Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC 1ST FLOOR GURJEET MARKET DHANGU ROAD | L1 | Accepted-AOC Accepted | |
| 2 | L2₹40.0 L+₹1.1 L (2.84%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹40.5 L+₹1.6 L (4.15%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹46.0 L+₹7.1 L (18.3%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹52.5 L+₹13.6 L (35.0%)Rejected-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun Pin-145001
REPAIR/ REPLACEMENT OF LT DISTRIBUTION SYSTEM AND CONNECTED ITEMS AT D-III, D-IV ZONE, MAP BHASKER AND DIA AREA UNDER AGE E/M -I OF GE (N) MAMUN
2023_MES_575319_1
GE(N)/M-58/2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹80,000
13 Mar 2023
16 Jan 2023
15 Feb 2023
16 Jan 2023
13 Feb 2023
31 Jan 2023
Amount
Taking out old u/s LT busbar chamber box of any size/type complete all as specified and directed.
Supply, install, testing and commissioning in replacement LT busbar chamber box, indoor type, wall mounted, made out of CRCA sheet 2.00 mm thick, CPRI approved, weather proof, dust and vermin proof, IP-43, powder coated with 8 tank process, with common electrolytic, sleeve insulated Aluminium bus-bar 100 Amps, 3 phase 4 wire system, 415 volts AC, single side openable, and locking arrangements for compartment grouting on wall in PCC 1:1.5:3 type A0 using 12.50mm graded stone aggregate including MCCB of 63 Amps, 4 pole, 415Volts, 50Hz with fixed magnetic and fixed thermal complete all as specified and directed.
Taking out LT cable,1100 volts grade heavy duty, aluminium conductor of size upto 35 Sqmm from trench/cable duct/through wall/pole carefully, removing defective length and stacking aside for re use or for taking credit to contractor all as specified and directed. Note: Excavation and other earth work shall be measured and paid seperately under relevant item.
All as per Srl Item 6 here in above but of size 70 sqmm
All as per Srl Item 6 here in above but of size 150 Sqmm to 185 Sqmm
Laying only cable of size 35 sqmm all as specified and directed.
Laying only cable of size 70 sqmm all as specified and directed.
Laying only cable of size 150 to 300 sqmm all as specified and directed.
Supply, laying, connecting and testing in replacement XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core with aluminium termination lugs, laid in trench/cable duct/through wall/pole and making good disturbed surface complete all as specified.
All as above mentioned in item No 12 here in above but Size 70 sqmm 3.5 core
All as above mentioned in item No 12 here in above but Size 150 sqmm 3.5 core
All as above mentioned in item No 12 here in above but Size 185 sqmm 3.5 core
All as above mentioned in item No 12 here in above but Size 300 sqmm 3.5 core
Taking out old u/s GI tubing of any size/any type complete all as specified and directed.
Supply and fixing in replacement of GI tubing, medium grade 100 mm bore with fittings laid for protection of cable under road crossing, fixed to walls or pole including necesary PCC grouting on wall complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
Supply and fixing in replacement of GI tubing, light grade 40 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
Taking out and Material and Labour in replacement for PVC insulated un sheathed industrial cables copper cable conductor of 1100 Volts grade confirming to IS-694/2010 of size 10 sqmm single core including necessary connection busbar to DB box having suitable size of flexible conduit pipe including taking down old u/s complete all as specified and as directed.
Taking out old u/s flood light fittings of any type complete all as specified and directed.
Supply and fixing 120 Watt, lP66 LED Flood light luminaries comprising of Die cast aluminium housing with weather proof gasket of lamp and driver compartment with 120 degree view angle, lumen output > 120 Lum/ watt, lumen maintenance> 70 % at 50000 hrs, color temp 5000-6500K, CRI > 70, THD < 15%, PF > 0.95 and LM 80 test compliance. The driver must be integrated APFC with short circuit protection, reverse polarity protection against 5KV high surges and comply with IEC 60598-1, IEC-61000-3-2, IEC 61547. The luminaire must have secondary optics with perfectly matched lens for better light control with and making electrical connections with twin core twisted copper conductor flexible copper wire of suitable size from street light to junction complete all as specified and as directed.
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
Supply and fixing in replacement of DWC HDPE 75mm bore pipe laid for protection of cable under ground ,floors, fixed to walls or pole including taking down complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
All as per item 26 but 100mm bore pipe.
Material and Labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregrate for coping of poles and foundation of stay complete all as specified.
Material and Labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete including necessary form work complete all as specified.
M&L for Cable end jointing kit, heat shrinkable, 1100 volts grade complete with jointing material and accessories suitable for 2/3.5 core XLPE armoured aluminium conductor cable of size 35-50 sqmm size. Note: Cost of excavation, returning filling, removal if required shall deemed to be included in quoted rate.
All as per item 30 but for cable of size 70 -150 sqmm size.
All as per item 30 but for cable of size 150-300 sqmm size.
Supply, install, testing and commissioning in replacement LT busbar chamber box, indoor type, wall mounted, made out of CRCA sheet 3.15 mm thick, CPRI approved, weather proof, dust and vermin proof, IP -54, powder coated with 8 tank process, single side openable, and locking arrangements for compartment grouting on wall necessary PCC work including of Air Circuit Breaker 415 volts ,630 amps, 3 pole,50 KA breaking capacity have inbuilt - 2NO+2NC Aux contact , door sealing frame & push - button cover complete all as specified and directed.
S&F in replacement MCCB 3 pole 415 volts , fixed type 100 Amps with breaking capacity 16 KA, fixed thermal & fixed magnetic release with Ics = 100% Icu, including spreadres after taking out old U/S one all as specified and directed.
S&F in replacement MCCB 3 pole 415 volts fixed type 200 Amps with breaking capacity 25 KA, fixed thermal & adjustable magnetic from 5 to 10 In with Ics = 100% Icu including spreadres after taking out old U/S one all as specified and directed.
S&F in replacement MCCB 4 pole 415 volts fixed type 100 Amps with breaking capacity 16 KA, adjustable thermal from 80 to 100% & fixed magnetic release with Ics = 100% Icu , including spreaders after taking out old U/S one all as specified and directed.
S&F in replacement MCCB 4 pole 415 volts adjustable type 200 Amps with breaking capacity 25KA adjustable thermal from 80 to 100% & fixed magnetic release adjustable from 5 to 10 In with Ics = 100% Icu, including spreaders after taking out old U/S one all as specified and directed .
S&F in replacement MCCB 4 pole 415 volts fixed type 400 Amps with breaking capacity 36KA thermal release adjustable from 80 to 100% & magnetic release adjustable from 5 to 10 In with Ics = 100% Icu, including spreaders after taking out old U/S one all as specified and directed .
Dismantling aluminium conductor of LT OH line after unbinding from insulators for replacement /re-stringing of damaged conductors including seggregating serviceable/unserviceable conductors for re-use or for shifting to MES store for taking credit to contractor all as specified .
Restringing of dismantled aluminium conductor on LT OH line with new aluminium binding wire including stretching with 3% sag, re-connecting of all cables disconnected jumpers with proper jointing with binding wire complete all as specified.
M&Lfor ACSR of LT OH line including securing with insulators using aluminium binding wire, jointing jumpers etc including all disconnected cables, jumpers with proper binding complete all as specified.
Dismantling earth wire from LT OH line after unbinding from pole for re-use or for shifting to MES store for taking credit to contractor all as specified .
Restringing and restretching dismantled earth wire from LT OH line including securing with insulators using GI binding wire complete all as specified.
M&L for Galvanised steel earth wire of service feeder or distributor span of street light polesincluding binding with insulators using GI binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified .
Dismantling cross-arms of M.S. channel or angle sections etc from LT poles complete and setting aside for re-use or shifting to MES store for taking credit to contractor all as specified.
Fixing only the cross arms items with supports/ angle iron frame etc incl nut, bolt, washer, welding, bending, hot or cold drilling holes for insulators bolts in any size or shape complete all as specified.
Material and labour for replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed ,welding and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified.
Dismantling and taking old/UNSV stay assembly including Stay wire and insulator complete all as specified .
M&L for replacement stay assembly complete with MS stay plate of size 300x300x6mm thick, stay rod 20 mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I, 2009 ( Excavation, PCC, saty wire and loop type insulators will be measured separately) complete all as specified and directed.
M&L for galvanized stay strand of 7/4mm size complete all as specified and directed.
M&L for loop type insulator large size with overall dimensions (90 x140) mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified .
Dismantling insulators of any type, any size complete all as specified .
Fixing only shackle type insulators all as specified .
Fixing only pin type insulators all as specified .
M&L for shackle type insulator,100 mm height,115 mm dia, 31x5 mm strap,14 mm dia bolts Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, as under: complete all as specified.
M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified.
Dismantling old unserviceable concrete pole/Strut any size and shifting n.exceeding 50 meters, setting aside for disposal action all as specified and directed.
Material and labour for prestressed cement concrete pole 9 mtr long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10 complete, erected truly in vertical position and painting the poles with alternate layer of 30 cm, black and yellow paint with two coats of synthetic enamel over a coat of primer upto 1.5 mtr above from the coping complete all as specified and directed.
Supply and fix in replacement electronic driver suitable for LED fittings 45 watts any type and make (as per sample) all as specified and directed.
Trimming up of tree branches upto 1.5 mtr all around LT overhead lines, removing cut branches from site complete all as directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 1.5 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department accordingly. The trimming work shall be commenced once it is permitted by AGE/JE. (ii) only effective length i.e length where tree branches are touching LT line or neaby HT line shall only be measured & paid under this item. No claim whatsoever shall be entertained by the deptt at later stage. (iii) Fortnightly inspection of lines will be made jointly by contractor or his authorised rep and rep of Engr-in-Charge and outcome whether lines are free from tree branches or not kept on record for payment. (iv) The OH line will be maintained for whole period of contract and full payment will be made with Final Bill only. The payment for the period for which line not maintained will be deducted proportionately based on fortnightly inspection carried out as detailed above.
Restretching ACSR, GI wire of LT OH line running on poles by means of pulling jack maintaining sag not more than 3% in each span including replacment all binding wires in between all span and on terminations including jointing of all cable, jumper connection provided with new binding wire or jumpers complete all as specified and as directed. Note : Rate include deemed to be each span of 5 nos of conductors
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected by 25X4 mm GI strip as earth lead by means of nuts and bolt, thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20 mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x 300 mm dia,15 mm thick plaster in CM 1:4 funnel with wire guage mesh ,80 mm thick RCC pit cover 320mm x 320 mm of RCC 1:2:4 Type B1 using 20 mm graded stone aggregate reinforced with XPM jally. Charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part -1 (1991) and specified including provision of GI strip upto 7.5 metre long protected by 40 mm dia light grade pipe and watering pipe shall be 20 mm bore medium grade ,including all excavation and earth work and connecting the earthing to an earthing test point and to main switch board as specified and testing on completion complete all as specified and directed. Note: RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover.
Deduct Total amount of SCHEDUL 'A' SECTION-II (SCH OF CREDIT) Rs 166652.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
KULBHUSHAN AGGARWAL
M/S BHATIA CONSTRUCTION
M/s USHA ENTERPRISES
M/S SHRI RAM BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .