| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | L1 | Accepted-AOC Being the lowest bidder and fulfilling all the criteria | |
| 2 | L2₹36.8 L+₹2.4 L (6.96%)Rejected-Finance 4 1 70 1 ROAD NO 11 SNEHAPURI NACHARAM HYDERABAD 500 076 | HYDERABAD | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | L2 | Rejected-Finance Not being the lowest bidder | |
| 3 | L3₹37.7 L+₹3.3 L (9.65%)Rejected-Finance NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L3 | Rejected-Finance Not being the lowest bidder |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
18 Mar 2020, 6:00 pmClosed
GARRISON ENGINEER, GE CHENNAI
GARRISON ENGINEER, FORT ST GEORGE CHENNAI
SPECIAL REPAIR TO BUILDING NO. T-15 AT SOL AND PROVISION OF FALSE CEILING AT BAR AND ANTE ROOM OF DB AREA JCO S MESS UNDER GE CHENNAI
2020_MES_327076_1
8404/E8
Open Tender
Civil Works
Item Rate
180 days
GE Chennai
As per tender document
7 documents required · 7 mandatory
₹500
GE Chennai
₹61,000
Yes
24 Apr 2020
20 Feb 2020
24 Mar 2020
20 Feb 2020
18 Mar 2020
3 Mar 2020
Amount
B/R ITEMS
Supply only integral liquid water proofing compound conforming to IS 2645 - 2003 all as specified and directed.
M&L for reinforced cement concrete, M-30 (Design mix), using 20mm and below graded stone aggregate as in roof slabs supported on walls, beams and columns in floors, roofs, deck slabs and the like all as specified and directed.
M&L for reinforced cement concrete, M-30 (Design mix), using 20mm and below graded stone aggregate as in roof beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed.
M&L for precast RCC (1:1½:3) type A-1 using 20mm graded aggregate as in manhole covers, landings, chullah hoods, chajjas with plain faces set in cement mortar (1:4) complete all as specified and directed.
M&L cleaning of reifforcement bars of ant dia in any RCC member by scraping and removing the rust completely by using suitable rust removing liquid (Shali Prime RC of STP Ltd or equivalent) and applying epoxy based anti corrosive paint (Shali Prime Zn R of STP Ltd or equivalent) as per manufacturer's instructions including 10mm thick rendering over concrete surface in cement mortar (1:3) mixed with epoxy based bonding agent (Shali Mortar M of STP Ltd or equivalent) in the proportion recommended by the manufacturer as directed. Notes: (i) The work is to be executed upto a height of 10.00m from the groung level anq the quoted rate shall be deemed to include for this aspect. (ii) THe quoted rate shall be deemed to include for element of special scaffolding required for executing this item.
M&L for demolition of highly deteriorated portion of RCC beams, pillars, chajjas and lintels etc. at height upto 3.00m and applying based bonding agent Shali SRB latex of STP Ltd or equivalent on concrete surface as per manufacturer's recommendations, casting RCC member cement concrete (1:1½:3) using 12.5mm graded stone aggregate mixed with plasticiser admixture powder STP No. 1 of STP Ltd or equivalent @ 1 kg per 50 kg of cement or in proportion recommended by the manufacturer including necessary formwork complete all as specified and directed. Notes: (i) Grouting of cracks, cleaning of existing reinforcement with rust remover, application of anti corrosive paint and replacement of reinforcement wherever necessary before recasting RCC shall be measured and paid for separately. However, cost factor towards special scaffolding required for carrying out these items of work at various heights shall be deemed to be included in the quoted rates.
All as per item No. 6 but height exceeding 3.01m but n. exc. 6.00m.
All as per item No. 6 but height exceeding 6.01m but n. exc. 10.00m.
M&L for brick work straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6) using old size sub class 'B' bricks complete all as specified and as directed.
M&L for brickwork with old size sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, including supports, overhangs, etc. also splays between floors and beams complete of flat rough finished surfaces of concrete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick of flat rough finished surfaces of concrete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc. 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but not exc. 20cm wide flat rough finished surfaces of concrete all as specified and directed.
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area not exc. 1.5 sqm each along with fittings including separating guard bars/ grills/ wire mesh etc., complete all as specified and as directed.
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area exc. 1.5 sqm not exc 4sqm each along with fittings including separating guard bars/ grills/ wire mesh etc., complete all as specified and as directed.
Taking down shutters of any description exc. 1 sqm but n. exc. 2 sqm each including all fittings complete all as specified and as directed.
Taking down shutters of any description n. exc. 1sqm each and resecuring in the same opening after cutting, easening etc. with new iron mongry complete as specified and directed.
M&L for second class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm MS square tube of 19 gauge mitred out at two corners and joined by inserting two Nos of 150mm long brackets of 15mm x 15mm MS square tube inside the drilling 100mm long MS screws using PVC fastener complete all as specified and as directed.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles) with 2, 4, 6 raised panel design with 2mm thick moulded PVC sheet on front face and 2mm thick plain colour colour PVC sheet on back face fixed to frame at site complete all as specified and directed.
S&F second class hardwood glazed and skeleton door shutters, 30mm thick divided into squares, open rebated and prepared to receive glass, gauge etc., with sash bars, edges of framing plain, chamfered, rounded fitted with cut and mitred beads for securing glass etc, size of members as specified in SSR Part 1 section 8 clause 8.20 (a) supplied and fitted to chowkats complete all as specified and as directed.
S&F second class hard wood, plain framed, 35mm thick panelled shutters (any number of panels) with rails and panel of 12mm thick veneered particle board with commercial veneering on both faces, the size of rail and stile are as per IS 1003 (part I) Kiln seasoned and chemically pressure treated and fitted to chowkats complete all as specified and as directed.
S&F stainless steel butt hinges, medium weight cold rolled 100mm size ISI marked all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section 200mm long all as specified and directed.
S&F aluminium handles, fabricated type anodised 150mm size all as specified and directed.
S&F aluminium alloy anodised sliding door bolts 300mm long with hasp, staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections all as specified and as directed.
S&F mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F hasp and staple 100mm size, aluminium anodised safety type with mild steel hinge pin including bolt to hinge plate fixed with screws complete all as specified and directed.
S&F decorative type Harrison rails 20mm dia mild steel CP with designer brackets ( one pair in each opening) stop,s rollers etc. fixed in repairs complete all as specified and directed.
S&F continuous piano hinges mild steel bright finish or elactro-galvanized width of flap (when open) 30mm complete all as specified and directed.
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.4mm fixed with aluminium wire staples fixed to wooden frames/Aluminium shutters complete all as specified.
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.4mm fixed with aluminium wire staples fixed to wooden frames fixed in repairs complete all as specified.
S&F anodized aluminium powder coated (minimum thickness of powder coating 50 micron) windows and ventilator shutters, side hung type with sash bars, aluminium section weighing not less than 0.55 Kg/ RM including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws, anodised aluminium fittings such as peg stay 150mm long (01 No.), 100mm long hinges type B-21 (02 No.), handle 01 No in each shutter complete all as specified and directed.
S&F anodized powder coated aluminium (minimum thickness of powder coating 50 micron) frames for doors, windows and ventilator with one or more rebates including joining cleats for fixing complete all as specified and directed.
S&F aluminium anodised powder coated (minimum thickness of poder coating 50 micron) window security grills with frame 6mm thick 75 mm aperture fixed with joining cleats etc. complete all as specified and as directed.
M&L for mild steel work in bands, straps, supports of stays, sunshade brackets, hook and pintle hinges, clamps, hold fasts, guard bars, grills bolts etc and similar conforming to FE-290, Gde E 165 complete all as specified and directed.
M&L for 10mm dia and over mild steel TMT bars as in reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and directed.
M&L for 6mm to 8mm dia mild steel TMT bars cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and directed.
M&L framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw including bending and welding angles, as necessary, gusset plate, riveting etc. n. exc. 10kg each brackets conforming to FE-290, Gde E 165, complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for APP modified prefabricated polymeric membrane, 3mm thick of weight not less than 3.6Kg/Sqm reinforced with non woven polyester matt, black finished on cold sticker and torch application of membrane with 10cm over lap after necessary preparation of roof surface over 10mm thick screed in cement mortar (1:4) when concrete is green with WPC as per manufacturer's instructions including water proofing treatment consisting of the following all as specified :- (i) One coat of bitumen primer @ 0.40 Kg/Sqm. (ii) One coat of bonding material of blown type bitumen of grade 85/25 heated with working temperature of 180 degree Cent and applied @ 1.20 Kg per square meter of the surface area. (iii) A layer of APP modified polymeric membrane of specified thikness and wight. (iv) Top most layer of surface finished with one coat of heat resisting aluminium paint. (v) Rate of WPC shall be inclusive in the quoted rate and nothing extra will be paid.
M&L for cleaning the surface of sunken floor with wire brush and washing with hydrochloric acid to remove dust, dirt, oil, grease, loose particles etc., and applying a coat of water based acrylic polymer modified MIXGUARD AC @ 1 Kg per sqm as in Part A (Powder) and Part B (Liquid) in ration (3:1) and rendering 20mm thick in cement mortar (1:4) as in sunken floor slab, sunken portion of walls mixed with water proofing compound as per manufacturer's instructions and finished even and smooth including provision of 50mm dia PVC pipe as spot complete all as specified and directed.
S&F pre-laminated particle board 18/ 19mm thick, exterior grade pre-laminated on one side with decorative choice lamination and other side balancing white lamination fixed with screws as in cupboard shutters and shelves etc. fixed in repairs including 5mmx18/19mm Ist class hardwood beading all round complete all as specified and directed.
M&L for galvanised powder coated snap grid framework for false ceiling all as specified including Vinyl laminated MPL gypsum panels (GYPTECH) 9mm thick of size of 60cm x 60cm fixing with staples on snap grid on RCC slabs by means of GI wire not less than 4mm dia, hooks and rawl plugs etc at 1200mm c/c of make GYPTECH/ ARMSTRONG OR equivalent complete all as specified and directed.
Demolition of floor hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises to out side MD land etc., complete all as specified and as directed.
Roughening of old concrete surface by picking, sweeping cleaning and washing down with water to remove dust etc. and brushing neat cement slurry @ 3kg/ sqm complete all as specified and as directed.
M&L 75mm thick PCC (1:3:6) type C-2 using 40mm stone graded aggregate as in plinth protection including filling of joints by bitumen and sand in ratio 1:2 complete all as specified and directed.
M&L for machine pressed cement concrete tiles of size 20cm x 20cm x 20mm thick with grey cement and set and jointed in neat cement slurry in floors and pointed over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
S&F coloured glazed designer ceramic tiles as in vertical surfaces of size 300mm x 200mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick rendering in cement mortar (1:4) complete all as specified and as directed.
M&L 25mm thick cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in sub floor finished fair and even complete all as specified and directed.
M&L Non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exceeding 0.11 Sqm but not exc. 0.18 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
All as per Item No 52 above but as in skirtings, risres etc., over 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
M&L for Non skid coloured ceramic tiles 7mm to 8mm thick (Square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L machine cut Kota stone slab 20-25mm thick as in flooring laid over and including 15mm thick screed bed in cement mortar (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L machine cut Kota stone slab 20-25mm thick as in riser of steps, skirting, dado & pillars etc. laid over and including 15mm thick backing coat in cement mortar (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
Taking down cement plaster on brick work or stone walls etc. including racking out of joint, hacking for key, scrubbing down with water etc. and removing the debris outside MD land complete all as specified and as directed.
M&L rendering 15mm thick in two coats i.e. 1st coat 10mm thick in cement mortar (1:6) and 5mm thick finishing coat in cement mortar (1:4) mixed with and including PIDI PROOF LW compound @ 200ml per bag and finishing the surface even and smooth without using extra cement complete all as specified and directed. Note: Supply only of water proofing compound shall be measured and paid for separately under appropriate item of this BOQ.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and the like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite stone including cutting & polishing laid over and including 15mm thick screed in cement mortar (1:4) including making hole for gas pipe and dismantling the old stone complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for 5mm thick rendering in cement mortar (1:3) as on ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar (1:3) as on ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior acrylic emulsion paint (Apex of Asian or Weather coat of Berger or equivalent of other specified makes) over a coat of exterior sealant and white primer complete all as specified and as directed.
M&L for complete removal of existing treatment with electric operated blade, washing with water and bleaching powder solution on external surface of walls and applying two coats of Weather Proof Exterior Acrylic Emulsion paint (Apex of Asian or equivalent of other specified makes) over a coat of sealant and exterior primer complete all as specified and as directed.
M&L for applying two coats of white wash on ceilings including preparation of old treated surfaces complete all as specified and directed.
M&L for applying three coats of white wash on ceilings including preparation of newly plastered surfaces complete all as specified and directed.
M&L for complete removal of existing treatment on wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
S&F sheet glass 4.0mm thick, ordinary quality and fixed to aluminium windows in square not exc. 0.5 sqm in each pane complete all as specified and as directed.
S&F sheet glass 4.0mm thick, pin head type and fixed to aluminium windows in square not exc. 0.5 sqm in each pane complete all as specified and as directed.
M&L for preparation of new wooden or wood based surface of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old treated wooden or wood based surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F galvanised steel water tubing 15mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc fixed to walls, concealed in walls/ ceilings or laid in floors etc, including taking up or down the existing GI tubing complete all as specified and directed. Note : Rate quoted shall be inclusive of cutting, chasing and making good in cement mortar.
S&F galvanised steel water tubing 20mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc fixed to walls, concealed in walls/ ceilings or laid in floors etc, including taking up or down the existing GI tubing complete all as specified and directed. Note : Rate quoted shall be inclusive of cutting, chasing and making good in cement mortar.
S&F galvanised steel water tubing 25mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc fixed to walls, concealed in walls/ ceilings or laid in floors etc, including taking up or down the existing GI tubing complete all as specified and directed.
Taking up or down the existing GI water tubing 15mm bore medium grade and re-fixing in same or other location using new fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. complete all as specified and directed.
Taking up or down the existing GI water tubing 20mm bore medium grade and re-fixing in same or other location using new fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. complete all as specified and directed.
Taking up or down the existing GI water tubing 25mm bore medium grade and re-fixing in same or other location using new fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. complete all as specified and directed.
S&F 500 litre capacity three layered rotational moulded polyethelene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including dismantling existing OHT complete all as specified and directed.
S&F ball valve PTMT with epoxy coated aluminium rod for 20mm bore pipe, weight not less than 210gms, high pressure with polyethylene high density float and complete screwed for iron pipe fixed in repairs complete all as specified and directed.
S&F 15mm dia bib taps cast copper alloy, fancy type chromium plated with crutch or butterfly handle screwed down, screwed for iron pipes or for brass ferrule and fixed in repairs complete all as specified and directed.
S&F 15mm dia fancy type pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipes fixed in repairs complete all as specified and directed.
S&F 15mm dia angular brass stop valves chromium plated screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed in repairs complete all as specified and directed.
S&F 15mm PVC connection 450mm long with brass nuts fixed in repairs complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125mm, 190mm long shower arm fixed to steel pipe or union complete all as specified and directed.
S&F in repairs vitreous china wash down water closet squatting pan Orissa pattern of size 580 x 440mm with integral foot rest (white or light coloured) including making necessary connection to soil pipes and flushing cistern complete all as specified and directed.
S&F PVC low level flushing cistern 10 ltr with complete accessories such as PVC flush pipe, over flow pipe etc. fixed in repairs complete all as specified and directed.
S&F vitreous china wash basin white flat back size 550 x 400mm including cutting for and pinning in the ends of bracket or erecting stand but excluding tap, waste chain, plug and porcelain stopper but including brackets and 32mm dia PVC waste coupling with waste pipe fixed in repairs complete all as specified and directed.
S&F in repair 600mm x 450mm bevelled edged looking mirror 6mm thick with aluminium frame work fitted with 6mm thick commercial ply or AC sheet backing to mirror complete all as specified and directed.
S&F in repairs glass shelf matt finished chromium plated (MCH/ colour CP) with bracket end fittings as per Cat No. T6009A1 of Parryware or equivalent from other makes specified in particular specifications all as specified and directed.
S&F in repairs stainless steel 1mm thick kitchen or laboratory sink with draining board with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of size 40 x40 x6mm MS angle iron and connecting union to pipe overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F 20mm dia tubular towel rail 'D' type 60cm long brass chromium plated fixed in repairs complete all as specified and directed.
S&F PTMT shelf with and including chromium plated brass screws and wooden/ plastic cleats (minimum weight 300 g) fixed in repairs complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/floors etc. including demolition and breaking up existing pipe complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/floors etc. including demolition and breaking up existing pipe complete all as specified and directed.
S&F 110mm dia PVC (SWR) bend any radius all as specified and directed.
S&F 75mm dia PVC (SWR) bend any radius all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) branch piece, single ‘Y’ equal or unequal with access door complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) branch piece, single ‘Y’ equal or unequal with access door complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs PVC (SWR) floor trap, plain with grating including joining with solvent cement 110mm dia of outlet complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron works new or old treating ends of posts, back of chowkats etc with tar or coal tar black paint area tarred exc. 0.1 sqm but n. exc. 0.5sqm each complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron works new or old treating small articles such as hold fast etc with tar or coal tar black paint area tarred n.exc 0.1sqm each complete all as specified and directed.
Demolition of brick masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facings, dressed stone work including removal of rubbish outside MD land complete all as specified and as directed.
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick below or above GL including removal of debris to outside MD land complete all as specified and as directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, stair landings, chajjas and similar suspended works complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any situation not otherwise specifically provided for complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, kitchen shelfs etc. (laid, bedded and pointed in any mortar) complete all as directed and specified.
Dismantling wall/ ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets; any thickness, including cover fillets/ snap grid etc. complete all as specified and directed.
E/M ITEMS
M&L for point wiring complete with 2.5sqmm (nominal area) PVC insulated unsheathed multistranded, (for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including 20mm bore non metallic rigid PVC conduit medium grade, ISI marked, with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc. including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 2.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified for one socket outlet (plug point) three pin 15 Amps controlled by one switch 15 Amps on independent board including taking down existing point wiring complete all as specified and directed.
M&L for point wiring for one light point controlled by one switch complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including 20mm bore metallic rigid PVC conduit medium grade, ISI marked, with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc. including new pressed steel terminal boxes 1.6mm thick concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly including taking down existing point wiring complete all as specified and directed.
All as per item No. 112 but for one fan point controlled by one switch through regulator.
All as per item No. 112 but for one 3 pin socket outlet on independent board.
All as per item No. 112 but for one 3 pin socket outlet on the same board with other switches.
All as per item No. 112 but for one light point controlled by two number two way switches.
All as per item No. 112 but for bell point controlled by bell push.
M&L for point wiring complete with 4.0sqmm (nominal area) PVC insulated unsheathed multistranded, (for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including 20mm bore non metallic rigid PVC conduit medium grade, ISI marked, with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc. including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 4.0sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified for AC and geyser point on independent board including taking down existing point wiring complete all as specified and directed.
S&F switch socket combination, 2 in 1, 15 Amps, 230 volts flush type all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5 Amps, 230 volts.
S&F switch piano, flush type, single pole, two way, 5 Amps, 230 volts.
S&F call bell of multi music type, single pole, AC, 230 volts all as specified and directed.
S&F switch socket combination, 2 in 1, 5 Amps, 230 volts flush type all as specified and directed.
S&F ceiling rose PVC/ polycarbonate body 65 x 50mm; 2 to 3 terminals 230 Volts, AC Single phase all as specified and directed.
S&F stepped flush type electronic ceiling fan regulator 300 watt all as specified and directed.
Supply and fix 20 Watts LED light fitting, basic all purpose surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver including 20W LED tube all as per Cat No. LUMILINEBS20WLED865SPCWH of Havells or equivalent of other specified makes including taking down old fitting complete all as specified and directed.
Supply and fix 10 Watts LED light fitting, basic all purpose surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver including 10W LED tube all as per Cat No. LUMILINEBS10WLED865SPCWH of Havells or equivalent of other specified makes including taking down the old fitting complete all as specified and directed.
Supply and fix Wall mounted LED batten 10 Watts LED 6000K (600mm) in extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver including 10Watts LED tube light all as per Cat No.ENDURALINEARNEO BS10WLED 865SPCWH of Havells or equivalent of other specified makes fixed on surfaces of waall or ceiling including taking down the old fitting complete all as specified and directed.
M&L for submain wiring complete with two runs of 4.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including rigid non metallic PVC conduit medium grade ISI marked 25mm external dia fixed on wall/ floor/ ceiling along with conduit fittings and accessories, fixed on ceiling with one run of 4.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit any type complete all as specified. Note: Two runs of 4.0sqmm multistranded cable and one run of 4.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for submain wiring complete with two runs of 6.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including rigid non metallic PVC conduit medium grade ISI marked 25mm external dia fixed on wall/ floor/ ceiling along with conduit fittings and accessories, fixed on ceiling with one run of 6.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit any type complete all as specified. Note: Two runs of 6.0sqmm multistranded cable and one run of 6.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 42, TPN, 6 way, 415 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 8623 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc., complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 42, SPN, 8 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 8623 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing isolator four pole, 63 Amps, 415 volts including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB single pole (MCB SP), 6 to 32Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 32 Amps, 230 Volts including taking down old one complete all as specified and directed.
M&L bracket fabricated out of 40mm dia GI light grade pipe 2 metre long bent to shape as directed and fixing to pole with brackets of suitable size complete all as specified and directed.
S&F LED street light luminaire outdoor type 20 Watts new generation energy saving and environment friendly long life versatile pressure die cast aluminium IP66 roadway luminaire with high power LEDs as high light source and electronic driver suitable for operation on AC single phase 220-240 volts, 50 Hz supply, including provision of two single core 4 sqmm copper conductor PVC insulated, 1100 volts cable not less than 8 metre long and making connection from junction box of pole including taking down old fitting complete all as specified and directed. Make: Havells Cat Part No. INDURAPEARLLEOSL20WLED 787SASYTOPC 9405 or equivalent of other specified make.
Excavation in trenches in soft/ loose soil not exceeding 1.5m in wide and not exceeding 1.5m in depth and getting out for laying cable all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing excavated material/ soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply, laying, connecting up and testing XLPE insulated armoured LT UG electric cable with aluminium conductor 1100 V grade of size 6 sqmm 2 core laid in trenches, fixed along wall or passing through pipes/ in floors including taking out old worn out cable complete all as specified and directed.
Supply, laying, connecting up and testing XLPE insulated armoured LT UG electric cable with aluminium conductor 1100 V grade of size 16 sqmm 4 core laid in trenches, fixed along wall or passing through pipes/ in floors including taking out old worn out cable complete all as specified and directed.
Supply and laying river/ M-sand as in cushioning for underground electric cable all as specified and as directed. (Punned thickness shall be only measured and paid).
Supply and laying well burnt sub class 'B' bricks old size in trenches for protection of underground cable all as specified and directed.
M&L cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15mm bore light grade connected upto switch board including 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No. 3 of MES Schedule Part I including dearth chamber of PCC (1:2:4) type B-1 using 20mm grade aggregate with 40mm thick RCC cover slab (1:1½:3) type A-0 using 12.5mm graded stone aggregate reinforced with 8mm dia TMT bars @ 100mm c/c both ways and 6mm dia MS lifting hooks including testing on completion complete all as specified and as directed.
Supply and fix 42 Watts environment friendly, new generation, aesthetically, ultra modern designed recess mounting luminaire with high brightness SMD LEDs as light source suitable for 2' x 2'grid ceiling all as per Cat No. PLUTONEO2x2PLR34WLED840S of Havells or equivalent of other specified makes fixed to ceiling including taking down the old fitting complete all as specified and directed.
Taking down carefully, dismantling and opening ceiling fan/ exhaust fan of any size/ any make after disconnecting the electric connection for attending repairs, reassembling, refixing and re-connecting the fans to ceiling rose/connector after necessary servicing and replacing the spare parts etc., complete all as specified and as directed. Note: (i) Supply only of spares and painting will be measured separately. (ii) Servicing like cleaning, application of lubricant oil/ grease, replacement of pins, nuts, bolts etc is deemed to be included in the quoted rates.
Supply only condenser 2.5 Mfd capacity for any make/ sweep/ type of fans, conforming to relevant IS specification and as directed.
Supply only condenser 4 Mfd capacity for any make/ sweep/ type of fans, conforming to relevant IS specification and as directed.
Supply only ball bearing of size 6201 suitable for any make/ sweep/ type of fans, conforming to relevant IS specification. Make: SKF/ TATA/ NBC
Supply only ball bearing of size 6202 suitable for any make/ sweep/ type of fans, conforming to relevant IS specification. Make: SKF/ TATA/ NBC
Supply only gun metal bush for any make/ sweep / type of fans.
Supply only canopy plastic with fixing arrangement, top and bottom for ceiling fan of any make/ sweep as specified and directed.
Supply only rubber bush real type suitable for 1200/ 1400/ 1500mm sweep ceilings fans of any make as specified and directed.
M&L for applying one coat of synthetic enamel paint with gun spray for any sweep/ make of ceiling/ wall mounting fans including filling the cavities with filler after cleaning, scraping all dust/ rust on fans/ down rods/ blades etc., and numbering the fans "MES NO" with black enamel paint complete all as specified and directed.
Taking down existing energy meter for carrying out repairs to building, keeping in safe custody and refixing in the same location/ quarter after repairs have been carried out complete all as specified and as directed.
SIRITEL SYSTEMS PRIVATE LIMITED
G.L.THIRUMALAI NAIDU AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .