Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 CrAccepted-AOC | ₹4.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.2 Cr+₹42.1 L (8.77%)Rejected-Finance | ₹5.2 Cr+₹42.1 L (8.77%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹5.3 Cr+₹47.7 L (9.93%)Rejected-Finance | ₹5.3 Cr+₹47.7 L (9.93%) | L3 | Rejected-Finance Other than L1 |
Tender Value
₹4.1 Cr
EMD Value
₹4.8 L
Closing Date
27 Feb 2023, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune PIN- 411001
PROVISION OF OTM ACCN FOR SIG COY AT AURANGABAD
2022_MES_564309_2
CA NO. CEPZ/DEO/TOKEN-36 OF 2021-22
Open Tender
Civil Works
Lump-sum
750 days
Aurangabad
Class A category a(i)
Also refer NIT
8 documents required · 8 mandatory
₹2,000
GE South Ahmednagar
₹4.8 L
Yes
30 Mar 2023
31 Jan 2023
1 Mar 2023
31 Jan 2023
27 Feb 2023
7 Feb 2023
1 Feb 2023 - 4 Feb 2023
Amount
SCH 'A' PART-I: BUILDING/STRUCTURES Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Construction of Block of Single living accn for 12 Hav and 38 ORs including Cook house & Dining hall complete all as shown in drawings and as specified.
Construction of Block of MT office and MT store complete all as shown in drawings and as specified.
Construction of Block of LPG Store compete all as shown in drawings and as specified.
Construction of Block of FOL store complete all as shown in drawings and as specified.
Construction of Block of Repair bay with Inspection pit (as per details shown in drawing No. CEPZ/91/TD/33M sheet 1/1) including apron complete all as shown in drawings and as specified.
Construction of Block of Religious Institute complete all as shown in drawings and as specified.
Construction of Block of Storage Accn complete all as shown in drawings and as specified.
Construction of Block of Parking shed for 25 scooters including ramp on both sides complete all as shown in drawings and as specified.
Construction of Sentry Box Type-'B' complete all as shown in drawing No. CEPZ/91/TD/18M sheet 1/1 and as specified.
Construction of Fire Point complete all as shown in drawing No. CEPZ/94/TD/42 sheet 1/1 and as specified.
Construction of Alarm Post complete all as shown in drawing No. CEPZ/2021/TD/03 sheet 1/1 and as specified.
Construction of Static Water Tank of 50000 litres capacity complete all as shown on drawing No. CEPZ/2022/A' BAD/01/STR sheet 9A/9 and as specified.
Total amount of Sch ‘A’ Part II (Internal Water supply)
Total amount of Sch ‘A’ Part III (Internal Electric Supply)
Total amount of Sch 'A' Part-IV (Road, Path and Culverts)
Total amount of Sch ‘A’ Part V (Area drainage)
Total amount of Sch ‘A’ Part VI (Sewage Disposal)
Total amount of Sch ‘A’ Part VII (Solar Hot Water System)
Total amount of Sch 'A' Part-VIII (External Water Supply)
Total amount of Sch 'A' Part-IX (External Electric Supply)
Total amount of Sch 'A' Part-X (Compound Wall, Fencing and Gate)
Total amount of Sch 'A' Part-XI (Site clearance, excavation and earthwork)
NOTE: Schedule ‘A’ Part II to XI items which are not Prepriced by MES, Bidders shall insert their rate in Column-6 only and the Estimated rate indicated as "0.0" are for that purpose.
SCHEDULE 'A' PART-XII (MISC B/R AND E/M WORKS)
Supply , installing and commissioning of Refrigerator, electric driven, single phase AC 230 Volts 50 Hz of capacity not less than 310 litres, double door type, frost free, minimum BEE 5 star rated including connecting lead and suitable 3 pin plug top complete all as specified and directed. (Make:- Samsung/LG/Godrej/Whirlpool).
Supply , installing and commissioning of Water Cooler electrically driven single phase, fully stainless steel body having approximate storage capacity of 40/80 litres/hour and cooling capacity 40 litres/hour, including connecting lead and suitable 3 pin plug top complete all as specified and directed. (Make:- Voltas/Usha/ Godrej).
S&F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and design for input variation between 170 volts to 250 volts with output voltage stabilized at 230 volts with accuracy of ± 2.5 % of capacity 2.00 KVA including all fixing arrangement complete all as specified and directed.
S&F Lamp holder PVC / Polycarbonate type with back plate including LED lamp 5 Watt suitable for batten fittings, complete all as specified and directed.
S&F LED light fitting 1 x 9 Watt / 1 x 10 Watt bulk head luminaries including LED light driver holder including LED lamp and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F LED light fitting of 38 / 40 Watt capable of delivering 3900 lumen, having PC diffuser, luminous efficiency of > 100 lumen / Watt, CRI > 80, PF > 0.9, CCT 6500 K, independent isolated SMPS based constant current electronic LED driver with THD < 20 %, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec 13) - 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing, white coloured ABS end caps, IP 20 protection, input voltage range 140 - 270 Volts, input frequency 50 - 60 Hz, including electric connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. (Make: Philips Cat Part No. SP680P LED39S 6500 PSU WH L120 S1 or equivalent model of Havells Cat Part No. DESTELLO50LP /S36WLED840SPMMAWH or Wipro Cat Part No. LE11-491-XXX-57-XX).
S&F LED light fitting 1 x 20 Watt, 230 Volts AC, decorative box type with driver holder including LED tube light and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. (Make: Havells Cat Part No. INDURALINEARNEOBS20WLED865SPCWH or equivalent in makes as per Appendix 'C').
S&F LED light fitting 1 x 11 Watt, 230 Volts AC, decorative box type with driver holder including LED tube light and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. (Make: Havells Cat Part No. INDURALINEARNEOBS10WLED865SPCWH or equivalent in makes as per Appendix 'C').
S&F LED light fitting, out door building security light of 25 to 30 Watt fixture consisting of extruded aluminium extrusion housing with PC diffuser, LED fixture system wattage of 36 W / 40 W, 140 V - 260 V AC, system lumen output min 3960 lumen in 36 W or 4400 lumen in 40 W with 5700 - 6500 K CCT with CRI > 85, PF > 0.95 and THD < 10 % with minimum 2.5 KV surge protection in built and complete LED fixture with BSI R mark and R Registration No. and including bracket made of 40 mm dia GI tube light grade, bent to shape required including 2 Nos of flat iron brackets duly welded with nuts, bolts and washers etc., including electric connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. (Make: Philips Cat Part No. SM 365C LED 32-6500 PSU OD WH or Havells Cat Part No. ENDURAPEARLSL25WLED757SASY TOPC r equivalent in makes as per Appendix 'C').
S&F Ceiling fan complete with fan blades, down rod, electronic regulator and accessories, 230 Volts, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC), complete and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F Ceiling fan complete with fan blades, down rod, electronic regulator and accessories, 230 Volts, 1400 mm sweep, minimum air delivery 245 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC), complete and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F Exhaust fan, steel body, AC single phase, 230 Volts, 300 mm sweep with blades, frame and louvers, complete all as specified and directed.
S&F Exhaust fan, steel body, AC single phase, 230 Volts, 380 mm sweep with blades, frame and louvers, complete all as specified and directed.
S&F Power line vertical TPN DB suitable for and including 160 Amp MCCB incomer, double door (IP-54 protection), 4 ways, built in 250 Amp copper bus bar for each phase complete suitable for 415 Volts AC, 50 Hz complete all as specified and directed. (Make: Legrand Cat No. 507752 or or equivalent in makes as per Appendix 'C').
M&L Cutting existing cast iron main of size 200 mm dia in position for and reducing to required length before laying in position for insertion of new tees, branches etc for 80 mm branch connection including necessary excavation and earthwork and making good surfaces complete all as specified and directed.
M&L Construction of Fly ash bricks masonry Valve pit chamber of size 0.90 x 0.90 x 0.90 mtr (depth) internal dimensions with 15 cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hard core, 23 cm thick fly ash brick wall built in cement and sand mortar 1:4, 15mm thick internal plaster including 50 mm thick PCC 1:3:6 bedding, 3mm thick MS sheet cover with 40mm x 40mm x6mm MS angle iron frame fixed in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) coping with 25mm x 6mm flat iron hold fast with handle and locking arrangement including necessary painting steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer, excavation, earth work, returning & filling in type of soil and disposal of surplus soil at a distance of not exc. 50 m, complete all as specified.
Supply, install, testing & commissioning step down distribution Transformer of capacity 100 KVA, outdoor type, energy efficient level-III confirming to IS: 1180 (Part-I) 2014, copper wound, HT-11 KV, 3 phase, LT- 433 Volts 50 Hz AC 3 phase, oil immersed, naturally air cooled. delta connected on primary side (11 KV HV side) and star connected on secondary side (433 V LV side) in accordance with vector group DYN 11 with neutral brought out on secondary LV side with tapping at ± 2.5% ± 5 % ± 7.5 % off load tap changer gear in steps of 2.5% including initial oil filling to appropriate level having dielectric breakdown strength ≥50 KV and all standard fittings a per IS: 1180 Part-I, 2014, mounted on and including PCC platform, fencing and steel gate as per TD Drg No CEPZ/98/TD/6. The unit rate of transformer shall include the following accessories / fittings / specifications:-
(a) Non detachable rating & terminal marking plates
(b) Lifting lugs for main tank and top cover.
(c) Earthing terminals with lugs - 02 Nos
(d) Thermometer pocket with cap along with dial type thermometer - 01 No
(e) Externally hand operated off circuit tap changing device with locking arrangement.
(f) Oil conservator tank with oil filling hole & cap and oil level gauge.
(g) Silica gel dehydrating breather with first charged silica gel.
(h) Top filler valve with plug.
(j) Drain cum bottom filter valve with plug.
(k) Air vent, explosion vent, flings etc.
(l) Unidirectional reversible roller - 04 Nos
(m) HV bushing - 03 Nos
(n) LV bushing - 04 Nos
(o) First fill oil.
(p) Base channel 100 x 50mm, 460 mm long with holes to make them suitable for fixing on a platform or plinth including making locking arrangement.
(q) First fill of fresh oil confirming to relevant IS and tested upto 50 KV dielectric strength.
(r) Extra bushing for neutral outside the L.T. cable box for providing independent earthing for neutral.
(s) Provision of two numbers danger boards 250 x 200 mm size made out of 1.6 mm this MS plate, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour, one at H.T. side and other on L.T. side.
(t) Any other fittings /accessories so as to confirm the whole transformer to IS:1180-2014.
NOTES:
i) Contractor shall submit technical, constructional and safety features drawings for approval of GE.
ii) Acceptance of transformer shall be subject to factory inspection for routine tests as per IS & ANSIC-57.12.90 (latest revision) in the OEM factory in presence of rep of Accepting Officer before dispatch from factory and tests after installation by SEI of Zone.
S&F LED street light fitting complete with all fitting & fixing accessories, 35/36 Watt 230 volts AC, outdoor type, made out of high pressure die cast aluminium housing and heat resistant glass and high efficient electronic driver, lamp bracket with impact and corrosion management in multiple optic, IP 65/66 thermal protection, prewired, connected and fixed on walls PCC/Steel poles etc. complete as specified and directed.
S&F FRP junction box of size 250 mm x 200 mm x 100 mm (depth) suitable for pole mounting including MCB SP 6 Amp complete with connection fro loop in and loop out cable connector with suitable size cable glands and clamp made out of flat iron 40 x 4 mm including connecting from the junction box to street light with suitable size cables complete all as specified and directed.
S&F Dropout fuse unit expulsion type for outdoor air break switch (GOD) single pole, mounted on and including insulators for 11000 Volts working pressure fixed to and including MS channel with nuts, bolts, washers etc., synthetic bounded fuse carrying tube complete with line tabs and suitable for current carrying capacity upto 10 -60 Amp only all as specified and directed.
(a) MCCB Four pole, 160 Amp, 35/36 KA, 415 Volt with overload & thermal release setting : 01 No. (Incoming).
(b) MCCB Four pole, 32 Amp, 25 KA, 415 Volt with with overload & thermal release setting : 02 Nos. (Outgoing).
(c) MCCB Four pole, 20 / 25 Amp, 25 KA, 415 Volt with with overload & thermal release setting : 03 No. (Outgoing).
(d) Astronomical time switches 415 volt three phase suitable for Indian Region longitude / latitude with 3 pole ML-2 pole contactor suitable for 16 Amp complete with all accessories : 01 No.
(e) Copper bus bar 250 Amp with 4 Nos strips of suitable size : 01 Set.
(f) Phase indication lamp LED type for indicating R-Y-B phases with back up HRC fuse : 01 Set (3 Nos).
(g) Digital Volt / Amp /Frequency meter : 01 No.
(a) MCCB Four pole, 32 - 40 Amp, 10 KA, 415 Volt with with overload & thermal release setting : 01 No. (Incoming).
(b) MCB TPN 16 Amp 10 KA : 03 Nos (Outgoing)
(c) MCB DP 16 Amp 10 KA : 03 Nos (Outgoing)
(d) Phase indication lamp LED type for indicating R-Y-B phases with back up HRC fuse : 01 Set (3 Nos).
(e) Digital Volt / Amp /Frequency meter : 01 No.
S&F Cable route indicator made out of cast iron and embedded on HT cable route having plate of size 80 mm dia and 5 mm thick and leg of suitable size including grouting in and including PCC 1:3:6 Type C-1 foundation block of suitable size and necessary excavation and earthwork all as specified and directed.
S & F Street light brackets made out of 40 mm dia GI light grade pipe 1.20 m length bent to shape required for fixing on pole and suitable for LED street light fittings with 2 Nos MS flat iron 40 mm x 6 mm clamp of suitable size with necessary GI screws and bolts including painting two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L PVC 3 core copper wire flexible type of size 1.50 sqmm in PVC conduit 20 mm dia for street light connection of length as per site requirement from junction box to street light complete all as specified and directed.
Provide Provision Sum for Rs 2.00 Lakh for constrution of Volly ball ground/ Court all as per details shown in Drawing No. CEPZ/2018/TD/11 sheet 1/1 and as directed.
nhsaluji and associates
D V Engineers and Contractors Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .