Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹22.3 L+₹2.4 L (12.0%)Rejected-Finance 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | L2 | Rejected-Finance Being L2 |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
21 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Priyanka Tak GE I AF Shillong
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
REPAIR AND MAINTENANCE OF CENTRAL HEATING SYSTEM
2023_MES_619758_2
8041/23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE I AF SHILLONG
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE I AF SHILLONG
₹39,000
Yes
28 Nov 2023
2 Nov 2023
23 Nov 2023
2 Nov 2023
21 Nov 2023
2 Nov 2023
Amount
Material and labour for complete overhauling and servicing of AIR HANDLING UNITS of following capacities at various locations and to carry out following activities:- (a) Thorough/detailed examinaton of AHU including ducts in plant room and connected accessories and preparing list of defects and spares/components to be replaced. (b) Thorough cleaning of AHU including ducts in plant room by compressed air system / vacuum cleaner. (c) Thorough cleaning of AHU including ducts in plant room by using mild detergents and water spraying and drying the complete system. (d) Preparing old steel surfaces including motor, filter frames, grills, external and internal body of AHU, duct of AHU in plant room and spray painting in two coats using synthetic enamel paint of approved colour. (e) Replacing unserviceable spares/components. (e) Oiling/Greasing/Lubricating of various parts for smooth functioning. Notes : (a) Cost of labour for replacement of new spares/component shall be deemed to be included in quoted rates. (b) New spare parts/components shall be measured and paid as Supply only under respective items of BOQ here-in-after. (c) Cost of cosumables like Oil/Grease/Lubricants shall be deemed to be included in quoted rates.
Capacity 54 KW
Capacity 72 KW
Capacity 84 KW
Capacity 110 KW
Material and labour for dismantling shaft of AHU plant, transporting to workshop, re-metalling, grinding, machining on lathe and other machines to bring the same in size to fit with bearing for proper functioning, transporting back to AHU plant and re-installing/ commissioning the shaft & pulley with proper alignment complete all as specified and directed.
Material and labour for disconnection of electric connection, dismantling the Blower Motor 3 to 15 HP from the base/pulley/shaft, thorough/detailed examinaton of motors and preparing list of defects and spares/components to be replaced, replacing unserviceable spares/components, complete servicing/overhauling and re-assembling of motor, oiling/greasing/lubricating of various parts for smooth functioning, checking for proper alignment, re-installing the same, making necessary terminal connections with proper copper lugs & proper alignment of pulley and testing and commissioning complete all as specified and directed for following capacities blower motors:- Notes : (a) Cost of labour for replacement of new spares/component shall deemed to be included in quoted rates. (b) New spare parts/components shall be measured and paid as Supply only under respective items of BOQ here-in-after. (c) Cost of cosumables like Oil/Grease/Lubricants shall be deemed to be included in quoted rates. (d) Rewinding of motor if required shall be measured and paid under respective items of BOQ here-in-after.
Blower motor of capacities 3 to 5 HP
Blower motor of capacities 15 HP
Material and labour for rewinding of Blower motor (induction type) with super ennameled copper winding wire of existing size and turns, insulator paper fixing, coil fitting, varnishing, baking, including cleaning of grooves of stator, replacement of terminal box (6 terminals), connection etc, testing and commissioning complete all as specified and directed for following capacity motors :- Notes : (a) Dimantling and re-installation of motors shall not be included in quoted rates against this item (b) Cost of re-winding and other scope as described in item shall be deemed to be included in quoted rates against this item.
Blower motor of capacities 3 to 5 HP
Blower motor of capacities 15 HP
Supply only following parts :-
Heat proof porcelain insulator with suitable size nuts/bolts & washers
V-belt of type B-84 to B-95
Ball bearing of size 6205/6308or nearest size as existing in motor.
Ball bearing of size 6410/6310or nearest size as existing in motor.
Cooling fan suitable for 3 to 5 HP motor as per existing model.
Cooling fan suitable for 15 HP motor as per existing model.
Taking out old unserviceable strip heater fins type and Supply & Fix strip heater fins type for working on 230 Volts, AC, 50 Hz supply of approximate size 0.85m x 0.9 m fixed with suitable nuts, bolts etc complete all as directed for 3 KW capacities
Supply and fix as in replacement pedestal type ball bearing of type 6000 ( UC-207-20 ) or suitable for shaft complete
Material and labour for cleaning the fresh/suction air filter (60X50cm) first by vaccum cleaner, then by compressed air and subsequently by mild detergent based solution complete all as specified and directed
Supply and fixing in replacement fresh/suction air filter (60X50cm) of large airflow and of huge dust holding capacity with low initial pressure drop and cleanable/washable type fixed with Air handling unit all as per sample at site, complete all as specified and directed.
Supply and fixing in replacement of two groove cast iron/Mild Steel V belt shaft pulley of 20 cm radius/existing size suitable for mounting two belts complete all as specified and as directed.
Taking out old unserviceable Mild Steel air grills and supply, erection, testing & commissioning of powder coated adjustable type Mild Steel air grills of Size (40 x 25 x 11 cm outer flange) with nuts, bolts & screws complete all as specified and as directed.
Supply and fix in replacement sheet metal enclosure single door DB SPN 2 way, 240 volts, protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 all as specified and directed. Make: L&T/ Siemens/ Schneider/ Hagger/ Legrand/ ABB/ Havells
Supply and fix in replacement MCB SPN 63 Amps, 240 volts, C-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I, complete, all as specified & directed. Make: L&T/ Siemens/ Schneider/ Hagger/ Legrand/ ABB/ Havells
Taking out old unserviceable PVC insulated & PVC Round Sheathed 3 core 10 Sqmm cable from any situation and Supply and fix/lay PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 complete all as specified and directed. Make: Havells/ Nicco/ KEI/ Finolex/ Polycab
Taking out old unserviceable PVC insulated & PVC unsheathed lead glass coated single core 10 Sqmm cable from any situation and Suuply and fix/lay PVC insulated & PVC unsheathed lead glass coated thermal stable single core 10 Sqmm multi stranded copper conductor cable 1100 Volt grade complete all as specified and directed. Make: Havells/ Nicco/ KEI/ Finolex/ Polycab
Supply and fix in replacement copper lugs suitable for 10 Sqmm size cable complete all as specified and directed
Supply and fix in replacement busbar chamber 4 pole factory made using CRCA sheet steel of 1.6mm thick and epoxy powder coated and ETP grade copper and dull tin plated busbar sections including dough moulding compound (DMC) busbar support of protection class IP-31, standard conformity IEC-60439/IS-8623 of 315/320 A current carrying cap, 440 volts, 50Hz, short circuit withstand capacity 35 KA in 01 Sec including 8 Nos of outgoing complete all as directed.
Supply and fix in replacement busbar chamber 4 pole factory made using CRCA sheet steel of 1.6mm thick and epoxy powder coated and ETP grade copper and dull tin plated busbar sections including dough moulding compound (DMC) busbar support of protection class IP-31, standard conformity IEC-60439/IS-8623 of 100A-125 A current carrying cap, 440 volts, 50Hz, short circuit withstand capacity 35 KA in 01 Sec including 8 Nos of outgoing complete all as directed.
Supply and fix in replacement synthetic insulation mat for electric purpose of size 2m x1m x 3mm thick as per IS:15652 complete all as specified and directed.
Supply only following components/parts in existing LT Panels/LT feeder pillar boxes:-
Analog type Voltmeter 0-500 volts, 3 Phase of size 96mm x 96mm. Make: L&T/ Siemens/ Schneider/ Hagger/ Legrand/ ABB/ Havells
Ammeter 0-400 Amps capacity, 3 Phase, class I accuracy, 0.5 VA burden including set of CTs of size 96mm x 96mm. Make: L&T/ Siemens/ Schneider/ Hagger/ Legrand/ ABB/ Havells
LED type Indicating lamp flush mounted, Red, yellow or blue colour as directed. Make: L&T/ Siemens/ Schneider/ Hagger/ Legrand/ ABB/ Havells
Toggle switch
Start push button (green) complete with internal connection suitable for running of 5-10 HP motor
Stop push button (Red) complete with internal connection suitable for running of 5-10 HP motor
Over load protection relay suitable for 3 phase 415 volt for induction motor for 50-70 Amp load Make: L&T/ Siemens/ Schneider/ ABB/ Havells
Electronic Star Delta Timer suitable for 240 - 415 VAC,1 NO (Star) + 1 NO (Delta), with settable start time, settable pause time, indication for Star & Delta, for 3 phase 415 volt motor, 50-70 Amp load capacity Make: L&T/ Siemens/ Schneider/ Hagger/ Legrand/ ABB/ Havells
Rotary handle Extended Rom type for d Sine MCCB 3 phase, 440 Volts Make: L&T/ Siemens/ Schneider/ Hagger/ Legrand/ ABB/ Havells
Power contactor 3 pole 70A Make: L&T/ Siemens/ Schneider/ Hagger/ Legrand/ ABB/ Havells
Repair/maint of Split type Air Conditioners including disconnecting electrical connections, storing refrigerant gas in compressor of outdoor unit, splitting indoor and outdoor units, checking for faults and worn out parts/components, removing all accumulated dust and dirt of indoor and outdoor units, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassembling indoor and outdoor units, re-installing both indoor and outdoor units at respective locations (old or new locations as directed), re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required or connecting with service valves in outdoor unit and in indoor unit with threaded cast copper alloy sockets , making electrical connections, testing and commissioning complete all as directed for the following capacity Air Conditioners :- Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, thermal insulation, felts, lead metal balancing of blower fans, lugs, thimbles, sockets and other minor materials shall be deemed to be inclusive in quoted rate. (b) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against these items
(b) Split type Airconditioner 1.5 TR capacity of any make
(c) Split type Airconditioner 2.0 TR capacity of any make {Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, thermal insulation, felts, lead metal balancing of blower fans, lugs, thimbles, sockets and other minor materials shall be deemed to be inclusive in quoted rate. (b) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against these items}
Repair/maint of Deep freezers including disconnecting electrical connections, checking for faults and worn out parts/components, removing all accumulated dust and dirt, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassemblingdeep freezer, re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required or connecting with service valves with threaded cast copper alloy sockets , making electrical connections, testing and commissioning complete all as directed for the following capacity Deep Freezers :-
(a) Deep Frezer of 200 Litre capacity of any make
(b) Deep Frezer of 400 Litre capacity of any make
(c) Deep Frezer of 500 Litre capacity of any make
Repair/maint of refrigerators including disconnecting electrical connections, checking for faults and worn out parts/components, removing all accumulated dust and dirt, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassembling refrigerators, re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required, making electrical connections, testing and commissioning complete all as directed for the following capacity Refrigerators :- Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, lugs, thimbles other minor materials shall be deemed to be inclusive in quoted rate. (b) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against this item
(a) Refrigerators of 165 Litre to 255 Litre capacity of any make
Supply only following spare parts/components of ACs, Deep freezers, Refrigerators, Package type AC Units, refrigerant Gas for all these equipments/appliances complete all as directed :- Notes : (a) Genuine spare parts/components and refrigerant gas as originally fitted/filled in ACs, Deep freezers, Refrigerators, Package type AC Units shall only be provided during repairs/replacement. (b) These genuine spare parts/components and refrigerant gas shall be procured through OEM/their authorised distributers or dealers/service frenchise/service stations (Authosised to deal in genuine spare parts/components)
Control circuit (PCB) for 1.5 TR capacity Split/Tower type AC, operating on 50 Hz electric supply of current rating, humidity control rating, operating temperature range and impedence as per Technical parameter of existing PCB installed by OEM in AC.
Control circuit (PCB) for 2.0 TR capacity Split/Tower type AC, operating on 50 Hz electric supply of current rating, humidity control rating, operating temperature range and impedence as per Technical parameter of existing PCB installed by OEM in AC.
Remote circuit unit with remote controller cord, nylon fastner, tapping screw for 1.5 TR capacity Split/Tower AC as per Technical parameter of existing Remote circuit unit installed by OEM in AC.
Remote circuit unit with remote controller cord, nylon fastner, tapping screw for 2.0 TR capacity Split/Tower AC as per Technical parameter of existing Remote circuit unit installed by OEM in AC.
Copper tube of size 3/8 inch outer dia, 0.8mm thick ISI marked for Air conditioners.
Copper tube of size 5/8 inch outer dia, 1.0mm thick ISI marked for Air conditioners.
Standard strainer & capillary tube of compressor for 1.5 TR Split/Tower type A/C as per Technical parameter of existing strainer & capillary tube installed by OEM in AC.
Standard strainer & capillary tube of compressor for 2.0 TR Split/Tower type A/C as per Technical parameter of existing strainer & capillary tube installed by OEM in AC.
Hermatically sealed, uncut rotary type compressor for 1.5 TR capacity Split/Tower type AC as per Technical parameter of existing compressor installed by OEM in AC.
Hermatically sealed, uncut rotary type compressor for 2.0 TR capacity Split/Tower type AC as per Technical parameter of existing compressor installed by OEM in AC.
Hermatically sealed, uncut rotary type compressor for 200 Ltr capacity Deep Freezer as per Technical parameter of existing compressor installed by OEM in Deep Freezer.
Hermatically sealed, uncut rotary type compressor for 400/500 Ltr capacity Deep Freezer as per Technical parameter of existing compressor installed by OEM in Deep Freezer.
Hermatically sealed, uncut rotary type compressor for 255 Ltr capacity Refrigerator as per Technical parameter of existing compressor installed by OEM in refrigerator.
Referigent gas R-22.
Referigent gas R-134a.
Referigent gas R-32.
LCD/LED display unit for Split type AC of 1.0TR/1.5 TR/2.0 TR capacity.
Air equalizer for Split type AC of 1.0TR/1.5 TR/2.0 TR capacity.
Swing motor of indoor unit of Split type AC 1.0 to 2 TR capacity as per Technical parameter of existing motor installed by OEM in ACs.
Indoor fan motor capacitor for split AC 1.0/2 TR capacity.
Outdoor fan motor for 1.0 to 2.0 TR Capacity Split type AC as per Technical parameter of existing outdoor fan motor installed by OEM in ACs.
Outdoor fan Blade for 1.5 TR Capacity Split type AC as per Technical parameter of existing fan blades installed by OEM in ACs.
Outdoor fan Blade for 2.0 TR Capacity Split type AC as per Technical parameter of existing fan blades installed by OEM in ACs.
Service Valve suitable for 5/8 inch outer dia copper tubing.
Service Valve suitable for 1/2 inch outer dia copper tubing.
Service Valve suitable for 3/8 inch outer dia copper tubing.
Service Valve suitable for 1/4 inch outer dia copper tubing.
Condensor Coil for outdoor unit of split AC 1.5 TR capacity as per Technical parameter of existing Condensor Coil installed by OEM in ACs. .
Condensor Coil for outdoor unit of split AC 2.0 TR capacity as per Technical parameter of existing Condensor Coil installed by OEM in ACs. .
Overload protection relay for deep freezer of capacity 200 Ltr as per Technical parameter of relay installed by OEM in deep freezer .
Overload protection relay for deep freezer of capacity 400/500 Ltr as per Technical parameter of relay installed by OEM in deep freezer .
Cooling fan unit for deep freezer of capacity 200 Ltr as per Technical parameter of cooling fan unit installed by OEM in deep freezer.
Cooling fan unit for deep freezer of capacity 400/500 Ltr as per Technical parameter of cooling fan unit installed by OEM in deep freezer.
Thermostate switch for referigerator 165 to 255 ltrs capacity of reputed make.
Compressor relay for refrigerators of any capacity.
Bimetal thermostate for refrigerator for nofrost system
Thermal fuse for refrigerator for nofrost system
Timer for Refrigerator for nofrost system
Supply and fixing three core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt of size 4sqmm, conforming to IS 694 complete all as specified and directed. Make Havells/ Nicco/ KEI/ Finolex/ Polycab
Supply and fixing three core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt of size 2.5sqmm, conforming to IS 694 complete all as specified and directed. Make Havells/ Nicco/ KEI/ Finolex/ Polycab
Supply and fix sheet metal enclosure with socket and a two pin and earth plug top and MCBs 20 amp, 240 V complete all as specified and directed. Make: L&T/ Siemens/ Schneider/ Hagger/ Legrand/ ABB/ Havells
M/s Gupta Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .