Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹29.0 L+₹7.1 L (32.3%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹31.1 L+₹9.2 L (42.0%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | P. M. COOLING AND ENGINEERING CO L2 | GITANJALI ELECTRONICS AND ELECTRICALS L3 | Shinryo Suvidha Engineers India Pvt. Ltd. L1 |
|---|---|---|---|---|---|---|
| 1.00 | S&D of minimum 7KW nominal cooling capacity ceiling suspended [ concealed] Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Scroll Compressor / Swing compressor in inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories (Make :O General model ARG25FUAN/AOG25FNANL/ Similar of Mitsubishi Electric / Mitsubishi heavy industries). | 2 | Nos | 1,27,673.8 ₹2,55,347.6 | 1,36,993 ₹2,73,986 | 99,486.61 ₹1,98,973.22 Lowest |
| 2.00 | S&D of minimum 13KW nominal cooling capacity ceiling suspended [ concealed] Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Scroll Compressor / Swing compressor in inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories (Make : DAIKIN model FDMF140BRV16/ RZMF140BRY16 / Mitsubishi heavy industries model FDUM125CSV-S6/FDC125CSV-S6 / O General model ARG60F/AOG60F). | 2 | Nos | 2,54,772 ₹5,09,544 | 2,73,369 ₹5,46,738 | 1,91,772.21 ₹3,83,544.42 Lowest |
| 3.00 | Installation testing & commissioning of above AC machines by fixing the indoor with adequate MS angle supports sized 50mmX5mm with 10mm X75mm anchor fastner bolt drilled into the ceiling and grouted into the wall . The indoor unit suspended from this support with 4 nos 10mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed after making suitable MS structure platform with 50x5mm MS angle support grouted into the wall with cross arm support. Grill support at top and both sides to be made with suitable size angles and MS flats and locking arrangement. A shet at top the outdoor unit also to be made with corrugated GI sheet to avoid damage from top. The job to be done considering all civil works and mending good the damages of walls by CC & sand cement plaster . All MS works need to be finished with primer and paints and executed as per the direction of EIC. | 4 | Sets | 25,117 ₹1,00,468 | 26,951 ₹1,07,804 | 19,039.6 ₹76,158.4 Lowest |
| 5.00REFRIGERANT PIPING: Supplying, laying and commissioning of hard copper refrigerant piping (minimum thickness 0.9 mm), complete with fittings, elbows, supporting arrangements etc.with Nitrile Rubber tube insulation of 9 mm thick on Copper Pipe. (Make- K-Flex/Armacell) | ||||||
| 5.01 | Discharge Line 6mm dia, min. thickness 0.8mm (Make : Rajco / Royku/Nippon). | 25 | Mtrs. | 564 ₹14,100 | 605 ₹15,125 | 424 ₹10,600 Lowest |
| 5.02 | Discharge Line 9.5mm dia, min. thickness 0.8mm (Make : Rajco / Royku/Nippon). | 15 | Mtrs. | 854 ₹12,810 | 917 ₹13,755 | 643 ₹9,645 Lowest |
| 5.03 | Suction Line 15.88mm dia, min. thickness 0.99mm (Make : Rajco / Royku/Nippon). | 25 | Mtrs. | 1,701 ₹42,525 | 1,825 ₹45,625 | 1,280 ₹32,000 Lowest |
| 5.04 | Suction Line 19.05mm dia, min. thickness 0.99mm (Make : Rajco / Royku/Nippon). | 15 | Mtrs. | 2,066 ₹30,990 | 2,217 ₹33,255 | 1,555 ₹23,325 Lowest |
| 6.00 | CONDENSATE DRAIN PIPING: Supplying & laying of 25 mm dia (SCHEDULE 40) Drain Water piping work out of PVC / HDPE hared pipes, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors with insulation. (Make - Supreme/Finolex/Prince Pipe) | 40 | Mtrs. | 548 ₹21,920 | 588 ₹23,520 | 413 ₹16,520 Lowest |
| 7.00 | CONTROL CABLING: Supply & Laying of 6 Core 2.5 sq.mm.unarmoured Cu control cable. 1.1 KV Gr. PVC/XLPE insulated, PVC- Sheathed cable, Copper armoured for Control cable incl.laying on wall surface by suitable clamping arrangement, proper glanding & finishing the cable ends with solderless sockets for following cables. (Make - Polycab/Havells/Finolex ) | 80 | Sq.M. | 592.34 ₹47,387.2 | 636 ₹50,880 | 446 ₹35,680 Lowest |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
10 Aug 2026, 12:00 pmClosed
Exe.Engr._I, KSHED, P.W.Dte.
75 D H Road Kidderpore Kol_23
Urgent renovation work of E.I., Airconditioning system, FDA systems at DSA cathlab at BIN old building, BIN, annex I, IPGME and R SSKMH.(Electrical Work)-Renovation of Air-Conditioning System at DSA Cathlab
2026_WBPWD_5016027_1
WBPWD/EE-I/KSHED/Q20/26-27
Open Tender
A/C ORG
Item Rate
45 days
SSKM Hospital
Please refer Tender documents.
5 documents required · 5 mandatory
₹42,000
O/o EE, KSHED, P.W.Dte.
17 Aug 2026
25 Jun 2026
12 Aug 2026
25 Jun 2026
10 Aug 2026
3 Jul 2026
2 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&D of minimum 7KW nominal cooling capacity ceiling suspended [ concealed] Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Scroll Compressor / Swing compressor in inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories (Make :O General model ARG25FUAN/AOG25FNANL/ Similar of Mitsubishi Electric / Mitsubishi heavy industries). | 2 | Nos | - | - |
| 2 | S&D of minimum 13KW nominal cooling capacity ceiling suspended [ concealed] Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Scroll Compressor / Swing compressor in inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories (Make : DAIKIN model FDMF140BRV16/ RZMF140BRY16 / Mitsubishi heavy industries model FDUM125CSV-S6/FDC125CSV-S6 / O General model ARG60F/AOG60F). | 2 | Nos | - | - |
| 3 | Installation testing & commissioning of above AC machines by fixing the indoor with adequate MS angle supports sized 50mmX5mm with 10mm X75mm anchor fastner bolt drilled into the ceiling and grouted into the wall . The indoor unit suspended from this support with 4 nos 10mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed after making suitable MS structure platform with 50x5mm MS angle support grouted into the wall with cross arm support. Grill support at top and both sides to be made with suitable size angles and MS flats and locking arrangement. A shet at top the outdoor unit also to be made with corrugated GI sheet to avoid damage from top. The job to be done considering all civil works and mending good the damages of walls by CC & sand cement plaster . All MS works need to be finished with primer and paints and executed as per the direction of EIC. | 4 | Sets | - | - |
| 5REFRIGERANT PIPING: Supplying, laying and commissioning of hard copper refrigerant piping (minimum thickness 0.9 mm), complete with fittings, elbows, supporting arrangements etc.with Nitrile Rubber tube insulation of 9 mm thick on Copper Pipe. (Make- K-Flex/Armacell) | |||||
| 5.01 | Discharge Line 6mm dia, min. thickness 0.8mm (Make : Rajco / Royku/Nippon). | 25 | Mtrs. | - | - |
| 5.02 | Discharge Line 9.5mm dia, min. thickness 0.8mm (Make : Rajco / Royku/Nippon). | 15 | Mtrs. | - | - |
| 5.03 | Suction Line 15.88mm dia, min. thickness 0.99mm (Make : Rajco / Royku/Nippon). | 25 | Mtrs. | - | - |
| 5.04 | Suction Line 19.05mm dia, min. thickness 0.99mm (Make : Rajco / Royku/Nippon). | 15 | Mtrs. | - | - |
| 6 | CONDENSATE DRAIN PIPING: Supplying & laying of 25 mm dia (SCHEDULE 40) Drain Water piping work out of PVC / HDPE hared pipes, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors with insulation. (Make - Supreme/Finolex/Prince Pipe) | 40 | Mtrs. | - | - |
| 7 | CONTROL CABLING: Supply & Laying of 6 Core 2.5 sq.mm.unarmoured Cu control cable. 1.1 KV Gr. PVC/XLPE insulated, PVC- Sheathed cable, Copper armoured for Control cable incl.laying on wall surface by suitable clamping arrangement, proper glanding & finishing the cable ends with solderless sockets for following cables. (Make - Polycab/Havells/Finolex ) | 80 | Sq.M. | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.21 MB
TenderForm.pdf
Tender Documents • 0.69 MB
BOQ_5085183.xls
BOQ • 0.70 MB
corrigendum_2.pdf
PDF • 0.44 MB
corrigendum_1.pdf
PDF • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .