Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹23.6 L+₹1.3 L (5.93%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹24.8 L+₹2.6 L (11.6%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹25.6 L+₹3.4 L (15.1%)Rejected-Finance | L4 | Rejected-Finance Not lowest |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
13 Oct 2022, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2022_MES_552477_1
GE/NRC/8928/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Nasik Road
₹48,000
Yes
26 Nov 2022
16 Sept 2022
15 Oct 2022
16 Sept 2022
13 Oct 2022
29 Sept 2022
Amount
Excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out.
Returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc. 25cm all as specified and directed by Engr-in-Charge.
Removing excavated soil n.exc 50 mtr and depositing where directed at a level n. exe 1.5mtr above the starting point all as specified and directed.
M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 90mm and innter dia 78mm including 90 degree bends with coupler and rubber ring laid in trenches of size 90 mm suitable for cable protection of 70 sqmm to 95 sqmm complete all as specified and directed.
M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 40mm and innter dia 28mm including 90 degree bends with coupler and rubber ring laid in trenches of size 40 mm suitable for cable protection complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down and hanging during point wiring of ceiling fan/exhaust fan of any size and sweep in proper manner and connecting up including provision of cable from ceiling rose or connector to fan all as per specified and directed by Engr-in-Charge
Dismantling unserviceable main switch/DBs with MCBs and wooden board including making good disturbed surface of wall.
Dismantling carefully the existing U/S LT/HT Overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as directed by Engr-in-Charge.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces.
M&L for Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface for One light point controlled by one, one way switch all as directed and specified. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
All as per Item No. 11.00 but One ceiling /exhaust fan point controlled by one switch and regulator
All as per Item No. 11.00 but One 3 pin 5 amp socket out point on the same board with other switches.
All as per Item No. 11.00 but One3 pin 5 amps socket out let point on independent board
All as per Item No. 11.00 but One bell/buzzer point controlled by one bell push.
All as per same in item No 11 above but for one socket outlet 15 amp on independent board with 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire.
S&F Switch piano flush type single pole one way 5 amps.
S&F Socket outlet 2 in 1, 3 pin, 6A
S&F Switch socket combination 2 in 1, 6A flush type
S&F Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal
S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body
S&F Buzzer, Ding Dong AC. 230 volts, single pole
S&F Bell push, flush type, 5 amp.
S&F Electronic regulator 100/120 Watt step type
S&F Lamp holder insulated body with back plate for angle holder including 9W LED Lamp all as per specified.
S&F in repair SP&N enclosure with 2 pole and earth metal plug & socket for incorporating 10 A / 20 A SPN / DP MCB complete all as specified and directed.
S&F LED lights fitting 1x 20W, 220V, AC, decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete..
S&F round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete..
S&F round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete..
M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC CASING CAPING not less then 20mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 2.5 sqmm and one wire of 2.5 sqmm for earthing and one run of PVC casing/caping shall be measured as one unit.
M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through and including PVC duct of size 45X25 MM (BXH), ISI (make-legrand) fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- (1) Two wires of 6 sqmm and one wire of 6 sqmm and one run of PVC duct of size 45X25 MM (BXH) shall be measured as one unit. (2) Cutting chases/Cutting of wall to through sub main from wall wooden panel and making good disturbed surface including painting and finishes to match with the adjoining surface shall be included in the unit rate. .
S&F 12 way TP&N Vertical Loadline DBs in double door suitable for TP/FP'A' Frame MCCB-250A , breaking capacity : 10 kA / 16 kA / 25 kA/50kA , Bus Bars, Neutral Links, Blanking Plates without out MCCB, HSN Code - 8537, complete all as specified and directed by Engr-in-Charge,
S&F in repair Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 12 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed.
S&F Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 8 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed.
S&F Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 4 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed.
S&F MCB, single pole and neutral, 240 Volts , 40-63 Amps all as specified and as directed.
S&F MCB, single pole and neutral, 240 Volts , 6-40 Amps all as specified and as directed.
S&F MCB singal pole 240 Volts , 32 to 63 Amps all as specified and as directed.
S&F MCB singal pole 240 Volts , 6 to 32 Amps all as specified and as directed.
S&F in repair MCCB, 125 Amps , 415Volts, 16KA ,4 pole.
M&L for sub main wiring for UPS connection using PVC insulated unsheathed, stranded copper conductor cable 1 Single core of size 2.5 Sqmm to be drawn through exsisting PVC duct of any make and type fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- One wires 2.5 sqmm shall be measured as one unit.
M&L for Point wiring (UPS cocnnectioin) with PVC insulated unsheathed stranded copper conductor cable of size 1.50 Sqmm to be drawn through exsisting PVC medium grade surface PVC conduit/casing capping/concealed point including all necessary wall cutting and making good disturbed surface all as directed and specified. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
Dismantling and refixing of wooden wall peneling of any type and size including provn of material used for dismantling and refixing (i.e screw, bottom pieces e.t.c) complete all as specified and directed by Engr-in-Charge.
M&L for fabrication of framed work for panel board suitable for fixing item N-34.00 to 37.00 (12 way TP&N Vertical Loadline DBs-1 No, 12 Way SPN DB-02 Nos, 8 Way SPN DB-01 No, 4 Way SPN DB-01 No) mounted on wall shouldered and/or riveted, or forged into spikes; iron doors, MS plate of size 5MM, angle of size 40MMX40MMX5MM and similar work conforming to Fe.290.Gde-E-165 and extra only over Item 10007 for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, MS aldrop etc.
M&L for particle board of thickness 16MM, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to MS panel board or as specified and directed by Engr-in-Charge.
S&F XLPE insulated armoured and PVC sheated heavy duty electric cable size of 2 x 10 sqmm aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendment laid in tranches passing through pipes /ducts including testing complete
All as per Item No. 48 but size of 4 x 10 sqmm
All as per Item No. 48 but size of 3.5 core 70 sqmm
All as per Item No. 48 but size of 3.5 core 95 sqmm
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved aluminium bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.00 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs cable gland and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:- (A) Incoming:- (a) Aluminium bus bar TPN 400 Amps - 01 Set (i) Denger notice plate/ sticker of suitable size on front panel board -01 No (ii) MCCB 3 pole 200 A 36 kA- 01 No (B) Outgoing:- (i) MCCB TPN 100 Amps 03 No (ii) MCB TPN 63 Amps -01 No (iii) Each outgoing Feeder Name Radium Sticker Inside Panel.
M&L for fixing MS enclosure made out of CRCA sheet 3.00mm thick of size 600mm x 600mm x 300mm depth with aluminium bus bar mounted on epoxy insulators, & fixing arrangement with suitable MS Clamps all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode size 600x600x6.3mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth strip of size 32 x 6mm dia by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. PCCI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion
M&L for Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mm dia by means of bolts ,nuts ,check nuts and washers including earthing pit , charcoal, common salt ,earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long, PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work of any type of soil/strata all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Supply and laying GI tubing medium grade with all fittings and fixed complete laid in trenches of size 80 mm
All as per Item No. but size 50 mm
All as per Item No. but size 25 mm
All as per Item No. but size 15 mm
Supply and fix Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete of size 50mm dia.
Supply and fix CI sluice valve both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed of sizes 80 mm dia
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
M&L for provision of staging / platform of outer size 2.5m length x 1.50m width and 1.0 mtr height made up of 230 mm thick brick wall allround including excavation, with PCC foundation 450mm wide & 100 mm thick 1:4:8 type D-2. The hallow gap should be filled with murum and well consolidated. The top of platform should be finished with 100mm thick PCC 1:3:6 type C-2 and concrete top surface should be finished with cement morter 1:6 using extra cement. The allround plinth protection 500mm wide of PCC 1:3:6 type C-2, 75mm thick finish even smooth without using extra cement. The external surface of platform should be plaster with 15mm thick in CM 1:6 and apply three coat of white wash complete all as specified and directed by Engineer-in-charge.
M&L for construction of masonry valve pit chamber make up of 230mm thick brick masonary of internal dimension 1.0 x 1.0 x 1.10 mtr depth with sub class 'B' bricks in cement mortar (1:4) and 10mm thick plastering in cement mortar 1:4 and PCC (1:4:8) type D-2 in foundation PCC (1:3:6) type C-1 as in bedding and PCC (1:2:4) type B-1 in coping including 40 x 40 x 6 mm MS angle iron frame, 3mm thick MS cover plate with locking arrangement and painting to all steel surfaces with two coats of synthetic enamel paints over a coat of red oxide primer complete all as per specified and directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I® of 1000 Ltr capacity.
Bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed to bore of pipe 15mm.
Supply and laid spigot and socketed CI fittings. Such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc of size 200mm to 300mm dia.
M&L for run lead joints complete for water mains with spigot & socket pipes and fittings, all as specified and directed. 150 mm Bore of pipe
Cutting of existing CI/DI tubing for alteration or additions and insertion of Tee 150mm, union, socket all as specified and directed.
NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS. 30,990.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
sapana enterprises
MAHIMA CONSTRUCTION
SHRI SULAI ELECTRICALS
Bidder Name
SHRI SULAI ELECTRICALS
sapana enterprises
MAHIMA CONSTRUCTION
M/s Ravi Electrical
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .