine Generating set 415 volts 62.5 KVA 3 -phase 0.8 power factor 50 Hz, 1500 RPM self exicited self regulated brshless AC generator installed including accoustic enclosure suitable for ambient condition at Pune and confirming to condition under IS 4722, 10001/10002, 13364, BS 5514/2613/5000 with following :-
(A). Alternator :- Standard design alternator rated at 62.5 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000, IS: 13364 and shall be in position to generate supply with frequecy regulation with in + 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722.
i) Insualation class - 'H'
ii) Temparature rise Class - 'H'
iii) Excitation : Self Excited
iv) Regulation performance: The voltage is kept constant with + 1%, manual voltage adjustment within + 5% .
v) Frequency regulation + 1%
(B) Diesel Engine: - Adquate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details water cooled to drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexiable coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS -10001/10002/ 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:-
i) Fly wheel with housing
ii) Cooling system :- Moulded radiator with fan & belts.
iii) Cooling Water pump :
iv) Exhaust System :- Exhaust System complete with exhaust piping upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclousre.
Exhaust gas turbo charger type
Exhaust manifold
Silencer : Residual type
Bellows
iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated/ (as recommended by OEM) for 1% speed /frequecy regulation.
Fuel fileters
Fuel hoses
v) Lub oil System :-
Lubricating oil filter
Lubricating oil pump
vi) Air Intake System :-
Air intake Manifold
Air cleanler dry type
vii) Governer electronic / (as recommended by OEM)
viii) Starting System :- Electric Self starter with and including battary charging alternator.
ix) Battaries :- Battaries of maintenece free of capacity as recommended by the manufacturer complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified and :
Starter gear ring
Start and stop push button
Ignition key / Switch
Handling and operation : Salient features of accessories shall be as under:
Radiator with blower fan
Corrosion inhibitor coolant
Paper element filters for fuel, lub oil and by pass.
Governer electronic (as recommended by OEM) controlled direct fuel injection system
Fly wheel housing and fly wheel.
x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display.
xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine.
xii) Coupling arrngement : - Flexiable coupling, fly wheel to suit flexiable coupling.
xiii) Accessories :- AVM Pads built or separtely mounted to manufactrer base frames as per (as recommended by OEM)
xiv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes.
xv) Fuel Tank :- Daily service fuel tank (as recommended by OEM) with caliberated level indicating arrangement, stop cock, drain plug, complete on a common base in side the accoustic enclosure.
C) Rubber Matting of LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control panel shall be provided.
D) Accoustic Enclosure:- Manufactured by OEM suitable for 62.5 KVA DG Set.
(i) NAL approved as per CPCB
(ii) It shall be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.
(iii) The generating set battaries and control panel shall be inside the enclosure.
(iv) Fuel tank shall be in side the enclosure.
(v) Construction Details/specification are as follows : -
a) Outer body :- CRCA Sheet of 1.6mm thick.
b) Doors :- CRCA sheet of 1.6 mm thick
c) Sound Insulation :- 100 mm thick rock wool (64kg/Cum)
vi) The accoustic shall be composite in construction and fully assembled integral unit.
vii) The battaries shall be placed inside the enclosure beside the DG Set on a suitable inlsulated plat form.
viii) The DG Set shall be provided with external Emergency stop push button.
ix) The enclosure shall be suitably illuminated by CFL/FTL Lamp fittings.
x) The noise level shall be 75 Db at 1m under free field conditions.
xi) The accoustic enclosure parts shall be of powder coated after pre treat ment process. The powder coating shade shall be Genset Green. The base frame shall be painted with epoxy based black shade.
(E) AMF Control Panel : Factory fabricated, Cubical type, free standing, floor mounted, AMF Control Panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0 mm thick CRCA Sheet including two coats of powder coated paint over a coat of red oxide primer etc.and comprising of following:
(i) AMF with relay based control circuit, four pole MCCB 100 Amp 415 V 25 KA. for main supply and DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating Engine start, stop three attempt starting facility and failure to start etc.
(iii) Digital frequency meter
(iv) Digital KWH meter
(v) Digital Power Factor meter (-1.0 to +1.0)
(vi) Current Transformers of suitable CT ratio.
(vii) Indicating lamps for supply 'ON' and load 'ON'
(viii) Instrument fuses ( HRC type)
(ix) Push button 01 No each for start, stop, and re-set
(x) Copper bus bar of capacity 200 Amp for phases and neutral
(xi) Bottom gland plate including glands for incoming and outgoing LT cables
(xii) Circuit diagram plate
(xiii) KWH meter Digital type
(xiv) Instrument fuses HRC type
Notes :- (i) The capacity of Generator set shall be net after all due derating factors as per relevant ISI design. (ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the Panel all as specified and directed. (iii) The quoted rate shall be deemed to be inclusive of first fill of oil and FOL for final successful acceptance test. (iv) The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (v) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of half an hour on 10% overhead in presence of representative detailed by accepting Officer, all arrangements are to be made by the contractor for tests. (vi) All civil works including PCC platform and foundations work required for panel and equipments including making good during installation and commissioning of genset. The depth of the foundation and PCC shall be provided as per recommendations of the manufacturer.
Supply and fix energy saving envorimental friendly, long life, exclusive innovative die cast aluminium IP 65 flood light suitable for 150 watt with and including high power LED of 150 watt as light source and all necessary connections complete all as specified and directed. Make:- Havells/Phillips/Bajaj as approved by GE.
Sewage Disposal
M & L for Construction of RCC Septic tank with Soak pit for 150 users all as specified and all as shown on drawing Nos. CEPZ/2016/DEO/56 sheet No 1/2 and CEPZ/2016/DEO/56 sheet No 2/2.
AIR CONDITIONING
Supply, installation, testing and commissioning of water cooled SCROLL compressor chilling machines 2 Nos Each of 65 TR (minimum) capacity, (2 Nos working) at below mentioned parameters with R-407C refrigerant driven by suitable KW squirrel cage induction motor, Star/Delta Starter with water cooled shell & tube condenser, insulated shell and tube flooded chiller shall be designed for 12 deg C/6 deg C, flow switch at chiller and condenser outlet, suction and discharge refrigerant piping with heat exchanger globe, strainer, expansion valve, solenoid valve and antifreeze thermostat, first charge of refrigerant gas and oil, microprocessor based control panel all mounted on MS frame, vibration isolators and other accessories etc, including necessary foundation. The compressor motor shall be suitable for 400 V +/- 10%, 50 HZ +/- 1% 3 Phase AC supply. The Chiller performance shall be as per ECBC Publication for COP and IPLV. Typical Noise level (Sound Pressure) at 1 Meter distance from the Chiller and 1.5 Meter height 75 decibel. (i) The chiller shall have an ARI certification label at no extra cost. Test certificate from ARI shall include capacity (TR/KW), Power (KW/TR), Pressure drop (ft of water), Integrated Part Load Value (IPLV) shall be submitted. Make :- Blue Star Model No XWC4S-085AR2/Carrier Model No 16LJ11 or techno commercially equivalent model in York/Trane.
(i) All purchase Certificates and Test certificates shall be produced. Proof of Purchase from OEM be provided. No Foreign Exchange or import licence will be provided by Department. Condenser: CDW in 90 Deg F CDW out 99.5 Deg F Fouling factor 0.001(hr-sq-ft-deg F)/Btu Chiller: CDW in 52 Deg F CDW out 43 Deg F Fouling factor 0.0005 (hr-sq-ft-deg F)/Btu (ii) Micro processor type panel board with compressor starter. Chiller shall have been minimum COP 3.00 as per E-in-C policy and IPLV-6.43 (minimum) (The chiller software shall have open protocol (BAC-net/Modbus) to connect with BMS system) (2 W)
Supply, installation, testing and commissioning of mono block horizontal pumping sets for chilled water circulation system. The pump shall be suitable for the given duty points. All parameters shall be as under :- (i) Water Quantity - 180 USGPM (ii) Static Head - 20M (iii) Speed - 1450 RPM (iv) Impeller - Bronze (v) Shaft - Hig Tensile steel (vi) Pump/motor body - CI (vii) Seal - Mechanical (viii) Motor - Suitable HP TEFC (ix) Starter - Star-Delta (x) Base frame - Fabricated MS Note:- One set consist of TWO Pumps.
Supply, installation, testing and commissioning of mono block pump set for condenser, Horizontal directly coupled pump of suitable discharge and head for condenser circulation system. The pumps shall be suitable for the given duty points operation -. All parameters as per Condenser pump shall be as under :- (i) Water Quantity - 300 US GPM (ii) Static Head - 25 M (iii) Speed - 1450 RPM (iv) Impeller - Bronze (v) Shaft - High Tensile steel (vi) Pump/motor body - CI (vii) Seal - Mechanical (viii) Motor - Suitable HP, Squirrel Cage SPDP (ix) Starter - Star-Delta (x) Base frame - Fabricated MS Note (i) Condenser and Primary chilled water pumps flow shall match with chiller requirement. (ii) No price adjustment will be done due to variation in flow of pumps. (III) One set consist of Two Pumps
Supply, installation, testing and commissioning of Induced draft type cooling tower of 160 TR capacity with FRP water basin PVC fills, water distribution arrangement with self rotating sprinklers or fixed nozzles of PVC, statically and dynamically balanced axial flow fan direct driven, TEFC motor with suitable starter, suction screen, make-up and quick fill arrangement, overflow and drain connections, suitable GI inspection ladder, steel supporting structure, ant vibration mounting etc complete as per manufacturer's design/specifications comprising of following :- (i) Water Flow - 320 GPM (ii) Water in - 97.5 Deg F (approx) (iii) Water out - 83 Deg F (approx) (iv) Basin water Temp - 90 Deg F (approx)
Supply, laying, fixing, testing and commissioning of 150 mm dia condenser water un insulated piping with MS ERW class ' C' pipe (Heavy duty (confirming to ISS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, de-scaling valves. The piping shall be laid overhead in plant and underground outside the plant room as per site conditions complete all as specified and directed.
Laying only, fixing, testing and commissioning of 150 mm dia condenser water un insulated piping with MS ERW class ' C' pipe (Heavy duty (confirming to ISS-1239-1958), complete including supply and fix all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, de-scaling valves. The piping shall be laid overhead in plant and underground outside the plant room as per site conditions complete all as specified and directed.
Note for item No 31.7: MS 'C' class pipes 150 mm dia and 90 metre length as brought at site by defaulter contractor shall be issued under Schedue 'B' free for fixing only.
Supply, laying, fixing, testing and commissioning of 100 mm dia condenser water un insulated piping with MS ERW class ' C' pipe (Heavy duty (confirming to ISS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, de-scaling valves. The piping shall be laid overhead in plant and underground outside the plant room as per site conditions complete all as specified and directed.
Laying, fixing, testing and commissioning of 100 mm dia condenser water un insulated piping with MS ERW class ' C' pipe (Heavy duty (confirming to ISS-1239-1958), complete including supply and fix all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, de-scaling valves. The piping shall be laid overhead in plant and underground outside the plant room as per site conditions complete all as specified and directed.
Note ofr item No 32: MS 'C' class pipes 100 mm dia and 60 metre length as brought at site by defaulter contractor shall be issued under Schedue 'B' free for fixing only.
Supply, laying, fixing, testing and commissioning of Pot Strainers 150 mm dia complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Needle Valve 25 mm dia complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Pressure Gauge complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Thermometer complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Allen key Set and Two Manometer complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Butterfly Valve Heavy duty (conforming to ISS-1239-1958 and 3589-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts complete all as specified and directed of following sizes :-
(a) 150 mm dia
(b) 100 mm dia
(c) 50 mm dia
Supply, laying, fixing, testing and commissioning of Balancing Valve 100 mm dia Heavy duty (conforming to ISS-1239-1958 and 3589-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Non Return Valve Heavy duty (conforming to ISS-1239-1958 and 3589-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts complete all as specified and directed of following sizes :-
(a) 150 mm dia
(b) 100 mm dia
Supply installation testing and commissioning low density polyethylene drain pipes size 50 mm dia (LDPE) of pressure rating 4 Kg/cm² on walls/ceiling or laying in floors including fixing with pipe fittings and material as per site requirement complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of 'Y' Strainer with MS class ' C' (Heavy conforming to ISS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, decaling valves of 150 mm dia complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of 2 way pressure Independent Balancing cum control valve along with actuator and step down transformer with temperature sensor with and including 3C x 1.5 sqmm control cable from AHU panel to 02 way valve assembly and controller. (The valve shall close 100% on stopping of AHU) of suitable capacity complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Purge Valve complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Expansion valve 150 mm dia complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation 25mm thick on chilled water piping of the following sizes:-
(a) 150 mm dia
(b) 100 mm dia
Supply installation testing and commissioning nitrile rubber insulation 25mm thick on butterfly valve of the following sizes:-
(a) 150 mm dia
(b) 100 mm dia
Supply installation testing and commissioning nitrile rubber insulation on balancing valve of the following sizes:-
(a) 150 mm dia
(b) 100 mm dia
Supply installation testing and commissioning nitrile rubber insulation on Non Return Valve of the following sizes:-
(a) 150 mm dia
(b) 80 mm dia
Supply, Constructing, Installation, testing and commissioning PVC make-up water tank for cooling tower feed/makeup water 5000 litre capacity. The job includes for make-up water connection from existing pipe line tapping etc. and staging for the tank, head adequate to feed the cooling Tower basin complete all as specified and directed. Note :- Staging required for PVC water tank shall be measured and paid separately under relevant items of this tender.
Supply, laying, fixing, testing and commissioning of closed Expansion Tank 500 litre with and including complete air separator, pressurization units having two pumps, sediment separator, pressure switch, piping, valves, fittings & control panel (at plant room) complete all as specified and directed by the Engineer-in-charge.
Design, Supply, Installation, testing and commissioning Factory made high static double skinned horizontal type Air Handling Unit [AHU] return air washer type 65 TR 19000 CFM with 0.6mm thick pre coated outer skin & 0.6mm thick inner skin made out of GI sheet comprising of backward or forward curved centrifugal blowers of adequate capacity housed in blower section, 3 phase squirrel cage induction motor adequate capacity TEFC type complete with motor pulleys with V-belts. Coil section with cooling coil multi row deep copper tubes with multi row deep with hydraulically bounded sine wave A1 fins tested for17 Kg/Sqcm pressure Filter section complete with cleanable type prefilter metallic type having efficiency 90% down to 10 micron. The make of cooling coils will be as per manufacturer of AHU. The insulation with 25mm thick PUF panels. The AHUs will be floor mounting with anti vibration pads for cooling the air with all accessories and controls comprising the following including painting etc as per standard practice complete all as specified and directed comprising of the following :-
[a] Chilled water cooling coil 8 Row with copper tubes not less than 0.5mm thickness and 13mm over all diameter 10 to 12 aluminium fins per inch.
[b] Micro Vee filters having dust filtration capacity of 5 microns and above down to 95%suitable to requisite static pressure with Belt drive flame proof squirrel cage inductionmotor TEFC, 415V, 3 phase, 50 Hz, AC supply class ‘B’ insulation.
[c] Electrically controlled / operated controls such as humidistat and thermostat along withall equipment and accessories connection to AHU as per design requirement.
[d] Self removable panels with thermal and acoustic insulation.
[e] Sloped bottom to collect humidification and condensate water for draining and drainpiping of sufficient size and length as per standard practice.
[f] Plenum to house micro vee filters and conical section to connect ducting with flexible ducting (canvas).
(g) Acoustic insulation shall be with suitable thickness (not less than 19 mm) elastomeric Nitrile Rubber Open Cell Foam from the mouth of the AHU upto appropriate length as per standard practice.
(h) Control for AHU with blower motor, heating thermostat, humidistat etc., with all accessories shall be deemed to be included as per manufacturer’s specifications.
Supply and erection of GSS ducting for supply and return air duct complete with flanges, nut, bolts, washers of GI angle iron supports and MS rods complete comprising the following:-
(a) 24 Gauge
(b) 22 Gauge
Fixing only and erection of GSS ducting for supply and return air duct including supply and fix flanges, nut, bolts, washers and GI angle iron supports and MS rods complete comprising the following:-
(a) 24 Gauge
(b) 22 Gauge
NOTE FOR ITEM 36.7 & 36.8: G I sheets as brought at site in sheet form 100 numbers of each guage of size 1.22 m x 2.44 m brought at site by the defaulter contractor will be issued free for fixing only.
Supply, laying, fixing, testing and commissioning of Supply Air Diffuser With Volume Control Damper of size 300mm x 300 mm complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Return Air Diffuser With Volume Control Damper of size 600mm x 250 mm complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of following sizes :-
(a) 1500mm x 700 mm
(b) 1350mm x 600 mm
(c) 1200mm x 500 mm
(d) 900mm x 450 mm
(e) 600mm x 300 mm
(f) 400mm x 200 mm
(g) 300mm x 200 mm
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of following sizes :-
(a) 1500mm x 800 mm
(b) 1500mm x 650 mm
(c) 1200mm x 600 mm
(d) 1000mm x 500 mm
(e) 600mm x 250 mm
Supply, laying, fixing, testing and commissioning of Fire Dampers with Fusible link of following sizes :-
(a) 1500mm x 700 mm
(b) 1500mm x 800 mm
Supply, construct, install, testing and commissioning of Fresh Air Louvers with G.I opposed blade Damper, Bird screen & Cowl complete all as specified and directed.
Supply install testing and commissioning of pan humidifier 50 KW (for AHU) for winter season with and including connecting pipe, all accessories, valves etc. from tank with necessary heaters and connection wiring complete with humidistat complete all as specified and directed.
Supply, Install, Testing and Commissioning of thermostats, humidistat and Air stat for monsoon/winter condition (1 SET each bank) complete all as specified and directed.
Supply, install, comissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS/CRCA 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc., complete with fittings and accessories complete all as specified and directed so as to produce 1 -1.5 m/sec air velocity at floor level for following door opening sizes :-
Supply, Installation, Testing and Commissioning of Thermal Insulation for Inside Supply air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick 3" wide aluminium foil faced self adesive tape at all joints complete as per the specifications and approved drawings.
Fixing only and Installation, Testing and Commissioning of Thermal Insulation for Inside Supply air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick 3" wide aluminium foil faced self adesive tape at all joints complete as per the specifications and approved drawings. NOTE : Nitrile insulation sheet 19mm thick class 'O' Alu foil shall be issued under Sch 'B' free for fixing only.
Supply, Installation, Testing and Commissioning of ACCOUSTIC Insulation for air ducting with 13 mm thick OPEN cell elastrometric Nitrile rubber and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade complete all as specified and directed.
Fixing only and Installation, Testing and Commissioning of ACCOUSTIC Insulation for air ducting with 13 mm thick OPEN cell elastrometric Nitrile rubber and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade complete all as specified and directed. NOTE : Accosound Nitrile insulation sheet 15mm thick class I shall be issued under Sch 'B' free for fixing only.
Supply, Installation, Testing and Commissioning of Thermal Insulation for Inside return air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick 3" wide aluminium foil faced self adesive tape at all joints complete as per the specifications and approved drawings.
Fixing only and Installation, Testing and Commissioning of Thermal Insulation for Inside return air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick 3" wide aluminium foil faced self adesive tape at all joints complete as per the specifications and approved drawings. NOTE : Nitrile insulation sheet 19mm thick class 'O' Alu foil shall be issued under Sch 'B' free for fixing only.
Supply & fixing of INSULATION FOR UNDER GROUND & EXPOSED PIPING & EXPOSED DUCT with 32 mm thick Nitrile rubber complete all as specified and directed.
Fixing only and & fixing of INSULATION FOR UNDER GROUND & EXPOSED PIPING & EXPOSED DUCT with 32 mm thick Nitrile rubber complete all as specified and directed. NOTE : Nitrile insulation sheet 32mm thick class 'O' shall be issued under Sch 'B' free for fixing only.
Supply & fixing of Under deck insulation with 25 mm nitrile rubber with 40-60 KG density complete all as specified and directed.
Fixing only & fixing of Under deck insulation with 25 mm nitrile rubber with 40-60 KG density complete all as specified and directed. NOTE : Nitrile insulation sheet 25mm thick Eco class I shall be issued under Sch 'B' free for fixing only.
S & F M.S Pedestal stand with canopy for suspending Fire buckets duly painted with 2 coats of synthetic enamel P.O red over a coat of red oxide primer complete all as specified and directed by the Engineer in charge.
S & F Galvanized MS fire bucket 14 litrs capacity for fire stand complete all as directed by the Engineer-in-charge.
S & F Portable fire extinguisher CO2 type 10 kg capacity complete all as directed by the Engineer-in-charge.
S & F following items for fire stand complete all as directed by the Engineer-in-charge :- (a) Fire beater - 01 No. (b) Fire hook – 01 No. (c) Fire bell it hammer – 01 No.
M&L for Lockable Push button for cooling tower complete all as specified and directed.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor mounting, dust and vermin proof cubical type, CPRI approved, LT panel fabricated from 2.0 mm thick CRCA sheet, Indoor type duly compartmentalized for each switch gear, front and rear open-able (front hinged opening), locking arrangement with chromium plated 19 mm dia locks (min 2 Nos in each compartment), lifting lugs of suitable size on top, louvers and air vent gasket for natural air, `U` shape rubber gasket, voltmeter, ammeter, APFC Relay, Frequency meter. Panel shall be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade suitable for 900 amps with suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance , high strength FRP/SMC/DMC material at an interval not more than 500 mm throughout the length of bus bars, including suitable aluminum earth strips
conforming to IS with danger notice plate, necessary cable glands, cable connection with proper copper/ aluminum lugs. The cubical incomer MCCB as well as outgoing shall have copper TPN extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link of min 500 mm long supported on suitable size `F` class insulator to be provided for termination on incomer and outgoing cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel shall be mounted on bottom channel of suitable size with proper mounting arrangement as directed by Engr-in-Charge leaving min 500 mm all around the panel board for movements all as specified with supply and fixing the following:-
Supply, installation, testing and commissioning of LT, automatic power factor correction (APFC) panel, factory made, weather, dust & vermin proof, made out of 3.15 mm thick CRCA steel sheet duly powder coated with metalised poly propylene (MPP) type capacitors bank, heavy duty of 85 KVAR with variable correction shall comprise of 02 Nos stepping (2x25KVAR, 2x10KVAR, 3x5 KVAR). The panel shall have copper bus bar of suitable size, 3 phase and with neutral and with the following:- (a) MCCB, TP, 160 Amps (adjustable type), 25 KA – 01No (incoming) (b) Heavy duty Contactors suitable frequent operation having current limiting resistors suitable for capacitive switching of variable KVAR correction of superior specifications. (c) MCCB/MCBs 'C' curve for back up protection of capacity as required. (d) Microprocessor based intelligent APFC relay for controlling variable connection KVAR (e) Indication lamp RYB (LED type) with toggle switch – 03 Set.
(f) MPP type heavy duty capacitor bank consisting of suitable No of switching sequences, 3 phase, 415 volts suitable for 10% over voltage & 30% over current having loses less than 0.5 W /KVAR with discharge resistors. (g) Suitable Nos & rating of contractors as required. (h) Internal wiring of panel with stranded copper cable of suitable size. (i) The design of panel shall be got approved from GE before fabrication.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor/wall mounting, dust and vermin proof cubical type, CPRI tested, LT panel fabricated from 2.00 mm thick CRCA steel sheet , duly compartmentalized for each switch gear, front and rear open-able (front hinged opening) ,locking arrangement with chromium plated 19 mm dia fancy locks (min 2 Nos in each compartment), lifting lugs of suitable size on top, louvers and air vent gasket for natural air, `U` shape rubber gasket. Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade for 500 amps with suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance , high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of bus bars including suitable aluminum earth strips, with danger notice plate, necessary cable glands, cable connection with proper aluminum/copper lugs.
(iv) Three indication lamps 22.5 mm dia LED type for three phases with back up protection by 2 Amps MCB.- 2 Set. (B) Out goings :- (i) MCB 100 Amps, TP, 415 V AC, 50 Hz, breaking capacity 25 KA , Thermal magnetic release with thermal release range 100-160Amp )- 01 Nos. (For Blower) (ii) MCB 25 Amps, TP, 415 V AC, 50 Hz, ultimate breaking capacity 10 KA , 03 Nos (For Pan humidifier, building lighting,spare) (iii) MCCB 200 Amps, 4 Pole, 415 V AC, 50 Hz, breaking capacity 25 KA , Thermal magnetic release with thermal release range ) - 01 Nos. (For Heater) (iv) Internal wiring of panel should be done with single core multi stranded copper conductor cable not less than 2.5 Sqmm / PVC Insulated Copper Stip of suitable size.
Note :- (i) Drawing of LT panel and make of items to be got approved from Eng-in-Charge before ordering the panel. (ii) Cost of lugs for cables and cable gland etc also included in unit rate of panel.
NOTES APPLICABLE TO ALL ITEMS OF AIR CONDITIONING :- (A) All bidders shall check the requirements of Air conditioning items, heat load calculations etc as per details given. In case any deficiency/discrepancy is noticed between requirements as per their calculation and as provided for in Schedule ‘A’/BOQ, the same shall be intimated by the bidder on or before the clarification end date given. In case no intimation received by the Accepting officer i.e CE Pune Zone, the bidder has to provide any other items (not covered in Schedule ‘A’/BOQ, but required as per site requirement as decided by the Accepting Officer) to meet the desired parameters (i.e. Inside temperature :- 22 oC + 2 oC and Humidity :- 55% + 5%) of air conditioning plant, any enhancement of capacity of AC equipment specified in Schedule ‘A’/BOQ and to maintain the desired inside conditions shall deemed to be included in the unit rates quoted for the relevant items and nothing extra shall be paid by the department on this account.
(B) Civil works such as cutting and making good of openings in walls / ceiling / floor for passage of duct, pipes, cables etc., provision of foundations / pedestals for chiller units, pump sets, cooling tower make up water tank, chilled water tanks, LT Panels etc. is deemed included in the unit rate quoted by Contractor for above items. Wall brackets, angles, clamps etc. as required for pipes, ducts and cables etc. is also included in scope of above works. No extra payment shall be made on this account. (C) All civil work including PCC blocks/plinth for installing AHU, Foundations for Chillers, Pumps etc. opening in walls for duct, pipes and cables has to be done by authorise rep of AC manufacturer and closing and finishing shall also be done by the authorise rep of AC manufacturer. No extra payment shall be made on this account.
(D) Provision of Inlet and outlet pipe connection for Make up water tank, Cooling Tower and Expansion Tank is deemed included in the unit rate quoted by Contractor for above items. No extra payment shall be made on this account. (E) Phase I test for 24 hours will be carried out after completion and after successful completion of Test, Certificate to be produced. Phase II Test for 72 Hours will be carried out in Summer, Monsoon and Winter. After completion of Three tests final Completion Certificate will be issued. (F) The complete Unit shall be guaranteed by the contractor for 12 Months from the date of issue of Provisional completion certificate.
Cooling Appliances
Supply, install, testing and commissioning of self contained drinking water cooler partially stainless steel working with non CFC refrigerent of above 3 star rating suitable for operation on 230 Volts 50 cycles AC supply having approx storage and nominal cooling capacity 60 Litres & 120 Litres respectively including connecting the items complete with and including making of PCC platfarm of suitable size as directed for fixing of water cooler complete all as specified and directed by the Engineer-in-charge.
Supply, install, testing and commissioning of voltage stablizer for automatic operation, suitable for 60 litres capacity water cooler, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with output voltage stablized at 230 volts with accuracy of + 2.5% and capacity 3 KVA complete all as specified and directed.
Lightening protection
Supply and fix weather proof galavanised iron box made out of 1.6 mm thick galvanised iron sheet for test point fixed on wall complete all as specified and directed.
Fire fighting
S & F CI foot valve conforming to IS 4038 of size 100 mm bore with and including necessary fixing material complete all as specified and directed.
S & F fire extinguisher ABC type 5kg squeeze grip type with ISI mark charged with dry chemical powder mono ammonium phosphate based charged at pressure 15kg/sqcm with brass forged/gun metal valve as per IS 13489 along with wall mounted bracket complete all as specified and directed.
S & F fire extinguisher ABC type 10kg squeeze grip type with ISI mark charged with dry chemical powder mono ammonium phosphate based charged at pressure 15kg/sqcm with brass forged/gun metal valve as per IS 13489 along with wall mounted bracket complete all as specified and directed.
S & F MOBILE TYPE Fire extinguisher ABC type 25kg squeeze grip type with ISI mark charged with dry chemical powder mono ammonium phosphate based charged at pressure 15kg/sq cm with brass forged/ gun metal valve as per IS 13489 along with wall mounted bracket bracket complete all as specified and directed.
S & F yard hydrant post/stand post 80mm dia GI both ends flanged height of 1.5m including hydrant valve single headed conforming to IS 908 complete all as specified and directed.
Supply and laying PVC insulated PVC sheathed multistranded copper conductor cable FRLS of size 2 core 1.5 sqmm complete all as specified and directed.
Furniture
S & F push back chair available in ctc 22" complete all as specified below and as directed by the Engineer-in-charge :- Make of Push Back Chair :- Penworkers model No PW009MBRP any other equivalent model in Krishna Quinette as approved by GE. (a) Seat rest assembly :- The seat rest assembly shall be made of 1.5 cm thick marine plywood in situ moulded with polyurethane foam & upholstered with fabric. [Seat size 530 mm (W) x 600 mm (D) x 950 mm (H)]. (b) Back Rest Assembly :- Back rest assembly shall be made up of a MS fabricated frame in situ moulded with polyurethane foam. The back foam is designed with contoured lumbar support for extra comfort. [Back size 46.5 cm (W) x 62.5 cm (D) x 9.5 cm (T) Avg]. (c) Polyurethane Foam :- The polyurethane foam for seat and back shall be moulded with density = 45+/-2Kgs/cum and hardness = 20+/-2 on hempden machine at 25% compression 5 of 31. (d) Armrest :- The armrest shall be made up of integral polyurethane foam and reinforced with M.S inserts. The armrest to be provided with Cup holder.
(e) Sliding Mechanisam :- The sliding mechanism shall be fabricated from M.S sheets forming linkages providing a synchronous motion for seat & back. The sliding stroke for the seat shall be 100 mm. The mechanism houses the seat & back. (f) Side Panel/Aisle Panel :- The chair rests on the ground on two side panel frames made of 2.5 mm thick CR steel. Each side panel shall be fitted with two upholstered partical board 9 mm thick. The side panel frame shall be grouted in the floor using foundation expansion bolts through base plate. (g) Powder Coating :- All steel components shall be epoxy polyster powder coated.
Stage lighting
S & F for stage light of PAR 64, 1000 Watt, 240 volts, shielded beam with 01 Mtr, 3 core copper conductor cable, 15 Amp plug top & clamp complete all as specified and directed by Engr-in-charge. Make : New Stage Craft or tecno commercially equivalent make as approved by GE.
S & F for Spot light 1000 watt with T-11 type lamp and 01 mtr, 3 core copper cable, 15 Amp plug top & clamp complete all as specified and directed by Engr-in-charge. Make :- New Stage Craft or tecno commercially equivalent make as approved by GE.
S & F for Fresnels light 1000 watt, 240 volts, Halogen lamp 150 mm dia, Fresnel lens, barn door , suitable length of 03 core copper cable, 15 Amp plug top & clamp complete all as specified and directed by Engr-in-charge. Make :- New Stage Craft or tecno commercially equivalent make as approved by GE.
S & F for Profile light 1000 watt, 240 volts with 01 Mtr of 03 core copper cable, 15 Amp plug top & clamp complete all as specified and directed by Engr-in-charge. Make :- New Stage Craft or tecno commercially equivalent make as approved by GE.
S & F for Halogen flood light, Barm door type 1000 watt, halogen tube , 240 volts with 01 M of 03 core copper cable, 15 Amp plug top & clamp complete all as specified and directed by Engr-in-charge. Make :- New Stage Craft or tecno commercially equivalent make as approved by GE.
S & F MS Pipe Ladders size 600mmX2400 mm on the sides of the stage to be fixed from the existing top structural grid made of 50 mm X 25 mm MS pipe complete all as specified and directed by Engr-in-charge.
Note for Stage lighting :- Controls & requisite Point wiring is deemed to be included in the quoted rates of items and no additional cost shall be payable by the Govt on this account.
Audio system
Supply, install, Testing & Commissioning of Main FOH : Full Range Loudspeaker with 1 x 15" woofer driver, 2 x 4.5" cone driver; Frequency Response : 50Hz -16kHz (for Passive) & 50Hz -300Hz/300Hz- 16kHz (for Biamplified LF/MF-HF); Nominal Impedance : 8Ω; Nominal Dispersion : 90˚H x 40˚V; Power handling capacity : 500W (for Passive) & 300W (for biamplified LF) & 100W (for biamplified HF); Max SPL : 122dB; Sensitivity : 95dB; Installation : Indoor. (#1 Left; #1 Cente; #1 Right) with and including mounting/hanging arrangement complete all as specified and directed by Engr-in-charge. Make :- Audio/RCF/Bose/JBL
Supply, install, Testing & Commissioning of Surround Speaker : Small format sound reinforcement loudspeakers with 2 x 8" Driver ; Frequency Response : 80 Hz - 16 kHz; Nominal Dispersion : 90°H x 60°V; Power handling capacity : 300 W; Sensitivity : 94 dB; Max SPL : 119dB; Nominal Impedance : 8 Ω; 18-gauge (1.2 mm) perforated steel; Powder-coated finish grille with Two-part spray polyurethane coating Enclosure. (4 Nos Left Surround, 4 Nos Right Surround) with and including mounting/hanging arrangement complete all as specified and directed by Engr-in-charge. Make :- Bose Model No Room match utility RMU 208 or any other equivalent model in Audio/RCF/JBL as approved by GE.
Supply, install, Testing & Commissioning of Subwoofer : Bass / Subwoofer with Frequency Response : 40Hz -280Hz; Nominal Impedance : 4Ω; Nominal Dispersion : Omni-directional; Power handling capacity : 800W; Max SPL : 123dB;; Sensitivity : 94dB with and including mounting/hanging arrangement for indoor installation complete all as specified and directed by Engr-in-charge. Make :- Bose Model No LTMB24 or techno commercially equivalent model in Audio/RCF/JBL as approved by GE.
Supply, install, Testing & Commissioning of Stage Monitor : Multi-position Floor Monitor with 3 x 2.25" mid-high frequency driver combined with 1 x 5.25" woofer; Frequency Response : 70Hz-16kHz; Nominal Dispersion : 60˚H x 120˚V; Power handling capacity : 100W; Powder-coated steel grille; Nominal Impedance : 8Ω; Max SPL : 111dB; Sensitivity : 91dB with and including mounting/hanging arrangement for indoor installation complete all as specified and directed by Engr-in-charge. Make :- Bose/Audio/RCF/JBL.
Supply, install, Testing & Commissioning of Amplifier : Configurable professional power amplifier with 8 input channels; 2-8 output channels (configurable); Frequency response : 20Hz-20kHz; Max rated power : 4000W; Total harmonic distortion (THD) : < 0.4%; Mono mode output power : 300W @ 8Ω, 500W @ 2Ω and 4Ω; V-bridged mode output power : 1000W; Quad mode output power : 2000W; Signal to noise ratio : > 102 dBA with and including mounting/hanging arrangement complete all as specified and directed by Engr-in-charge. Make :- Bose/Audio/RCF/JBL.
Supply, install, Testing & Commissioning of Digital Signal Processor: A-weighted 32-bit fixed/floating-point DSP + ARM; Frequency Response : 20 Hz – 20 kHz; 456 MHz Signal processor; Dynamic Range : > 115 dB 8 analog (balanced, mic/line level), 16 digital (via option card) input channel; Output channel : 8 analog (balanced, line level), 8 ESPLink, 16 digital (via optional card); Sample Rate : 48 KHz; THD : 0.002%; Ethernet (RJ-45); 100Mb network control with and including mounting/hanging arrangement complete all as specified and directed by Engr-in-charge. Make :- Bose/Audio/RCF/JBL.
Supply, install, Testing & Commissioning of AV Receiver : HDMI version 1.4a (3D,ARC); 6-HDMI inputs and 1 output; 2 assignable component video inputs and 1 output; Direct play for portable audio devices, USB memory device via USB; XLR analog input; XLR 7.1ch Pre output; Tone control; Streams audio / pictures over the Network (PC, NAS) via DLNA 1.5; Supports WMA, MP3, WAV, MPEG-4 AAC, FLAC, JPEG files; Bright VFD display with English and Spanish display Front-panel key lock feature; HP output; RS-232c serial / IP controllable; IR controllable with included IR remote control with and including mounting/hanging arrangement complete all as specified and directed by Engr-in-charge. Make :- Denon Model No DN 500AV or techno commercially equivalent model in other make as approved by GE.
Supply, install, Testing & Commissioning of Mixer : 24 channel mixing console (with Effect) with and including mounting/hanging arrangement complete all as specified and directed by Engr-in-charge. Make :- Allen & Health Model No ZED2842 or techno commercially equivalent model in other make as approved by GE.
Supply, install, Testing & Commissioning of Blue-ray 3D player with and including mounting/hanging arrangement complete all as specified and directed by Engr-in-charge. Make :- Pioneer/Denon.
Supply, install, Testing & Commissioning of Head worn microphone complete all as specified and directed by Engr-in-charge. Make :- Shure/Bose.
Supply, install, Testing & Commissioning of Hand held wireless microphone complete all as specified and directed by Engr-in-charge. Make :- Shure/Bose.
Supply, install, Testing & Commissioning of Dynamic wired microphone, transducer type: dynamic, Polar pattern: cardoid, frequency response 50Hz to 15 kHz, sensitivity 1.88 mV/Pa complete all as specified and directed by Engr-in-charge. Make :- Shure Model No SM58 or techno commercially equivalent model in Bose as approved by GE.
Supply, install, Testing & Commissioning of Dynamic wired microphone for instruments, transducer type: dynamic,Polar pattern: cardoid, frequency response 40Hz to 15 kHz, sensitivity 1.88 mV/Pa complete all as specified and directed by Engr-in-charge. Make :- Shure Model No SM57 or techno commercially equivalent model in Bose as approved by GE.
Supply, install, Testing & Commissioning of Podium microphone transducer type Condensor,Polar pattern Super cardioid, frequency response 50 Hz to 17 kHz, sensitivity 23.7mV/Pa 18" length complete all as specified and directed by Engr-in-charge. Make :- Shure Model No MX418DC or techno commercially equivalent model in Bose as approved by GE.
Supply & install Microphone stand (big) complete all as specified and as approved by GE.
Supply & install Microphone stand (small) complete all as specified and as approved by GE.
Supply & install Juntion Box : 4 point Junction boxes complete all as specified and directed by Engr-in-charge. Make :- Custom or any other equivalent make as approved by GE.
S & F Speaker Cable : 2 core 2.5 sq mm PVC insulated Copper conduction loudspeaker cable complete all as specified and directed by Engr-in-charge. Make :- Klotz Model No LY225 or techno commercially equivalent model in other makes as approved by GE.
S & F Microphone Cable: 2 core PVC insulated Copper conduction sheilded microphone cable complete all as specified and directed by Engr-in-charge. Make :- Klotz Model No MY 206 or techno commercially equivalent model in other makes as approved by GE.
S & F Connectors : XLRConnectors .&Speakon complete all as specified and directed by Engr-in-charge. Make :- Nutrik or any other equivalent make as approved by GE.
S & F Equipment Rack for housing all rack mountable equipments with internal wiring, front glass door; heat dessipation fans; movement wheels, power distribution units etc complete all as specified and directed by Engr-in-charge. Make :- Custom Model No 42U or techno commercially equivalent model in other makes as approved by GE.
S & F PVC conduit with necessary accessories heavy duty, ISI marked, concealed in walls etc., for laying of CCTV, PA system and sound system cables complete all as specified and directed by Engr-in-charge of following sizes :-
(a) 40 mm dia
(b) 32 mm dia
(c) 32 mm dia
Supply and fix two way Bib taps, CP, fancy type with crutch or butterfly handle, screwed down, high pressure for iron pipe or for brass ferrule of size 15 mm bore complete all as specified and directed.
PRIME COST SUM: Provide Prime cost Sum of Rs 455000.00 for Supply, install, testing and commissioning of frame fabricated projection screen 14'x27' size complete all as directed by the Engineer-in-charge. Note :- 1. This prime cost is pre priced by MES and the Add/deduct pe+B317rcentage(%) will be shown in column 56 (Fifty six) of this BOQ over the sum inserted by MES and contractor has to quote their lumpsum rate in column 13 in such away that the percentage worked out shall not exceed 15% (Fifteen percent), in case the percentage worked out exceeds 15% (fifteen percent), the amount inserted shall be amended to ensure that the percentage worked shall not exceed 15%. Please also refer condition 5 of IAFW-2249 General Conditions of Contract. 2. Contractor has to quote his rate only in column 13 and the percentage for Prime cost sum will be calculated automatically in column 56 (Fifty six).
PROVISIONAL SUM : Provide Provisional SUM for "DEVIATION ORDERS PARTIALLY EXECUTED AND BALANCE WORKS OR NOT EXECUTED" as per Appendix-III.
PHASE-II Outsourcing services for Manning, Operation & maintenance of Air conditioning plant during defect liability period including all connected equipments and accessories in 01 (One) shift of 08 Hours in a day after completion of Phase-I test of plants including Saturday, Sunday & holidays complete all as specified & as directed by the Engineer-in-charge.
Outsourcing services for Manning, Operation & maintenance of Air conditioning plant after completion of defect liability period including all connected equipments and accessories in 01 (One) shift of 08 Hours in a day including Saturday, Sunday & holidays complete all as specified & as directed by the Engineer-in-charge.
Notes For Manning & Operation (Phase-II) :- (a) The Work order for M&O shall be placed for eleven months & no price adjustment for its extension will be permissible. (b) The AC System will be operated for 08 hours in 01 shift per day unless otherwise specified by the Engr-in-charge/GE. Necessary recovery will be made for non operation of plants shift wise on prorata basis of quoted rates of above item. Recovery rate shall be double the rate quoted by the bidder for each shift & shall be final & binding. (c) The Shift shall be manned by the following staff:- (i) The Operator being deployed in the work shall have minimum qualification of ITI (REFERIGERATION & AC) alternatively ITI (Mechanical) holder with 02 (Two) years of experiance in relevant field. Necessary technical qualification certificate shall be produced for verification of Engr-in-charge & get the approval before deploying for works-01 No. (d) Proper & efficient functioning of the plant must be ensure through regular inspection by qualified engineer bi-monthly. (e) After the defect liability period the plant will be maintained by the contractor by carrying out routine maintainanace as per the procedure mentioned in the PS.
(f) Any repairs/replacement of parts will be carried out by the contractor by engaging his labour. However the material/spares required will be supplied by the department free of cost after defect liability period. During defects liability period all the materials/spares required will be supplied by the contractor. The unit rate quoted by the contractor shall deemed to include these aspects. No claim whatsoever shall be entertained by the Deptt at later stage.
GANESH ELECTRICALS AND AIR CONDITIONERS
M/s KARUNAYAK NAYAK
United Sales Corporation
K R TRADERS
Horizon Construction
Vishal Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .