Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹9.3 L+₹19,262.47 (2.11%)Rejected-Finance 6 KRIPANATH DUTTA ROAD KOLKATA 700 002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹9.4 L+₹23,851.49 (2.62%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L3 | Rejected-Finance NOT L1 BIDDER | |
| 4 | L4₹9.4 L+₹28,411.32 (3.12%)Rejected-Finance 18 SANKAR BOSE ROAD KOLKATA | L4 | Rejected-Finance NOT L1 BIDDER |
Tender Value
₹9.2 L
EMD Value
₹19,000
Closing Date
3 Apr 2024, 4:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER,CMD.
EE,CMD, 5TH FLOOR, PURTA BHAVAN
Repairing_and_modification_of_Gaseous_chlorination_system_at_different_OHR_sites_under_surface_water_based_water_supply_scheme_for_arsenic_affected_area_of_Purbasthali_II_Block__Dist_Purba_Bardhaman__under_CMD__PHE__Dte_
2024_PHED_684350_4
WBPHED/EE/CMD/ENIT-20/2023-24
Open Tender
CIVIL AND ELECTRICAL WORKS
Item Rate
30 days
PURBA BARDHAMAN
Repairing_and_modification_of_Gaseous_chlorination_system_at_different_OHR_sites_under_surface_water_based_water_supply_scheme_for_arsenic_affected_area_of_Purbasthali_II_Block__Dist_Purba_Bardhaman__under_CMD__PHE__Dte_
6 documents required · 6 mandatory
₹19,000
19 May 2025
16 Mar 2024
8 Apr 2024
18 Mar 2024
3 Apr 2024
18 Mar 2024
Amount
Dafarpota (Zone-II) OHR
Taking out two nos. vacuum regulator from the system after disconnecting all lines & connections and dismantling the same part by part along with cleaning washing the same with proper cleaning agent to segregate serviceable & un-serviceable spares
Taking out two nos. ejector from the system after disconnecting all lines & connection and dismantling the same part by part along with cleaning washing the same with proper cleaning agent to segregate serviceable & un-serviceable spares.
Supply & delivery of following spares for vacuum regulator assembly:
2 kg/hr. vacuum regulator assembly (Part no-VR201C).Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Vent plug 'O' ring (OV-11-009). Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Rate valve 'O' ring (OV-11-006) Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Meter gasket (G-100-3) Make- Capco Water Solution Pvt.Ltd/ PHED approved make
O' ring for meter inlet plug (OV-11-112) Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Sealing diaphragm (D-102) Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Vacuum sealing 'O' ring (OV-11-332)
Supply & delivery of following spares for ejector:
Ejector assembly 14 # set 0-2 kg/hr. Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Ejector diaphragm (D-104) Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Ejector 'O' ring (OC-11-210) Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Support diaphragm (D-105) Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Ejector diaphragm nut (U-1687) Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Ejector diaphragm bolt (U-236) Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Nozzle gasket (G-107)
Supply & delivery of following spares for vacuum line:
Flexible copper tube (F-100-2)
Chlorine pressure gauge (0-16 kg)
Lead Gasket (G-111)
Lead Gasket (G-140)
Lead Gasket (G-100)
Repairing the vacuum regulators with newly supplied spares as mentioned in sl. No. 3 (ii to vii) along with installing the newly supplied vacuum regulator as mentioned in sl. No. 3 (i) and re-assembling the repaired vacuum regulator and re-connecting all lines and connections
Repairing the ejectors with newly supplied spares as mentioned in sl. No. 4 (ii to vii) along with installing the newly supplied ejector assembly as mentioned in sl. No. 4 (i) and re-assembling the repaired ejector and re-connecting all lines and connections
Servicing the vacuum line by cleaning washing with proper cleaning agent to remove accumulated sludge inside the pipe line along with fitting fixing newly supplied spares as mentioned in sl. No. 5 (I to v)
Dhitpur (Zone-IV)
Taking out two nos. vacuum regulator from the system after disconnecting all lines & connections and dismantling the same part by part along with cleaning washing the same with proper cleaning agent to segregate serviceable & un-serviceable spares
Taking out one no. ejector assembly from the system after disconnecting all lines & connection and dismantling the same part by part along with cleaning washing the same with proper cleaning agent to segregate serviceable & un-serviceable spares.
Supply & delivery of following spares for vacuum regulator assembly:
1 kg/hr. vacuum regulator assembly (Part no-VR201C) Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Inlet capsule assembly (BM-4869) Make- Capco Water Solution Pvt.Ltd/ PHED approved
Vent plug 'O' ring (OV-11-009) Make- CapcoWater Solution Pvt.Ltd/PHED approved make
Rate valve 'O' ring (OV-11-006) Make- Capco Water Solution Pvt.Ltd/ PHED approved make
Meter gasket (G-100-3) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
O' ring for meter inlet plug (OV-11-112)
Supply & delivery of following spares for ejector assembly:
Ejector diaphragm (D-104) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
Ejector 'O' ring (OC-11-210) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
Ejector diaphragm nut (U-1683) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
Ejector diaphragm bolt (U-236) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
Supply & delivery of following spares for vacuum line:
Flexible copper tube (F-100-2)
Lead Gasket (G-140)
Lead Gasket (G-111)
Lead Gasket (G-100)
1" PVC MAPT
Repairing the vacuum regulators with newly supplied spares as mentioned in sl. No. 3 (ii to vi) along with installing the newly supplied vacuum regulator as mentioned in sl. No. 3 (i) and re-assembling the repaired vacuum regulator and re-connecting all lines and connections
Repairing one no. ejector with newly supplied spares as mentioned in sl. No. 4 (i to iv) and re-assembling the same along with re-connecting all lines and connections
Servicing the gas line by cleaning washing with proper cleaning agent to remove accumulated sludge along with fitting fixing newly supplied spares as mentioned in sl. No. 5 all complete as per direction of EIC
Nimdaha (Zone-III)
Taking out one no. vacuum regulator from the system after disconnecting all lines & connections and dismantling the same part by part along with cleaning washing the same with proper cleaning agent to segregate serviceable & un-serviceable spares
Taking out one nos. ejector from the system after disconnecting all lines & connection and dismantling the same part by part along with cleaning washing the same with proper cleaning agent to segregate serviceable & un-serviceable spares.
Supply & delivery of following spares for vacuum regulator assembly:
Vacuum sealing 'O' ring (OV-11-332) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
Sealing diaphragm (D-102) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
Vent plug 'O' ring (OV-11-009) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
Meter gasket (G-100-3) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
O' ring for meter inlet plug (OV-11-112)
Rate valve 'O' ring (OV-11-006)
Supply & delivery of following spares for ejector assembly:
Ejector diaphragm (D-104) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
Ejector diaphragm nut (U-1683) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
Ejector diaphragm bolt (U-236) Make-Capco Water Solution Pvt.Ltd/ PHED approved make
Ejector 'O' ring (OC-11-210)
Supply & delivery of following spares for vacuum line:
Chlorine pressure gauge (0-16 kg)
Isolation valve with yoke clamp
Lead Gasket (G-140)
Lead Gasket (G-111)
Lead Gasket (G-100)
1" PVC flange
Repairing one no. vacuum regulators with newly supplied spares as mentioned in sl. No. 3 (ii to vi) and re-assembling the same along with re-connecting all lines and connections
Repairing one no. ejector with newly supplied spares as mentioned in sl. No. 4 (i to iv) and re-assembling the same along with re-connecting all lines and connections
Servicing the gas line by cleaning washing with proper cleaning agent to remove accumulated sludge along with fitting fixing newly supplied spares as mentioned in sl. No. 5 all complete as per direction of EIC
Add. GST@18%
Add. Cess@1%
B T PROJECTS PRIVATE LIMITED
WEST BENGAL ENGINEERING CO.
M S ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .