Karnataka Power Transmission Corporation Limited
VEERESH UDEDH
Tender for the work of Dismantling, Transportation (to and fro), Repair, Testing, Erection and commissioning of sick Power Transformer of rating 20MVA, 110/33-11KV, IMP MAKE, Sl. No.PT-6902 YEAR OF MANUFACTURE 2013 LYING AT 110KV SUB STATION APMC RAICHUR IN in Raichur Taluk, Raichur district on total turnkey basis.
KPTCL/2023-24/SS/WORK_INDENT17
KPTCL/2023-24/SS/WORK_INDENT17
Open
Sub-Station
Two Tender Document System(Two Cover)
KPTCL SEE Transmission Works and Mantainance Circle Munirabad
26 documents required · 18 mandatory · 8 optional
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
The performance of the Transformer repaired / supplied by the Bidder in the past shall be a vital factor in determining the responsiveness of the tenderer. In case of substantial failure of the Transformers repaired / supplied by the Bidders in the past contracts, failure to adhere to the schedules or to meet the technical requirements and guarantees and, if the Transformer so repaired / supplied and installed were affected by persistent operational problems, damages, breakdowns etc., owing to design inadequacies, workmanship defects etc., the Bids shall be rejected.
The Bidder shall have experience of minimum 05 (five) years in manufacturing / repairing, testing and commissioning of similar or higher rating and voltage class of Power Transformer herein tendered involving designing, manufacturing and replacement of faulty windings in case of Power Transformer which has been repaired for any of the Government / public sector power utility in India which should have been in satisfactory continuous operation for at least 02 (two) years prior to the date of opening of the tender.
he Bidder should have executed either manufacture or repair on total turnkey basis (involving designing, manufacturing and replacement of faulty windings of Power Transformer) of a same or higher rating and voltage class in the past 10(Ten) years ending last day of the month previous to the one in which tender is invited for any of the Government / public sector power utility for any one of the following value of work which shall have rendered satisfactory service of at least 02 (two) years continuously a)a minimum of 60 % of the value of the tendered amount against each of 01(One) work orders on total turnkey basis OR b) a minimum of 50 % of the value of the tendered amount against each of 03 (three) distinct work orders on total turnkey basis. OR c)a minimum of 40 % of the value of the tendered amount against each of 04 (four) distinct work orders on total turnkey basis.
The Bidder should have their own repair shop with all the facility such as Crane, Oven, winding machines, etc., required for carrying out necessary repairs on Power Transformers.
Bidders shall have adequate financial stability and status to meet financial obligation pursuant to the scope of this assignment and shall meet the following minimum criteria Minimum Average Annual Turnover (MAAT) of the Bidder for best 03 (three) years out of last preceding 05 (five) financial years (on the date of tendering) ending on March shall not be less than 100 percentage of the amount put to tender.
The bidder shall submit Self declaration for not being disqualified regarding nonperformance in any of the Government utilities in the past five years
The Bidder shall have technically qualified work force with domain knowledge relating to design of Power Transformer including quality control and shall have infrastructure, testing and erection facilities and capacity to execute the works.
Power Transformer as prescribed in the latest IS:2026/1977 or any relevant standard as applicable for testing of repaired Power Transformer. The testing facilities shall have testing and measuring instruments calibrated by National Accreditation Board for Testing and Calibration Laboratories (NABL). Valid calibration reports of Testing and measuring instruments shall be uploaded to the e-portal.
The Bidder shall upload the proof of having possessed the above T&P equipment along with valid calibration certificate for testing / measuring equipment to the e-portal for verification. The Repairers who do not possess the above equipment and valid calibration reports will be treated as non-responsive and their Bids will be rejected.
The bidder shall submit Valid GSTN registration number and GST registration Certificate
The bidder shall submit Company registration Certificate
PAN CARD
The bidder shall submit self declaration regarding No litigation with KPTCL
No deviation to tender conditions
Power of attorney
Letter of undertaking
The solvency certificate shall be from a nationalized or scheduled Bank and issued within a period 12 months from the final date of submission of tender
₹1,430
₹1.0 L
25 Oct 2023
25 Oct 2023
17 Nov 2023
7 Nov 2023
Tender for the work of Dismantling, Transportation (to and fro), Repair, Testing, Erection and commissioning of sick Power Transformer of rating 20MVA, 110/33-11KV, IMP MAKE, Sl. No.PT-6902 YEAR OF MANUFACTURE 2013 LYING AT 110KV SUB STATION APMC RAICHUR IN in Raichur Taluk, Raichur district on total turnkey basis.
Tender for the work of "Dismantling, Transportation (to and fro), Repair, Testing, Erection and commissioning of sick Power Transformer of rating 20MVA, 110/33-11KV, IMP MAKE, Sl. No.PT-6902 YEAR OF ...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tender Documents_DEODURGA.doc
Tender Document • 1.02 MB
20 MVA-II ANDREWYULEMake Transformer Tentative Estimate @ 110kv DEODURA.xls
Tender Document • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .