Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC ATR MAIN ROAD GARACHARMA II OPP MAHINDRA JADWET SHOWROOM SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.3 L+₹84,232.29 (4.34%)Rejected-AOC | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹20.6 L+₹1.1 L (5.87%)Rejected-AOC OPP CCS GARACHARMA PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹20.8 L+₹1.4 L (7.23%)Rejected-AOC | L4 | Rejected-AOC Not L1 | |
| 5 | L5₹21.0 L+₹1.5 L (7.93%)Rejected-AOC | L5 | Rejected-AOC Not L1 |
Tender Value
₹19.4 L
EMD Value
₹39,000
Closing Date
15 Jan 2022, 6:00 pmClosed
Garrison Engineer Brichgunj
GE Brichgunj Port Blair Junglighat
PROVN OF TOILET BLOCK NEAR BLDG NO. T-182/1 AND T-182/2 AT ILP LOCATION BRICHGUNJ MILITARY STATION UNDER GE BRICHGUNJ, PORT BLAIR
2021_MES_497353_1
8187A
Open Tender
Civil Works
Item Rate
Brichgunj
As per Nit Documents
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹39,000
Yes
31 Jan 2022
24 Dec 2021
17 Jan 2022
24 Dec 2021
15 Jan 2022
8 Jan 2022
Amount
Surface dressing not exceeding 15cm deep in soft/loose soil complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Excavation over areas, not exceeding 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation over area, exceeding 1.5m but not exceeding 3m deep and getting out in soft/loose soil complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L Precast Cement Concrete Block Masonry with Solid Block, exc 10cm in width in type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) all as specified.
M & L for RCC- M -30 Design Mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for Reinforced cement concrete design mix M-30 in columns, pillars, posts & struts complete all as specified and directed.
M&L for Reinforced cement concrete design mix M-30 in lintels over 1.5m clear span, beams and cantilevers complete all as specified and directed..
M & L for RCC- M -30 Design Mix as in slabs supported on walls,beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in,shelves and the likeall as specified and directed
Use & waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces of concrete complete all as specified and directed.
Use & waste of Form work to sides of square or rectangular columns, pillars, posts and struts for fair finished surfaces of concrete complete all as specified and directed.
Use & waste of Form work to sides & soffits of lintels over 1.5m clear span, floor or roof beams, cantilevers, etc for fair finished flat surfaces of concrete complete all as specified and directed.
Use & waste of Form work to chajjas and similar items including edges for fair finished flat surfaces of concrete complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F Mild steel TMT bars 6 to 8mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F Mild steel TMT bars 5 to 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for Rendering 10mm thick in cement mortar 1: 6 on faces of brick work or concrete surfaces, finished fair, even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished fair, even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in two coats on concrete surfaces such as roof slab; first coat (rendering coat) of 10 mm thick in cement mortar 1: 6 and second coat (finishing coat) of 5 mm thick in cement mortar 1: 4 mixed with 2% water proofing compound (water proofing compound to be measured separately as supply only) and finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1: 3 on on concrete surfaces such as roof slab, finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound
M&L for prepairing new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper, over chalk whitening complete all as specified and directed.
M&L for prepairing new plastered or unplastered surfaces of ceiling and applying two coats of oil bound distemper, over chalk whitening complete all as specified and directed.
M& L for two coat of wheather proof exterior acrylic emulsion paint with anti fungal property over a coat of primer and a coat of external wall putty on newly plastered wall surfaces including preperation of surfaces etc complete all as specified and as directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Spreading and leveling excavated approved soil in layers not exceeding 25cm thick including watering and well ramming complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in 100mm thick as in sub base complete all as specified and directed.
M&L for 25mm thick Cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate in leveling course as in RCC roof/ Floor surface complete all as specified and directed.
M&L for hard core of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick Cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in plinth protection complete all as specified and directed.
M&L 10mm thick cement plaster in cm (1:3) on top of roof slab complete all as specified and directed.
M&L for Non skid ceramic coloured tiles 7mm to 8mm thick (square/rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors, etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with & including 20mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Glazed ceramic concept tiles of size not less than 300mm x 200mm x 7mm thick, in vertical surfaces such as dados, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
S&F Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm wood grain printed PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (stiles) consisting of frame made out of MS Tubes for top & bottom rails, MS frame shall be covered with heat moulded wooden grain printed PVC sheet and 5mm thick x 15mm wide PVC sheet beading used inside stiles & rails and decorative PVC beading of 10mmx10mm used instead of exposed portion of PVC sheet beading.
S&F Butt hinges, extruded aluminium alloy with galvanized mild steel hinge pin, anodized, type B-21 , 100 mm size complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts of extruded section, 200mm long complete all as specified and directed.
S&F Extruded aluminium alloy handles, fabricated type, anodised, 150mm size complete all as specified and directed.
S&F 20mm dia CPVC SDR 11 and plain CPVC SDR 11 fittings fixed complete to walls, ceilings or in floors complete all as specified and directed
S&F 25mm dia CPVC SDR 11 and plain CPVC SDR 11 fittings fixed complete to walls, ceilings or in floors complete all as specified and directed
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000litres capacity including PVC cover, hoisted and fixed in position including connecting up pipes complete all as specified in SSR Part-I
S&F Stop valves/ Angle cock fancy type chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions 15mm bore complete all as specified and directed.
S&F Bib taps cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed.
S&F in Repair looking mirror Bevelled edge mirror 600 x 450 mm size, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with Chromium plated brass screws and cup washers, complete all as specified and directed.
S&F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20mm bore complete all as specified and directed.
S&F Mild steel Chromium plated grating 100 mm dia complete all as specified and directed.
S&F in repair vitreous china squatting pan orissa pattern of size 580x440mm white with integral foot rest and including connection to trap and to flushing pipe, anti syphonage pipe etc. including making good to floor complete all as specified and directed.
S&F PVC low level flushing cistern 10 liters capacity dual flush, ISI marked, white, with all fitting and fixtures including brackets complete all as specified and directed.
S&F Vitreous China Wash hand basin, white flat back size 550x400 mm including brackets(including Pillar Tap 15 mm bore Chromium plated cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts & PVC waste pipe) all as specified & directed by Engineer-in-charge.
S&F PVC connection 450 mm long with brass unions at both ends, suitable for 15 mm bore pipe, complete all as specified and directed.
S&F Cast iron floor trap with grating including jointing to waste pipe in in cement concrete type B1 (1:2:4), dia of outlet 100mm complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,laid in floor.
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 75mm complete all as specified and directed.
S&F 75mm dia outlet PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,laid in floors.
S&F 75mm dia PVC (SWR) bend with oval access door
S&F 110mm dia PVC (SWR) bend with oval access door
S&F PVC (SWR) vent cowl, 100mm dia complete all as specified and directed.
M&L for concrete bed to drain pipes 110mm bore including forming cradles; in cement concrete 1:3:6 type C2 using 40mm graded stone aggregate complete all as specified and directed.
M&L for precast man holes cover slab with 1:2:4 type B1 using 20mm graded stone aggregate set in CM 1:4 incl cost of use and waste of clean sawn wooden form work but excl cost of reinforcement all as specified.
M&L for Providing precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces incl cost of use and waste of clean sawn wooden form work, necessary moulds and setting in cement mortar 1:4 complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-ted/stoped ends etc
M&L in repairs water proofing treatment to RCC roof by priming the plastered surfaces with a coat of cold applied bituminous primer conforming to IS 2488 @ 0.30 kg/sqm and laying APP modified five layer polymeric membrane of minimum wt. 3.50 kg/sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) laid by torch application as per the manufacturers instructions with side overlap of 75mm & end overlap of 100mm & tucked into the chases on vertical surfaces to a height of 300mm & finally finished with bituminous aluminium paint @ 0.10 kg/sqm complete including taking down existing roof treatment all as specified and as directed.
S & F Aluminium anodised (minimum anodisation is 15 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge.(Aluminium section shall be of make Jindal/Hindalco/ Indalco). (Note:- Weight of various Aluminium sections handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only).
M & L for point wiring complete with single core multi stranded Copper conductor FRLS cable of size 1.5 sqmm PVC insulated unsheathed 1100 volt grade in and including PVC conduit suitable size including Tee junction bends etc concealed in wall/fixed on ceiling and PVC switch board hylam sheet of 3mm thick including M.S. sunken boards of suitable size for housing switched sockets etc including 1.5 sqmm. green PVC insulated wire for earth continuty.complete all as specified and as directed for (a) One light/E/fan point controlled by one switch
All as per item No.71 here - in - before but for 3 pin 5 Amps switch socket combination on independent board.
Supply and fix ceiling rose surface type 3 terminal, complete all as specfified and as directed
Supply and fix switch piano flush type single pole one way 5 amps, complete all as specified and as directed
Supply and fix switch socket outlet 3 & 2 pin (multi pin) 5 amp flush type.
Supply and fixing energy efficient LED Smart bright batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
Supply and fixing Mirror energy efficient LED Smart bright batten 10 watt fitting 2ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed.
Supply and fix MCB single pole, 240 volts, 5 to 32 Amps, all as specified and as directed.
Supply and fix MCB SPN 240 volts with breaking capacity 10KA, 5 to 32 Amps, all as specified and as directed.
Supply and fix ventilating fan Celso suitable for on working of AC 230 V ,50 Hz 200 mm sweep ,incl louvers complete all as specified
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 2 Core 10 sq mm.
Supply & lay cable protection pipe of Tele-Rex make -HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm(Outer Dia) confirming to IS 14930 -II and ISI Marked all specified and directed.
Supply and fix 25 mm bore GI tubing medium grade laid in trenches / floor or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out complete all as specified and directed
Supply and fix 25 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, complete all as specified and as directed
M&L for cutting existing 50mm GI line and making branch connection of 40 mm dia GI line complete all as specified and directed
Supply and fix 25 mm bore Gun Metal gate valve with iron wheel head ISI Marked screwed both ends suitable for GI tubing complete all as specifed and directed
M/s Kamal Electrical
DEEPAK AGENCIES
ANITA VARMA ENTERPRISES
M/s S U Enterprises
SK CONSTRUCTION
B.R. ENTERPRISES
Ravi Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .