Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 1853 2ND FLOOR SURYA BAZAAR BHAGIRATH PLACE DELHI 06 | NORTH | DELHI | 110006 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹16.1 L
Closing Date
1 Sept 2021, 2:00 pmClosed
Director, DSCI
Delhi State Cancer Institute Dilshad Garden Delhi
Providing Service connection and external electrification i/c accessories for PSA Room at DSCI(East) Dilshad Garden, Delhi
2021_DSCI_207371_1
06/EE(E)/DSCI/2021-22
Open Tender
Miscellaneous Works
Item Rate
15 days
Delhi State Cancer Institute Dilshad Garden Delhi
As per eligibility creteria of e-tender
8 documents required · 8 mandatory
₹0
Exempted
8 Sept 2021
21 Aug 2021
1 Sept 2021
21 Aug 2021
1 Sept 2021
21 Aug 2021
Amount
Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size.as per direction of Engineer in charge. (Make -Havels/CCI/ Gloster)
3½ X 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizeon wall surface as required.
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Above 185 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 185 sq. mm (57 mm)
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Wiring forlight point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthling the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required.
Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required . (Make-Polycab/Havells/Finolex)
3 x 4 sq mm
6 x 4sq mm
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required(Make- Setia/AKG/).
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(Make Wipro/Legrand/Carbtree)
6 module
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. (Make-Wipro/Legrand/ Carbtree)
5/6 Amp switch
15/16 amp switch
3 pin 5/6 Amp socket
6 pin15/16 amp socket
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator). (make- ABB/Schiender/Legrand)
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(make-ABB/ Schiender /Legrand)
Single pole
SITC of 18” Exhaust fan 450 mm, 1400 RPM (Heavy duty industrial type) as per direction of Engineer in charge. (Crompton Greavs /Havels//Usha)
SITC of surface ceiling mount 70 watt flood light as required at site.as per direction of Engineer in charg. (Make-Philips/Havels/Crompton/wipro)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.(As per CPWD specification) (GI pipe makes -Zindal/Prakash/Apollo)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm).
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required
200 mm width X 50 mm depth X 1.6 mm thickness
vinay electric works
Uday Raj Pandey
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .