Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | ₹6.2 L Quoted ₹6.4 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹6.5 L+₹10,868 (1.69%)Rejected-Finance | ₹6.5 L+₹10,868 (1.69%) | L2 | Rejected-Finance Higher bid value |
| 3 | L3₹6.8 L+₹38,675 (6.02%)Rejected-Finance | ₹6.8 L+₹38,675 (6.02%) | L3 | Rejected-Finance Higher bid value |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
13 Jul 2020, 6:00 pmClosed
AGE (I) (AF) PURNEA
AGE (I) (AF) PURNEA
REPAIR/REPLACEMENT OF HT UG CABLE,VCB,RMU,TRANSFORMERS AND TWO POLE STRUCTURE AND ITS CANNECTED ITEMS AT MOUZA DALAN AND SIRSA CAMP AREA AT ARMY STATION KATIHAR UNDER AGE (I) (AF) PURNEA
2020_MES_353864_1
C/8867/E8
Open Tender
Civil Works
Works
180 days
AGE (I) (AF) PURNEA
REPAIR/REPLACEMENT OF HT UG CABLE,VCB,RMU,TRANSFORMERS AND TWO POLE STRUCTURE AND ITS CANNECTED ITEMS AT MOUZA DALAN AND SIRSA CAMP AREA AT ARMY STATION KATIHAR UNDER AGE (I) (AF) PURNEA
7 documents required · 7 mandatory
₹500
AGE I AF PURNEA
₹12,000
Yes
22 Aug 2020
18 Jun 2020
16 Jul 2020
18 Jun 2020
13 Jul 2020
1 Jul 2020
Amount
M&L for open the top cover of transformer of capacity 315 KVA to 400 KVA, after disconnecting HT/LT connection, drain out of transformer oil and preserve it in container, replacement of all gasket for prevention of leaking, replacement of broken HT/LT bushes complete as per existing size all as directed, refixing all connection and testing on load.(Note : Cost of HT/LT bushes to be paid separately).
Replacement of HT bushing complete with copper spindle, checknuts oil seal, bolts nuts and washer cte complete all as directed by Engr-In-Charge.
Replacement of LT bushing complete with copper spindle, checknuts oil seal, bolts nuts and washer cte complete all as directed by Engr-In-Charge.
Replacement of breather complete sets with silica gel.
M&L in repair for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. Make RAYCHEM/DENSION /3M
M&L in repair for Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. Make RAYCHEM/DENSION /3M
M&L Topping of new transformer oil of di-electric strength not less than 60 KV after drawn out old oil complete all as specified and as directed by Engr-in-charge.
M&L for dehydration and filtration of transformer oil at site of installation for 11KV,433volts step down transformer of any capacity and any make mounted outdoor and obtaining di-electric strength minimum 60 KV with 2.5 mm gap with portable filter cum dehydration machine complete all as specified and as directed by Engr-in-charge.Note:- Testing of di-electric strength of dehydrated transformer oil of each transformer will be carried out in the presence of concerned Engr-in- charge.
Supply and fixing Rubber mat of 1 mtr x 2 mtr x 19 mm.
S&F in repair Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp 6600 Volt. Make : JAIPURIA/ALSTOM/OBLAM
M&L for Servicing / Greasing of HT Switch air break ( GOD) 11 KV TP with replacement of Corroded nut Bolts, ACSR Jumpers, making alignment of operating Mechanism for Proper ON / OFF operation of GOD and male contact including complete greasing all as directed by Engr-in-Charge.
Painting to HT Steel Tubular Two pole Structure including cross arms, MS Channels , clamps after scrapping thoroughly the existing rust / dirt / dust and corroded paint from the steel surfaces, Painting with Two coats Aluminum paint over a coat of red Oxide Primer all as directed.
S&F in repair Disc type insulator, porcelain, vitreous 145mm high and 255 mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for couductor, working pressure 11000 Volt.
M&L in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut150mm height, 150mm dia for 11000 volts grade
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for taking out defective HT UG cable alongwith PCC cover all as directed.
M&L for sand cushioning for protection of PVC cable with screen wash river sand and punning to proper required cover.
Supplying and laying un-reinforced precast concrete cable cover but class HV, Type 1, flat, size 300mmx l80mm x 40mm
M&L in repair for laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sq. mm 3 Core. Make : Havells/Gloster
Disconnecting and taking out existing Indoor HT 11 KV VCBs(Make-Areva) of 800 Amps rating from housing and cleaning, rubbing and overhauling the mechanical parts and Servicing of 11KV in door VCB, Repalcements of UNSV parts such as ,vaccum interuppter,arms ,closing and tripping coils, auxiliary switches ,protection relays,CT,PT etc.Checking the quality of insulation resistances, static contact resistance, Testing ( IR value, Ratio test, Polarity test) and connection verification of 11 KV Current transformer( Set of three) by PRIMARY INJECTION KIT after fixing of new CT ,and Testing and calibration of relay( set of two Over current and one earth fault) by SECONDARY INJECTION KIT. calibration of relays, CT connection, PT alignment, Cleaning, polishing of VCB including final testing after fixing complete including all other functional tests of the VCB, C&R panel and CTs, PTs. complete Note:- The rate of item will be measured and paid separatly.
Supply,install,Testing of Vaccum interrupter for 11 KV VCB ((Make-Areva or as approved by Engr-in-charge).
Supply and Fix upper contact arms for 11KV VCB complete all as specified and directed.
Supply and Fix Lower contact arms for 11KV VCB complete all as specified and directed.
Supply and Fix Busbar Support Insulator For 11 KV VCB complete all as specified and directed by Engr-in-charge.
Supply, Connecting and testing Closing and Tripping Coil DC 24 V/30V for 11 KV VCB Complete.Make- Areva or as approved by Engr-in-charge.
Supply ,installation, testing and commissioning of 110v DC battery bank comprising (55x2 volt) 50AH complete all as spd and directed.
S & F 3 phase resin cast draw out type Potential Transformer Having PT Ratio 11KV/1100V/3, Burden : 100 VA. CI:1.0 with primary side PT fuse including Voltmeter square type of capacity 0 to 15 KV for panel complete all as spd and directed .
Supply only PT spout complete all as specified and as directed by Engr-in-charge(Make-Areva)
Supply only PT riser complete all as specified and as directed by Engr-in-charge(Make-Areva)
Supply install ,testing and commissioning of Numerical Protection relay IDMT(03 O/C + 01 EF) with high set for 11 KV VCB panel complete all as specified and directed.
Suplply only CRC chemical 300ml capacity complete all as specified and directed.
S & F 11 KV panel indicating lamp fitting LED type suitable for 110 volt/230volt AC complete all as specified.
Supply only HT monoplast tape complete as directed.
Supply only Space Heater complete asspecified and directed.(Make- RECO/GIRISH Note:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount.
M/S. MAJUMDER CONSTRUCTION
ALAM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .