| Sl No | Description | Qty | Unit | Endress Hauser India Pvt Ltd L1 | Knowledgelens Private Limited L2 | AAXIS NANO TECHNOLOGIES PVT. LTD. L3 | Krishna Agencies L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Electromagnetic Flow meter for LP Pumps
(04 nos. Pumps for each unit) common header
Discharge Line for unit 4 &5 BTPS.
Type of Flow sensor: Full Bore Type
Medium: Clean Raw water
Fluid velocity: 2-3 m/s
material of Pipe= MS Line Line Size: 450 mm NB
Operating Pressure: 10 Kg/cm2
Maximum Pressure: 20 kg/cm2
Maximum flowrate: 1260 m3/hr | 2 | Nos. | - | - | - | - |
| 2.00 | Electromagnetic Flow meter for HP Pumps
( 04 nos. Pumps for each unit) common header
Discharge Line for unit 4 &5 BTPS.
Type of Flow sensor: Full Bore Type
Medium: Clean Raw water
Fluid velocity: 2-3 m/s
material of Pipe= MS Line Line Size:400 mm NB
Operating Pressure: 14 Kg/cm2
Maximum Pressure: 20 kg/cm2
Maximum flowrate: 800 m3/hr | 2 | Nos. | - | - | - | - |
| 3.00 | Electromagnetic Flow meter for LP Pumps
(05 Nos. for all three units of ATPS)
common header Discharge Line for unit 1,2 &3 ATPS. Type of Flow sensor: Full Bore Type
Medium: Clean Raw water
Fluid velocity: 2-3 m/s
material of Pipe= MS Line
Working Principle: Faradey Law's of Electromagnetic Induction
Line Size:500 mm NB
Operating Pressure: 6.5 Kg/cm2
Maximum Pressure: 12 kg/cm2
Wire housing: welded sheet steel
Maximum flow rate: 1000 m3/hr | 1 | Nos. | - | - | - | - |
| 4.00 | Electromagnetic Flow meter for HP Pumps
(05 nos. Pumps for all three units of ATPS) common header Discharge Line for unit 1, 2 & 3 ATPS. Type of Flow sensor: Full Bore Type
Medium: Clean Raw water
Fluid velocity: 2-3 m/s
material of Pipe= MS Line
Line Size: 450 mm NB
Operating Pressure: 10 Kg/cm2
Maximum Pressure: 20 kg/cm2 Maximum flowrate:1000 m3/hr | 1 | Nos. | - | - | - | - |
| 5.00 | Electromagnetic Flow meter for AWRS Pumps for DTPS Discharge Line for unit 6&7.
Type of Flow sensor: Full Bore Type
Medium: AWRS Pond water
Fluid velocity: 2-3 m/s
Material of Pipe= MS Line
Working Principle: Faradey Law's of Electromagnetic Induction Line Size: 800 mm NB
Operating Pressure: 12-15 Kg/cm2
Maximum Design Pressure: 20 kg/cm2
Wire housing: welded sheet steel
Maximum flowrate: 4000 m3/hr
Pressure of AWRS water:<16 kg/cm2 | 1 | Nos. | - | - | - | - |
| 6.00 | Electromagnetic Flow meter for AWRS Pumps for ATPS & BTPS Discharge Line for unit 1 to 5. Type of Flow sensor: Full Bore Type
Medium: AWRS Pond water
Fluid velocity: 2-3 m/s
Material of Pipe= MS Line
Working Principle: Faradey Law's of Electromagnetic Induction Line Size: 500 mm NB
Operating Pressure: 12-15 Kg/cm2
Maximum Design Pressure: 20 kg/cm2
Wire housing: welded sheet steel
Maximum flowrate: 3000 m3/hr
Pressure of AWRS water:<16 kg/cm2 | 2 | Nos. | - | - | - | - |
| 7.00 | Clamp ON Ultrasonic Flow meter for BALP Pumps
(03 nos. BALP for all two units of DTPS) common header Discharge Line for unit 6&7 DTPS. Type of Flow sensor: Clamp On Type
Medium: Clean Raw water
Fluid velocity: 2-3 m/s
material of Pipe= MS Line Operating Pressure: 2.5 Kg/cm2
Maximum Pressure: 5.0 kg/cm2
Maximum flowrate:1210 m3/hr.
Line Size: 400 mm NB | 1 | Nos. | - | - | - | - |
| 8.00 | Clamp ON Ultrasonic Flow meter for BALP Pumps
(03 nos. BALP for all two units of DTPS) common header Discharge Line for unit 6&7 DTPS. Type of Flow sensor: Clamp On Type
Medium: Clean Raw water
Fluid velocity: 2-3 m/s
material of Pipe= MS Line Operating Pressure: 2.5 Kg/cm2
Maximum Pressure: 5.0 kg/cm2
Maximum flowrate:1210 m3/hr.
Line Size: 300 mm NB | 1 | Nos. | - | - | - | - |
| 9.00 | Clamp ON Ultrasonic Flow meter for BAHP Pumps
(02 nos. for all two units of DTPS) common header Discharge Line for unit 6&7 DTPS. Type of Flow sensor: Full Bore type
Medium: Clean Raw water
Fluid velocity: 2-3 m/s
material of Pipe= MS Line Operating Pressure: 9.0 Kg/cm2
Maximum Pressure: 15.0 kg/cm2
Maximum flowrate: 1050 m3/hr.
Line Size: 300 mm NB | 1 | Nos. | - | - | - | - |
| 10.00 | Clamp ON Ultrasonic Flow meter for Flush Pumps (01 nos. for all two units of DTPS) header Discharge Line for unit 6 &7 DTPS. Type of Flow sensor: Full Bore Type
Medium: Clean Raw water
Fluid velocity: 2-3 m/s
material of Pipe= MS Line Operating Pressure: 2 Kg/cm2
Maximum Pressure: 5 kg/cm2
Maximum flowrate:965 m3/hr
Line Size: 400 mm NB | 1 | Nos. | - | - | - | - |
Tender Value
₹1.6 Cr
EMD Value
₹3 L
Closing Date
6 Jul 2020, 4:00 pmClosed
SE MM and MPC IV BTPS ANPARA
OFFICE OF SE MM and MPC IV BTPS ANPARA
Supply, Installation and Commissioning of Magnetic Flow Meters for ATP, Anpara
2020_RVUNL_461924_1
908/EPD-II/BTPS/ANP/2020-21
Open Tender
Electronics Equipment
Fixed-rate
30 days
ANPARA SONEBHADRA
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,720
DY CAO CFA and BO BTPS Anpara Sonbhadra
₹3 L
Yes
OFFICE OF SE MM and MPC IV BTPS ANPARA
4 Sept 2020
24 Apr 2020
8 Jul 2020
24 Apr 2020
6 Jul 2020
24 Apr 2020
29 Jun 2020
Electromagnetic Flow meter for LP Pumps (04 nos. Pumps for each unit) common header Discharge Line for unit 4 &5 BTPS. Type of Flow sensor: Full Bore Type Medium: Clean Raw water Fluid velocity: 2-3 m/s material of Pipe= MS Line Line Size: 450 mm NB Operating Pressure: 10 Kg/cm2 Maximum Pressure: 20 kg/cm2 Maximum flowrate: 1260 m3/hr
Electromagnetic Flow meter for HP Pumps ( 04 nos. Pumps for each unit) common header Discharge Line for unit 4 &5 BTPS. Type of Flow sensor: Full Bore Type Medium: Clean Raw water Fluid velocity: 2-3 m/s material of Pipe= MS Line Line Size:400 mm NB Operating Pressure: 14 Kg/cm2 Maximum Pressure: 20 kg/cm2 Maximum flowrate: 800 m3/hr
Electromagnetic Flow meter for LP Pumps (05 Nos. for all three units of ATPS) common header Discharge Line for unit 1,2 &3 ATPS. Type of Flow sensor: Full Bore Type Medium: Clean Raw water Fluid velocity: 2-3 m/s material of Pipe= MS Line Working Principle: Faradey Law's of Electromagnetic Induction Line Size:500 mm NB Operating Pressure: 6.5 Kg/cm2 Maximum Pressure: 12 kg/cm2 Wire housing: welded sheet steel Maximum flow rate: 1000 m3/hr
Electromagnetic Flow meter for HP Pumps (05 nos. Pumps for all three units of ATPS) common header Discharge Line for unit 1, 2 & 3 ATPS. Type of Flow sensor: Full Bore Type Medium: Clean Raw water Fluid velocity: 2-3 m/s material of Pipe= MS Line Line Size: 450 mm NB Operating Pressure: 10 Kg/cm2 Maximum Pressure: 20 kg/cm2 Maximum flowrate:1000 m3/hr
Electromagnetic Flow meter for AWRS Pumps for DTPS Discharge Line for unit 6&7. Type of Flow sensor: Full Bore Type Medium: AWRS Pond water Fluid velocity: 2-3 m/s Material of Pipe= MS Line Working Principle: Faradey Law's of Electromagnetic Induction Line Size: 800 mm NB Operating Pressure: 12-15 Kg/cm2 Maximum Design Pressure: 20 kg/cm2 Wire housing: welded sheet steel Maximum flowrate: 4000 m3/hr Pressure of AWRS water:<16 kg/cm2
Electromagnetic Flow meter for AWRS Pumps for ATPS & BTPS Discharge Line for unit 1 to 5. Type of Flow sensor: Full Bore Type Medium: AWRS Pond water Fluid velocity: 2-3 m/s Material of Pipe= MS Line Working Principle: Faradey Law's of Electromagnetic Induction Line Size: 500 mm NB Operating Pressure: 12-15 Kg/cm2 Maximum Design Pressure: 20 kg/cm2 Wire housing: welded sheet steel Maximum flowrate: 3000 m3/hr Pressure of AWRS water:<16 kg/cm2
Clamp ON Ultrasonic Flow meter for BALP Pumps (03 nos. BALP for all two units of DTPS) common header Discharge Line for unit 6&7 DTPS. Type of Flow sensor: Clamp On Type Medium: Clean Raw water Fluid velocity: 2-3 m/s material of Pipe= MS Line Operating Pressure: 2.5 Kg/cm2 Maximum Pressure: 5.0 kg/cm2 Maximum flowrate:1210 m3/hr. Line Size: 400 mm NB
Clamp ON Ultrasonic Flow meter for BALP Pumps (03 nos. BALP for all two units of DTPS) common header Discharge Line for unit 6&7 DTPS. Type of Flow sensor: Clamp On Type Medium: Clean Raw water Fluid velocity: 2-3 m/s material of Pipe= MS Line Operating Pressure: 2.5 Kg/cm2 Maximum Pressure: 5.0 kg/cm2 Maximum flowrate:1210 m3/hr. Line Size: 300 mm NB
Clamp ON Ultrasonic Flow meter for BAHP Pumps (02 nos. for all two units of DTPS) common header Discharge Line for unit 6&7 DTPS. Type of Flow sensor: Full Bore type Medium: Clean Raw water Fluid velocity: 2-3 m/s material of Pipe= MS Line Operating Pressure: 9.0 Kg/cm2 Maximum Pressure: 15.0 kg/cm2 Maximum flowrate: 1050 m3/hr. Line Size: 300 mm NB
Clamp ON Ultrasonic Flow meter for Flush Pumps (01 nos. for all two units of DTPS) header Discharge Line for unit 6 &7 DTPS. Type of Flow sensor: Full Bore Type Medium: Clean Raw water Fluid velocity: 2-3 m/s material of Pipe= MS Line Operating Pressure: 2 Kg/cm2 Maximum Pressure: 5 kg/cm2 Maximum flowrate:965 m3/hr Line Size: 400 mm NB
Clamp ON Ultrasonic Flow meter for FAHP Pumps ( 03 nos. for all two units of DTPS) Common header Discharge Line for unit 6 &7 DTPS. Type of Flow sensor: Full Bore Type Medium: Clean Raw water Fluid velocity: 2-3 m/s Material of Pipe= MS Line Operating Pressure: 7.5 Kg/cm2 Maximum Pressure: 15 kg/cm2 Maximum flowrate: 1050 m3/hr. Line Size: 350 mm NB
Clamp ON Ultrasonic Flow meter for FAHP Pumps ( 03 nos. for all two units of DTPS) Common header Discharge Line for unit 6 &7 DTPS. Type of Flow sensor: Full Bore Type Medium: Clean Raw water Fluid velocity: 2-3 m/s Material of Pipe= MS Line Operating Pressure: 7.5 Kg/cm2 Maximum Pressure: 15 kg/cm2 Maximum flowrate: 1050 m3/hr. Line Size: 200 mm NB
Clamp ON Ultrasonic Flow meter for recirculation line from Bottom Sludge Tank to Suction tank of ash water Pumps, Two recirculation line for unit 6 &7 DTPS. Type of Flow sensor: Full Bore Type Medium: Clean Raw water Fluid velocity: 2-3 m/s material of Pipe= MS Line Operating Pressure: 7.5 Kg/cm2 Maximum Pressure: 15 kg/cm2 Maximum flowrate:1050 m3/hr Line Size: 300 mm NB
Clamp ON Ultrasonic Flow meter for recirculation line from Bottom Sludge Tank to Suction tank of ash water Pumps, Two recirculation line for unit 6 &7 DTPS. Type of Flow sensor: Full Bore Type Medium: Clean Raw water Fluid velocity: 2-3 m/s material of Pipe= MS Line Operating Pressure: 7.5 Kg/cm2 Maximum Pressure: 15 kg/cm2 Maximum flowrate:1050 m3/hr Line Size: 200 mm NB
HMI with Touch Screen one for ATPS&BTPS and other one for DTPS
Magnetic flow data logger with continuous data connectivity to CPCB/UPCPCB server through GSM 4G/3G/@G modem with 05 year License one for ATPS&BTPS and other one for DTPS
AC control panel (PORTA cabin) with standard fitting like AC SPD, Power supplies, MCB, terminal Blocks, standard Key Lock
Central monitoring system
Air conditioner control panel
Erection, Installation testing and commissioning of electromagnetic Flow meters Equipment along with all accessories as mentioned above and as per requirement of pollution control Board
Comprehensive Maintenance Contract for routine, Preventive/breakdown maintenance of all installed system(Per month charges should be quoted in BOQ)
Knowledgelens Private Limited
AAXIS NANO TECHNOLOGIES PVT. LTD.
Krishna Agencies
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_687575.xls
BOQ • 0.29 MB
TenderSpecification908.pdf
Tender Documents • 1.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .