Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹41.5 L+₹4,115.50 (0.10%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest tenderer | |
| 3 | L3₹42.0 L+₹50,062.50 (1.21%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest tenderer | |
| 4 | L4₹44.2 L+₹2.8 L (6.65%)Rejected-Finance 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | L4 | Rejected-Finance Other than Lowest tenderer | |
| 5 | L5₹45.8 L+₹4.3 L (10.5%)Rejected-Finance 50A 7B 5C UMARPUR NIWA DHOOMANGANJ PRAYAGRAJ UP | PRAYAGRAJ | UTTAR PRADESH | 211011 | L5 | Rejected-Finance Other than Lowest tenderer |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
9 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Vipin Chandra Rai
GE UTILITY BATHINDA
REPAIR/ MAINT OF LT NETWORK AND CONNECTED ACESSORIES IN OFFICERS AND CIVILIAN ACCOMODATION OF BATHINDA CANTT UNDER GE (U) BATHINDA.
2024_MES_641800_1
8801/2023-24/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
Class D cat b i
9 documents required · 9 mandatory
₹500
Garrison Engineer (U) Bathinda
₹1 L
Yes
23 Mar 2024
10 Feb 2024
11 Mar 2024
10 Feb 2024
9 Mar 2024
24 Feb 2024
Amount
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, cable trenches etc not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material to a distance not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Material & labour sand cushioning using clean Fine River sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. ( Note:- Punned thickness shall be considered for payment purpose)
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type 1, Flat size 250mm x 150mm x 40mm complete all as specified.
Taking down over head ACSR conductor by disconnecting all service /XLPE cables of any size and reconnect the same cable to panels including suitable size of thimbling, necessary excavation required for laying of cable complete all as directed by the Engineer-in-Charge. Note:- The quoted rate shall include thimble, earthwork, disconnection and reconnection of cables etc and nothing shall be paid extra for this account.
Taking down LT pin and loop type insulators from pole complete all as directed by the Engineer-in-Charge.
Taking down old unserviceable MS cross arms, clamps etc from poles complete all as directed by the Engineer-in-Charge
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / hard standing /along poles and testing XLPE, LT Cable, with PVC outer sheath Type-I as per IS - 5831, insulated stranded aluminium conductor as Per Class-2 of IS - 8130 served with and inner sheathining of PVC tape- ST-I as per IS-5831 color Red, Yellow, Blue & Black ,armoured with Galvanised steel strip and over all PVC sheathed stranded conductor conforming to IS-1554 (Part-I & II) with latest amendments of Size cross sectional area 95 Sqmm 3.5 core ,1100 volts grade heavy duty complete all as specified and as directed.
All as per serial item No. 09 above but for cross sectional area 120 Sqmm 3.5 core ,1100 volts grade.
All as per serial item No. 09 above but for cross sectional area 185 Sqmm 3.5 core ,1100 volts grade.
All as per serial item No. 09 above but for cross sectional area 240 Sqmm 3.5 core ,1100 volts grade.
All as per serial item No. 09 above but for cross sectional area 25 Sqmm 4 core ,1100 volts grade.
All as per serial item No. 09 above but for cross sectional area 16 Sqmm 4 core ,1100 volts grade. Note for serial item No. 09 to 14 : Excavation and earth work shall be measured and paid separately under respective item.
S&F cable joint kit 1100 Volts heat shrinkable end termination kit indoor / outdoor type of size 70 to 150 sqmm complete all as directed.
S&F cable joint kit 1100 Volts heat shrinkable end termination kit indoor / outdoor type of size 185 to 300 sqmm complete all as directed.
Supply and laying or fixing GI tubing light grade 50 mm dia for cable protection including fitting fixed to poles / along wall / floor / under road / across the drain or nallah / laid in trench complete all as specified and directed.
M&L for making the horizontal boring under road and hard standing suitable for laying and inserting pipe 80 mm dia any length (including pipe and fittings) by mechanical drill system or Auger system and making the surface good as existing surface complete all as specified and directed. Note: The cost of GI pipe and fittings shall be included in the quoted rate of this item.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as directed.
M&L for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation, sub base filling and mass concrete including necessary formwork complete all as specified and directed.
Supply & fix in replacement of LED Solar Street Light 40W made with High Efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body with all necessary acessories complete as directed by Engr-in charge Make: Havells cat No. SOLAR AIO 40 W or equivalent of Bajaj / Crompton / Surya
M&L for replacement of out door type LT Feeder Pillar box ( Kiosk) of size not less than 60 cm x 45 cm x 45 cm made out 3.15 mm thick CRCA sheet (CPRI approved) with openable Front door including locking arrangement with Aluminium Busbar 200 amps rating and one MCCB 100 Amps ,25 KA and fixed on angle iron frame made out of 75 mm x 45 mm x 6 mm as in legs 15 cm high above ground level and 30 cm below ground level with PCC block made of PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate complete all as directed by the Engr in charge. Note : The make of CRCA sheet shall be of TATA / SAIL/ RINL/ JINDAL. Purchase Vr to be produced at the time of payment.
S&F in repair PVC cable Junction box for street light including 6 Amp MCB SP with aluminium bus bar TPN for controlling the Street Lights with pole mounting type size 250x200x105mm with 02 Nos. MS clamp of MS flat iron 40 x 6 mm with bolts, nuts and washer fixed on poles/walls complete all as directed by Engineer-in-Charge. Make:- Sintex/ Hensel/Siemens
Supply and fixing PVC insulated and over all PVC sheathed three core copper conductor cable multistranded of size 1.5 Sqmm drawn in and including 20 mm bore GI pipe light grade along the pole from junction box to light fitting including fixing accessories complete all as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI strip of size 25x4mm by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dully all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in Any type of Soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc after demolishing the existing one complete all as specified and directed. Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI wire of dia 4mm by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dully all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in Any type of Soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point after demolishing the existing one complete all as specified and directed. Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth wire
Opening / Disconnecting the electrical connection of defective / burnt out underground LT cable of any size & any core from main switch / DB / junction box / LT panel / L T O/H line etc. Taking out the length of cable to be required from existing loop, cutting the defective portion of cable ,providing to be required thimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc complete all as directed by Engineer-in-charge. Note:- (i) The cost of excavation & earth work,returning filling, in relaying of sand / bricks and cost of drawing the to be required length from protection pipe ,breaking of brick work / concrete / plaster to be required and redoing to be required for work to match the existing surface shall deem to be included in quoted rates and nothing extra shall be paid on this account. (ii) Additional cable/ protection pipe required at site shall be measured and paid seperatly.
m/s s.n. builders
Sandeep Enterprises
Vardhman Airport Solutions Pvt Ltd
SS CONSTRUCTION
AJ. Owners
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .