Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | L1 | Accepted-AOC Due to lowest accepted | |
| 2 | L2₹12.4 L+₹1.6 L (15.2%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹12.5 L+₹1.7 L (15.4%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹16.4 L+₹5.6 L (51.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹20.0 L+₹9.1 L (84.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Ludhiana-141001
REPAIR / REPLACEMENT TO CAPACITOR BANK AND MISC WORKS AT DHOLEWAL, DORAHA, CG COMPLEX, BADDOWAL AND MOGA UNDER GE LUDHIANA
2023_MES_575441_1
GE/LDH-68/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Dholewa Doraha Baddowal Moga under GE Ludhiana
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹40,000
Yes
27 Feb 2023
17 Jan 2023
14 Feb 2023
17 Jan 2023
13 Feb 2023
31 Jan 2023
17 Jan 2023 - 30 Jan 2023
Amount
Taking down current transformers any make/capacity completed all as specified and directed.
Supply & fixing in replacement current transformer CT25/5A CL 1 5VA Spare suitable for APFC Panel complete all as specified and as directed. Make:- Neptune/Havells/L&T/Indo Asian
Supply & fixing in replacement current transformer CT50/5A CL 1 5VA Spare suitable for APFC Panel complete all as specified and as directed. Make:- Neptune/Havells/L&T/Indo Asian
Supply & fixing in replacement current transformer CT 75/5A CL 1 5VA Spare suitable for APFC Panel complete all as specified and as directed . Make:- Neptune/Havells/L&T/Indo Asian
Taking down power factor controller any make/ capacity completed all as specified and directed.
Supply & fixing in replacement power factor controller relay latest micro controller based tech with true RMS sensing alarm avilable , delay adjustment , LCD display range 08 steps , 7 segment LED display size 144 X 144mm Auxillary supply 90-550 VAC, NTC tempature sensor , power factor measurement range 0.8 lag to 0.8 le suitable for APFC Panel complete all as specified and as directed. Make:- Neptune/ ABB/L&T/Indo Asian/ Semens
Supply & fixing in replacement power factor controller relay latest micro controller based tech with true RMS sensing alarm avilable , delay adjustment , LCD display range 12 steps , 7 segment LED display size 144 X 144mm Auxillary supply 90-550 VAC, NTC tempature sensor , power factor measurement range 0.8 lag to 0.8 le suitable for APFC Panel complete all as specified and as directed. Make:-Neptune/ ABB/L&T/Indo Asian/ Semens
Taking down old capacitor any make/ capacity completed all as specified and directed .
Supply & fixing in replacement heavy duty cylindrical capicitos 1 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed . Make:- Neptune/Havells/L&T/Indo Asian
Supply & fixing in replacement heavy duty cylindrical capicitos 3 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed . Make:- Neptune/Havells/L&T/Indo Asian
Supply & fixing in replacement heavy duty cylindrical capicitos 5 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed . Make:- Neptune/Havells/L&T/Indo Asian
Supply & fixing in replacement heavy duty cylindrical capicitos 10 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed. Make:- EPCOS/Neptune/Havells/L&T/Indo Asian
Supply & fixing in replacement heavy duty cylindrical capicitos 15 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed. Make:- EPCOS/Neptune/Havells/L&T/Indo Asian
Supply & fixing heavy duty cylindrical capicitos 20 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed. Make:- Neptune/Havells/L&T/Indo Asian
Supply and fix in replacement capacitor duty contractor 3P, AC3 , 12 amp (2NO, 2NC) of suitable up to 5 KVAR APFC panel ratings for APFC Panels complete all as specified and as directed Make:- Havells/L&T/Indo Asian
Supply and fix in replacement capacitor duty contractor 3P, AC3 , 20 amp (2NO, 2NC) of suitable up to 10 KVAR APFC panel ratings for APFC Panels complete all as specified and as directed Make:- Havells/L&T/Indo Asian
Supply and fix in replacement capacitor duty contractor 3P, AC3 , 32 amp (2NO, 2NC) of suitable up to 15KVAR APFC panel ratings for APFC Panels complete all as specified and as directed Make:- Havells/L&T/Indo Asian
Supply and fix in replacement capacitor duty contractor 3P, AC3 , 40 amp (2NO, 2NC) of suitable up to 20 KVAR APFC panel ratings for APFC Panels complete all as specified and as directed Make:- Havells/L&T/Indo Asian
Taking down old MCCB/MCB any make/ capacity completed all as specified and directed .
Supply and Fixing in replacement 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and as directed. Make:- Havells/L&T/Indo Asian/ Hager
Supply and Fixing in replacement 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and as directed. Make:- Havells/L&T/Indo Asian/Hager
Supply and Fixing in replacement 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and as directed by Engr-in-charge Make:- Havells/L&T/Indo Asian/Hager
Supply and Fixing in replacement 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and as directed by Engr-in-charge Make:- Havells/L&T/Indo Asian/Hager
Supply and Fixing in replacement 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and as directed. Make:- Havells/L&T/Indo Asian/Hager
Supply and Fixing in replacement C Curve 3 Pole MCB 63 Amp, 50 Hz, 415 V with rupturing capacity 10 KA complete all as specified and as directed by Engr-in-charge Make:- Havells/L&T/Indo Asian/Hager
Supply and Fixing in replacement C Curve 3 Pole MCB 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA complete all as specified and as directed. Make:- Havells/L&T/Indo Asian/Hager
Supply and Fixing in replacement C Curve 3 Pole MCB 40 Amp, 50 Hz, 415 V with rupturing capacity 10 KA complete all as specified and as directed.Make:- Havells/L&T/Indo Asian/Hager
Supply and fix in replacement wiring complete 6.0 Sqmm single core PVC insulated FR LS cable 1100 volts grade multistranded copper conductor cable with multistranded copper conductor cable as earth continuity conductor, all as specified and as directed Make:- Havells/Finolex/Anchor/Plaza
Supply & fixing in replacement panel mounted voltmeter three phase incl with CTs/ PT ratio 4 digit display , class 1.0 in 96X96 Sq mm flush mounted case suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement panel mounted Ammeter three phase incl with CTs/ PT ratio 4 digit display, class 1.0 in 96X96 Sq mm flush mounted case suitable for APFC Panel complete all as specified and as directed
Material and labour in replacement of indicator lamp in red, yellow and blue colour with lamp holder multi LED type complete including wiring with copper conductor cable of suitable size all as specified .
Material and labour in replacement of slector switch complete including wiring with copper conductor cable of suitable size all as specified .
Supply, laying replacement and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size size 120 sq mm 3.5 core complete all as specified and as directed. Make:- Havells/ Finolex/Polycab/Gemscab
Supply, laying replacement and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size size 95 sq mm 3.5 core complete all as specified and as directed. Make:- Havells/ Finolex/Polycab/Gemscab
Supply, laying in replacement and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size size 70 sq mm 3.5 core complete all as specified and as directed. Make:- Havells/ Finolex/Polycab/Gemscab
Excavation in trenches in soft/ loose of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for taking out of unserviceable under ground cable complete all as specified and directed..
Returning, filling in, any type of soil and spreading, in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus soil (any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed & complete all as specified and directed.
Supplying and laying bricks common brunt clay building bricks sub class B incl removing of old bricks complete all as specified and directed
Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed .
M&L for painting of panel board inner & outer complete with synthetic enamel paint by spraying including filling cavaties with filler one coat after cleaning all dust/rust including writing the Distribution/Panel Number and panel details all as directed .. Note: The Quoted rates are inclusive of white wash to fountation of Panel Board/ Painting to Angle Frames complete.
Supply, laying in replacement and testing twin core PVC bedded round and flate, electric power cables 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed .
JASSI TRADERS
SUN MANN ENGINEERS
PAWAN KUMAR GOVT. CONTRACTORS
Aziz Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .