Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.8 LAccepted-AOC PLOT NO 52 BAKSHI NAGAR JAMMU 180001 J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹1.1 Cr+₹7.9 L (8.08%)Rejected-Finance 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | L2 | Rejected-Finance Other than Lowest bidder | |
| 3 | L3₹1.1 Cr+₹14.9 L (15.3%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest bidder | |
| 4 | L4₹1.2 Cr+₹18.9 L (19.3%)Rejected-Finance 96 SHASTRI NAGAR SHASTRI NAGAR JAMMU JAMMU KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | L4 | Rejected-Finance Other than Lowest bidder | |
| 5 | L5₹1.3 Cr+₹31.4 L (32.2%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest bidder |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
16 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S Pradeep, CWE
MES HQ CWE Jammu
TENDER FOR ADDN/ALTN OF BLDG NO. P-2/40 OF 166 MH AT MIL STN JAMMU UNDER GE SATWARI
2024_MES_635958_2
CWEJP-55/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Satwari
please refer tender documents
9 documents required · 9 mandatory
₹1,000
GE SATWARI
₹2.2 L
Yes
19 Apr 2024
27 Jan 2024
19 Feb 2024
27 Jan 2024
16 Feb 2024
2 Feb 2024
Amount
Dismantling brick tiles or terracing tiles tripple layer (one layer below mud phuska) and two layer above mud Pushka on roofs.all as specified as directed.
Demolition of mud in roofs any thickness including plastering and leeping(whether full thickness removed or only a part there of) all as specified as directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position all as specified as directed..
Demolition of cement concrete (unreinforced) in ground floor to 4th floors and pavings not exceeding 15 cm thickness (below or above ground level ) and removing the rubbish from the work site out side defence premises complete all as specified as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, all as specified as directed.
Removing building mtaterials etc to a distance exceeding 1 Km upto 5 Km (Out of Defence land) and clearing the area all as directed by Engineer-in-Charge.all as specified as directed.
Cutting chases, pinning in, making good to facing where reqd and pointing in cement mortar 1:3 to ends of edges of landing etc and cutting chases for slab bearing cutting exc 10 cm but n.exc 20 cm girth.all as specified.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Use and waste of form work to sides and sofits of floor or roof beams, beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc to obtain rough finished flat surface of concrete complete all as specified and as directed.
RCC (Design Mix) M-25 using 20 mm graded crushed stone aggregate as in beams ,cantilevers, bressummers, lintel over 1.5 m span completed all as specified and directed.
RCC M-25 Design mix, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified as directed.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified as directed.
TMT mild steel bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and includingMS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
Rolled mild steel in roof trusses (framed) , trussed , purlins,crane gantries , rails and fastening and heavy bracket framing ( beam, tee, angle, channel or flat section) including distance pieces conforming to Fe 410-W, Gde E-250 Quality 'A', completeall as specified as directed.
Rolled Mild steel work as in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and like including caps bases, splices etc built up from two or more beam or channel sections or angles with plates or pipe section including all lattice bars, stiffeners, gusset plates etc..(Fe-410-W(Gde E-250)Quality-A)all as specified.
Complete removal( single Storey up to 20 feet )of existing water proofing treatment of any description( tile, PCC padding, mud phuska etc) incl under layer, taking down of cement plaster any thickness and removal of debris off the premises including grubbing up of trees and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt/dust all as specified as directed.
P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed. all as specified as directed.
Rendering 15mm thck in cement mortar 1:4 on Concrete surfaces of roof finished fair & evenr and including mixing of water proofing compound (WPC shall be measured and paid separately) all as specified as directed.
Supply only Water proofing compound liquid.all as specified as directed.
Water proofing treatment in the following sequences:- (a) Applying 1st course of bituminous primer conforming to IS -3384 @ 0.4 Kilogram/Square metre cover the surface till the surface properly impregnated and insolvent oil primer evoporate completely (b) Applying 2nd coat of blown 85/25 graded bitumen confirming to IS 702 @ 1.2 Kilogram/Square metre. (c) Applying 3rd course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kilogram/Square metre with 160 Grams/Square metre non woven polyester made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat complete all as specified and as directed . all as specified as directed.
Preparation of newly laid surfaces of APP Membrane and applying two coats of water based bituminious alumunium paint @ 200 ml per Square metre etc complete all as specified as directed.
Providing, cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate ), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed all as specified as directed.
Cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified as directed.
Removing bushes, shrubs, grass tree roots from building roof ( up to single storey 20 feet ) with chiesling and making good, the disturbed surface in PCC 1:1.5:3 complete all as specified and as directed all as specified as directed.
Grubbing out grith exc 15cm but not exc 100cm tree trunk including cutting of trunk portion from roof and wall (upto single storey 20 feet ) protruding over ground, digging out roots , fillling holes and leveling of roof stacking of serviceable material and removing of unserviciable material to a distance exc. 50m and clearing site and making good, the disturbed surface in PCC 1:1:5:3 complete all as specified as directed.
Demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material from the work site ouside defence premises complete all as specified as directed.
Brick work with subclass 'B' bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 completeall as specified as directed.
Brick work with subclass 'B' bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 but except bricks complete all as specified and as directed by Engineer-in-charge all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding, terrazo dado from wall surface (but not backing), removing serviceable tiles to store and rubbish off the premises. Complete all as specified as directed.
Roughening surfaces of old concrete floor by picking,sweping clean and washing down wih water toremove dust etc and brusing surface with neat cement slurry with 3.0 kg of cemrnt per sqm,removing serviceable tiles to store and rubbish off out the cantt area complete all as specified as directed.
Glazed ceramic coloured digital tiles in vertical surface 300x450x7 to 8mm thick, set and jointed in neat cement slurry and pointed white or colored cement to match the surface over and including 10 mm thick cement mortar 1:4 all as specified. (Sample as approved & Kept in GE's sample room)
Vitrified light shade ceramic coloured tiles 8 to 10mm thick area of each tile exceeding 0.18 Square metre but not exceeding 0.38 Square metre, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and 4 mm thick spacer including laying over 15 mm thick screed bed cement mortar 1:4 complete all as specified as directed.
Non-Skid Digital ceramic tiles 7 to 8mm thick (Square/rectangular area of each tile exceeding 0.11Sqm but not excedding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement ot match and set in neat cement slurry and pointed with coloured /white cement to match the surface over and including 15mm thick screed bed in CM 1:4
Description all as per srl item No 31 above but as in vrtical surfaces as skirting over a backing coat of 10 mm thick cement mortar 1:4,10 mm thick complete etc.all as specified as directed.
Mechina cut kota stone single piece slab in stairs steps & flooring 18 mm to 22 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with beez wax and including over and including screed bed or bedding layer 15 mm thick in cement mortar(1:6) all as specified and directed by Engr-in-charge. ( Note- length of kota slab not less than widht of stair.all as specified.
Mechine Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including CM 10 mm thick 1:4 rendering complete all as specified as directed.
20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over 15 mm thick CM 1:4 all as specified as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified.
50mm thick cement concrete 1:3:6, type C1, using 20mm graded crushed stone aggregate as in plinth protection, laid in slope of 1:20 and surface finished even and smooth without using extra cement including making joint at 3m interval and at each corner the joint shall be filled with bitumen mastic filling to full depth (comprising one part hot blown bitumen 85/25 and two part of sand), complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water etc, and removing unserviceable material outside cantt area, complete all as specified.
Rendering 15mm thick on fair faces of brick or concrete surface walls, in cement mortar 1:6 , rendering is to be finished even and smooth without using extra cement complete all as specified and all as specified as directed.
Rendering 15 mm thick on fair faces of brick or concrete surface walls, in cement mortar 1:4 , rendering is to be finished even and fair without using extra cement completeall as specified as directed.
Rendering 05 mm thick on fair faces of brick or concrete surface ceilings, in cement mortar 1:3 , rendering is to be finished even and smooth without using extra cement complete all as specified as directed.
Repairing of concrete surfaces such as balcony, chajjas, upward or downward facias ,column, pillar, ceiling and similar items with plain cement concrete 1:2:4 type B-0 or rendering 10-15mm thick as per site requirement in CM 1:3 without using extra cement finished even and fair complete all as specified and directed (Up to fourth storey bldgs and including necessory formwork and scaffolding required as per site condition also taking down or dismantling as required at site. all as specified as directed.
Applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description having width/girth exceeding 10 cm including preparation and rubbing with sand paper to make surface even and smooth complete all as specified.all as specified as directed.
Applying two coats of synthetic enamel paint on new wooden surfaces of any description over a coat of pink primer having width/girth exceeding 10 cm complete all as specified including preparation and necessary filling by chalk putty as and where required to make surface even and smooth. all as specified as directed.
Applying one coat of synthetic enamel paint on old painted wood surfaces of any description having width/girth exceeding 10 cm complete all as specified including preparation and where required to make surface even and smooth.all as specified as directed.
Preparation of old decorated concrete/ plastered surfaces of walls, Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots & rubbing with sand paper and applying two coat of oil bound distemper on old decorated wall surface including two coats of wall care putty of 3 mm thick on uneven surface as and where required.all as specified as directed.
Preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over two coat of wall care putty of 3 mm thick and one coat of primer complete all as specified as directed.
Preparation of New/old decorative plastered/concreat surface of wall, chajja, facia, face of columns, beam ect by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots & rubbing with sand paper and applying one coat of weather proof exterior emulsion (APEX) with necessary scaffoding up to 4th storey, including necessary filling of wall care putty on uneven surface as and where required all as specified.
Meterial and labour for applying two or more coats of 100% premum acrylic emulation paint having VOC less than 50gm/litre and UV resistance as per IS 15459:2004 , Alkali & fungal resitance dirt resitance exterior paint of required shade (Company dept tinted ) with slicon additives @1.43 Liter /10Sqm over and including primer coat of exterior primer applied @ 0.90 liter/10 Sqm over old /New plastered walls /Celling surface (work will be carried out in different shade the shade shall be directed all as specified as directed.
M/L for applying 1 to 2mm thick water proof putty on old/new plastered surfaced of walls and prepartation to recieving paint complete all as specified and as directed all as specified as directed.
Preparation of old decorated plastered /concrete/ brick surfaces of walls (up to single storey 20 feet with necessary scaffolding) and applying one coat of cement based paint on old decorated surfaces including preparation.all as specified as directed.
Preparation of old decorated brick /concrete plastered /un-plastered surfaces of walls, Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of lime white wash on the walls, pillars, cornices etc. complete all as specified and directed.all as specified.
Preparation of newly plastered surfaces of Ceiling and applying three coat of white wash on ceiling.all as specified as directed.
Preparation of old decorated brick /concrete plastered /un-plastered surfaces of Ceiling and applying one coat of white wash on ceiling.all as specified as directed.
Applying one coat of synthetic enamel paint on old painted steel surfaces of any description having width/girth exceeding 10 cm including preparation and rubbing with sand paper to make surface even and smooth and apply putty and primer where required complete all as specified as directed.
Taking down shutters of any description exc 1.00 Square metre and not exceeding 2.00 Square metre each and removing from the site all as specified & directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area not exc. 1.5 Square metre including making good of jambs of opening with rendering in cement mortar 1:4, complete all as specified and direcetd.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exc. 1.5 Square metre but n exc 4.0 Square metre including making good of jambs of opening with rendering in cement mortar 1:4, complete all as specified and direcetd.all as specified.
Pressed steel frames of size 125mm x 60mm made out of size 1.25mm thick MS sheet for doors single rebated including mild steel hinges medium weight 100 mm long and 25mm x 3mm flat iron in holdfast,tie bar including necessary fixing lugs, hold fast, lock strike plate and fixing arrangement etc complete as specified and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 including PCC 1:3:6 as in back fill to chowkats all as Specified.
Pressed steel frames of size 105mm x 60mm made out of size 1.25mm thick MS sheet for doors double rebated including mild steel hinges medium weight 100 mm long and 25mm x 3mm flat iron in holdfast,tie bar including necessary fixing lugs, hold fast, lock strike plate and fixing arrangement etc complete as specified and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 including PCC 1:3:6 as in back fill to chowkats all as Specified.
Material and labour for Providing cement concrete Type C 1 (1:3:6) using 20mm graded aggregate as in back filling of steel chowkhat single or double rebated or for fixing hold fast all as specified and directedall as specified.
35mm thick 2nd Class hard wood glazed,gauzed and skelton shutters open rebated and prepare to receive glass, gauge etc but divided into squares with plain chamfered or rounded mitred and rebated sash bars,stiles and rails as specified in SSR Part-I Sec 8 clause 8.24 (a) complete all as specified
Factory made, plain framed, panelled shutter (two Panel) 35mm thick, 2nd class Hardwood with lock rail and panel of 9 mm B.W.P commercial ply. The size of rail and stiles as per as per IS:1003 (Part-I),kiln seasoned and chemically pressure treated complete all as directed by Engr-in-Charge.all as specified.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm Plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specifications and drawing including making good to disturbed surface of walls, complete all as specified and as directed by Engr-in-Charge. all as specified.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppplying and fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engr-in-Charge.
Pressed steel cup board frame of MS sheet 1.25 mm thick size of frame 60 x 40 mm with rebate of 20 mm wide and 12 mm deep including PCC 1:2:4 as in filling to back of chowkats including butt hinges 100 mm long. Piano hinges measured separately.
Prelaminated MDF board 19 mm thick as in shutters/shelves (exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame worknincluding lipping (15 mm thick three sides and 20 mm thick lipping hinge side) around the shutter complete all as specified and as directed by Engr-in-Charge.
Supply & fixed in repairs continuous (piano) hinges, heavy duty mild steel, bright finish or electrogalvanised sutable for 19mm thick shutter and fixed, complete all as specified.
Butt hinges of mild steel cold rolled medium weight of size 100mm as specified.
Aluminium anodised, barrel tower bolts size 150 mm of extruded section and fixed complete all as specified. (ISI Marked) all as specified.
Aluminium handles, fabricated type, anodised Size-150 mm, anodised section and fixed complete all as specified. (ISI Marked) all as specified.
Aluminium alloy, anodised, sliding door bolt Size- 250 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified.all as specified.
Hasp & staple safety type aluminium anodised with mild steel hinges Spin including bolt to hinges plate fixed with screws of 75 mm in length. all as specified.
Aluminium hanging floor door stopper,Twin rubber stopper,size 100mm , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. all as specified.
Supply & fixed in Repair aluminium bottom door seal with brushes, length 1.2 mtr, fixed with screw, suitable for wooden door complete all as specified.all as specified.
Supply & fixed in Repair mild steel helical ordinary rat tail rod pattern springs 300mm including roller and roller plate complete including fixing to pressed steel frames necessary welding work all as specified and as directed.all as specified.
Supply & fixed in Repair 25mm outer dia stainless steel decorative drapery rod of thickness 20 gauge and for every 01 RM length, with stainless steel brackets near to ends with stainless steel finials for 25mm dia drapery rod at both ends. The drapery rod shall be projecting 150 mm outer side from the clear opening of doors/windows. ( Including necessary fittings) all as specified.
Factory made steel windows double shutter box type, outer frame made out of ERW TUBE 'P' section(60x45x25mm) and shutters of ERW TUBE 'P' section (50x35x20mm) operable shutters side hung includding pistol hinges with two Nos of MS Tower bolts 150mm size on each shutter steel handle and stopper of 'Z' section as specified complete with sash bars devetailed or welded ready for glass fixing and wire gauzed fixing with suitabel fittings/openning for cooler/AC where required .Steel windows will be double shutter external glazed and internal wire gauzed complete all as specifed and as per Drg No CEPZ/TD-324/07 1/3 to 3/3 all as specified and directed by Engr-in-Charge. NOTE: The quoted rate against the above item shall also include (i) for Provn of one shop coat of zinc chromate primer on all exposed steel surfaces and one coat of coal tar on the ends of steel frame in contact with brick/conc surface (ii) 04 Nos MS Steel lugs of 20x5mm MS flat 20cm long over all welded to frames (iii) PCC block for embedding lugs.all as specified.
Description all as per srl item No 80 above but as in ventilators any size all as specified.
Mild steel works , square bar, round bars etc. as in framed work such as grills, guard bars, gratings etc incl bending, cutting and welding as necessary of confirming to Gde Fe 310-0 all as specified.
4 mm thick sheet glass ordinary quality glazing with oil putty or any type of beads in square n.exc. 0.5 Sq each pane in any type of frame of iron/Steel/Wood/Aluminium as required at site complete all as specified (upto fourth storey with necessary scaffolding), all as specified.
4 mm thick figured glass, pin head type and glazing with oil putty or any type of beads in square n.exc. 0.5 Sq each pane in any type of frame of iron/Steel/Wood/Aluminium as required at site complete all as specified (upto fourth storey with necessary scaffolding), all as specified.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified fixed with stainless steel wire staples.all as specified.
Supply & fixed in Repair CP Bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified complete all as specified.
Supply & fixed in Repair angle valve with wall flange , cast copper alloy, chromium plated fancy type screwed for 15 mm iron pipe, complete all as specified.
Supply & fixed in Repair Stop valves, cast copper alloy,fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed , complete all as specified.
Supply & fixed in Repair CP Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified.
Supply & fixed in Repair tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified.
Supply & fixed in Repair PVC connection 15 mm x 600 mm including brass check nut at both ends screwed for iron pipe of 15 mm bore.
Supply & fixed in Repair Brass chromium plated shower rose with or without swivel joints, 125mm size, including fixing to steel pipe or union
Supply & fixed in Repair Vitreous China, wash basin white, flat back , size 550mmx400 including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32 mm dia, waste coupling of chromium plated brass. complete all as specified and as directed by Engineer-in-charge..
Supply & fixed in Repair r waste coupling of chromium plated brass 32 mm dia with long screwed shank and fly nuts complete as suitable for wash hand basin all as specified .
Supply & fixed in Repair PVC valveless,syphonic action type, flushing cistern, low level,white with inlet, ball valve, float and handle including brackets, PVC 32 mm 'L' bend of capacity 10.0 litres and making good to dismantled/damaged floor/surfaces, fixing in repair, complete all as specified and as directed by Engineer-in-charge.
Supply & fixed in Repair WC Orissa pattern white with integral foot rest 580x 440 mm including L bend, & PCC bedding in 1:2:4 and making good disturbed floor connecting to trap and flush pipe compete all as specified.(Rate of including in taking out and removal of old WC seat unhygienic condition).
Supply & fixed in Repair Urinal (CAPRIANA in white colour, ) half stall with complete accessories Set, CP Waste Coupling, PVC waste pipe, sprader etc. Size: 375 x 390 x 590 mm complete all as specified.
Supply & fixed in Repair stainless steel lock grating plain/hole size 100 mm dia including embeding in tiles with white cement complete all as specified.
Supply & fixed in Repair PVC Waste pipe 32mm bore of required length complete all as specified.
Supply & fixed in Repair rotational moulded polyethylene water storage tanks of 500 litres capacity,(cylindrical vertical with closed top) with plastic lid cover, triple layered, white, hoisted and fixed in position all as specified in SSR Part-I including PTMT Ball valves high pressure with epoxy coated Aluminium rod & high density plastic ball complete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections complete all as specified .
Dismantling water tanks 500 ltr capacity and removing from site complete all as specified.
Supply & fixed in Repair Gun-metal, globe or gate valves, with iron wheel head,screwed both ends for iron pipe of 15 mm bore pipe, including making connections complete all as specified.
Supply & fixed in Repair Gun-metal, globe or gate valves, with iron wheel head,screwed both ends for iron pipe of 20 mm bore pipe, including making connections complete all as specified.
Taking up or down steel tubing of 15 mm bore pipe and connections,including cleaning for re-fixing or removal to store, complete all as specified and as directed
Taking up or down steel tubing of 20 mm bore pipe and connections,including cleaning for re-fixing or removal to store, complete all as specified and as directed
Supply & fixed in Repair of tubes 'medium grade' galvanised, 15 mm bore, ISI marked with all fitting such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge
Supply & fixed in Repair of tubes 'medium grade' galvanised, 20 mm bore, ISI marked with all fitting such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
cutting chases, pinning in , making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings,steps,cills,sunshades,shelves,lintels etc,and cutting chases for concealed water tubing or concealed conduit wiring,etc,and making good,cutting n.exc 10cm girth in brick walls.
Dismantling PVC/Cement/CI pipes 50 to 110 mm dia including all fittings like bend,branch pieces, connectors, heel rest bend etc and removing from site all as specified and directed
UPVC (SWR) type B pipes 110 mm bore single socketed in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed by Engineer-in-charge.
UPVC (SWR) type B pipes 110 mm bore single socketed, in any length with rubber ring joints fixed to walls including stack clamp of GI flat 30mm wide 2mm thick fixed to wall with nail at spacing of 1m center to center , complete all as specified and as directed by Engineer-in-charge.
UPVC (SWR) type B pipes 75 mm bore single socketed in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed by Engineer-in-charge.
UPVC(SWR) type B pipes 75 mm bore single socketed, in any length with rubber ring joints fixed to walls including stack clamp of GI flat 30mm wide 2mm thick fixed to wall with nail at spacing of 1m center to center , complete all as specified and as directed by Engineer-in-charge.
PVC (SWR) 'P’ trap 110 mm bore , complete all as specified and as directed by Engineer-in-charge.all as specified.
UPVC (SWR) , bends with access door for 75 mm bore , complete all as specified and as directed by Engineer-in-charge.all as specified.
UPVC(SWR) , bends for 110 mm bore complete all as specified and as directed by Engineer-in-charge.all as specified.
UPVC(SWR) , bends with access door, for 110 mm bore complete all as specified and as directed by Engineer-in-charge.
UPVC(SWR), junction single, (single 'T') with access door equal or unequal for 110 mm bore , complete all as specified and as directed by Engineer-in-charge.
UPVC (SWR) , reducers 110 mm dia complete all as specified.
UPVC (SWR) vent cowl 75 mm dia complete all as specified.
Supply and fixed in repair UPVC (SWR) floor trap plain with grating having dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
Supply and fixed in repair, UPVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out any type of soil.
75 mm thick plain cement concrete (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foudation, filling, sub base and mass concrete all as specified.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.
Taking down carefully aluminium conductor point wiring (light, fan, light socket, power socket) complete fitting such as swithes, sockets, lamp holder, utility light fitting, fan regulator etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed.
Material and labour for complete point wiring with 1.5 Square metrem single core multi stranded copper conductor FRLSH insulated and sheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 Square metrem multistranded copper conductor FRLSH insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked terminated into GI/pressed steel modular terminal boxes including modular switch cover IS marked for mounting modular switches, sockets, fan regulators etc complete all as specified as directed.
One light/fan point controlled by one, one way switch 6 Amp complete
Description all as per item above No 127 but one 3 pin modular socket outlet 6 amp independent board
Description all as per item above No 127 but one 3 pin modular socket outlet 6 amp on same board
Description all as per item above No 127 but one 3 pin 6 Amps modular socket outlet independent but below the switch board of light points in the same vertical plane
Description all as per srl item No 127 above but for one 3 pin modular socket outlet 15/16 Amps independent with cable of size 2.5 Square metrem for point wiring and 2.5 Square metrem as in continuous earth wire.
Switch modular one way 06 Amp,1 module all as specified and directed.
Switch modular one way 16 Amp,1 module all as specified and directed.
Modular socket 6A-2/3 Pin 2 module 230V AC all as specified and directed.
Modular socket 6A/16A-3 Pin 2 module 230V AC all as specified and directed.
LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
Taking down carefully AC ceiling fan 1200/1400mm sweep complete in situ at site for servicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing with detergent powder to fan blades, greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washer check nuts split pin rubber packing and rubber seal etc and including providing and replacing any item found damaged/unserviceable i,e split pin screw for blades, body & reel capacitor of appropriate capacity, PVC connector, MS galvanised check nut, rubber pads, steel strip clamps, etc to put the fan for smooth and satisfactory working, refixing the fan, motor after executing necessary servicing to their positions, connecting to electric system and testing complete all as specified and as directed by Engr-in-Charge. if any as directed.
Exhaust fan, steel body AC single Phase. 230V of size 380m sweep with, blades, and frame and louvers all as specified and directed.
Ceiling fan complete with blade, down rods, hook type anchor fastener and accessories, 230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and connected from ceiling rose/ connector with & including suitable size flexible copper conductor PVC insulated sheathed cord, complete.all as specified as directed.
Ceiling rose surface, backelite, three terminal, 240 volts complete all as specified and directed.
Lamp holder, Polycarbonate type with back plate suitable for batten fittings all as specified and as directed.
Down rod (hanging rod) made of GI tubing 20mm bore for length upto 90cm suitable for AC ceiling fan of size 1200mm /1400mm sweep including provision of hole for fixing of nut and bolt all as specified.
LED light fitting 1 x 20 Watt, 220 V AC batten retrofit type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
MCB SPN complete 40-63Amp with rupturing capacity 10 KA 'C' series, Complete all as specified and directed.
MCB single pole 6 to 32 Amp with rupturing capacity 10 KA 'C' series complete all as specified and directed.
Vertical Distribution Board (TP&N) 4 way double door suitable for MCCB 3/4 pole of cap upto 125 Amp as incomer and out going MCBs SP and should be IP 43 IK-09 protected with Copper Bus Bars, Neutral Links, Earthing bar flush mounting including cutting chases and making good the distrubed surface of the mounting all as specified and directed.
MCCB four pole 100 Amp, 16 KA, 415 volts with adjustable thermal settings all as spcified and ditected. Note: VTPN DB and MCCB should be of same make.
Distribution Board (SPN) double door 12 Way and should be IP 43 IK-09 protected with Copper Bus bar, Earth Bar, neutral Bar flush mounting including cutting chases and making good the distrubed surface of the mounting all as specified and directed.
Distribution Board (SPN) double door 08 Way and should be IP43 IK-09 protected with Bus bar, Earth Bar, neutral Bar flush mounting including cutting chases and making good the distrubed surface of the mounting all as specified and directed.
Distribution Board (SPN) double door 04 Way and should be IP 43 IK-09 protected with Bus bar, Earth Bar, neutral Bar flush mounting including cutting chases and making good the distrubed surface of the mounting all as specified and directed.
Sub main wiring with single core cable 2 x 6 sq mm FRLS insulated Unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed) medium grade alongwith 1x6 Sq mm FRLS insulated unheathed copper conductor cable as earth wire connected with main earth dolly including chiseling, cutting & making good to match with the existing surface complete all as specified and directed.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25 Square metrem 3.5 core all as specifed and directed.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in hard/dense and getting out soil, complete all as specified as directed..
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified as directed.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI pipe of size 40 mm light grade for floor, road cutting and protection of cable completeall as specified as directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 4 Kilogram/Square metre. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 161 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
GUPTA CONSTRUCTION
M/S Shesh Paul Gupta
M/S MOHAN LAL GUPTA
Kanwal Nain Behl
M/S ARUN ANAND
Ms International Engineers
SUNIL KUMAR SANGEET KUMAR AND SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .